Professional Documents
Culture Documents
Design Proof Test
Design Proof Test
afafalnlalalufofelelelolsfelele| « [ole [e[e[x sooo wopeayyie, waawa1aas xine anor Saymowaueyy, amnqgHos + PrT“op amnssarg YBIH avsuoay : oureN OPUS, NOLLIGS 0007 dX + AGO aTAvoITddV 7791 SLIND ‘ ONS TOM-NIHS 9 PYOWNIHS : AWN LOalOwd GLT"09 NOLLONULSNOO ¥ SAPALSNGNI AAVAH NVSOOd : LNAITO eee ATAGAHOS LSAL dO0Ud & ONTADLOVANNVIA © @)18UMQ - MO sxze}4 UBs00 - SQ led SSOUIINA — MA lod PIOH = H eesuosy ~ Sy 3y Nodsy-y : puebe7 odey 188, ‘03 S661 ~ 46-dS SSW (03 8661 - 6°949 ISNW/ANSY einssaig ~ se, 181g, odey 3°0°N TA / \‘038 3NSY yodey qwewyees 12 Gay 466) ueno1y, ‘a3 96, 1038 aNsy| (03 0002 30 1434 juewyeed, 189 SNIMVEC 1004S Suumoeinuen, yodey 80, jeowEuoeW ‘dav 4661. yonow41 “G3 96, 8-90LVS AWS (C3 0002 8-901 JW O14» 3801 jeoUeYON M0 HIN ‘Cav £661 yonow) “03 $8, 3NSY ‘03 0002 143 rene, - Uuojisoduog (eo]weUD — -MOJAGL BIEDIIUED IW — Suiseyoing / reusrew Suneoey ‘MO Sow sa LN3N3ATOANI VIBBLILO SONVLd300¥ ANIOd ® GOHLW NOLLO3dSNI BOVIS NOLLOdSNI ON 9002 “91 “NOP ava ONILUIS L3TUNO GZOHO3NISE wal ° ON ASH LO-Lg-dLi-sy ON aut (G11 "00 SuNSsaud HOIH 3YSNOI) NV1d ISSL 8 NOILOSdSNI Ze 1 sun ‘OUOSION.-UIUS ® HOY-US 1037OUd oNno™mPROJECT DESIGNATION SHEET *06/10/13} First issued CH.Kin Date Appro.date/ref Nodi fications Observations Approved by (ZY) KOREA HYDRO & NUCLEAR POWER CO.,LTD PRA voosan HEAVY INDUSTRIES & CONSTRUCTION CO.,LTD | P202A-DR-AO1-02 Quality Class Q Seismic Category l 0 @ sat a2 eseaaaaeasy SKNI&2 Document title BS asaenesaaa | iagee. pee ania we, Design Verification Report eRe Ae EEF we, for 2n3ay aveu, arte #04 LAs Safety Related Shop Fabricated Piping eau aaedas eo. sada, a a8 49, a9 Ai gande eae esha see 2119 Design Varifieatin asa self was ro ee OOOSAN KSHP-KS-VR-01 Heavy Industries INTERNAL IDENTIFICATION NUMBER ‘& Construction This document is the property of DOOSAN lt must not be used, reproduced or disclosed without the prior written permission of DOOSAN (91-¥|7|-T01) () FUSSSI ‘A4 (210x297Mit)PRE KSHP Design Verification Report on |P°"O| KS Ot [77 Integrally Reinforced Forged Outlets |rev.no| rev. 0 f TITLE Design Verification Report on Integrally Reinforced Forged Outlets * CUSTOMER : KHNP/DOOSAN * ITEM NAME : FORGED OUTLETS DOOSAN Heavy Ind. BLR MFG. ENG. DEP’T CIAPPROVED AS NOTED CORESUBMT AFTER REVISED py:_ 4.2 (ee DATE t_aeeé 10.70. | 9 LA rhe 7 a= | Sy 21 cok Sage. ap orl ann vie cavuree fRev,No DATE ae _ DATE Prepared by QC ENG Reviewed by QC Inspector Avproved by QA MGROo Design Verification Report on KSHP Integrally Reinforced Forged Outlets DOC. NO REV. NO KS-VR- 01 fy REV. 0 TITLE Design Verification Report on Integrally Reinforced Forged Outlets * CUSTOMER : KHNP/DOOSAN * ITEM NAME : FORGED OUT! 7 > | ET = — byt ook x Sap. 2p moe S NAME NAME NAME | RevNo| DATE DATE DATE Prepared by QC ENG “Reviewed by QC Inspector ‘Approved by QA MGR KEONSAE HIGH PRESSURE CO.,LTD aPAGE| KSHP Design