You are on page 1of 147
r TP XC AS (7NM ; : me { FAW OG | i | | ele 4g, MD Uy (dC. vanced Technology ~ for the - 8 KOOMEY INC. 0 7 47 fon Cataloe 1980-18: Tsant te tke this opportiinity to let all my friends and associates in the indus- $ try Seem that I Rave formed a company named KOOMEY INCORPORATED ‘ Tam no longer asociated in any way with NL Petroleum Services (formerly ‘Stewart & Stevenson Oil Tools). As you probably know, the Koomey line of Blowout Preventer Control equipment was developed under my management and direction at Stewart & Stevenson Oil Tools. This firm was purchased by NL Petroleum Sei vives in 1978. [resigned January 31, 1979 to form KOOMEY INC. We are now manufacturing Blowout Preventer Controls forland, jackup and platform rigs, as wellas semis and drillships. KOOMEY INC. has a complete inventory of spare partsas well asexcellent service capability for both land and subsea Blow- i ‘out Preventer equipment. KOOMEY ING. introduces our new TYPE '80 technology for Blowout Pre- yenter Control equipment for the 19805. This TYPE.’S0 technology includes: ee pe 1. Super Sixty and Big Sixty air operated hydraulic phinger pumps with tungsten carbide valve seats, Pages 20-25. 2. Super sensitive pressure reducing and regulating valve that controls Hydril, Shaffer and Cameron type “D” annular blowout preventers, Page 61 3. Platform BOP contol systems with a Control System Kecorder (CSR) to record all activities relating to the BOP control system, Pages 52-55. 4. Buoyant “field removable” guided float type accumulators j especially for extremely cold or hot climates (patent pending). Page 16. 5. Type’80 gasoline/diesel operated hydraulic plunger pumps } (WELPRO) for use on workover rigs that do not require air or i electric power for operation ofa BOP control system. Pages 45-48. \ 6. Weighted float accumulator—less chance of nitrogen precharge loss (patent pending). Page 17. ‘Type ’80 Reverse Osmosis Watermakers—compact plants specifically designed for offshore installation. Pages 69-76. Allof these technological advances are offered in our TYPE.'80 equipment Bi designed for the eighties. We at KOOMEY ING. are ready to supply and service your needsin all. areas of the world including our headquarters at 9997 Hempstead Road, Houston, ‘Texas and our KOOMEY U.K. LTD. facility in Abereleen, Scotland. We invite you to visit both of these facilities and see our full fine of products. You'll find quality with courtesy—you have our word on it!!! Sincerely, Paul G. Koomey ‘ea INDEX EQUIPMENT Accumulator unit, bladder type ‘Accumulator unit, guided float type Accumulator unit, special ‘NeomsticBackep system Cable, air Cable, eleeric (Cie aber optic Cold elimate control system Grown Block Saver (CBS) Diverter controls Fluid, BOP control Hose, BOP control Tides, plteral i Installation, BOP control system - Interconnect assemblies Junction bos, ait ‘Koomey Sprayline 40 Airless spray pumps ‘AirMaste spray pumps Maintenance, BOP control system Manifold, "M’ series Manifold, "P" series Manifold, special panel mouated Manifold," W" series (workover) Mixing system Monitor; BOP control (recorder) Nitrogen backeup system anel, at Panel, diverter Panel, electric Panel, hydraulic (old climate) Choo arts inde, Pipe rack Platform control system Pamp,air operated Pump, clecriedriven Pump, hydraulic operated (WE! Recorder (monitor) Shuttle valve manifold Sizing, accumulator volume ripper Subsea BOP control system Swivel int asscimblics Tyblcd erases Testunit Watermaker, reverse osmosis: R.O-—-Conteol panel R.0.