Professional Documents
Culture Documents
Fd1002s Olt User Manual Ems Part v1.1 20150603
Fd1002s Olt User Manual Ems Part v1.1 20150603
No part of this manual may be reproduced or transmitted in any form or by any means
without the prior written consent.
The information in this document may be update at any time due to product versions
upgrade or any other reasons. Unless otherwise agreed, this manual is for reference only.
All statements, information and recommendations in this manual do not constitute the
warranty of any kind, express or implied.
Please contact your suppliers to get the latest version of this document.
Revision History
END ................................................................................................................................................ 62
4 / 62
FD1002S OLT User Manual-EMS Software
1 1 Software Introduction
宽带接入
1.2 Functional Features
用心服务
EMS software has following main features:
Based on standard SNMP protocol
Support multiple client access, C/S architecture
Support integrated management all our EPON series products
Support auto topology or modify manually, and multi-layer map view
Support configuration operation on all EPON products functions
Support multiple level operation authority
Real-time and history alarm record view, search and save
Operation history record trace and save
Use independent database and support data backup and import
Support performance monitor and traffic counters statistic
Support third-party database platform
EMS software installation needs two steps, database installation and EMS software
setup. And database need to be installed before software setup.
The opened third part database software Mysql is used by EMS. The Mysql setup
programs provided in CD which is shipped with products can be directly used or you
can download it from internet. Remember 5.0 or higher version is compatible with
EMS software.
5 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Click Next to continue: 用心服务
6 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
Installation finished, choose “Configure the MySQL Server now” option to begin
database software configurations:
7 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
8 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
9 / 62
FD1002S OLT User Manual-EMS Software
用心服务
Choose “Modify Security Settings” option, and set “New root password” as
“1234”, and set it again in “Confirm” text field to confirm this security
password.
This password is used by EMS software to access MySQL database and
must be set correctly. Then click Next to continue:
10 / 62
FD1002S OLT User Manual-EMS Software
Come here, MySQL database configuration wizard finished, click Execute to startup.
EMS software can be installed when MySQL database has been successfully
installed. Run EMS set up program directly, and then following the installation
wizard to finish all the installation steps. There are no special configuration options
during the whole installation process.
After EMS has been successfully installed, there will be two program icons
11 / 62
FD1002S OLT User Manual-EMS Software
3 EMS Startup
宽带接入
3.1 MySQL Database Startup
用心服务
MySQL database must be startup before EMS software. Normally, MySQL should
has been running up when configuration wizard successfully finished. Following
method can be used to verify if MySQL database is already running up.
Right click My Computer icon, select “manage” option and then open the “service”
window to verify if the “MySQL” service status is “started”.
EMS software is C/S structure, including Server and Client two parts. Server
program must be started first, and Client program should be run up when Server
has been successfully started.
Double click EMS Server program icon to run it. There will be a Server icon
located on the program running field, typically as following:
Note: EMS Server will take several seconds, normally it will not longer than 30 seconds. If
the program running icon can’t be found there, EMS Server startup failed. In this condition,
you should check to verify if the installation requirements are satisfied and if the MySQL
database is successfully configured and started.
After EMS Server has been started, EMS Client program can be run up. Client
and Server program can run on a same computer or a different computer, just
need the network between them communication well.
12 / 62
FD1002S OLT User Manual-EMS Software
Following logging window will appear after the Client software successfully started.
.
If Server and Client software are installed on a same computer, you should just input
the correct username and password. If they run on different computer, you need set
the Server’s IP Address through the Advance configuration part. The typical
interface is as following.
宽带接入
用心服务
As above, Poll Server field is the IP Address (e.g.: “192.168.10.3”) of the computer
on which EMS Server is running. The other fields, Port and Timeout use the default
value normally. If the transmission delay between Server and Client computers is
not so good, you can change the default Timeout value to a larger one.
Note:
1) The default Poll Server IP Address value is “127.0.01", which is the Loopback Address
of the local computer. You need not change this value to other Address if the Client software
runs on the same computer with Server software.
2) The default username and password are “admin” and “1234”. You can change them
when logging in.
The main software interface will appear when successfully log in. The typically initial
window is as following:
13 / 62
FD1002S OLT User Manual-EMS Software
By now, EMS Server and Client software has been successfully start up
System Menu
Including System Configuration, MIB Browser,
Database Maintenance and User Manage, etc.
Alarm Menu
Alarm Query, Configure Trap Rule and System Log
are within this menu.
Configuration Menu
Top-tree update, device add/delete, device
configuration, map update and device upgrade
features are located in this menu.
Performance Menu
Including performance monitor and alarm threshold
configuration.
Help Menu
Change software skin, language and About information.
