You are on page 1of 119

Reed auto switches Solid state auto switches

Best

1264
D-P7
D-B3
D-A9
D-H7

D-M5
D-M9

D-F8
D-F6
D-H7C

D-F59F
D-F79F
D-J79C
D-G59F

D-F5/J5
D-F7/J7

D-Z7/Z8
D-H7NF

D-F7V

D-A9V
D-A59W
D-A79W
D-B59W
2

D-A5/A6
D-A7/A8
D-A3/A4
D-B5/B6
D-C7/C8
D-M9V
D-G5/K5

D-F9G/H
D-Y7G/H

D-F7NJL
D-H7W

D-F5NTL
D-F7NTL

D-M5W
D-M9W
D-F5BAL
D-F7BAL

D-Y7BAL
D-G5NTL
D-H7BAL

D-G5BAL

D-G5NBL
D-M5TL

D-P4DWL
D-M9AL

D-P3DW
D-F7BAVL

D-M9WV
D-G39/K39

D-M9AVL
D-F7W (V)
Bore size

D-A73C/A80C
D-C73C/C80C
D-G39C/K39C
D-G39A/K39A

D-E7A/E80A
D-A7H/A80H
D-A3C/A44C
D-A3A/A44A
D-F5W/J59W
D-G5W/K59W
Cylinder series

D-Y7W/Y7WV

(: Best Pneumatics)


D-Y5/Y6/Y7/Y7V

Actuator page reference


ø4
P.21 CDJP2
ø6, ø10, ø16
ø6
P.39 CDJ2
ø10, ø16
Pneumatics

P.125 ø20 to ø40 CDM2


ø20 to ø40 CDM3
ø20 to ø63
P.219 CDG1
ø80, ø100
Applicable Cylinder Series 1

ø20, ø63
CDG3
ø80, ø100
P.285 ø32 to ø125 MDB
P.1515 ø40 to ø100 MDB-X1184
Auto Switch Guide

P.329 ø32 to ø125 MDB1


P.353 ø40 to ø100 CDA2
P.1516 ø40 to ø100 CDA2-X1184
P.409 ø125 to ø200 CDS1
P.447 ø125 to ø160 CDS2
P.463 ø6 to ø20 CDUJ
P.479 ø6 to ø32 CDU
ø12 to ø20
P.547 CDQS
ø25
ø12 to ø25
ø32 to ø100
P.599 CDQ2
ø125 to ø160
ø180 to ø200
P.1410 ø16 to ø63 CDQ2-XB14
ø20, ø25
P.771 RDQ
ø32 to ø50
ø12 to ø25
P.791 CDQM
ø32 to ø100
ø20 to ø40 CQU
ø25 to ø63 MDU-Z
ø10, ø16 CDJ5·S
P.833
ø20 to ø100 CDG5·S
ø20 to ø63
P.854 HYDB
ø80, ø100
P.858 ø20 to ø63 HYDQ
Reed auto switches Solid state auto switches

D-P7
D-B3
D-A9
D-H7

D-M5
D-M9

D-F8
D-F6
D-H7C

D-F59F
D-F79F
D-J79C
D-G59F

D-F5/J5
D-F7/J7

D-Z7/Z8
D-H7NF

D-F7V

D-A9V
D-A59W
D-A79W
D-B59W

D-A5/A6
D-A7/A8
D-A3/A4
D-B5/B6
D-C7/C8
D-M9V
D-G5/K5

D-F9G/H
D-Y7G/H

D-F7NJL
D-H7W

D-F5NTL
D-F7NTL

D-M5W
D-M9W
D-F5BAL
D-F7BAL

D-Y7BAL
D-G5NTL
D-H7BAL

D-G5BAL

D-G5NBL
D-M5TL

D-P4DWL
D-M9AL

D-P3DW
D-F7BAVL

D-M9WV
D-G39/K39

D-M9AVL
D-F7W (V)
Bore size

D-A73C/A80C
D-C73C/C80C
D-G39C/K39C
D-G39A/K39A

D-E7A/E80A
D-A7H/A80H
D-A3C/A44C
D-A3A/A44A
D-F5W/J59W
D-G5W/K59W
Cylinder series

D-Y7W/Y7WV

(: Best Pneumatics)


D-Y5/Y6/Y7/Y7V

Actuator page reference


P.867 ø32 to ø63 HYDC
P.873 ø32 to ø63 HYDG
ø25 to ø32 MY1B-Z
ø10 to ø20
ø25 to ø40, ø63 to ø100 MY1B
ø50
ø16, ø20
MY1M
ø25 to ø63
P.943
ø16, ø20
MY1C
ø25 to ø63
ø10 to ø20
MY1H
ø25 to ø40
ø50, ø63 MY1HT
ø16, ø20
P.1057 MY1W
ø25 to ø63
P.1085 ø16, ø25, ø40 MY2
P.1121 ø16 to ø63 MY3
ø6 to ø20
P.1178 CY3R
ø25 to ø63
P.1189 ø6 to ø40 CDY1S/CY1L
P.1213 ø10 to ø32 CY1H
P.1229 ø10, ø15, ø25 CY1F
P.1249 ø15, ø32 CYP
P.15 ø6 to ø20 MXH
P.35 ø6 to ø16 MXU
P.49 ø6 to ø25 MXS
P.87 ø6 to ø25 MXQ/MXQR
P.133 ø8 to ø20 MXF
P.147 ø8 to ø25 MXW
P.169 ø4, ø6, ø8 MXJ
P.189 ø6 to ø16 MXP
P.213 ø6, ø10, ø12, ø16 MXY
P.229 ø8 to ø40 MTS
P.255 ø6, ø10 MGJ
Applicable Cylinder Series 1