Verification Report on [P| KSVR Ot | |Intearally Reinforced Forged Outlets liv xo] ev. 0 5 Contents 10 Preface 2.0 Applicable Codes and Standards 3.0 Proof Test Procedure 4.0 Spool General and Pressure Rating 5.0 Applicable Item List 6.0 Spool & Weldolet Drawing 7.0 Design Proof Test Report 8.0 Material Certification 9.0 NDE Report 10.0 Certificate of Calibration 11.0 Heat Treatment ReportKSHP Design Verification Report on [P| KVR Ol Fg” Integrally Reinforced Forged Outlets REV. No] REV. 0 1.0 Preface A run pipe having a branch connection is weakened by the opening that must be made in it. Unless the wall thickness of the branch and/or run pipe is sufficiently in excess of that required to sustain the pressure, it is necessary to provide additional material in order to meet the reinforcement requirement. Reinforcement is required when it is not provided inherently in the components of the branch connection. So, We " Keonsae High Pressure Co., Ltd.” investigates integrally reinforced fittings not covered by ASME Standards listed in table NB/NC/ND-3132-1. ‘The design of branch connection fittings may be established by mathematical analysis contained in pressure vessel or piping codes, or at the manufacturer's option, by proof testing in accordance with para 9 of ASME B 169 standard, 2.0 Applicable Codes and Standards KEPIC CODE 2000 Edition ASME B&PV CODE 1995 Edition through 1997 Addenda ASME BI69 ‘The edition in effect as of Dec. 31, 2000 MSS SP-97 ‘The edition in effect as of Dec. 31, 2000 3.0 Proof Test Procedure 3.1 Preparation of the Test 3.1.1 The representative spool DWG will be attached on this document, Component of spool : Weldolet : ASME SA105 2" x 1" S80 BW ASME SA105— 8" x 4". S/80 BW ME SA105 16" x 8" S/40 x S/80 BW Branch Pipe: ASME SA106-B 1" S/80 ASME SA106-B 4" S/80 ASME SA106-B_ 8" S/20 Run Pipe: ASME SA106-B 2” S/80 ASME SA106-B_—8"_-S/80 ASME SA106-B_ 16". S/401) PAGE KSHP Design Verification Report on [9%] KSA 01 [q Integrally Reinforced Forged Outlets |v. nol AEV. 0 8 3.2. Design proof test shall be made as set forth herein when Keonsae High Pressure 33 34 35 36 chooses proof testing to qualify the fitting design in accordance with Code and Standard ASME B169 and MSS SP-97. ‘The type of proof test is a bursting strength test. The branch connection fitting shall be welded to the run pipe. The diameter of the branch opening in the run pipe shall not be less than the inside diameter of the branch pipe. The length of run pipe on either side of the weld intersection shall be at least twice the pipe outside diameter. The branch outlet pipe extension shall have a length at least twice its diameter. Qualified Range 3.5.1 Size : One test fitting may be used to qualify similarly proportioned fittings with an NPS range from one-half to twice that for the tested fitting. 35.2 Thickness : One test fitting may be used to qualify similarly proportioned fittings with t/D ranges from one-half to three times that for the tested fitting. 