You are on page 1of 8

COMFORT

APPLICATIONS
PRODUCT OVERVIEW

CHILLERS

HEAT PUMPS

UNITS FOR SIMULTANEOUS AND INDEPENDENT PRODUCTION OF HOT AND COLD WATER

ROOFTOP UNITS

AIR HANDLING UNITS

HYDRONIC TERMINALS

CONTROL, SUPERVISION AND OPTIMISATION SYSTEMS NEW GREEN


REFRIGERANT SERIES
ANCILLARY PRODUCTS

1234ze
SERIES

R513A
SERIES

climaveneta.com
CLIMAVENETA’S
MISSION

Climaveneta’s mission is to provide energy efficient heating,


air conditioning, and optimisation solutions that enhance
everyone's comfort, improve the profitability of a building,
and do not contribute to an increase in CO2 levels.

As a European leader in the HVAC industry, efficiency, and environmental sustainability to modern
Climaveneta has provided premium air conditioning buildings, as well as for the health, and well-being of
and heating solutions for the most challenging and the people who spend their time there.
demanding projects worldwide for over 45 years.
Building on this strong legacy, Mitsubishi Electric These solutions are backed by a business approach
Hydronics & IT Cooling Systems S.p.A. has decided based on flexibility and capability to adapt the system
to turn Climaveneta into the Group’s specialized brand to the requirements of each project, as well as on vast
for hydronic comfort applications. experience and on the strength of belonging to a large
multinational group such as Mitsubishi Electric in
The result is the most complete range of advanced terms of integrated R&D, operations and central
solutions providing enhanced usability, energy functions.

Leadership in smart heat pumps for 4 and 6 pipe systems Vast portfolio of
Control, Monitoring
and Optimisation
Extensive Range Complete range of systems
of Hydronic units rooftop units up to 350kW
and AHUs up to
from 1 to 4.549kW 100.000m3/h air flow 12 specialized
manufacturing hubs

Countless succesful projects worldwide


3 standard energy
efficiency settings
8 standard noise
reduction configurations

Sales network

Manufacturing
hubs or R&D labs
Climaveneta solutions for
comfort applications are
designed to provide even in the
most challenging residential,
office, hotel and retail projects:

Perfect Comfort Environmental Specific Solution


and Well-being Respect for each project

Ensuring a perfect control of Decreasing energy consumption, A vast range of highly configurable
temperature, humidity as well as of air cutting carbon emissions and making products, combined with solutions
quality and noise level, ideal comfort the most extensive use of renewable dedicated to each project, when even
conditions are ensured even in the sources are key elements of a high the highest configurability is not enough,
most demanding applications and quality HVAC, making a positive is key to delivering best comfort with no
challenging climate conditions. contribution to greener buildings and limitations on architectural choices,
better energy performance ratings. reduced footprint of technical systems
and no aesthetical impact.

Lowest cost Simplified Enhanced value of the


of ownership on-site operations real estate development

Thanks to cutting-edge solutions Climaveneta units apply a “plug & By reducing operational expenses due
designed around technological play” design approach that integrates to running costs and maintenance, as
innovation and sustainability in many functions traditionally provided well as by optimising initial investment
order to drive down initial by different systems, such as heating and opening the opportunity to benefit
investment, running costs and and cooling. They are equipped with for energy reduction and green
maintenance, and to increase the all options and accessories in order to solutions incentives, Climaveneta
total life cycle of the product. make on site operations rational, solutions are a key asset in making
simple and predictable, with countless new or existing properties more
advantages in project management. valuable and profitable.
CHILLERS

 Highest energy efficiency CONFIGURABILE


 Perfect indoor climate control R513A HEAT EFFICIENCY
RECOVERY
 Lowest noise emissions SET

Air cooled chillers


i-BX inverter scroll compressors 4,3 12,9 INVERTER SCROLL AXIAL PLATES

i-NX inverter scroll compressors 43,9 129 INVERTER SCROLL AXIAL PLATES

NX scroll compressors 39,2 327 SCROLL AXIAL PLATES

NX scroll compressors 159 352 SCROLL AXIAL SHELL&T.