宽带接入
The Top-tree list contains all the added and accessed
用心服务
devices managed by EMS. Through this device list, manager
can view some visual device information, such as online or
not, alarm status and location info etc. Double click the
device icons can navigate to their management interface
Top-tree
2 window.
Device List
Topology
Use these buttons to manage device icons on the
3 Shortcut
background map.
Bar
Topology Map window is the main area of EMS. The topology
map of managed device is displayed here. For convenience
of managing, manager can move device icons to their
installation locations which are normally matched with the
background map.
Topology
By double click the device icons located on the map,
4 Map
manager can open the corresponding device management
Window
window to operate.
15 / 62
FD1002S OLT User Manual-EMS Software
用心服务
16 / 62
FD1002S OLT User Manual-EMS Software
Add “Location”
Submenu
宽带接入
Add “Location”
Shortcut Icon
用心服务
Operation steps:
i. Select the parent node for new added node;
ii. Input the name of new node;
iii. Select map for the new location node (The map should be upload
first), when select this node on top-tree, the topology area will apply
this map;
2) Location node delete
17 / 62
FD1002S OLT User Manual-EMS Software
As above figure, right click the selected location node and delete it.
用心服务
18 / 62
FD1002S OLT User Manual-EMS Software
When the above parameters are configured, click OK button to finish the
device add operation. When success, the new added device’s icon will
appear on top-tree list and topology area. Showing as following figure:
node
Note: For FD1002S OLT device, only the chassis node need to be added
manually, other part such as equipped card and accessed ONU device need not
to be added. These devices will be detected automatically.
19 / 62
FD1002S OLT User Manual-EMS Software
Note:
i. Deleted device can’t be restored and need to be added when need.
ii. All the information of the deleted device will also be removed from
EMS.
iii. None any configurations on the deleted device itself will be changed。
宽带接入
6.1 OLT Chassis Management
用心服务
Double click the OLT chassis icon to open the chassis management window. Typically as
following figure:
Front Panel PON
Out-band
Uplink Port(SFP)
Front Panel
Four uplink ports, two PON port, one console port, one out band network management
port.. Led Indicator located on the card panel graphic display the card’s real time working
status.
When EMS can’t connect with the OLT the windows will change to gray color.
Basic Information
The basic information of device type , SN, Version, Alarm Status, System Description,
Installation location and manager contact information.
Double click switch and control card icon on top-tree list or the card panel icon located on
20 / 62
FD1002S OLT User Manual-EMS Software
chassis management window to open the switch and control management window.
Typical as following figure::
宽带接入
Following management features are contained on this window::
Following sections in this part introduce the management features contained on the
switch and control card management window.
Basic Information
Include device type, serial No, software and hardware version, running status and time
information.
System Configure
Note:
1) The network parameters configured here are for the out-band interface of
FD1002S OLT device.
3) Usually, EMS will lost the connection with managed device when change
the network parameters. Manager should change the network
parameters of the managed object in EMS to the same value with the
parameters configured in the device itself to recover the connection.
Note:
宽带接入
2) EMS should use the same Community values to access the managed
device.
用心服务
Configure or Check TRAP Receiver Address
The TRAP receiver address is the destination IP Address where device alarm
information is sent. When there are alarm occurred, these alarm information will be sent
to these configured target IP Address. Usually, the TRAP receivers are those computer
servers on which EMS software is installed. Four receiver IP Address can be configured
at most.
FD1002S supports In-band and Out-band two network management interfaces. Any one
of the eight uplink port can be used as In-band management port without any special
specified.
Now, one network interface identified as “vi0” can be used as in-band network interface.
Manager can configure its network parameters on this page, such as IP Address, Subnet
22 / 62
FD1002S OLT User Manual-EMS Software
Mask, Default Gateway and Management VLAN. This network interface can also be
disabled.
Note:
23 / 62
FD1002S OLT User Manual-EMS Software
FD1002STRUNK features:
TRUNK can applied on all four uplink ports;
Support t trunk group at most;
Each TRUNK group support two physical ports(Only support port1
and port3 configured to one group, port2 and port4 TRUNK configured
to one group);
Trunk Table
This table displays all the configured Trunk groups and their port members. Trunk ID is
used to identify one Trunk group uniquely.
宽带接入
Allocate an unused Trunk ID, choose the port members for this group (only
those un-allocated ports can be chosen), then click Add button to create a new Trunk
group. The new added group and its members will be displayed in “Trunk Table”.
VLAN (Virtual Local Area Network) is the standard mechanism used today to partition a
single Layer 2 bridging domain into multiple, separate, independent bridging domains.
Conceptually, each VLAN constitutes a bridged network.
FD1002S OLT equipment switch engine is fully compliant with the IEEE802.1Q VLAN
standard and has following main features.
