You are on page 1of 4
OXYCARE__.. OXYCAREPLUS : oxygen concentrators Ce 1984" { ww.heltman.com.te = HELTMAN OXYCARE OXYCAREPLUS About Oxy: ‘Oxygen is colorless, odorless, and tasteless as well as a gas art highly reactive nonmetal. The quid and sof forms ‘of oxygen are a pale blue color and are strongly paramag- netic. It is a component of hundreds of thousands of or- Ganic compounds and combines with most elements, Its essential for respiration of all plants, animals and for most types of combustion. The Atmospheric Air The ambient air that we breathe contains approximately 78% Nitrogen, 21 % Oxygen, 0.9% Argon and the rest other trace gases. The most economic and easy method for separating the Oxygen gas from the ambient atmospheric air mixture fusing the PSA Technology What is PSA Technolog} Pressure Swing Adsorption (PSA) is a ‘eon Used to separate some gas species from a mixture of gases under pressure according to the species’ molecular characteris- tics and affinity for an adsorbent material. It operates at near-ambient temperatures and so differs from cryogenic distilation techniques of gas separation. Special adsorptive materials are used as a molecular sieve, preferentially ad sorbing the target gas species at high pressure. The process then swings to low pressure for desorbing the adsorbent material Using two adsorbent vessels allows near-continuous pro- duction of the target gas. It also permits so-called pres- sure equalization, where the gas leaving the vessel being de-pressured is used to partially pressurize the second ves- sel, This results in significant energy saving, It is a common industrial practice where also another application area is the Oxygen Concentrators. The oxygen generator consists of compressor, two large sieve beds, a valve assembly, air filters, flowmeter, main pressure regulator, and the product, tank. As a rough figure, the system works out like at this diagram. In detail, compressed air is taken from the atmosphere, fi tered intensively and sent into a bed containing a molecu- lar sieve of Zeolite. As the air is forced through the Zeolite, the nitrogen attaches to it and the oxygen passes through tobe given from the outlet while passing from the flowme- tet for adjustment of the desired flow rate. The bed will be eventually loaded up with nitrogen, so it must be flushed periodically which is called “exhaust”. Two beds are cycled to load and unload the Zeolite for producing a continuous stream of Oxygen gas. Oxycare™ and OxycarePLUS™ The technology of both of the nye is completely new and innovative in the world. It is the combination of the lower power consumption, lower noise level and lower ‘weight with the fundamental purity or high purity oxygen. “OXYCARE" supplies oxygen with fundamental purity. OX- ‘YCARE PLUS” supplies oxygen with high purity em, on UL HELTMAN Oxygen Concentration Status Indicator (OCS!) ‘With the optional multi functional oxygen Sensor integra- tion, itis possible to measure and simultaneously monitor the amount of the oxygen within As being simultaneous with the ox- ygen flow, this special sensor meas- tres and shows the oxygen purity, which is one of the most vital information for the patient, at the LCD. The Unique Indications There is a 128x64 pixels back lighted graphic Liquid Crystal Display (LCD) on the device which is displaying the total operation hour(s), information and malfunctions of the device audibly and visually. When turned ON initially, it starts the "SELF CHECK" every time and then starts to operate incase everything is normal, Meanwhile an acoustic alarm can be heard OXYCARE| OXYCAREPLUS On the LCD, the following information can be seen; INFORMATIONS ‘+ The Bubble Humidifier Replacement Reminder At Every 1000 Hours Of Use ‘+ The Nasal Cannula Replacement Reminder At Every 250 Hours Of Use ‘The HEPA Filter Replacement Reminder At Every 500 Hours Of Use + The Maintenance Of The Air Inlet Filters Reminder At Every 25 Hours Of Use ALARMS + High Pressure + Low Pressure + Over Heating Also the device has the audio alarms for + Electrical Shortage (with a 9 V Battery inside) ‘When OxylivePLUS™ model has a decrease at the Oxygen level which goes under 80%, then it can be seen the “Low Oxygen" information note on the screen while the whole screen is flashing. But the system keeps on running and still supplying to the user as much Oxygen as it can, AF The Alarm Memory Facility This device has the ability of keeping the records of last 4 alarms in its memory with the exact time of alarms given, thus the technical service authorized personnel could have a better idea about the device and the failure, No other homecare Oxygen Concentrator has this option as “defa- ult”. A key lock exits for seeing this information screen on the LCD. When a new alarm occurs, the oldest one will be erased from the memory. The Filter System ‘There is the Gross Particle Filter Rectangular, Fine Particle Filter-Round, Felt Filter-Round, Pall Filter at the air intake and a Bacteria Filter before the outlet. The filters which should be replaced or periodically cleaned are placed "easy to teach” for supporting “user friendly” environment. No screw to deal with or no need to disassemble any cover. Also there is another filter at the back side of the device ‘which filters the cooling air from Gross particles while be- ing taken from outside. And More... The design of the device is protective for keeping the Bubb- le Humidifier against any possible impacts or crushes that ight cause breaking the bottle. There are 4 castors (2 of them are lockable for maintaining the stability) and unbre- akable builtin handle gives the user maximum mobility in every direction easily. OXYCARE| OXYCAREPLUS TECHNICAL FEATURES odes ORYEARE™ ORYCARE™ PLUS Electrical Requirement 220 V / 50 Hz (Optionally 60 Hz) oer ose Mox 40W/20 Fess 250A Outlet Pressure 8.50 psi (= 0.57 Atm = 586 mbar) Air Flow: 0-5 Limin (Increments of 0.5 LPM) 0-5 Umin (Increments of 0.5 LPM) Oxygen Concentration Fundamental Purity High Purity Oxygen Purity @ 1 Lick %95 (4/- %2) LPM. LPM Oxygen Purity @ 2 Lick, %93 (4/- %2) 2PM. 2LPM Oiygen Party @ 3 Usk 692 96D} LPM BPM Oiygen Party @ 4 Usk ST 96D} PA ap Orpen Puri @ Sk 3690 oF 962} SL LPM Nowe Level

You might also like