1 Safety statements
1.1 Basic requirements
 Read this document carefully before installing and using the ISCOM
HT803G-WS2. Otherwise, severe bodily injury or device damage may be
caused. Raisecom Technology Co., Ltd. (hereinafter referred to as Raisecom)
will not be liable for any losses caused by violation of any safety issues.
 The ISCOM HT803G-WS2 is an integrated device with precision
components. To prevent device damage caused by severe shock, avoid
collision and vibration. You shall not disassemble or repair the ISCOM
HT803G-WS2 by yourself. If necessary, follow Raisecom engineers'
instructions.

1.2 Environmental requirements


 Place the device in an environment with good ventilation and no direct
exposure to strong light.
 Keep the device clean and away from dust, water, and moist areas.
 Do not place any object on the device to avoid damage due to overheating or
compressional deformation.
 When installing the device, keep it away from heat or fire sources, such as
the electric heater and candle.
 When installing the device, keep it away from electric appliances with
strong magnetic field or electric fields, such as the microwave oven and
refrigerator.

1.3 Electric safety


 Use the original power adapter included in the package or replacement
provided by Raisecom. Using other power adapters may cause device
damage or other problems.
 The voltage and current of the power supply must meet requirements on
input voltage and current. Overcurrent protection is required.
 Keep the power plug clean and dry to avoid electric shock or other risks.
2
 Before pulling out a cable from the device, stop using the device and power
it off.
 If you do not use the device for a long time, power it off and pull out the
power plug.
 Do not let water or other liquid flow into it. If this happens, power off the
device immediately, pull out all cables from the device, and contact
Raisecom technical support personnel.

1.4 Laser safety


 Personnel operating the fiber must be trained on laser safety.
 Do not bend the fiber much to make its diameter smaller than 7.5 cm or 3
inches. Otherwise, the fiber may be damaged or optical signals may be
blocked.
 Do not stare into the optical interface or end face of the fiber to avoid eye
injury.

1.5 Other precautions


 If any abnormality occurs, such as smoking, abnormal sound, and peculiar
smell, stop using the device immediately, power it off, pull out all cables
from it, and contact Raisecom technical support personnel.
 Do not let any object (such as metal) enter the device through heat
dissipation holes.
 Do not scrape or abrase the device shell. Otherwise, falling coating may
cause device malfunction (even short circuit if entering the device) or
human allergy.
 Do not let children play with the device or components to avoid dangers
caused by swallowing, and so on.

3
2 Legal notice
The copyright of this document is owned by Raisecom. No part of this publication
may be excerpted, reproduced, translated or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without written
consent from Raisecom Technology Co., Ltd.
 When a user finishes installing the device and starts using it, it implies that
the user has completely understood safety statements of this device. The
user is liable for any losses or damage caused by violation of safety
statements.
 The information in this document is subject to change without notice. Every
effort has been made in the preparation of this document to ensure accuracy
of the contents, but all statements, information, and recommendations in this
document do not constitute the warranty of any kind, express or implied.
 Raisecom is not liable for any losses or damage caused by natural disasters
beyond Raisecom's responsibilities, such as earthquake and flood.

3 Device specifications
3.1 Technical specifications
Table 3-1 lists technical specifications of the ISCOM HT803G-WS2.

Table 3-1 Technical specifications of the ISCOM HT803G-WS2


Parameter Description
Dimensions 184 mm (Length) × 129 mm (Width) ×38
mm (Height)
Weight < 0.5 kg
Maximum power consumption < 18 W
Input of the power adapter 100–240 VAC (50/60 Hz)
Output of the power adapter 12 VDC, 1.5 A
Operating temperature 0–50°C (altitude: 0–1800 m)
Operating humidity (RH) 10%–95% (non-condensing)

4
Parameter Description
Wireless type 2.4G&5G dual-frequency Wi-Fi

Table 3-2 lists technical specifications of the PON interface on the ISCOM
HT803G-WS2.

Table 3-2 Technical specifications of the PON interface


Parameter PON signals
Interface type SC/APC
Typical optical wavelength 1310 nm/1490 nm
Tx optical power 0.5–5 dBm
Rx optical power -28 to -8 dBm

3.2 Packing list


Table 3-3 lists packing list of the ISCOM HT803G-WS2.