All switch ports, including uplink ports and downlink ports support VLAN
24 / 62
FD1002S OLT User Manual-EMS Software
partition;
VLAN 1 is the system reserved VLAN, it includes all switch ports, all ports is
UNTAG mode;
宽带接入
VLAN Enable/Disable: 用心服务
Use the VLAN Enable option, manager can enable or disable VLAN feature.
When disabled, all ports working on VLAN Unaware mode.
25 / 62
FD1002S OLT User Manual-EMS Software
Port mirroring is used on a network switch to send a copy of network packets seen on
one switch port (or an entire VLAN) to a network monitoring connection on another
switch port. This is commonly used for network appliances that require monitoring of
network traffic, such as an intrusion detection system.
To use the port mirroring feature, you must designate one or more source ports and one
destination port. The source ports are the ports whose packets are mirrored and
monitored. The destination port is the port where the packets from the source ports are
copied and where the network analyzer is connected. There can be only one destination
port on the switch.
FD1002S switch engine support port mirroring. All switch ports, including uplink and
downlink ports, can be designated as source ports. One of four uplink port can be
宽带接入
designated as destination port.
用心服务
Open “Port Mirror” page to configure port mirroring function.
This part describes how to display and modify the switch port settings of
FD1002S. The switch ports of FD1002S includes 4 uplink ports (ge1~ge4) and
two downlink (connect with PON interface) ports. Fout uplink ports is identified
as ge1 to ge4 from uplink port 1 to 4, and two downlink ports is identified as
26 / 62
FD1002S OLT User Manual-EMS Software
Open “Switch and Control Card” management window. The “Port Property”
page contains the port configurable parameters and the “Port Status” page
displays the port working status parameters.
宽带接入
用心服务
The port list table on this page includes all of the six switch ports. Some
parameters are configurable for all ports and some other can only be configured
on uplink ports. The parameters displayed as gray style in this table cannot be
modified.
Port Enable
Uplink ports can be shut down by setting the Port Enable parameter as
“disable” status. Downlink ports can’t be disabled.
The speed and duplex mode for uplink ports can be configured. Speed
parameter can be set as 10M, 100M and 1000M in “copper” mode and fixed
as 1000M in “fiber” mode. Duplex mode supports Full Duplex, Half Duplex
and Auto Mode.
Flow Control
Port Priority
The default priority for uplink ports can be modified and the valid range is 0 to
7. The higher value has lower priority.
27 / 62
FD1002S OLT User Manual-EMS Software
Port VID
All ports default VLAN ID can be modified, and the valid VID range is 1 to
4094.
Nested VLAN
Uplink ports support rate limit for Broadcast, Multicast and Unknown Unicast
traffic. When one of these traffic type is limited, it will be transmitted under the
configured rate value. The rate units are Kbps and Kpps optional.
Link status, working speed, working duplex mode, flow control mode, and
etc.
6.2.8 ONUAuthentication
28 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
3) Click Add button to add a MAC or a MAC range to the “MAC Address List”
table when the authentication mode is not “Non-authority” mode.
4) Click Delete button to delete one or more MAC entry from the “MAC
Address List” table.
Authentication Mode
Non-authority
Black List
29 / 62
FD1002S OLT User Manual-EMS Software
When this mode is chosen, the MAC address whose attributes are
“blackMAC” will be considered as illegal MACs and the MAC address
whose attributes are “whiteMAC” will be ignored. The ONUs with illegal
MACs will be de-registered by OLT device. The ONUs with MACs that are
not included in the Black List can register to this OLT device normally.
White List
When this mode is chosen, the MAC address whose attributes are “whiteMAC” will be
considered as legal MACs and the MAC address whose attributes are “blackMAC” will
be ignored. Only those ONUs with legal MAC can register to this OLT device, and others
will be de-registered by this OLT device.
The “MAC Address List” table will be checked to judge if a MAC is legal or
illegal, when the authentication mode is enabled (Black List mode or White List mode).
宽带接入
User can add a unique MAC Address or a MAC Address range to this table by Add
operation. When do add operation, “Begin MAC” and “End MAC” should be input. A
unique MAC will be added if the two MAC Addresses are the same. When add a MAC
用心服务
Address range, the “End MAC” value should be different with the “Begin MAC”. Note that
the “End MAC” value should be numerical larger than the “Begin MAC” value.
This read-only table contains the illegal ONU register information, when
authentication function is enabled. Such as the illegal ONUs MAC Address and their
number of times try to register. This table contents can be cleared by click Clear button.
This section describes the management functions of EMS software to manage FD2000S
OLT device. Currently, FD1002S have two PON ports.
Double click the PON card icons in topology tree or the PON card graphic in chassis
management window to open the “PON Card Management” window. Following is a
typical page view.
30 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Open “Basic Information” windows, it displays the PON Card firmware version, Running
Time, and Running Status etc.