NECS scroll compressors 334 885 SCROLL AXIAL SHELL&T.

FX screw compressors 140 1710 SCREW AXIAL PLATES SHELL&T.

i-FX (1+i) inverter screw compressors 567 1273 INVERTER SCREW AXIAL SHELL&T.

TECS2 inverter oil-free centrif. compr. 220 1324 INVERTER OIL FREE AXIAL EC FAN FLOODED

i-FX-G01 inverter screw compressors 447 1697 INVERTER SCREW AXIAL EC FAN SHELL&T.

NX-C scroll compressors 17,4 291 SCROLL PLATES


500 1000 1500 kW

Water cooled chillers


NX-W scroll compressors 38,1 398 SCROLL PLATES

FX-W screw compressors 124 401 SCREW SHELL&T.

FOCS2-W screw compressors 306 2416 SCREW SHELL&T.

FOCS3-W screw compressors 188 1693 SCREW FLOODED

i-FX-W (1+i) inverter screw compressors 532 1784 INVERTER SCREW FLOODED
TX-W inverter oil-free centrif. compr. 246 4549 INVERTER OIL FREE FLOODED
1000 2000 3000 4000 kW

Condenserless chillers
HE scroll compressors 4,7 32,4 SCROLL PLATES

NECS-ME scroll compressors 39,5 432 SCROLL PLATES

FOCS-ME screw compressors 79,2 2240 SCREW SHELL&T.


500 1000 1500 2000 kW

Air cooled chillers with free-cooling technology


TECS-FC inverter oil-free centrif. compr. 302 1693 INVERTER OIL FREE EC FAN FLOODED
500 1000 1500 kW

Air cooled chillers with evaporative free-cooling technology


TECS-EFC inverter oil-free centrif. compr. 300 1682 INVERTER OIL FREE EC AXIAL FLOODED
500 1000 1500 kW

SERIES Air and water cooled chillers with HFO 1234ze R 1234ze

FX HFO air cooled, screw compressors 235 1463 SCREW AXIAL SHELL&T.

i-FX-G04 air cooled, inverter screw compr. 383 1463 INVERTER SCREW EC FAN SHELL&T.

TECS2 HFO air cooled, inverter oil-free centrif. compr. 339 1017 OIL FREE EC FAN FLOODED

FX-W-G04 water cooled, screw compressors 93,1 373 SCREW EC FAN SHELL&T.

TECS2-W HFO water cooled, inverter oil-free centrif. compr. 340 1364 OIL FREE FLOODED
500 1000

SERIES Air and water cooled chillers with R513A R R513A

FX-G05 air cooled, screw compressors 140 396 SCREW AXIAL PLATES SHELL&T.

FX-G05 air cooled, screw compressors 288 1710 SCREW AXIAL SHELL&T.

i-FX-G05 air cooled, inverter screw compr. 479 1697 INVERTER SCREW AXIAL EC FAN SHELL&T.

TECS2-G05 air cooled, inverter oil-free centrif. compr. 218 1313 INVERTER OIL FREE AXIAL EC FAN FLOODED

FX-W-G05 water cooled, screw compressors 124 401 SCREW SHELL&T.

FOCS2-W-G05 water cooled, screw compressors 306 2416 SCREW SHELL&T.