- Hollow fiber R.O— Pretreatment R.O—Prinaiples of. KO Pimps R.O— Schematic R.0—System description Workover control systems SPECIFICATION TABLES Accumulator modules Blowout preventers Cable, air & elecric Hose, subsea Junction boxes Manifolds, une mounted Manifolds, skid mounted. Manifolds workover Nitrogen backup systems Panels, air a Panels, electric Pipe racks Pumps, air operated Buns elev ie divest Pumps, gasoline driven Pumps, hydraulic (WELPRO) Swivel joint modules .. Workover contro systems PRO) 2, 83 42,44 2 779 80 58.92 26,2720 36, 26429 4 46 6s 54 35 36,37 60 45,4048 Ef 2 10 a1 62 a 60 50,57 6 a B 70 2 a INTENTS OPERATION, INSTALLATION & MAINTENANCE (BOP CONTROLS) Bladder replacement Installation Maintenance checklist recharging accumulators Scher ramlatne sini Schematic, ait panel Shematic electric panel Schematic. test unit, Schematic, workover unit PARTS Hie: 103 11 gaton Accor Mader Spe erie top cae Beata guia tos arse Superforty performance eee erorome ee iio Garse 30 (51) sve 60603) finders. alr and hydra Perea Serer puns. ees Bileeai Cafes nt and bdr ee cen Labrie ai Meters eerie Fe pars Hye ulic (cd) Pampa ac operated hydraulic Supertonty 0s). Big snp (0:1)... Supersiety (601, 060) 60 (60:1) Test (2003), Te aos) Tet Tutnp, ida dcivenlydentc Phin dtblex and tsplex 25 hp) Pumps: triplex (0-60 bp Fans ples Cpe Regulator, hytraulic presture a Ar ere 4 Mana operated 36" Manual operated Aacpenal sir Cereal IY Mirnil oper $6 Manual operated Hedi operted He Hyatraulic operated We Ale operated Iie Hsdiulicopericd Eesiees spigele Erase eee ee ee Cae Vera Vat cheek Yate paral seeey comol Vie ole Vite segilcng Varese ieee Eine Nahe onale GENERAL INFORMATION ges, Wot repress Gere uss, Kote) Tne Terms & conditions of sale 90,91 82,85 88,89 99 8 85 87 a7 on 96 98, 99 101 105, 105, 107 109 138 146, 141 148 152 135 139 15 132 135, 1 100, 102 39) 193 104, 105, 106, 2108 no i 12 113 114, 115, 116,117 118 138 125 136 139 131 133 19 120 135, re 137 138 152 2156 137 134 2131 140 D133 10, 133, see Regulator 2138 133 142 140 146 47 15 4408 INDEX ‘TYPE RO" KOOMEY INC. PICTORIAL INDEX MANIFOLD MODULE SEE PAGES 26-34 SHUTTLE VALVE MODULE SEE PAGES 42 & 43 PIPE RACK MODULE SEE PAGES 42 & 43 ‘SWIVEL JOINT MODULES ‘SEE PAGES 43 & 44 AIR CABLE MODULE SEE PAGES 43 & 44 ACCUMULATOR MODULE! SEE PAGES 12-19 ELECTRIC PUMP MODULE ‘AIR PUMP MODULE SEE PAGES 24-25 SEE PAGES 20-23 Il VEE Qyy INDEX 1 OW KOOMEY INC. SPARE PARTS INFORMATION SEE PAGE 94 CROWN BLOCK SAVER SEE PAGES 58-59 FIXED JUNCTION BOX SEE PAGES 42-43 HOSE JUNCTION BOX > SEE PAGES 42.43 DRILLER’S PANEL SEE PAGES 36 & 40 4 WORKOVER CONTROL SYSTEMS SFF PAGES 45.28 COLD CLIMATE CONTROL SYSTEMS | SEE PAGES 49-51 PLATFORM CONTROL SYSTEMS: SEE PAGES 52-55 4410 BLOWOUT PREVENTER CONTROLS KOOMEY INC. QUICK REFERENCE TABLE ACCUMULATOR VOLUME RECOMMENDATIONS. Cameron BOP Stack 6 3000 | 73hs u = 4 8 = = = = 6 5,000 | the u D 4 8 5 3 | a5 19 The 10,000. | 736 U D 4 a | og zo |e to 3.000 4 u = 10 20 = = es 3 30 5,000 Ww u D 0 20 7 37 a7 57 it 10,000, u v D w 20 31 St 61 nm 12 3,000 1355 U = 7 3 = = — = 1380 5,000 13% u o 7 34 a7 70 87 103 1389 10.000 | 1358 vu D 47 34 55 83 405 sai | 2AVe 2,000 | 214 fu = 25 Sipe = = = Hydril BOP Stack 6 3.000 Tie | Man. [GK a 8 a 6 20 3 6 5,000 mae | Man. | GK 4 8 12 19 23 26 8 3,000 8 Man. “|” Gk 6 12 18 25 30 36 feed: 5,000 3 Man. | Gk 6 12 a 32 38 44 10) 3,000) Ty ‘Auto| GK 12 2 23 45 57 6B 10 5,000 4 futo | Gk 2 B 20 53 64 15 1 10.000 4 fata | OK 30 cs 6 150, 192 230, [1388 | 5.000 13% | Auto | Gk 18 6 Py ‘20 a a 19% | 10,000. 