353 Material Grade : The pressure retaining capacity of a geometrically identical fitting made of various grades of steel will be directly proportional to the tensile properties of the various grades. [Steel Grade SA 105 S50LF2__|SAI82 Fil CL2|SA182 F22 CL3 _TS(si) 70.000 | 70,000 70,000 75,000___| Ratio 10 10 10 1.07 Steel Grade_| A182 F304_| SAle2 Fa0dL | SAI82 F3I6 | SA182 F3IGL TS@s), 75000__| 70,000 75,000_ "70,000 Ratio 1.07 10 1.07 10 | Proof test pressure ‘Test fluid shall be water or other liquid used for hydrostatic testing, Hydrostatic pressure shall be applied to the assembly. The test is successful if the assembly withstands, without rupture, 105% of the adjusted proof test pressure defined as followDesign Verification Report on — |P°% NO] KS¥R O01 [577 KSHP | rategrally Reinforced Forged Outlets ee ee | ‘The computed proof test pressure shall be determined as follow : 28t D P = computed proof test pressure. (psi) S = specified actual tensile strength of the pipe. (psi) t = minimum wall thickness of the pipe. (inch) D = specified outside diameter of the pipe, (inch) 4.0 Spool General and Pressure Rating 4.1 Spool General All kind of outlets for ASME Sec.III piping shall be met the pressure design requirement of ASME Sec III Sub-Sec. NB/NC/ND 3643.2 and NB 36838 (a)(6), Note(6) of Fig NC/ND 3673.2(b)-1. ie Branch connection formula requirements, 42 Pressure Rating NPS sso 2/880 4/S80 8/580 16/540 op 2318 4500" 625" 16.000" | iatris sai-n | sate | sais | saea | saie-3 | tonimd oasi" os" 286 0438" oe S (act/psi) 69,040 aco | 6900 5300 | 65000 Computed Ptpsi| 16.486 11910 9047 6.734 sou | 105% of Prosi) | 17310 11,560 350 7070 “amPAGE] Doc. No] KS-VR- 01 Fg KSHP Design Verification Report on Integrally Reinforced Forged Outlets |v. yo| rev. 0 5.0 Applicable Item List No. | Description Material Size Q'ty | REMARK 1 | sockorer | saisz-Fa04 | 25"-3" x 1° 3000" SW 38 2 |socxoter | satso-raoa | 25°-4" x 15” 30008 SW 16 3 | socKoter | satso-Fa0a | 3-8" x 0.75" 3000 SW 8 - 4 | sockorer — | sats-ra0a | 4°-6" x 2° 30007 SW 2 5 |sockoter | sas2-raoa_| 6-8" x 15° 30008 SW “10 6 |sockoter | satse-raoa | 10"-18" x 15" 30008 SW 2 7 [sockoter | sars2-ra01 | 10"-26" x 0.75" 30008 SW 2 8 |sockoter | sare2-roo1_| 20r-36" x 15" 30008 SW 2 ; 9 |sockorer | sate-rais | 25"-4" x 15" 6000 SW 4 10 | WELDOLET | SA182-F22_| 6" x 15" S120/XXS BW 16 | WELDOLET _ | SA1s2-F304__| 10” x 15" S80S/KXS BW 12_| WELDOLET _ | SA182-F304__| 10” x 3" S40S BW 13 | WELDOLET | sais2-F304 | 10” x 3" S80S BW 4 8 [ 4 | 14 | wetpoer — | saise-F304 | 10” x 4" s40s BW 8 | 15 | weLpoLer | satso-Fooa | 16" x 15" S80/XXS BW 6 16 | wetvover | saiw-roa [iexasopw | 8 | 17 [wetpoer | sais2-Foo4 _| 20" x 4” STD/S#S BW 4 ; 18 | WELDOLET | SAIs2-Fa4L | 24” x 15" STD/XXS BW 4 - 19 SA1w-Fa16 | 10” x 3° S160 BW 16 : 20 | weLDoLET | SAis2-FaI6 | 16" x 2" Si60 BW 4 a1 | wetpoter | sats2-rai6 _| 16” x 