You are on page 1of 28

PRELIMINARY DRAWING

DEVELOPMENT DRAWING

BATUBULAN HOUSE
BATU BULAN
GIANYAR - BALI

2020
5 4 3 2 1
A B C D E F G
- - - - -

1
-
10
POND
STORAGE

BEDROOM
D
102

TELAJAKAN
02

W
- 01
D
9 W 02
02

LIVING
DINING SPACE D

TERRACE
AREA 01

BACK
YARD D
GARDEN
A
03
- -
8

3
- D D
7 02 02 GARAGE
BATHROOM BEDROOM
SERVICE KITCHEN 101
AREA
G
01

W
02

W W
03 04
4
- G
6 02

- PLAN LEVEL 1
A101

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A101 -
5 4 3 2 1
A B C D E F G
- - - - -

1
-
10

W
SANGGAH 05 LIVING
SPACE

BALCONY
- D
9 D 04
02

D D
02 02
A
- BEDROOM -
BALCONY 201
8
D
06 D
3

BALCONY
02
- D
7 BATHROOM 02
D
202 05

BEDROOM
202

BATHROOM
201

W W
4 04 04

-
6

- PLAN LEVEL 2
A102

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A102 -
5 4 3 2 1
A B C D E F G
- - - - -

1
-
10

-
9

A
- -
8

3
-
7
SPACE
TANDON

4
-
6

- SITE PLAN
A103

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A103 -
5 4 3 2 1

- ELEVATION A
A201

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A201 A
5 4 3 2 1

GARDEN
GARAGE FFL -0.200
FFL -0.400

FFL -0.730

- SECTION 1
A202

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A202 A
5 4 3 2 1

FCL +3.150

BEDROOM 201 CORIDOR


FFL +3.600 FFL +3.600

FCL +2.600

BEDROOM 101 LIVING SPACE


FFL ±0.000 FFL ±0.000

- SECTION 2
A203

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A203 A
5 4 3 2 1

FCL +3.150

FCL +2.400

BATHROOM 201 BEDROOM 201 CORIDOR


FFL +3.560 FFL +3.580 FFL +3.600 FFL +3.600

FCL +2.400

FFL +1.080

BATHROOM 101 LIVING SPACE


FFL -0.040 FFL -0.020 FFL ±0.000

- SECTION 3
A204

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A204 A
1 2 3 4 5

FCL +3.150

FCL +2.400

LIVING SPACE BEDROOM 202 BATHROOM 202


FFL +3.600 FFL +3.600 FFL +3.600

FCL +2.600

BEDROOM 202 DINING AREA KITCHEN


FFL ±0.000 FFL ±0.000 FFL ±0.000

- SECTION 4
A205

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A205 A
1 2 3 4 5

DAK TANDON AIR


FFL +7.020

FCL +2.800

SANGGAH BALCONY BEDROOM 202


FFL +3.600 FFL +3.550 FFL +3.600

FCL +2.600

STORAGE SERVICE AREA


FFL ±0.000 FFL -0.050 BACK YARD FFL -0.100
FFL -0.250

- SECTION 5
A206

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A206 A
A B C D E F G

FCL +2.800
FCL +2.550

BALCONY BEDROOM 202 BEDROOM 201 BALCONY


FFL +3.550 FFL +3.600 FFL +3.600 FFL +3.550

FCL +2.750
FCL +2.600

BACK DINING AREA LIVING SPACE TERRACE


YARD FFL ±0.000 FFL ±0.000 FFL -0.050 GARDEN
FFL -0.250 FFL -0.200
ROAD
FFL -0.650

- SECTION 6
A207

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A207 A
A B C D E F G

FCL +2.550
FCL +2.400 FCL +2.400

BATHROOM BATHROOM
BEDROOM 202 202 201 BEDROOM 201 BALCONY
FFL +3.600 FFL +3.580 FFL +3.580 FFL +3.600 FFL +3.550

FCL +2.750
FCL +2.600
FCL +2.400 FCL +2.350
FCL +2.300

KITCHEN BATHROOM 101 BEDROOM 101


FFL ±0.000 FFL -0.020 FFL ±0.000
GARAGE
FFL -0.400 ROAD
FFL -0.650

- SECTION 7
A208

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A208 A
A B C D E F G

FCL +2.750

ROAD
FFL -0.650

- SECTION 8
A209

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A209 A
G F E D C B A

FCL +3.150

BALCONY LIVING SPACE


FFL +3.550 FFL +3.600 FFL +3.550