135% | Auto| GK 38 78 404 181 220 259. 20 2.0007 | era | auto | Msp. 2, 4 84 147 174 200) ‘Shaffer BOP Stack 6 3000] aie | We TS 2 a © 7 e 2 6 5000 | THe | twe | © 4 8 4 21 2 28 The 10,000 The | ws |S. 49 8 52 90 109 128, 10 3,000 1" ws |S. 6 1 3 44 43 54 10 5,000 " ws | 8 8 8 56 4 90 se 1 10,000 ri suo} os | a5 50 92 142 168 191 1388 so00 | 1386 Su 3 7 38 a 104 a1 137 13% | 10000 | 195s. st s 35 0 set 190. 225 260 20 2000 [aim [ws | os | st | 102 86 199 250 301 ‘CameroniHiydril BOP Stack 5 3,000 Tite ‘Cameron-Ua HycribGk 6 ra 2h 8 500 | 7iks Cameron-U & HycrikGK 19 3 a 0 3,000 11 ‘Cameron-U & Hycrikak 43 52 io 10 5,000 "1 Cameror-U & HycrikGK = 20 7 4 10,000 1 Cameror-U & HyatlLGk 85 105 115 1958 5,000 1988) Cameror-U & HydikGk | 8 104 121 1388 | 10,000 | 135% Cameron-U) & HytikGk 137 154 170. Lat 2,000 | 21% Cameror-U & HyctikGk 144 183 194 Note: The accumulator volume show in each colamn was arrivod aby using Boyle's Law plus S0% safety factor and rounded upto the nearest {gallon To determine the numberof accumulators required, simply cvide tho ACCUMULATOR VOLUME by the ACTUAL LUID CAPACITY othe Specie accumulator, EXAMPLE 104 — Accumulator Volume require (gallons) fr 1334-5000 ps wth 3 Cameron Rams and t Hycil Bao, 30 — Actual Flu Ganaaly ntantt gaan accumulator 10.4 or 1thelevan gallon accumulatrs required. NOTE #2: WE RECOMMEND A 100% SAFETY FACTOR WHEN OPERATING IN VARIOUS AREAS OF THE WORLD THAT HAVE SEVERE (OF HAZARDOUS ORILLING CONDITIONS, All gallons shown to close each preventer or combi ‘manufacturers. 6 jon of preventers are based on information received from the preventer 4a XY KOVIN™ aN) BLOWOUT PREVENTER CONTROLS 4 OY KOOMEY INC. QUICK REFERENCE TABLE ANNULAR (BAG) TYPE PREVENTERS ‘ameron 0 Tool DMsion a 5000 The ao is me) 8 10000 ime S00 2s D 5000 1 3000 488 . 10,000 u 300 | 08 5 S000 ioe 000 1038 8 10.000 iar | aoe 4635 oe = a) ee ) Gk 6 5,000 16 3.86 ) & The ‘000 Te oe & The 15,000 De 1100 | 2 3.000 3 ae § 5000 e | oe : stco) : | 230 10 000 8 78 } ia S000 " ag: | i 19000 u 2510 200 oe ed 50m ies se \ ‘000 ioe ne 3000 3} ane Som te Bid | a } 5000 18 | 1976 | 5000 a 20 eu 5000 1 4400 NSP 7 285 mse ° ae } Mar 8 340 MSP ya ys] hse | 00 | usr | E | [eso | zao St 3 300 Th i300 a7 ai epnetes ¢ 5100 ie 100 te a OP Te 19.000 Te +500 vm 365 | 2 3000 $ 500 723 2a 3 Son ° 500 1805 er rH 30000 4 +500 400 678 0 Sona 4 500 eer 4 u sooo 0 500 2088 287 1388 5,000 1355 i1s00 2358 7a | iF 10000 | 3H 1500 i016 3284 tee S000 ie 1500 228 Bei je S00) We 1300 818 ane 2 200 Be 1500 2 602 amu 000 bine 300 oar 776 « 3 3,000, i k a Stoo K ‘ 500 KD. A Ses and Types pa KL 2 F000 2 war s00 Bo] fi 2 5000 3 Wat 500 =o, & 1 2 1.000, Wel 500 73] KL 2 20000 23 W500 20/5 KR » 000 252 Wat +500 sro] |G KF 50 2000 ba Wa 300 zn) TORUS: Sr ee 2.000 +50] TonuS 6 | ain ato eH | TORUS 5 ‘3000 ad 225 TORUS 8 000 3.00 825, NOTE: Coniact Koomay Ine for specifications on preventer that are not lita 4412 BLOWOUT PREVENTER CONTROLS | 4 { KOOMEY INC mL iL PIE, Qu/ QUICK REFERENCE TABLE RAM TYPE BLOWOUT PREVENTERS BOWEN Sa ae AT AV Dae %Y/)\" F fe ig be 2 a é oa ge | Ae so | Uae oe os Sn cameron g 3 j oder 2 ogi f i & comme | é “= te oe | om: a: | — : | ue: 2 ee a vse | Bs ae : a eau view | Be See ee cy 30 on = Bee is i red = $ Sue = : alee oe : oe