3" S160 BW 8 TOTAL 194[PAGE| KSHP Design Verification Report on [°° | KSA O17 Integrally Reinforced Forged Outlets |ney yo| REV. 0 8 6.0 Spool & Weldolet Drawing * Please refer to the attached DWG. ( Attachment # 1 ) DWG NO : KO601WE(Rev.0), K0602WE(Rev.0), ‘K0603WE(Rev.0), KDSO616WO (Rev.0) 7.0 Design Proof Test Reports Spool Computer Pressure 105% Pressure | Rupture Pressure RUN | BRANCH O'let/Pipe Le os tcatfet) | Gosd | that/or (kilo) 1 2 1" | SA106/SA106-B ‘1,010 TA 11,560 813 918 2 8" 4" | SAI05/SA106-B 6,734 414 7070 497 569 3 16" 8" | SA105/SA106-B 3614 4 3,795 267 275 * Please refer to the attached report. ( Attachment # 2 ) Report No : KS-DVR-0l, KS-DVR-02, KS-DVR-03 8.0 Material Certification CERTIFICATE. No OF DESCRIPTION ITEM PIPE CAP, WELDOLET S Boss RUN BRANCH RUN BRANCH loa M1067 | a1-B00088/ | ~ Fav | RS MVR) ovenee cove | _2t-omtsjoer| | QcL-amcononst | KS-MVR-02 ex4 | KS-MVR02) 240873 9131-01 | QcL~2ooso5jo0es | QcL.~200606J0082] KS-MVR-02 Ie" x8 | KS-MVR-02] PGOs6YSB4 209873, ‘20060800471, 20060602969 KS-MVR-02 * Words in the table are informed certification No for raw material certificate and inspection certificate. * Please refer to the attached certificates. ( Attachment # 3 )PAGE| Doc. No] KS-VR- 1 Fg Design Verification Report on KSHP Integrally Reinforced Forged Outlets | nev, no| REV. 0 9.0 NDE Report * Please refer to the attached NDE reports. ( Attachment # 4 ) TEM REPORT NO REMARK ‘TEST SPOOL KNDE-BSKS-0607-M008 ax KNDE-BSKS-0607-R003 _ TEST SPOOL ~~ KNDB-BSKS-0607-M004 - atx a" KNDE-BSKS-0607-R004 TEST SPOOL KNDE-BSKS-0600-MOO1 16" x 8° 10.0 Certification of Calibration - * Please refer to the attached Certification of Calibration., ( Attachment #5 ) ITEM EQUIPMENT NO | CERTIFICATE NO PARRRATION PRESSURE EZAB47/201720 061679 WIZE CONTROL 2 Gauce =| g06006 osis77 | WIZE CONTROL "| tiermocoupte | KPM-060469 KPM Co,Ltd THERMOCOUPLE #1 KPM-060470, KPM Co.Ltd HEAT + =a ‘TREATMENT | THERMOCOUPLE #1 | KPM-o60472 KPM Co,Ltd EQUIPMENT | -ryERMOCOUPLE #1 | —KPM-060473 KPM Co,Ltd ae ce) KPM Co,Ltd 11.0 Heat Treatment Report * Please refer to the attached heat treatment report Report No : 20060907-6904 ( Attachment # 6 )KSHP DESIGN PROOF TEST REPORT _|poc. no KS-VR- 01 ATTACHMENT #1 DRAWING : KO601WE ( SPOOL 2” X 1” ) K0602WE ( SPOOL 8” X 4” ) KO603WE ( SPOOL 16” X 8" ) KDS0616WO ( WELDOLET )‘ON OMG © xo DESCRIPTION MATERIAL, Qty | sci. SIZE 1 WELDOLET ‘A105 1 $80 2°x1" Bi > 2 BRANCH PIPE $A106-B 1 $80 1"X67L 3 RUN PIPE SA106-B a $80 2"K2421, 4 END CAP ‘SA234-HPB ‘ $80 wy 5 BND CAP ‘SA234-HPB 2 $80 an 6 BOSS SA105 1 3000# 4A” npr FOR APPROVAL |0-KKn \.0.cHo1) B.c.LeE oescnmiow or Rewsion | pewin | Gc | avo | Sd ea KEONSAE HIGH PRESSURE CO., LTD =e OS] BAe Drawing #1 a9 aa en NT wen re WELDOLET 2" X 1" S80 soxe N/A. era oie | Kosowe =| = [sr QP 24-04 (REV.0) ‘A4 (297X210)“ON'OMG No DESCRIPTION MATERIAL Qty | sci. SIZE 1 WELDOLET SA105 1 $80 8X4" BW _| 2 BRANCH PIPE SA106-B 1 $30 