用心服务
The led indicators located on the front panel graphic display the PON module’s real time
working status. There are two LED on the left of the PON port, are indicator of status of
ONU connecter with the PON port.
On “Basic Information” page, user can reset the card, default the card to factory
configuration or save the configurations by click the corresponding operation
button.
31 / 62
FD1002S OLT User Manual-EMS Software
Open “Bridge Configuration” page, user can modify the following bridge
parameter settings:
The aging time for MAC Address learned on PON ports. The valid value range
is 0 to 2419200 seconds. When this value is 0, the MAC aging feature is
disabled. The default value is 300s.
MAC Overwrite
When this function is enabled, and the dynamic MAC table is full, new learned
MAC Address will overwrite the oldest MAC entries.
Discard Unknown MAC
When this function is enabled, the bridge engine will not forward unknown
unicast packets.
Forward TAG Frame on Simple Bridge
When this function is enabled, the bridge engine will forward all tag and
untagged frames. When this function is disabled, the bridge engine will forward
only untagged frames.
Note:
宽带接入
1) All the above parameters can only be modified when the PON ports are
disabled.
2)
用心服务
EMS software will disable all PON ports first automatically when modify the
above parameters, and then enable them when finished.
Due to the nature of the EPON network structure, the ONU device registered on the
same PON port cannot communicate with each other. This feature will affect some
special application. If the communication is required, the P2P (point to point) function
must be enabled.
On the “P2P Configuration” page, user can enable or disable this function.
Note:
1) This configuration can only be modified when the PON ports are disabled.
2) When change this configuration, EMS software will shutdown the PON ports
first, and then open them when change finished.
3) According to IEEE802.3 protocol, the point to point operation between ONUs
of the same PON port is not supported, so we do not recommend users to
enable this function, unless it is really needed.
6.3.6 LLID
Each ONU can register and get one or more LLID in EPON system. We can control the
number of users under each logic link (by MAC restrict).
Default MAC limit is 64,so each Logic Link can service to 64 user simultaneously.
宽带接入
Number of concurrent users can be configuredfrom 0 to 4095.
SLA refers to the Service Level Agreement. In EPON system, OLT device maintain a
SLA configuration for each registered Logical Link. SLA configurations include minimum
guaranteed bandwidth, maximum allowed bandwidth, delay sensitive, and maximum
burst size parameters.
By configuring different SLA parameters, EPON system can allocate different service
levels for different customers based on their service demands.
As above figure, SLA configurations for each PON port, Logical Link ID and
Direction are listed in the “SLA Configuration” table. Logical Link ID is assigned
by OLT device when ONU registered to it.
34 / 62
FD1002S OLT User Manual-EMS Software
Also called assured bandwidth, is the bandwidth that OLT will allocate to
this Logical Link assuredly. The valid value range is 0 to 1000000, unit is
kbps. The default value is 0.
Note: Total minimum guaranteed bandwidth for all Logical Links registered to per
PON port can’t exceed the max throughput value. Normally, it is 950Mbps
on downlink direction and 930Mbps on uplink direction. When exceed, the
guaranteed bandwidth may be not effective.
Maximum Allowed Bandwidth
Delay Sensitive
用心服务
This parameter can be set as “tolerant” or “sensitive”. The “sensitive”
option can only be set when the maximum allowed bandwidth is equal to
the minimum guaranteed bandwidth. Under this configuration, the Logical
Link will have lower delay performance.
The maximum allowed burst frame length on this Logical Link. The valid
range is 1 to 256, unit is Kbytes. The default value is 100. The default value
is recommended.
Note:
1) User can also view or modify the SLA configurations on “Logical Link-Link SLA”
page on “ONU Management” window. They have the same configuration results.
7 ONU Management
ONU is the user end device in EPON system. EMS software manages the
accessed ONU devices through their registered OLT device. OLT device
transmits management operations received from EMS software to accessed
35 / 62
FD1002S OLT User Manual-EMS Software
EMS software supports to manage various types ONU devices, such as 1FE
port type, 4FE port type, 4FE+2POTS type and 4FE+2POTS+1CATV type, etc,
as long as these ONU devices support standard OAM features.
This part introduces the management operations for EMS software to manage
4FE-port type ONU device. For other types, the mainly operations are the same
and different management features are introduced in their special sections.
Double click the selected ONU device icon on topology-tree list to open “ONU
Management” window. The function pages located on this window contain all
the management features for this type ONU device.
宽带接入
用心服务
RSTP Configuration
ACL Configuration
VLAN Management
36 / 62
FD1002S OLT User Manual-EMS Software
Usually, the device panel diagram will be displayed on the ONU management
window. On this diagram, all the working LED indicators show the actual working
status. See the following example figure.
宽带接入
用心服务
The bright green icon indicates light ON and the dark LED icon indicates light
OFF.