FOCS3-W-G05 water cooled, screw compressors 188 1693 SCREW FLOODED

i-FX-W (1+i)-G05 water cooled, inverter screw compr. 532 1784 INVERTER SCREW FLOODED

TX-W-G05 water cooled, oil-free centrif. compr. 248 4466 INVERTER OIL FREE FLOODED

TECS-FC-G05 air cooled, oil-free centrif. compr., free-cooling 299 1671 INVERTER OIL FREE EC FAN FLOODED
1000 2000 3000 4000 kW

ADVANCED TECHNOLOGIES FOR HIGH EFFICIENCY


AND HIGH QUALITY AIR CONDITIONING SYSTEMS
Magnetic Levitation
Climaveneta’s leadership in air conditioning and heating is backed An extended range of chillers with magnetic levitation centrifugal
by over 45 years experience in the smart integration of premium compressors from 200kW to 4MW, both air source and water
technologies for the most challenging projects worldwide source, available also in free cooling and evaporative free cooling
versions, to deliver highest efficiency in every application.
HEAT PUMPS

 Operating limits up to -20°C CONFIGURABILE


 Hot water production up to 78°C
HIGH WATER
TEMPERATURE
HEAT EFFICIENCY
RECOVERY
 Highest energy efficiency SET

Air to water reversible heat pumps


AWR MTD2 XE scroll compressors 5,2 29,2 SCROLL AXIAL PLATES

i-BX-N inverter scroll compressors 4,2 35,1 INVERTER SCROLL AXIAL PLATES

i-KIR2-MTD inverter scroll compressors 4,03 12,5 INVERTER SCROLL EC AXIAL PLATES

i-KIR-MTD inverter scroll compressors 15,6 30,5 INVERTER SCROLL EC AXIAL PLATES

i-NRG inverter scroll compressors 14,7 INVERTER SCROLL EC FAN PLATES

AWR DHW2 XE scroll compressors 5,8 22,8 SCROLL AXIAL PLATES

AWR-HT scroll compressors 34 235 181 SCROLL AXIAL PLATES

MICS-N FFT scroll compressors 17,3 42,5 SCROLL AXIAL PLATES

NX-N scroll compressors 35,8 319 SCROLL AXIAL PLATES

i-NX-N inverter scroll compressors 40,9 128 INVERTER SCROLL AXIAL PLATES

NECS-N scroll compressors 48 339 833 SCROLL AXIAL SHELL&T.

NX-N scroll compressors 148 335 SCROLL AXIAL SHELL&T.

FOCS-N screw compressors 441 1162 SCREW AXIAL SHELL&T.

MICS-CN scroll compressors 17,3 30,3 SCROLL CENTRIF. PLATES

NX-CN scroll compressors 18 265 SCROLL EC FAN PLATES


200 400 600 800 1000 kW

Air to water heat pumps (heating only)


i-KI-MTD inverter scroll compressors 21,6 44,4 INVERTER SCROLL AXIAL PLATES

AW-HT scroll compressors 38 205 SCROLL AXIAL PLATES


50 100 150 200 kW

Water to water reversible heat pumps


WWR MTD2 scroll compressors 5,2 33,4 SCROLL PLATES

WWR DHW2 scroll compressors 5,1 34,8 SCROLL PLATES

NX-WN scroll compressors 37,5 396 SCROLL PLATES


50 100 150 200 250 300 350 kW

Water to water heat pumps (heating only)


WW-HT scroll compressors 27,5 109 SCROLL PLATES

EW-HT scroll compressors 70,2 279 SCROLL PLATES


50 100 150 200 250 kW

Water to water heat pumps reversible on the hydraulic side


WWH-HT scroll compressors 23,6 94,2 SCROLL PLATES

NX-W /H scroll compressors 38,1 398 SCROLL PLATES

FOCS-W /H screw compressors 87 298 SCREW SHELL&T.

FOCS2-W /H screw compressors 306 2416 SCREW SHELL&T.

i-FX-W (1+i) /H inverter screw compressors 532 1784 INVERTER SCREW FLOODED
500 1000 1500 2000 kW

Geothermal reversible heat pumps


BWR MTD2 scroll compressors 5,08 43,6 SCROLL PLATES
20 40 kW

Geothermal reversible heat pumps (heating only)


BW-HT scroll compressors 20,3 79,1 SCROLL PLATES
20 40 60 kW

SERIES Air and water source heat pumps with R513A R R513A

FOCS-N-G05 air source, screw compressors 441 1162 SCREW AXIAL SHELL&T.