Table 3-3 Packing list


Device/Component Quantity
ISCOM HT803G-WS2 1
Power adapter 1
Ethernet cable 1
Telephone line 1
User manual 1

If any item mentioned above is missing, contact the SP.

5
4 LEDs

6
5 Connection and usage
5.1 Interfaces and buttons

The figure shown above is diagrammatic only. The actual


appearance is subject to the device provided by the SP.

7
-
---------------------------------------------------------

Warranty Record

Record of Damage and


Signature
Repair Signature of
Date of Repair
Damage Repair Customer
man
Reason Measure

Address: East-11, Raisecom Building, 10 Xi Bei Wang East Road, Haidian District, Beijing, China
Post Code: 100094
Tel: +86-10-82883305
www.raisecom.com

8 Raisecom Technology Co., Ltd.


-------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----------------------------------------------
-------- -----------------------------------------------
Product Warranty Sheet
Customer Name:_ _ _ _ _ _ _ _ _ _ _ Phone Number:_ _ _ _ _ _ _ _ _ _ _ _ _ _

Address:_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Thank you very much for purchasing Raisecom products. For the sake of being
responsible for you, and guaranteeing premium after-sale service, please carefully
read and fill up this sheet.

Warranty Policy:

1. Our products carry a type warranty period of 1 year after warranty sheet has
been provided to you. In this period, any problem that caused by the product
itself and confirmed by our technical engineers will be fixed free of charge.

2. Please present the warranty sheet and the receipt when requesting services.

3. The following circumstances are not included in the warranty:


 Products are misused, or used in abnormal situations.
 Damages that are attributable to improper installation, disassembly or
repairing by unauthorized parties.
 Product serial number and the number on receipt are amended without
permission.
 Damages caused by natural disasters or human behaviors.
 Product has been exceeded warranty period.
 Damages that are attributable to use the components that are not Raisecom's.
 Damages caused by accident or man factor, include: Computer Viruses,
Improper Carry, Extrusion, Kotow, Scuffing, Bump, High-temperature,
Inputting improper voltage, Cauterization, etc.
 Damages caused by irresistible power (for instance: Earthquake, Flood and
etc). Other damages which are not attributable to product design, technology,
product, and quality.

4. We are providing lifetime repairing services to our products. Repairing


outside the warranty period will be charged of the cost.

9
5.2 Installation modes
The ISCOM HT803G-WS2 can be installed on a stable workbench or a wall.

Installing the ISCOM HT803G-WS2 on the workbench is


informal because unpredictable events (such as collision or object
falling) may prevent the ISCOM HT803G-WS2 from working
properly or even damage it. We recommend installing it on a wall.

Install the ISCOM HT803G-WS2 on a wall as below:

Step 1 Choose a proper height of installation position so that you can easily
observe LEDs and connect the power supply.

Step 2 Knock two cement nails, with spacing of 155 mm (distance between two
wall-mount holes), into the wall. The diameter of a cement nail should
be smaller than that of the wall-mount hole (8 mm).

Step 3 Align wall-mount holes with knocked cement nails, and hang the device
on nails. The device is hung by the nails on the wall.

Figure 5-1 Wall-mount installation

Step 4 Check by slightly shaking the device whether it is firmly installed on the
wall.

10 Raisecom Technology Co., Ltd.


5.3 Connecting power supply
The ISCOM HT803G-WS2 adopts an external power adapter to supply power:
 Input of the power adapter: 100–240 VAC (50/60 Hz)
 Output of the power adapter: 12 VDC, 1.5 A

Connect the power supply as below:

Step 1 Insert the 12 VDC power adapter plug into the power interface on the
ISCOM HT803G-WS2.

Step 2 Insert the 100–240 VAC power adapter plug into the AC power socket.

Use the power adapter included in the package or the replacement


part provided by Raisecom. Other power adapters may cause
device damage or other problems.

5.4 Powering on device


Step 1 After the ISCOM HT803G-WS2 is properly installed, insert the power
adapter plugs and connect them to the device and socket respectively.

Step 2 Press the ON/OFF button. If the Power LED is green, it indicates that
the ISCOM HT803G-WS2 is powered on properly.

Step 3 After Power-On Self-Test (POST) and initialization, the ISCOM


HT803G-WS2 enters working status.