Open “Basic Configure” page, the ONU basic information is displayed on this
page.
On this page, user can view device type, MAC Address, ONU ID Number, Device
SN, Hardware Revision, Firmware Version, User Information, Max Allowed LLID Number,
Online Status and Range Value etc.
ONU ID
ONU ID is the ONU device ID number which is assigned by OLT device. ONU
ID is convent for user to identify per ONU device. ONU ID is a unique value for per PON
port, the range is 1 to 64. When an ONU device registered to a PON port, OLT assigned
an unused ONU ID value for it. This value will be bound with the ONU’s MAC Address
until the ONU device is deleted from this PON port (can only be deleted when offline).
When an ONU device is deleted from one PON port, the ONU ID value assigned for it will
be taken back. When the deleted ONU registered to this PON port again, it will be
assigned a random new ONU ID value.
Some types ONU device support multiple LLID, for these types device, user
can configure the maximum allowed LLID number for it. For OLT device, one LLID is
considered as a virtual ONU.
37 / 62
FD1002S OLT User Manual-EMS Software
User Information
This parameter is used for user to fill user special information for per ONU
device.
Range Value
This parameter is the optical link distance from OLT to ONU device measured
by OLT device.
Open “Basic Configure” page. User can do Reset, Default and Save operation for
宽带接入
per ONU device through the function buttons located on this page.
Through the “User Traffic Enable” function, user can enable or disable the service
traffic transmission.
用心服务
7.3 RSTP Configure and Port Isolation
RSTP
The Rapid Spanning Tree Protocol (RSTP) guard against the formation of loops
in an Ethernet network topology. Packets can become caught in repeating
cycles, referred to as broadcast storms, that needlessly consume network
bandwidth and that can significantly reduce network performance.
The ONU RSTP function applies on ONU user ports, used to prevent network
loop on these ports. When network loop occur, such as two user ports are
connected mistakenly, one of them will be shutdown automatically by STP
protocol.
38 / 62
FD1002S OLT User Manual-EMS Software
Port Isolation
For multiple user ports ONU equipments, Layer 2 switch among these ports is
supported usually. But for most access network build based on EPON
technology, the communication among local users is not needed in most case.
The network designer can turn on or off switch capability among ONU user
ports by setting “Port Isolation” parameter “enable/disable”.
This section describes the management function and parameter configuration for
宽带接入
ONU user ports.
用心服务
Port Working Status
Link Status, Speed and Duplex Working Status, Flow Control, Port Enable
Status and User Information parameters for all user ports can be viewed on
this page.
39 / 62
FD1002S OLT User Manual-EMS Software
Port Speed and Duplex working mode, User Information for per Port, Flow
Control and Port Enable parameters can be configured on this page.
Port Speed and Duplex parameters can be configured only when the port is
enabled and port link status is Up and Auto negotiation is disabled.
宽带接入
用心服务
Bridge mode parameters for per ONU port can be configured on this page.
These parameters include MAC Limit, MAC Aging Time and Forwarding Mode
etc.
MAC Limit
This parameter is used for network manager to control the maximum learned
MAC Address entries.
Forwarding Mode
The ONU user port forwarding mode can be configured as “drop until learned”
mode and “802.1d” mode by setting this parameter value as “dropUntilLearned”
or “d8021mode”. When the forwarding mode is “drop until learned” mode, only
the packets with learned source MAC Address will be forwarded, the un-learned
packets will be dropped. In “802.1d” mode, all received packets will be
forwarded based on 802.1d standard.
MAC Aging time can be configured for per user port, it is the aging time for
dynamic MAC Address entries in MAC Address table. The value unit is second. When
this value is set to 0, the learned MAC Address entries will not be aged out.
Open “MAC Address Management” page, manager can view the learned
dynamic MAC Address entries on each user port. Click Clear button to clear.
宽带接入
用心服务
ONU user ports support traffic management feature on both up and down
direction. Upstream direction (received on user port) traffic supports ingress policy
feature and downstream direction traffic supports egress shaping feature.
Ingress policy feature supports to configure the maximum data rate received on
41 / 62
FD1002S OLT User Manual-EMS Software
each user port based on selected packet type. The packet types to apply ingress policy
feature can be broadcast packet, multicast packet, all packets and
broadcast/multicast/DLF packets. The rate unit is kbps and maximum value is
100000kbps. The ingress policy feature can be disabled.
Egress shaping feature supports to configure the maximum output data rate on
each user port. And the rate limit mechanism can be “weight fair” or “strict priority”.
Loopback test function is used for network manager to test network performance
between OLT and ONU equipment. When do loopback test operation, test packets are
sent to target ONU device from OLT PON port and then these test packets are looped
back to OLT PON port by the ONU device. OLT software will compare the received test
packets with the packets sent from it to get the test results, such as sent and received
宽带接入
packets, error packets and delay performance. Network performance on the test optical
link can be evaluated based on the loopback test results.