FCL +2.750
FCL +2.600
FCL +2.550

TERRACE LIVING SPACE BEDROOM 102


GARDEN FFL -0.050 FFL ±0.000 FFL ±0.000 FFL -0.050
FFL -0.200
ROAD
FFL -0.650

- SECTION 9
A210

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A210 A
G F E D C B A

FCL +3.150

BALCONY LIVING SPACE SANGGAH


FFL +3.550 FFL +3.600 FFL +3.600

FCL +2.750 FCL +2.700


FCL +2.600 FCL +2.600

TERRACE LIVING SPACE BEDROOM 102 STORAGE


FFL -0.050 FFL ±0.000 FFL ±0.000 FFL ±0.000

ROAD
FFL -0.650
FFL -0.730

- SECTION 10
A211

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD CONTRACTION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A211 A
A B C D E F G

STORAGE BEDROOM
102

DINING LIVING
BACK SPACE
YARD AREA

SERVICE KITCHEN BATHROOM BEDROOM


AREA 101

- FOOTPLAT PLAN
A301

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD COORDINATION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A301 A
A B C D E F G

STORAGE
BEDROOM
102

DINING LIVING
BACK SPACE
YARD AREA

SERVICE KITCHEN BATHROOM BEDROOM


AREA 101

- FOUNDATION & TIE BEAM PLAN


A302

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD COORDINATION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A302 A
A B C D E F G

BALCONY
SANGGAH LIVING
SPACE

BEDROOM
201
BALCONY

BALCONY
BEDROOM
202 BATHROOM
202

BATHROOM
201

- RING BEAM PLAN (TO LV.2)


A303

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD COORDINATION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A303 A
A B C D E F G

- RING BEAM PLAN (TO LV.3 DAK)


A304

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD COORDINATION 30-08-2020 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A304 A
- DETAIL STRUKTURE
A305

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A DD DD COORDINATION 30-08-2020 1:15 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:30 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A305 A
NOTES :

1. FOR DOOR
DIMENSIONS REFER
TO DOOR SCHEDULE

2. FOR HANDING REFER


TO ARCHITECTURAL
FFL +1.000
FLOOR PLANS

3. ALL GLASS TO BE
CLEAR TOUGHENED
GLASS UNLESS NOTED
OTHERWISE
FFL ±0.000
4. ALL DOOR HANDLES
CENTERED AT 1000
ABOVE F.F.L. UNLESS
NOTED OTHERWISE

5. DOOR HARDWARE
SHOWN IS INDICATIVE
ONLY. REFER TO
IRONMONGERY
SCHEDULE

6. 5 MM SHADOW LINE
G.01 G.02 D.01 D.02 D.03 WHERE TIMBER
LOCATION ENTRANCE LOCATION TO SERVICE AREA LOCATION ENTRANCE LOCATION BEDROOM, BATHROOM, STORAGE LOCATION DINING AREA MEETS MASONRY
FRAME FINISH METAL FRAME FINISH METAL FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER
WALL

LEAF FINISH METAL & TIMBER LEAF FINISH METAL LEAF FINISH CLEAR GLASS LEAF FINISH SOLID TIMBER LEAF FINISH CLEAR GLASS
SOLID TIMBER SOLID TIMBER
PANEL

HARDWARE - HARDWARE - HARDWARE - HARDWARE - HARDWARE -

MISC QTY 1 MISC QTY 1 MISC QTY 1 MISC QTY 9 MISC QTY 1

D.04 D.05 D.06


LOCATION BALCONY LEVEL 2 LOCATION BALCONY BEDROOM 201 LOCATION BALCONY BEDROOM 202

FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER

LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS

HARDWARE - HARDWARE - HARDWARE -

MISC QTY 1 MISC QTY 1 MISC QTY 1

- DOORS SCHEDULE
A401

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A401 -
NOTES :