FOCS2-W-G05 /H water source, screw compressors 306 2416 SCREW SHELL&T.

i-FX-W (1+i)-G05 /H water source, inverter driven screw compr. 532 1784 INVERTER SCREW FLOODED
500 1000 1500 2000 kW

R513A

Smart Thermal Energy Management Inverter Driven Compressor New G04 and G05 Series using green refrigerants
An innovative heat recovery system that allows The possibility to modulate cooling capacity results Following on vast experience in using green refrigerants,
the smart use of rejection heat from the industrial in increased efficiency as well as in the possibility to Climaveneta has already employed extensively green HFO
process for comfort heating and other effectively implement smart management solutions refrigerants such as HFO1234ze and R513A in many ranges,
neighbouring applications. such as active redundancy. in order to continue to be at the forefront with green best practices.
UNITS FOR SIMULTANEOUS AND INDEPENDENT
PRODUCTION OF HOT AND COLD WATER
 Highest efficiency CONFIGURABILE
HIGH WATER
in combined hot and cold water production TEMPERATURE EFFICIENCY
 Rationalized system design and reduced footprint SET

Air source heat pumps


NX-Q scroll compressors 43,9 169 SCROLL AXIAL PLATES

NECS-Q scroll compressors 142 311 SCROLL AXIAL PLATES

NECS-Q scroll compressors 332 850 SCROLL AXIAL SHELL&T.

ERACS2-Q screw compressors 199 826 SCREW AXIAL EC FAN SHELL&T.

i-FX-Q2 inverter screw compressors 443 1125 INVERTER SCREW EC FAN SHELL&T.
200 400 600 800 1000 kW

Water source heat pumps


NECS-WQ scroll compressors 48,4 412 SCROLL PLATES

ERACS2-WQ screw compressors 189 363 SCREW SHELL&T.


200 400 kW

SERIES Air and water source 4-pipe heat pumps with R513A R R513A

ERACS2-Q-G05 air source, screw compressors 199 826 SCREW AXIAL EC FAN SHELL&T.

i-FX-Q2-G05 air source, inverter, screw compressors 443 1125 INVERTER SCREW EC FAN SHELL&T.

ERACS2-WQ-G05 water source, screw compressors 189 363 SCREW SHELL&T.


200 400 600 800 1000 kW

ROOFTOP UNITS

 Widest range and complete configurability


 Perfect thermoigrometric control HEAT
RECOVERY
 Maximum flexibility in the air flow management

Air to air rooftop unit, cooling only


WSM-T air cooled 23,4 422 SCROLL PLUG FAN REF.BOOST. PLATE

WRX-T air cooled 50,8 240 SCROLL PLUG FAN REF.BOOST. PLATE ROTARY THERMOD.

WSM2-T air cooled 81,1 182 SCROLL PLUG FAN REF.BOOST. PLATE ROTARY
100 200 300 400 kW

Reversible air cooled rooftop unit


WSM air cooled 24,4 317 SCROLL PLUG FAN REF.BOOST. PLATE

WRX air cooled 50,8 240 SCROLL PLUG FAN


WSM2 air cooled 81,1 182 SCROLL PLUG FAN REF.BOOST. PLATE ROTARY

WTA heat recuperator with integrated refrigerant circuit 13,2 76,3 SCROLL EC FAN PLATE THERMOD.
100 200 300 kW

ANCILLARY PRODUCTS

Condensing units
BRAT-MC / HCAT / MCAT 5,61 351 SCROLL RECIPR. AXIAL
100 200 300 kW