用心服务
Open the “ONU Loopback Test” page. Typical page is shown below.
1) Before beginning loopback test, test packet number, frame length and
VLAN TAG should be set first. Set VLAN TAG as 0 indicates sent
un-tag frames.
4) When test finished, the test results will be shown on the result table.
42 / 62
FD1002S OLT User Manual-EMS Software
IGMP snooping can passively snoop on IGMP Query, Report and Leave (IGMP version 2)
packets transferred between IP Multicast Routers/Switches and IP Multicast hosts to
learn the IP Multicast group membership. It checks IGMP packets passing through it,
picks out the group registration information, and configures multicasting accordingly.
ONU maintains a table of relationship between a multicast MAC address and ONU ports.
When an ONU port receives a Host Membership Report message, ONU join this port to
the corresponding table entry. When the ONU receive a multicast packet, ONU check
this table to determine which ports to forward this packet.
IGMP global parameters include "multicast switching mode" and "fast leave enable”. The
following figure shows the “ONU IGMP Global Parameter Configure” Page.
宽带接入
用心服务
This mode is Host controllable mode for IPv4 and IPv6 multicast.
43 / 62
FD1002S OLT User Manual-EMS Software
When Fast Leave is enabled, forwarding of a group stops immediately upon reception of
a Leave message for that group. Note that this feature is only useful if it is known that
exactly one device downstream of the ONU can join a group. If more than one device is
attached to the ONU port though a switch or hub, then the first one to leave would stop
traffic to both devices.
宽带接入
用心服务
"IGMP Group" is used to configure how many multicast groups this ONU port can join in.
Click Add button on the "Multicast VLAN Configure" Panel to open the "Add IGMP
Multicast VLANs" window, as shown in the following figure:
Enter the Cos and the VID then click OK button to add a multicast group to this ONU port,
after that multicast streams contains this multicast VLAN Tag will be transmitted to this
port. Because the port receives a multicast stream with a VLAN Tag, so you will need to
configure the multicast VLAN Tag processing mode.
ONU supports three different VLAN tag processing mode: Not Strip VLAN Tag, Strip
VLAN Tag and Switch VLAN Tag。
Do not strip the VLAN Tag in the multicast stream. Multicast stream sent from this port
still contains a multicast VLAN Tag.
Strip the VLAN Tag in the multicast stream. Multicast stream sent from this port does not
contain a multicast VLAN Tag.
44 / 62
FD1002S OLT User Manual-EMS Software
Overwrite the VLAN Tag in the multicast packet then forward. This mode configuration
page as shown in the following figure:
宽带接入
用心服务
Click Add button on the "Multicast Strip Mode Configure" panel to open the "Add IGMP
Multicast VLANs" window, as shown in the following figure:
"Multicast VLAN" parameter is used to match VLAN Tag in the multicast streams. When
the VLAN Tag of the multicast streams is equal to this "Multicast VLAN", ONU overwrite
the VLAN Tag of the multicast with "IPTV User VLAN" then forward.
45 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Step 1: define the matching conditions
A matching condition consists of one or several (up to 8) matching rules. These matching
用心服务
rules are "and" relationship, namely only when all the rules are established, the matching
condition is established.
Rule operators: Rule operators compare the value of rule field in the incoming frame
with a specified value. The result is a Boolean value, either true or false. 8 of the
following Rule operators are supported:
Symbol Description
Matching value: The matching value is the value which specified by user used in the
bool comparison in a clause.
46 / 62
FD1002S OLT User Manual-EMS Software
Click the ">>" button to add the matching rule to the rules list.
Click the "<<" button to remove the selected rule in the rules list.
ACL rule can be applied to ONU PON port or UNI port. If an ACL is applied to PON ports,
then this ACL rule take effect for downstream packets. If an ACL is applied to UNI ports,
then this ACL rule take effect for upstream packets.
The defined range of precedence for user rules is from 8...13. 8 has the highest
precedence.
Two rules with conflicting actions may match the same frame. In this case, the action of
the rule with the highest precedence (lowest numerical value) is applied to the frame.
The action from the lower precedence rule is ignored.
宽带接入
Step 4: Specify action categories
When an Ethernet packet matches one or more ACL rules, it will be filtered or forward
according to the rule category. 用心服务
Action categories can be forward or discard a frame, set the Destination queue for a
frame, delete an existing VLAN tag, add a new VLAN tag, set VID, set CoS, and so on.
Step 5: Apply
Set up the ACL rule, click on the “Add” button to add the ACL rule to the ACL rule lists.
Click Apply button to apply all rules in the ACL rule list to the ONU.