x 8 ee 5 S i 4413 BLOWOUT PREVENTER CONTROLS KOOMEY ING, QUICK REFERENCE TABLE RAM TYPE BLOWOUT PREVENTERS " a —= Mt ory some zi ee =e ear " 1180 a8 & |S ve (G8 ae | we | Ee | woods 2 | [te |e e ame 3 tea aay i 3S os = |e |) Be ue | 3 m |e | Big |e) a | go | re | as | ae tae [oa | | ssa | as | us = swneren 2 eps ant ue |e Gas |e ss iis |e }—iesses os ve, BS |e a wae | ae a “ oa a an ie = 3 208 2 ee | 8 2 | 8 "hone lam ae NOTE“ Coat ecm fr pcs ets ht ae nt 4atd BLOWOUT PREVENTER CONTROLS VER ar KOOMEY INC: Hw AU) SIZING THE ACCUMULATOR VOLUME FOR A 3000 PSI CONTROL SYSTEM The following information i provided to calewlate the proper accumulator volume for a safe, dependable BOP control system: f Py = Maximum pressure of accumulator when ry A Begs tae Pivs = Pave = Pave Mena aes ee Therefore: v= 29 ang = Ev s=Winimim pressure of accumulator ‘ : rinimumof200PS\ above nvogen pe with V_ = Ve ~ Vi, ‘charge or 1200 PSI is recommended) tl the formula y, (Favs) — ( Pave) PreNtogen recarge pressure (000 FSI Become = ieee Geeta) te See eee eee ei eerie Yaavewy oF Vy Be) chine conan \geVolume ofniagenst minimum presse peo votme of nrogn and has 5 1200p or ) Vaal Volie of veut nding ‘salaty tector, 1000psi CT EXAMPLE ‘Type of Preventer Open Close cp — re, 50008 Fy ck 14181788 pe Ram —— 198, 50008 cameron u sao 5s Sind Ram 1", 500% cameron os0 (67s (Choke Ki ae Ram — 198", 5900 cameron u sess Tel Gators 3135 ase A. 50% Safety Factor with B. 100% Safety Factor with ©. Close-Open-Close with 1200 psi remaining 1200 psi remaining 1200 psi remaining (StndaraRecommandaten (Sever Hazardous rs) (Opera in Gandy Close Al Prevenirs 25a |Coce At Provorters 35e | cose a reventen sat 0 Saliy Factor 1790 | too Setey Facer 3504 | open Al Peveies 1.36 Cte A Preventes su TOTAL Galons (Vy £576 |ToTALGelons va) 7166 | TOTAL Gatons(va) 106.04 Bop’ ta Boy's La ovis Law: Saal oes eee ee y= 7 Rebar oops Va= (fobs = 1000p ease 100065 ( ‘seoops: ~ socopar ) {200psi 3000p (se00ps 3000p) = 5576 4 ee 1090+ 20 i = Vy = 5076 x2 Gon He We = a0 x2 Ys 17520 1-4 gon i ieee eto Ys = 2050091211 gon Quick calculation—multiply gallons to close all preventers by 3. 95.84 x 3 = 107.52 10 Quick calculation—multiply gallons to close all preventers by 4, 35.84. x 4 accumulators Quick caleulation—multiply total | gallons to close-open-close by 2. | 103.04 x 2 = 206.08 43.36 4416 BLOWOUT PREVENTER CONTROLS KOOMEY INC, STANDARD 3,000 PSI WORKING PRESSURE ACCUMULATOR MODULES ‘This accumulator module Is shown complete with pump ‘The Accumulator Module is a 3,000 psi working pressure assem- bly that contains the stored hy- draulic fluid used to operate the various rams and valves on the BOP stack. Features of the accu- mulator module are: °11 Gallon Separator Accumula- tors. The separator type accumula tor shell has no welds, seams or joints ‘This bottle is ASME coded and can be repaired in the field by ig personnel without destroying ‘modules, control manifold and junction box. its ASME stamp of approval (USCG, DNV. TUY and Lloyds of London approval upon request). ‘The 11 gallon accumulator has.a 10 gallon actual uid and nitrogen capacity Mounting Racks. The standard accumulator module has an accu- mulator mounting rack designed to accommodate the proper number of bottles Welded Manifolds. A 4” schedule 160, welded accumulator manifold 8%, 10, 1 015 gallon accumulators re avaliable depending on height imitations. is provided complete with isolation valves an each