4" X 220, ) ~~“) 3 RUN PIPE SA106-B 1 $80 8" X 877L 4 END CAP $A234-WPB 1 $30 a" 5 END CAP $A234-PB 2 $80 8" 6 BOSS SA105 1 3000# 4” NPT | 2 los FOR APPROVAL [D.KKaw }.0.cHo1] 8.0.L€€ alan naoe as[as|ealee fel | Bx | ocsoatmdn Se Zerson ori | Saco | asco | Seb |S KEONSAE HIGH PRESSURE CO., LTO oe OS] Se Drawing #2, Cae owt Qa) wot], & WELDOLET 8" X 4" S80 seus N/A emer oto KO602WE [Se QP24=04 (REV.0) ‘Aa (297X210)“ON OMG 20 ( 438.21 ) O No DESCRIPTION MATERIAL Qty | scH. SIZE 1 WELDOLET A105 1 | s4o/sgo | 16"x8" BW 2 BRANCH PIPE SA106-B 1 $80 8” X 438.21 rG RUN PIPE SA106-B 1 s40 16" X 1626L 4 END CAP SA234-4PB 1 $80 8" 5 END CAP SA234-WPB 2 sao 16" 6 BOSS SA105 1 60008 4° NPT © [eecs| FOR APPROVAL [px to.croi| ace et | Bice | ocsonrmovr aevwion Jorin | Gucd | neve | Sr a KEONSAE HIGH PRESSURE CO., LTD OAT eid Drawing #3 N/A WELDOLET 16" X 8" $40/S80 remee Ko603WeE y QP24-04 (REV.0) AA (29) 7210)DASTSOSON os a TYPE 1 TYPE 2 mms \ i ws iD hs < 50" < 1 sor NY ETAL ‘8 [2 _| i 8 8 Oo as Outlet A B c TYPE Size ‘STO xS(S80) ‘STO xS(S80) ‘STO. xS(S80) TPE 1 z 191 19.1 349 34.9 23.8 238 TPE 1 7 22.2 22.2 45 445 30.2 30.2 TYPE + 1 27.0 27.0 54.0 340 365 365) TYPE 2 7 318 318 65.1 65.1 45 45 TYPE 2 18 333 333 73.0 730) 508 50.8 TYPE 2 2 38.1 38.1 28.9 28.9 65.1 65.1 TYPE 2 25 a3 aia 103.2 | 103.2 762 76.2 TYPE 2 3 445 445 122.2 | 122.2 937 937 TPE 2 4 50.8 508 1524 | 1824 | 120.7 | 120.7 TPE 2 5 572 872 179.4 | 1794 | 1413 | 1413 TPE 2 6 60.3 78 215.0 | 2254 | 1699 | 169.9 TYPE 2 3 69.9 985 2635 | 2921 | e207 | 2207 APPLICATION CODE + MSS SP-97 - 1995 EDITION MAKER STANDARD 0 [amssia] For Approvat| sxm room] neue aa] ae Waar we [ae ae eer Rev. | DATE | DESCRIPTION OF REVISION] DRAWN | CHK’D | REV‘O | APP'D. DS Keon SAE HIGH PRESSURE CO, LTD. De) ae Shin-kori & Shin-wolsong, St | prover units 1 & 2 ane ea (oe) Oa] cw int GP et) Seer WELDOLET R= | ows.o. | KDSosiswo | “HY |S 2DASTSOSON a ams TYPE 1 TYPE 2 aren , 7 ss \ < SO og 50° ZETA “4° : |<] 8 8 as Outlet A B Cc TYPE | ‘size [seneo | 0S | senteo | 0S 5160 ws TYPE 1 7 28.6 28.6 349 349 18 64 TYPE 1 a a8 318 45 445 156 4 TYPE 1 38.1 38.1 50.8 50.8 20.6 152 TPE 2 id 445 5 61.9 619 29.4 22.8 TPE 2 ib 50.8 508) 69.9 629 34.1 279 TYPE 2 2 55.6 556 81.0 81.0 29 38.1 TYPE 2 2b 619 619 96.8 96.8 54.0 45.0 TYPE 2 3 73.0 73.0 | 1207 | 1207 65.7 585 2 [rea eat | gat | 1524] 1524] a7 | 801 TYPE 2 5 937 337 1873 | 1873 | 1095 | 103. TYPE 2 6 1068 | 1048 | 2207 | 2207 | 1319 | 1243 TYPE 2 a via | ta | 204.2 | 204.2 1781 1747 APPLICATION CODE : MSS SP-97 = 1995 EDITION MAKER STANDARD 0 [emesis] For Approval| sm wove] acued ae, aT WeaR We [sey wa per rev. | oaTe_|pescepnon oF rewsion| orawn | cHK’o | Revo |APp'O S keon SAE HIGH PRESSURE CO, LTD. @. ane SHEFF ESA WOTEONG, sae © | provecr units 182 Za Ge) Ox] cw UNIT WINCH) eroecT WELDOLET SCALE wa ee eres — | owe.no. | KDSosiewO | “oY | 5%KSHP DESIGN PROOF TEST REPORT _|poc. xo KS-VR- 01 ATTACHMENT #2 DESIGN PROOF TEST REPORTS KS-DVR-01 ( SPOOL 2” X 1” ) KS-DVR-02 ( SPOOL 8” X 4” ) KS-DVR-03 ( SPOOL 16” X 8” )Reva] DESIGN PROOF TEST REPORT [20%] KSOVR Of ["Y KSHP gon ms +———| , xl pare } 2006. 