ONUsupportsfourportVLANmodes:Transparent mode,Tag
mode,Translatemode,Trunkmode. These four modes are introduced as follows:
Transparent Mode
In this mode, upstream or downstream Ethernet packet received at this ONU port
forward without processing.
47 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Set button: apply the port VLAN configuration to this ONU port.
Tag Mode
用心服务
The method of an ONU port under tag mode process an Ethernet packet is shown in the
following table:
48 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Set button: apply the port VLAN configuration to this ONU port.
The method of an ONU port under trunk mode process an Ethernet packet is shown in
the following table:
49 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
Add button: add Translate entry. Click Add to open the Add VLAN window, shown as
below:
Click OK button after input the TPID and VID, a new translate entry will be added to the
VLAN Translate list. Up to 8 VLAN translate entry can be set for an ONU port.
Delete button: delete a VLAN translate entry selected in the VLAN Translate list.
Set button: apply the port VLAN configuration to this ONU port.
Trunk Mode
Trunk mode allows the port forward multiple VLANs at the same time, generally used for
the connection between the network equipment.
The method of an ONU port under trunk mode process an Ethernet packet is shown in
the following table:
50 / 62
FD1002S OLT User Manual-EMS Software
用心服务
If the packet’s VID not equal to the
port default VID and not exist in the
VLAN Trunk allow list, discard this
packet.
Add button: add allowed VLANs. Click Add to open the Add VLAN window, shown as
below:
51 / 62
FD1002S OLT User Manual-EMS Software
Click OK button after input the TPID and VID, a new entry will be added to the VLAN
Trunk allow list. Up to 16 allow VLAN entry can be set for this ONU port.
Delete button: delete a VLAN entry selected in the ONU VLAN list.
宽带接入
Set button: apply the port VLAN configuration to this ONU port.
用心服务
7.9 ONU Logical Link Management
Based on EPON protocol standard, OLT equipment will allocate one or more
Logical Link for each successfully registered ONU device. The Logical Link is also
called LLID simply. In downstream direction, OLT add LLID field to the received
standard Ethernet frames and then sent them to all registered ONU devices. ONU
device will only receive the frames with the same LLID value as the one it
registered. In upstream direction, OLT schedule and manage upstream packets
based on the Logical Links registered by ONU devices.
Open “ONU Management” window and go to “Logical Link” page to do Logical Link
management. Following subsections introduces the Logical Link management
features.
Open “Logical Link Status Management” page. Typical page is shown below.
52 / 62
FD1002S OLT User Manual-EMS Software
The “Current Logical Link” table shows all the Logical Links registered by this
宽带接入
ONU device. Each Logical Link is identified by its MAC Address. The Block and
Unblock button is used to block or unblock Logical Links. The Re-register
用心服务
button is used to force a Logical Link to reregister to OLT.
When a Logical Link is blocked, it will be deregistered and can’t reregister again
until it is unblocked later.
Open “Logical Link-Link MAC Management” page, typical page is shown below.
On this page, network manager can view or clear dynamic MAC Address
entries learned on each Logical Link. Can add or delete static MAC Address
entries on each Logical Link.
Logical Link MAC Address tables are maintained on OLT device. OLT forwards
downstream frames based on MAC Address table.
53 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
Open “Logical Link-Link SLA” page. Typical page is shown below.
On this page, network manager can configure SLA parameters for the Logical
Links registered by this ONU device.
用心服务
The Logical Link SLA management features here are accordant with the SLA
configurations introduced in PON card management section. Please refer to
subsection for detail introduction.
8 Alarm Management
EMS software receives alarm information sent from managed EPON equipments.
The alarm information is contained in TRAP messages based on SNMP protocol
standard. To receive TRAP messages sent from managed device, target IP Address
should be configured first. The target IP Address is the PC server’s IP Address on
which EMS software is installed. Please refer to section to learn the operations to
configure these parameters.
EMS software supports user defined alarm rule configuration. Based on defined rule,
alarm information can be classified or filtered.
Network manager can query current alarm and history alarm information occurred
on managed equipments by various search conditions.
54 / 62
FD1002S OLT User Manual-EMS Software
To open “Alarm Rule Configuration” window, from Alarm menu, then click Alarm
Rule Configuration. Following figure is a typical view.
宽带接入
用心服务
Choose the target device type in left column, such as “EPON_1U” OLT device. Then
the supported alarm items for the selected type will be shown on right part. Each
entry contains the alarm name, severity level and filter or not. Severity level is
configurable and classified as “Information”, “Minor”, “Major” and “Critical” four
levels. Different level alarms will be marked with different color in alarm window. Any
one of the supported alarm items can be filtered out according to requirement.
To open “Alarm Query” window, from “Alarm” menu, click Alarm Query. Following
figure is a typical view.