bank Baffled Reservoirs. The fluid res- ervoir on each module is complete with baffles, 4” inspection posts and drains. Each reservoir is sized to hold two times the usable Muid capacity of the accumulators. Oilfield Skid. The complete mod- ule is mounted on a heavy duty oil field base skid The module is sandblasted, painted witha primer, and covered with an epoxy coat. 4417 STANDARD BLADDER TYPE ACCUMULATOR KOOMEY INC. Gas charging valve molded into the bladder to reduce chance of precharge loss. ~—— 2 piece vaive stem eliminates the need to replace the complete Bladder assembly ifthe valve stem is damaged ASME Coded Vessel (USCG, DNV, TUV and Lioyds of London approval upon request) Positive gas and fluid separation, Seamless, homogeneous chrome-molybdenum shell with 4-tort safety factor. No pleats or stress areas in bladder. Universal bladder resists aromatics: and operates from ~38"F (-39.4°C) 10 185°F (85°C), Insensitive to fluid contamination enceanoeannncanananneansnitl onhiied Spring compresses easily to minimize wear when bladder Mf contacts poppet, Port assembly cannot be > disassembled under precharge pressure, Doesnotdependon small—_ vent holes which can become plugged. ‘Automatic shut-down at minimum (precharge) prosaure without loso of precharge. — Built-in safety relief. 2" flow ports, 4418 a ACCUMULATOR UNITS “a IEE RO) KOOMEY ING. ll a STANDARD TYPE ’80 ACCUMULATOR CONTROL SYSTEMS ‘Type’80 3,000psiworking pressure cumulator module above also in- module and UP2RBSAO control control system complete with air cludes MODEL UET-20 electric manilold. remote control features. The ac- pump module, U7A26 air pump Type “80 Accumulitor unit above includes electrohydraulic ve- noid valves, pressure switches, equipped for operation in cold cli- mote control features consisting of —_twansducers and hydiaulic operated mates, The accumulator module explosion-proof junction box, sole- cylinders. ry 4419 y W : . ‘a ) ACCUMULATOR UNITS . iil YI KUNE INC. SPECIAL TYPE ’80 ACCUMULATOR CONTROL SYSTEMS CUSTOMIZED ACCUMULATOR UNIT. Optional Features on the above ac- flame sprayed fluid reservoir with fol module. (The accumulators ‘cumulator system include 34- top clean out man way and fluid level canbe USCG, DNV, TUV or Lloyds, loading accumulators, isolation sight glass, and special liquid filled of London approved as required in valves on each accumulator, special (panel mount) gauges on the mani- —_certainareas of the world.) CUSTOMIZED 80 GALLON GUIDED FLOAT ACCUMULATOR UNIT Guided Float type acum: shaped accumulators can be (See next page for more detailed are available as part of th mounted on top of the overall unit information on 80-gallon accumu: mulator module. These spherically to meet customer specifications. lators.) Bb 4420 ee TVS NEW FIELD REPAIRABLE TYPE ’80 GUIDED FLOAT ACCUMULATOR (Patent Pending) The new "GR" 80 gallon ball ype the NEW floatand guide rod fiber material that will not fill with accumulators guaranteed to-elimi- that can be replaced in the field fluid and sink. . nate costly downtimeincurred from without destroying the accumu- When repairing a damaged GR sending damaged accumulators lator’s A.S.M.E, code of approval accumulator, there is no cutting, back to the manufacturer for repair ‘The removable floatisalso manus welding and recoding as ther e and recoding. The “GR” features factured from a buoyant with other ball type accumulators Field Repairable After removing te guide