INTRODUCTION Motor-Machine combination needs instant protection ‘ainst unforeseen overloads. Te JIYASHREE Load Monitor performs this duty admirably. It can actuate aa a5 scon as the preset Deine «= 2 power level ofan Induction Motor exceeds. It can also TOG at 12 The closest best guard of motor driven machines) Electronic Shear Pin to switch OFF the motor. Protects the motor against burning due to overload, riven machines like Mechanical Presses, Ball Mis, Protects the machine against mechanical jamming Crushers and Mixers that are subject to frequent and\ "Detects overioad 2s well os under load je euerenios, = Simple to connect-Easy to set. In addition, the monitor can detect Under-Load Condition af an Induction Motor, which may occur when Griving Deep well pumps and issueasignal warning and STANDARD SPECIFICATIONS Hac ssseeinsrecearashc Supply Voltage : 415V AC,SO Hz (Across R-Y Phase) APPLICATIONS Signal Current: Max, 5A (Burden SVA Max.) "Productivity Aid’ for @ skilled machine tool operator. from B-Phase Satety monitor for small / medium / large Induction Initial Delay = 1-20s Motors driving a variety of loads such as Pumps, Nuisance Delay : 1-20 s ‘Compressors, Machines Tools, Crushers, Ball Mills and sensing Range: This is calibrated as per motor kW. eal Output Contacts : 1NO+INC, 1C/0, 2C/0 FEATURES Contact Rating: 6A resistive @ 240V AC. + Monitors under/over ood. Operating Temp.: 55°C Max Monitors true kW load on Induction Motor drives. + Display racy STANDARD MODELS PLC Compatibie. BASIC TYPE | DUTY crecurt TYPE + Provides 4-20 ma /RS-485 output. ELM 9311 —~[anaiog + Instantaneous or delayed actuation possible. FLM9313 | Under-Over Load | Analog ELM 9361 ad pC based WORKING PRINCIPLE i = 4 It senses the power of an Induction Motor by sensing LELN 9363 _| Under-Over Load | uC based and combining the mator current, voltage ard power factor and actuates an output relay, elther instantly or SELECTION CHART after preset time delay. This is in sharp contrast with the action of thermal O/L relay which is sluggish, |_EL ms [a4 Inacaurate and comparatively crude device and hence incapable provicing "Complete Protection” Circuit Technique CONSTRUCTION Ts Descrete! ‘These are available in MS / Plastic enclosure to suit 1P- Electronics 30 grade of protection for mounting either inside panel : Micro controller fr flush on panel front: Enclosures with 1P-65 grade are baad also available, ‘OPERATION Operation / Duty ‘The output relay is initially OFF and remains OFF during 3 : over-Load start-up. The signal current amplitude is continuously 3 «incr toag ‘monitored. The relay actuates in case of over load. \ Manual reset facility can be provided if desired 3:Under-Over Load Contact Combination 11: 1NOHING 22 : 2NO+2NC AC : 1¢/0 2€ :2c/0 Enclosure MS: MS Fabricated 1P-30 A :Cast Al 1P-65 PL : Plastic-ABS IP-65, PC : Polycarbonate 1P-65 2 LSPA LU Coat 1 “Single Phase / Three Phase models. // Protection against over/under current. “a Microprocessor based models. | Single unit to monitor multiple motors, = 4-20 mA output for remote metering, = Simple to connect-Easy to set. NT MONITOR Series ECM 921/ECM 926 INTRODUCTION Induction motors the heart ofan Industry Faure of motor ‘ue to over-current can lead to non-productive down time. Motors are generally provided with over temperature protection but the same isnot useful for protecting motors from high currents of short duration. ‘The JAYASHREE ‘lecironicCurent Monitor protects motor relably es Conveyors, Crushers, Bucket Elevators, Fans, Blowers and STANDARD MODELS See ene rece na I WORKING PRINCIPLE ECM 9211 | Over-load [Analog Stary Rone teliere Wenn ose ae ‘reference and output relay is actuated at desired value. Initial osiz Under-Qver Load | uC based by-pass delay is proved to take care of transient conditions ‘during motor start-up. ‘CONSTRUCTION OPTIONAL FEATURES: "© Digital Analog Display ‘These are avaiable in MS / Plastic enclosure to suit 1-30 wm 4-20maoutpat ‘rade of proton for mounting ether inside panel orfush jan ‘on panel front. Enclosures with IP-65 grade are elso avaliable. s ‘OPERATION ‘The output relay is initially OFF and remains OFF during start~ SEE up. The sgl current ampituse s continuous montored. [ecu=92 [a [a ws a ‘The relay actutes In case of ver Curent. Manual reset faclty canbe provide dese t q STANDARD SPECIFICATIONS Circuit Technique | | Contact Combination ‘Supply Voltage : 240 / 110 / 24 V AC/DC 1: Descrete 11: INO+INC Signal Curent: Max.5A Electronics 22: 2NO+2NC Inital Delay: 1205 6 : Micro controler Ac 14/0 Nulsance Delay : 0.5-20 s based 2c 1240 Seng Range: 0-120% of input signal Output Contacts: IND#INC, 1¢/0, 2/0 ‘Operation iaey Enclosure Contact Rating: 6 A resistive at 240 V AC. ae MS:MS Fabricated 1P-30 CCA :Cast Al 1P-65 ee oe 2:Under-Load PL : Pil “ABS IP-65 Sse ae 3:Under-Over Load saat Relay ON Green PC Polycarbonate IP-65 JAYASHREE ELECTRON PVT. LTD. Works EL-34, Block, MLDC. Bhosar, Pune ~ 417 026, NDIA. Tel: +-91-20 -27121295, 27121528. Fax: 020 - 25437253, mall: ayashree_electron@vsni.net Web: wuvaashres cin

You might also like