1. FOR DOOR
DIMENSIONS REFER
TO DOOR SCHEDULE

2. FOR HANDING REFER


TO ARCHITECTURAL
FLOOR PLANS

3. ALL GLASS TO BE
CLEAR TOUGHENED
GLASS UNLESS NOTED
OTHERWISE

4. ALL DOOR HANDLES


CENTERED AT 1000
ABOVE F.F.L. UNLESS
NOTED OTHERWISE

5. DOOR HARDWARE
SHOWN IS INDICATIVE
ONLY. REFER TO
IRONMONGERY
SCHEDULE

6. 5 MM SHADOW LINE
W.01 W.02 W.03 W.04 W.05 WHERE TIMBER
LOCATION ENTRANCE LOCATION BEDROOM 101 & 102 LOCATION KITCHEN LOCATION BATHROOM LOCATION LIVING SPACE LEVEL 2 MEETS MASONRY
FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER FRAME FINISH SOLID TIMBER
WALL

LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS LEAF FINISH SOLID TIMBER CLEAR GLASS

HARDWARE - HARDWARE - HARDWARE - HARDWARE - HARDWARE -

MISC QTY 1 MISC QTY 2 MISC QTY 1 MISC QTY 3 MISC QTY 1

- WINDOWS SCHEDULE
A402

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A402 -
A B C D E F G

1
POND

STORAGE
BEDROOM
102

TELAJAKAN
2

LIVING
SPACE

TERRACE
DINING
BACK AREA
YARD GARDEN

GARAGE
BEDROOM
BATHROOM 101
KITCHEN
SERVICE
AREA

- PLUMBING LV.1
A711

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 COORDINATION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A711 -
A B C D E F G

LIVING
SANGGAH SPACE

BALCONY
2

BALCONY
BEDROOM
201
3

BALCONY
BEDROOM BATHROOM
202 202

BATHROOM
201

- PLUMBING LV.2
A712

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 COORDINATION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A712 -
A B C D E F G

1
POND

STORAGE
BEDROOM
102

TELAJAKAN
2

LIVING
SPACE

TERRACE
DINING
BACK AREA
YARD GARDEN

GARAGE
BEDROOM
BATHROOM 101
KITCHEN
SERVICE
AREA

- ELECTRICAL LV.1
A721

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A721 -
A B C D E F G

LIVING
SANGGAH SPACE

BALCONY
2

BEDROOM
BALCONY 201
3

BALCONY
BEDROOM BATHROOM
202 202

BATHROOM
201

- ELECTRICAL LV.2
A722

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A722 -
A B C D E F G

1
POND
STORAGE

BEDROOM
102

TELAJAKAN
2

LIVING
DINING SPACE

TERRACE
AREA
BACK
YARD GARDEN

GARAGE
BEDROOM
BATHROOM 101
SERVICE KITCHEN
AREA

- LIGHTING LV.1
A731

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A731 -
A B C D E F G

LIVING
SANGGAH SPACE

BALCONY
2

BALCONY
BEDROOM
201
3

BALCONY
BEDROOM BATHROOM
202 202

BATHROOM
201

- LIGHTING LV.2
A732

General Notes: Rev Dwn Chk Revision or reason to issue Date Rev Dwn Chk Revision or reason to issue Date Client Architect Structure Engineer Services Engineer Project Title Scale Drawing Title
A - - COORDINATION - 1:25 @ A1
Do not scale from drawing. Use marked dimensions. PLAN
To be read in conjunction with all other Consultant's drawings. - - 1:50 @ A3
Batubulan HOUSE North Point Project Number Drawing Status
The Architect / Engineers to be immediately notified of any KA Denpasar Denpasar Denpasar
GIANYAR
discrepancies. 125 CONTRACTION
BALI
Copyright on this drawing retained by the Architect / Engineers.
INDONESIA Drawing Number Issue Number
A732 -