rd, the oat ‘assemblies can be removed from the top Orbotiom of the accumulator, 4421 ter Se ee NEW TYPE ’80 WEIGHTED FLOAT GUIDED FLOAT ACCUMULATOR (Patent Pending) ‘The new “GW" 80 gallon ball not sink when the ball is moved or removable guide rod that ean be ° accumulator prevents unnecessary tipped. The float assembly has a replaced in the field without destroy- maintenance costs required to weighcon one sideandaventhole ing the accumulator’s ASME repair or raise a sunken Mloat. The at the opposite side. This prevents _ code of approval © GW" accumulator features the the float from filling with Huid NEW weighted float that will and sinking. The "GW" also has the Principle of the Weighted Float {As illustrated above, when the accumula toristilted, the welghted float prevents. tse from filing with hus 4422 ACCUMULATOR UNITS. TAV IDL XO" VRE 80 KOOMEY INC. TYPE ’80 ACCUMULATOR MODULE ‘Type 80 Accumulator modules are properly sized to provide ‘safe, reliable control. The basic accumulator modulelncludes 11 {gallon separator accumulators, mounting racks, accumulator manifold, fluid reservoir and olfeld base skid, ‘Type 80 accumulator modules are avallable with 80 gallon ball type accumulators as indicated in model 080-80GS. 4423 YY (EER ow }} ACCUMULATOR UNITS OW KOOMEY ING, SPECIFICATIONS FOR ACCUMULATOR MODULES Select Any Size Accumulator Module ch This Model Number "deatification System: Example: Mode No. IHISIAcoumiletor Modula ceca a 1 Deere ners eat Aeocilnei tin {0 Wal Adu Gators 06: 5 Gan (Sepa). "2020 Gaon (ot) = Sonera inegena i) ek ee cut ee 8 — Cute atte Fat {o-10Galon(Seprete) 4040 Galo Fost) GW — Guced Poat-Wosgtad {11 Galen Gebuatoy pat Galen ot) Gh — Gude Feet. Rervane 41 Gallon Separator Ty 2 ee ed aors| 6 | 4 | i | en | we | aa | @ | ise | 7 | tw | 20 | tow coulis |S |e eis Selamat | mal veee || ise | oS a rials | Rapa ae cae ee eee eee Senet | coe ce (eee ies | Ste | emcees |e [ee Cen | eee pesee |e] oe) ea lean se) ese] ee Seal | haley | eet ea pean | fee fae aris. | salaneimomo) e | Se | mie | Jeetate, | 283 Ses B TT] eames | 12 te een ee a ee ee: ees , iene fae as es |e SS | ees vous} |? [ao fume tie Pee) et Pe ie aoe or i ee eed ee) | alesis | ea leamm. | Sem aRit 267 ee on Be] fe | 6 [eR el eee | Resa cee SSNS Te Saeed | Er 2ao-1s | 24 10 3e0 | 149500192488 2 183, Te | 198 10,634 4828 Sore | | memes (OSRIiem| tet [ees pe041S | 26 10 geo | 1438 | 192 | 498 7 183 73 198 tit 046 Sree eae (Maen a eee lene SUE ieee | 22 Ae [eee ra cen a eo He Ee ea. | ete | Saat ee (eee Seem ee | ee saMecmites |e analgesia a 2) et | Hee] a IRR a | ead S ao ew] ST ae ee co soles oak | 2h SUS) crt gee ened nee oe SEU) SS aa Se eel ee ae ee ; |< EE ee | 360-115, 6 13 480 | 1814 | 240 610 @ | 26 | 78 198 18.182 casa | Ser celBe mers | ) ELECTRIC PUMP MODULES Electric driven pump modules feature the following: Plunger Pump. The reciprocating plunger pump is a heavy duty pump capable of upetation even when stall pieces of debris get into the system. Explosion-Proof Motor. The electric ‘motor, electric pressure switch and the motor sarterare allexplosion proof for safe operaton in hazardous areas. Heavy Duty Drive, The drive system consists of heavy duty sprockets, chain and oil bath type guard. This drive ar- rangement provides safe and durable system. Mounting Arrangement. The electric driven pump modules ean be either unit mounted or skid mounted, Either monmnting arrangement is complete with suction