Remote condensers
NHCR / NCE / FCE 7,90 929 AXIAL
200 400 600 800 kW

HIGH WATER
TEMPERATURE

V-AIR VPF High Water Temperature


High efficiency EC technology fans are extensively The VPF (Variable Primary Flow) dynamically Climaveneta vast experience in high leaving water temperature
adopted for their advantages with 15% energy optimizes the unit’s thermoregulation for variable applications is proven by a complete range of technical
reduction compared to traditional EC fans. flow operation, thus ensuring both the highest solutions in these areas, to cope with any heating requirement,
pump energy savings and chiller stable operation. from 6 pipe applications to high temperature heating.
HYDRONIC TERMINALS

 Fan coil range for residential and commercial applications


 Complete range of accessories
FANCOIL
 For exposed or concealed installation

Fan coils
a-LIFE3 residential or commercial fan coil unit 1,41 6,45 2 PIPES 4 PIPES CENTRIF.
i-LIFE2 residential or commercial fan coil unit 1,82 7,50 INVERTER 2 PIPES 4 PIPES CENTRIF.

a-LIFE2 HP fan coil unit for commercial applications 2,88 8,60 2 PIPES 4 PIPES CENTRIF.

i-LIFE2 HP fan coil unit for commercial applications 2,00 8,76 INVERTER 2 PIPES 4 PIPES CENTRIF.

i-LIFE2 SLIM residential fan coil unit 0,76 3,76 INVERTER 2 PIPES TANGENT.
2 4 6 8 kW

Hi-wall type terminals


MHD2 high-wall terminals 2,15 4,63 2 PIPES TANGENT.
2 4 kW

Cassette type terminals


a-CXW cassette terminal 3,20 11,3 2 PIPES 4 PIPES CENTRIF.

i-CXW cassette terminal with inverter technology 4,56 9,42 INVERTER 2 PIPES 4 PIPES CENTRIF.
4 6 8 10 kW

Ducted type terminals


a-HWD2 ducted type terminal 5,87 21,9 2 PIPES 4 PIPES CENTRIF.

i-HWD2 ducted type terminal with inverter technology 6,20 22,3 INVERTER 2 PIPES 4 PIPES CENTRIF.
10 15 20 kW

Heat recuperators
HRD2 heat recuperator 3,68 31,4 EC FAN PLUG FAN PLATE
10 20 30 kW

AIR HANDLING UNITS

MWZ compact air handling unit


WIZARD fully configurable air handling units 600 115400
20000 40000 60000 80000 100000 m3/h

CONTROL, SUPERVISION
AND OPTIMISATION SYSTEMS

Group devices Supervision and monitoring systems

 ClimaPRO  IDRORELAX
Plant Room Optimisation System Monitoring and supervision system.
Plant Room Optimiser for real time,
smart management of energy indeces
for the single units and the entire
plant room.

 MANAGER 3000
Specialized group control. Human Machine Interfaces

 SEQUENCER  KIPlink
The ultimate solutions for supervision, Control interface for smart
remote monitoring, service, and phones and tablets.
preventive maintenance.

HEAT CONFIGURABILE
EFFICIENCY
RECOVERY SET

Proprietary Control Logics Leading Heat Recovery Technology Configurable Efficiency Set
The performance of Climaveneta units is Climaveneta is a recognized leader in heat recovery applications The willingness to cope even with the most
enhanced also by their control logics, based on a and in its product employs in the most effective way all the demanding energy efficiency projects is reflected by
proprietary logics and know-how, deployed in a most performing solutions such as thermodynamic, plate and the availability of 3 energy efficiency standard
vast range of solutions. rotary heat recovery as well as refrigerant booster. configurations in most hydronic units.
OVERVIEW COMFORT APPLICATIONS_ENG_05-2019

Head Office: Via Caduti di Cefalonia 1 - 36061 Bassano del Grappa (VI) - Italy
Tel (+39) 0424 509 500 - Fax (+39) 0424 509 509

You might also like