55 / 62
FD1002S OLT User Manual-EMS Software
宽带接入
用心服务
Alarm information can be queried by alarm time, alarm level, alarm status, alarm
device and alarm content. The query result can be saved as a file.
On the “Alarm Log” page located on the bottom of EMS main window or open
“Current Alarm” window, current alarm information can be viewed. Following figure
is a typical view.
56 / 62
FD1002S OLT User Manual-EMS Software
Operation log query feature is designed for network manager to trace back the
history operation records when needed. From Alarm menu, click System Log to
open operation log management window. Typical window view is shown below.
宽带接入
用心服务
History operation log can be filter out by operation user name and operation time
range. The query result can be saved as a excel file.
10 Database Maintenance
EMS database maintenance feature includes database backup and restore two
functions. Most of the configuration information for EMS software, such as added
device and location node, device name and user name etc. are saved in software
database. To avoid configuration loss when system halted, network manager need
to backup database constantly. The backup database can be restored to retrieve
the original configuration when needed, such as operating system reinstalled or
EMS reinstall.
57 / 62
FD1002S OLT User Manual-EMS Software
On the pop-up database restore window, only the files saved at system default
directory will be list. If the backup files were moved to other location, they must be
copied to the default directory first. The system default location for saving database
files is “…\EMS\EMS Server\backupDB” directory.
宽带接入
11 User Accounts Management
用心服务
EMS software supports multi-user operation, and set different privilege for different
user to improve system security. Network managers can add or delete user
accounts or modify their information.
Following figure is a typical operation view.
Deleting a User
To delete a user account, do the following:
1) Choose the user account entry list in user accounts table.
2) Click Delete button icon.
3) Click Save button icon to save the results.
12 System Upgrade
EMS software supports device firmware on-line upgrade. The main procedure for device
upgrading is two steps. First, download firmware files to target devices to be upgraded.
Then target device will go through the whole firmware update process according to
upgrade commands received from EMS.
Install a FTP server program on the management PC if you have not. Then start the FTP
server. There is a third party FTP server program “WFTPD” if EMS is fully installed.
Following introduce take “WFTPD” as a sample. There may be some different if the FTP
server is not WFTPD. In such condition, please refer to the software user manual.
From the Security menu of “WFTPD” program, select Users/rights item to open the
user security dialog window. Configure the username, access password and home
directory information. Typical configuration window is shown below.
59 / 62
FD1002S OLT User Manual-EMS Software
2. Copy the device firmware files to be update to the home directory of FTP server
program.
3. 宽带接入
EMS Upgrade Parameters Configuration
1) From Configure menu, select Device Upgrade. Device upgrade window will appear.
Typical view is shown as below. 用心服务
2) Choose the OLT device to be upgraded from the device list on the left column of window.
3) Input FTP Server IP Address, User Name, Password and Firmware file name on the
“Upgrade Configure” page.
The supported upgrade targets may be different for different type devices. For FD2000S
OLT device, for example, the supported upgrade targets include switch and control card
firmware, PON card firmware, PON chip firmware, PON card configuration files and PON
chip boot file.
For per target file object, some index parameters need to be chosen to specify the
specific device object to be upgraded. For example, if the file target is for PON card
object, then PON card slot index need to be chosen. One or more number index can be
specified at the same time.
6) CRC Check
In order to avoid upgrade an error file to target devices, CRC check function can be used.
Before downloading file to devices, the Calculate CRC tool button can be used to
calculate the CRC result of the selected file. When the file is transmitted to target device,
the device firmware will recalculate the CRC result and then compare this result with the
CRC value received from EMS. Such feature will avoid error file is upgraded to device.
4. Upgrade Operation
宽带接入
When the upper needed upgrade configurations are finished, according to following
steps to finish device upgrade procedure.
1)
用心服务
Click Download to Device button
In this step, the FTP client program running on device will download the target file from
the specified FTP server. When finished successfully, the ‘Progress Status’ will display
‘transmit ok’ result.
In this step, the target device will update the specified file with the new received file.
When finished successfully, the Process Status will display “upgrade ok” result.
The new upgrade file will take effect when the target device reboot.
Whole upgrade process finished when the target device boot up with the upgraded new
files.
61 / 62
FD1002S OLT User Manual-EMS Software
End
Technology!
Contact:
Company Address:Flat 6, #4, South 2 of Honghualing Industrial Zone,Xili, Nanshan, Shenzhen China
Factory Address:Flat 8, #2, South 2 of Honghualing Industrial Zone,Xili, Nanshan, Shenzhen China
Tel:+86-755-26014509/26014710/26014711
Fax:+86-755-26014506
宽带接入
Mail:Marketing@cdatatec.com
Web: www.cdatatec.com
用心服务
62 / 62