strainer, shutoff valve, Model UET 20-8 unit mounted, electric driven, Pa eet noc triplex pump module ing fittings Model SET 20-B separate skid mounted ‘electric driven triplex pump module OV OA PUMP SPECIFICATIONS 4429 KOOMEY INC. SPECIFICATIONS FOR AIR & ELECTRIC PUMP MODULES Select Any Style Pump Package With T) Example: Model No. oer A X—Pump Package Mounting Pump Type UUnitMounted 7A —734"AirMotor S—SkidMounted 8A— a)" AirMotor ED — Clectric Duplex ET — Electric Tiplex GD — Gasol GH— Gasol line Duplex line Hydrate Pump (WELPRO) DD —Dieset Duplex Quantity & Size orHorsepower Voltage 141-401 03—SHP. Blank —air pump 22401 O5—SHP ‘A—230V-60H2-90 40401 or OF —7.hIr 4000-001 z-Oph 151-501 10—10HP C—s73\-60Hz-3n 25-2501 15—15HP. D—220V-50H2 apn 33501 2020p E—a80v.50H23ph 161-601 25—25HP 26-2601 30-—S0HP 969601 40 —40HP ‘Air Pump Modules (Big-Sixty) Model Number Identification System: Special vas | ot 32] 4 [zy 2] 30 | se urs | 2 so | 72 ea | go | ts7] i2 | 20] 32 | o7 | 95 | a9 urase_| 3 120 | 108 so_| 7 | ios| v2 | 30] a | or | 2s | 119 ‘eas | a 40 | 36 se] [ue] gg ve | 2 foo | ws | = raze | 2 eo | 72 64 | 40 | 12) a | 7 | 4 | ior | 240 | 109 Stas | 3 veo_| 108 es | 4 | 102 | 4 | sor | a | tor | 305 | 130 | Al Pump Modules (Super-Sixty) vasis | ez | ao] «@ fav] 2 | sofas | or | us | 66 uses | 2 124 7a | e [as] 2 | | 33 | or | 26 | 105 usase | 5 185 i7_| 7% | i98| 12 | 30 | 93 | or | 308 | 199 seas | 1 62 se [oa] a2] so | 7) | ior | to | 08 seas | 2 124 78 | 40 | w2) 30 | 76 | 42 | ior | 2m | 120 sens | 3 188 a7 | 40 | woe | 2 | sor | aes | tor | oo | 59 Note: Contact Koomey Ine for information on 401 Electric Pump Modules fd S71 eatin a parnp modes Unit Mounted UES | 3 En a 610 27 veposs | 5 219 | az | 22 | 2 | 2 | si | a2 f a 610 277 ueoor-s | 75 | 250 | sas | so | so | a | a | 3 | a6 0 30 ution | 70 4a | ee [sr | ms | a |e | a |e 80 400 verse | 15 e4o | 2422 | 57 | as | 27 | 68 | 35 | a0 950 431 uev203 | 20 s70 | 300 | 57 | 145 | a7 | eo | 36 | 9 | 1.000 54 verse | 2 | 140] 41s | 57 | us | 2 | 7m | a2 | 99 | 1.130 318 uersos | an | ison | sare | ma | aa | aa [aio | aa | sro | samo 836 vers | 40 | 2020 | 7646 | 66 | ize | a | ii2 | 45 | tia | i800 a7 uETso8 | 50 | 2520 | osae | ea | aa | a | a | a | ve | 1900 63) verses | 60 | so00 | iiss | 7 | ve | 4s | 1 | 47 | 9 | 2200 4012 | Skid Mounted e008 [3 Ta] 4 | ss ] se ] 2) ) o] 1 0 Be Seb058 | 5 ate | s20 | 32 | 2 | 20 | 51 | 4 | 102 650 295 seoors | 75 | 260 | 946 | 39 | 09 | om | or | a0 | 102 700 318 seTIB | 10 455 | wae | sr | 145 | ar | 62 | 40 | 122 920 418 semis | 15 640 | 2tz0 | sr | 145 | a7 | 63 | 48 | 122 990 48 sera | 20 870 | s203 | sr | 14 | 27 | sa | 48 | 122 | 1.050 arr semse [28 [ao | sis | sm | me | 2a] me | ve | 2a | ava Bai seve | 30 | 1420 | 5375 | 8 | 173 | 46 | 117 | 50 | 127 | 1400 4 sera | 40 | 2020 | 7oae | os | 173 | a | t7_| 50 | 107 836 setsoe | so | 2520 | 9509 | 68 | 17 | 46 | 117 | so | 127 | 1,940 cy sereos | 60 | 3000 | 11355 | 70 | 178 | 48 | iz | 54 | 137 | 2270 4.031 4430 HYDRAULIC CONTROL MANIFOLDS KOOMEY INC. HYDRAULIC MANIFOLD MODULES ‘The [188 |easmpeans |oaee | vet 0 313 UvZRBAEPR Exons ra | te | 2 | me | | 725 220 UN2ABSEPR EXSGrE | | 25 [et |e |e a0 58 UMeRBEEPR Exeane 120] 905) 25 | et |e | et oy 384 UN2ABTEPR Bors ro | 305 | 25 | ot | x | 6 0 00 UMPRBEEPR EXOGRB vos | er | os | mw | im | mM 65 23a. “MI” Style — Special Unit Mounted Manifolds With Remte Air and Eleotrie Position Indicators sre ie | SE S Pe De ae 7 fewer | toe |e [IST eee | S x Wvoreaen | feaces | fe | te a] 8 | ee ae Uvewssen | aescne | fz] tap | a8 a |e | ne = Uvenomes | Aeccne | rad | Sos | as ala | @ a tvameren | fevers | tap | ae am |os | ge a benooner | Arsene | tes) or eee ee a 4435 LS SON" LYE fA Nil \) MANIFOLD SPECIFICATIONS A © Ny SPECIFICATIONS FOR HYDRAULIC CONTROL MANIFOLDS KOOMEY INC. “p” STYLE—UNIT MOUNTED MANIFOLDS With No lamote Features [ee ERE eae a 77 = Gea0ena Nopemae | 50 | 76 a | | ot iis % | Upre NoFemis | 50 | 78 ef me | a 20 a UPFOONE NoRemes | 72 | 183 oe | a] et a “| uewsoin | Nonemoe | 72 | tea a | & | 6 0 i Urzraanin | Nopemote | 72. | a oe | a4 | es a Ya Upenasia | NoRomoe | 72 | des So fod | et 60 209 Upznsenes | Noam | 120 | as & | & | & 0 ite Ussaemun | NoAamae | 120. | as. | a |e 2 2 Urereann | NoRemoe | 168 | 427 || et e6 29 Win Remote Air and Rendack Features TRG | AGRON] 72 | 16 ] = | ) = Le 7 im Ueenboan | socnacrascune | 72 | iss | 2s | oe | a | & a 26 Ureneaan | Menaarascune | 72 | ts | 2 | on | oo | ot 5 28 UPERBSAR | ASGRBorASGMRG | Tz | 103 | 2 | 6 | 24 | Gt 25 2s | Urencean | AccnBerascuae | v0 | So | 3 | ge | aa | ot os 203 Ureneran_| Acne orarcure | 120 | 30s | 3s | ge | 24 | 6s oes 23 Uraneoan | Agon or ARGUE | 68 oj aan oa | Gel eaennienen a8 ss With Remote Air Features TRO AMONG | we] ] = | @ | sm = 7 Upoena | Azamorazs | 3 | 7 | a | eo | de | at 205 % Ueneeno | Aaaawerazs | 3 | 78 | a | oo | a | et 28 ta UPR | ADAMOASG | 72 | 10 | 2 | 6: | 2 | ot as us Ussraae | ae nouporaace | te | wm | os | a | a | st Be i Urenosns | sas aaweoraacs | 72 | te | 35 |e | 2a | ot a5 216 UUparaeag | ASB Raw or ASG | =72)) tas feae foes | ann leet 58 21 Upenaens | Asp AewBorascs | 120 | aos | a | & | & | or ees oes Upsnaras | areamBorares | 120 | 30 | 28 | oe | 24 | es = | With Remote lotro Hydveule Features TERRES | OEE |e | me] es] | em eo a Uparssens | Exacporewsen | 7 | ios | 2 | oe | oe | s | stas 65 Upzapsene | Brsoperewses | 72 | i | 25 | be | me | ot | ano so Upenesens | Exscnorewecs | 120 | 0°] 2s | es | 2 | et | tts 50 Upanssens | Exes ewees | 168 | tor | 25 | Ga | 3a |g | tae Sa UUpanBsen SXOGRS 72] j28 | bt wake let a ai UpeRBseH Ercan | jes | 2 | se | a | ot | ams 385 Upaapseun Exsers | ws | bs |e |e | | atte one UbaaBaeHs exeoRs | 320} a0 | 25+} 6s | 28 | et |ttas 50 Upaapeun eens | 20 | as | a | es | om | ot | tim | ee UpeRageHA ewcns | s3_| wr | os | ex | as | ox _| sats 552 ‘With Remows Elesro Peumate Features URAREPS | GOGewewoDs | 72 | wo] = ] ] = | a eo i Urenesers | Exaceoremsas | Ye | im | as | se | me | oF 8 2 Uronesera | Exscsorensca | 7 | ie | 2s | fa | oe | ot 50 68 Uronpsere | Exsce or eNeG | 120 | a5 | 25 | 6s | 2 | ot mS) abe Upenerera | Exrosorewsca | 120 | as | 2 | e | m | 6 60 00 Urenooere | Exocoetweco | to | ter | os | ce | a | oF ce fon UranePn ea0R8 | steam fase) net |ocee foot 0 3) UpaeserA Buchs m| w]e | |e | & 725 2 UpeRBSEPR excre | 2 | wa | a | es | a | ot ato 368 UrZRBSePR fxecrs) 0} sos | 2s ee || 25 ae UreRTERR exons | 12 | as | a | ce | a | ot 630 to UeeneaE PR execna | tea | wr | a | ox | a | | oes 8 “P* Style — Special Unit Mounted Manifolds With Femote Air and Electric Posiion Indeators TPRGRAERL ECA |e a a a 25 ‘UPORBSAER AESGRS @ | 16 84 6 205 258 Heonaaer ‘AF4GAB % | ve fa Be oe ae UP2RBSAER AESGHE 72 | 188 a 6 | (ase UPeRBGAER ‘AESGRB 1 | 205 64 8 a UPERBTAER AETGAB 120_| 05 6a | ot 875 207 UP2RBBAER ‘AESGRE 169) aes fas foot popr peers mmraaa: nas

You might also like