9. 21 NO Item Soh, Mat! size | Lenght [Heat No] s | S(act.) [o wot seo | satos | 2x1"| - | 247020| 70,000 | 74,980 F@ | Branch Pipe | sao | sato6-B ‘| 67 | 149756 | 60,000 | 69,040 @ | Run seo | satos-3 | 2° | 2421 | sogzaa | 60,000 | 68,460 @| Endcap | sao |sazsewre| 1° = | 181926 | 60,000 | 83,200 @| Endcap | seo |sazae-wea| 2 - | xe2a28 | 60,000 | 73,200 0 [s Pressure Gauge 1D. No. | 1806206 (max. 95,000 Psi : 2,460 kat/at) @® | Computed Test Pressure (P) 11,010 psi 774 katlat © | 105% Pressure of Pipsi) 11,560 psi 818 kot/ae @ | Max. Pressure applied at rupture | 13,050 psi 918 kat/ar ® Rupture Location (if ary) 7 Near HAZ ® Test Result ; ‘Accent : E |p =2st/D X | t = minimum wall thickness of the pipe. (inch) f | $= Actual Tensile Strength(psi) Spool Drawing Related Photograph ler Low ? Le WY Hanog or Prepared By Reviewed By Approved By "Witnessed By CustomerV9 xsyp | DESIGN PROOF TEST REPORT [7°10] ISO @ |" ") ax 4 pare | 2006. 9. 21 | ° No| tem | sch | mati | size | Lenght |HeatNo] S| Stact. o WoL sao | saios |a*x47| - | 247020| 70,000 | 74,080 @ | Branch Pipe | sao | saioe-a | 4 | 2291 | 14905 | 60,000 | 69,000 @| Fun Pive | seo | saios-8 | #8 | 8771 | 67218 | 60,000 | 66,300 @| Endcap | seo |saza4wes| 4" | vae06e | 60,000 | 73,700 @| Endcap | seo |sazse-wea] @ | - | x28670| 60,000 | 74,600 ® Pressure Gauge ID. No. 1806206 (max. 35,000 Psi : 2,460 kat/at) @ | Computed Test Pressure (P) 6,734 psi 474 katlor © | 10596 Pressure of Pips) 7,070 psi 497 Kotlar | ® | Max. Pressure applied at rupture 8,090 psi 869 kat/at ® Rupture Location (it any) ; Near HAZ. ® "Test Result - Accept £ |p =2st/0 | M | t= minimum wall thickness of the pipe. (inch) | f | $= Actual Tensile Strength(psi) Spool Drawing : Related Photograph ST ow | ? 04 Hanger “Prepared By | Reviewed By Approved By Witnessed By CustomerEVI KsHp | DESIGN PROOF TEST REPORT [°°] SOW 0 16" x 8" pane | 2006. 9. 21 | ° [No] tem Sch. | Matt | Sie | Lenght [Heat No] Ss | Stact.) © wot |sao/seo| satos |16"xe| - | 60741 | 70,000 | 76,100 @ | Branch Pive | seo | satoo-8 | @* | 438.2L| 67218 | 60,000 | 66,300 ®| Pun Pie | sao | saros-8 | 16° |1626.0.|1-54161| 60,000 | 68,000 @® "End Cap $80 | SA234-WPB. 8° - ADOS2 60,000 | 71,800 ® “End Cap S40 | SA234—-WPB 16" = L654 60,000 | 72,500 OTe) Pressure Gauge 1b. No 1806206 (max. 35,000 Psi : 2,460 kgf/at) © | Computed Test Pressure (P) 3,614 psi 254 katlar @ | 105% Pressure of P(psi) "8,795 psi 261 Kotlar ® Max. Pressure applied at rupture 3,911 psi 25 katlon [@ | uptare Location Gt any) Near HAZ | : ® Test Result - Accept a £ |p =a2st/0 X | t = minimum wall thickness of the pipe. (inch) & | $= Actual Tensile Strength(psi) Spool Drawing Related Photograph GO Manager Prepared By Reviewed By _ Approved By “Witnessed By Customer