Sheet1

Impedance Transformer Calculator


Imp. of Imp. Of Primary /
Antenna Coaxial Secondary Primary Secondary
(Primary) (secondary) Ratio Turns Turns Total Turns

10 50 0.447 5.00 2.24 7.24


20 50 0.632 6.00 3.79 9.79
40 50 0.894 6.00 5.37 11.37
50 50 1.000 6.00 6.00 12.00
100 50 1.414 5.00 7.07 12.07
200 50 2.000 4.00 8.00 12.00
300 50 2.449 3.00 7.35 10.35
400 50 2.828 3.00 8.49 11.49
500 50 3.162 3.00 9.49 12.49
600 50 3.464 3.00 10.39 13.39
700 50 3.742 3.00 11.22 14.22
800 50 4.000 3.00 12.00 15.00
900 50 4.243 3.00 12.73 15.73

Formula- Np / Ns (Turns Ratio) = sqrt(Zp / Zs) by VK3HK

instructions: Input Antenna Impedance (primary)


Input Feed Line / Radio Impedance (secondary)
Input Number of Primary Windings

DO NOT enter anything in yellow shaded cells

Page 1