5.5 Accessing device


Step 1 Connect the ISCOM HT803G-WS2 with the power supply and PC
properly. For details, see section 5.1 Interfaces and buttons.

Step 2 Press the ON/OFF button. If the Power LED is green, it indicates that
the ISCOM HT803G-WS2 is powered on properly.

Step 3 Configure the PC to automatically obtain the IP address.

11
Step 4 Open a browser. Enter the IP address (on the label) for accessing the
ISCOM HT803G-WS2 at the LAN side, and press Enter. The Web
login interface appears.

Step 5 Enter the correct user name and password (on the label) to access the
ISCOM HT803G-WS2.

12 Raisecom Technology Co., Ltd.


6 FAQ
Why is POWER LED off?
 Please check whether the ON/OFF button is pressed.
 Please check whether the power adapter is the standard one equipped for the
ISCOM HT803G-WS2.
 Please ensure that the power adapter and the power interface/power outlet
are connected firmly. Alternatively, try to remove the power adapter plug,
and then re-insert it. If necessary, please use the voltmeter to check whether
the output voltage of the power adapter is 12 V.

Why is PON LED off?


 Please check whether the fiber works properly.
 Please check whether the fiber is connected properly.
 Please check whether the fiber connector is clean.
 Please check whether optical attenuation is normal.
 Please check whether the SN or MAC address matches with the OLT.

Why is LOS LED blinking?


 Please check whether the fiber connector is properly inserted into the correct
interface.
 Please check whether the fiber connector is clean.

Why is LAN LED off?


 Please check whether the Ethernet cable meets the standard and whether it is
properly connected.
 Please check whether the Network Interface Card (NIC) LED is lighted up.

13
 Please check whether the NIC is properly working. In a Windows operating
system (taking Windows XP for example), right-click the My Computer
icon, and then choose Manage. Click Device Manager on the left tree
topology to check whether a device with "?" or "!" symbol is displayed
under the Network adapters option. If yes, uninstall the device driver and re-
install the driver. Or you can insert the NIC into another slot. If the problem
is not solved, replace the NIC.

14 Raisecom Technology Co., Ltd.


RoHS Compliance Declarations
The raw materials of the product mentioned above are compliant with RoHS 2.0 regulations,
also known as Directive 2011/65/EU of the European Parliament and of the Council of 1
June 2011 on the restriction of the use of certain hazardous substances in electrical and
electronic equipment.

RoHS specifies maximum levels for cadmium (Cd), mercury (Hg), Hexavalent Chromium
(Cr VI), Polybrominated Biphenyls (PBBs), and Polybrominated Diphenyl Ethers (PBDEs)
on each homogeneous material in the product.

 Cadmium (Cd) ≤ 100 ppm


 Mercury (Hg) ≤ 1000 ppm
 Hexavalent Chromium (Cr VI) ≤ 1000 ppm
 Polybrominated Diphenyl Ethers (PBDEs) ≤ 1000 ppm
 Polybrominated Biphenyls (PBBs) ≤ 1000 ppm

According to Exemption No. 7 from Directive 2011/65/EU for lead in telecommunications


equipment, applications exempted from the prohibition are shown below.

 Lead in termination coatings of electrical and electronic components


 Lead in solders on printed circuit boards
 Lead in solders
The product is compliant with RoHS Directive 2011/65/EU and subsequent revised RoHS
directives (including Exemptions), as required below.
 Lead in high melting temperature type solders (i.e. lead-based alloys containing 85%
by weight or more lead)
 Lead in solders for servers, storage and storage array systems
 Lead in solders for network infrastructure equipment for switching, signaling,
transmission as well as network management for telecommunications
 Electrical and electronic components containing lead in a glass or ceramic other than
dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic
matrix compound
The maximum permitted concentrations in non-exempt homogenous materials are specified
as below.
 Lead ≤ 1000 ppm

15
Raisecom Technology Co., Ltd. provides customers with comprehensive technical
support and services. For any assistance, please contact our local office or
company headquarters.

Website: http://www.raisecom.com

Tel: 8610-82883305

Fax: 8610-82883056

Email: export@raisecom.com

Address: Raisecom Building, No. 11, East Area, No. 10 Block, East Xibeiwang
Road, Haidian District, Beijing, P.R.China

Postal code: 100094