ø12 to ø20
P.263 ø25 MGP
ø32 to ø100

1265
D-
Auto Switch Guide
Reed auto switches Solid state auto switches
Best

1266
D-P7
D-B3
D-A9
D-H7

D-M5
D-M9

D-F8
D-F6
D-H7C

D-F59F
D-F79F
D-J79C
D-G59F

D-F5/J5
D-F7/J7

D-Z7/Z8
D-H7NF

D-F7V

D-A9V
D-A59W
D-A79W
D-B59W
2

D-A5/A6
D-A7/A8
D-A3/A4
D-B5/B6
D-C7/C8
D-M9V
D-G5/K5

D-F9G/H
D-Y7G/H

D-F7NJL
D-H7W

D-F5NTL
D-F7NTL

D-M5W
D-M9W
D-F5BAL
D-F7BAL

D-Y7BAL
D-G5NTL
D-H7BAL

D-G5BAL

D-G5NBL
D-M5TL

D-P4DWL
D-M9AL

D-P3DW
D-F7BAVL

D-M9WV
D-G39/K39

D-M9AVL
D-F7W (V)
Bore size

D-A73C/A80C
D-C73C/C80C
D-G39C/K39C
D-G39A/K39A

D-E7A/E80A
D-A7H/A80H
D-A3C/A44C
D-A3A/A44A
D-F5W/J59W
D-G5W/K59W
Cylinder series

D-Y7W/Y7WV

(: Best Pneumatics)


D-Y5/Y6/Y7/Y7V

Actuator page reference


P.337 ø12 to ø100 MGQ
ø20 to ø63
P.353 MGG
ø80 to ø100
P.391 ø20 to ø50 MGC
Pneumatics

P.409 ø40, ø63, ø100 MGF


P.421 ø20 to ø80 MGZ
P.449 ø63 to ø100 MGT
P.461 ø10, ø15, ø25 CX2
Applicable Cylinder Series 2

ø10
CDBXW
P.473 ø16 to ø32
ø10 to ø32 CDPXW
ø12 to ø25
Auto Switch Guide

P.521 CXT
ø32, ø40
ø6, ø10 CXSJ
P.535
ø6 to ø32 CXS
ø16 CDLJ2
ø20 to ø40 CDLM2
P.593 ø20 to ø40 CDLG1
ø40 to ø100
CDL1
ø125 to ø160
P.657 ø20 to ø40 MLGC
P.669 ø20 to ø40 CDNG
P.693 ø32 to ø100 MDNB
P.723 ø40 to ø100 CDNA2
P.757 ø125 to ø160 CDNS
P.781 ø125 to ø200 CDLS
ø20
P.809 ø25 CDLQ
ø32 to ø100
P.839 ø32 to ø63 RDLQ
P.863 ø25 to ø50 MDLU
ø20
P.881 ø25 MLGP
ø32 to ø100
P.909 ø25 to ø40 ML1C
ø10, ø15, ø20
P.925 REAR
ø25 to ø40
Applicable Cylinder Series 2

Auto Switch Guide


MK/MK2

CLKQG
CDQSY

CDQSX
CDM2Y

CDM2X

CLKQP
CDQ2Y

CDG1Y

CDQ2X

CLK2G
CDA2Y
CDS2Y
Cylinder series

CLK2P
CDJ2X

MK2-Z

CKQG

CKQP
REAH
REBR

REBH

CDUX
REAS

CKG1
REAL

MK2T

CKP1
RHC
REC

RZQ

ø12, ø16, ø32 to ø63


ø125 to ø160
ø32 to ø100

ø40 to ø100

ø32 to ø100

ø80 to ø100
ø10 to ø40
ø10 to ø40
ø10 to ø32

ø15 to ø32
ø20 to ø40
ø12 to ø20

ø20 to ø40
ø20 to ø63

ø10 to ø16
ø10 to ø32
ø12 to ø20

ø20 to ø40
ø20 to ø63

ø32 to ø63
ø12 to ø63
ø20 to ø63

ø20 to ø63

ø40 to ø63
ø40 to ø63
ø40 to ø63
ø40 to ø63
ø80, ø100
ø25, ø32
Bore size
ø15

ø25

ø25

ø50
ø50
ø50
ø50
D-H7
D-H7C
D-H7BAL
D-H7NF
D-H7W
D-G5/K5
D-G5BAL
D-G59F
D-G5NTL
D-G5W/K59W
D-G39/K39
D-G39A/K39A
D-F7/J7
D-J79C
D-F79F
D-F7BAL
D-F7BAVL
D-F7V
Solid state auto switches

D-F7NTL
D-F7W (V)
D-F5/J5
D-F5BAL
D-F5W/J59W
D-F59F
D-F5NTL
D-G39C/K39C
D-M9
D-M9V
D-M9W
D-M9WV
D-M9AL
D-M9AVL
D-Y5/Y6/Y7/Y7V
D-Y7BAL
D-Y7W/Y7WV
D-M5
D-M5W
D-M5TL
D-P3DW
D-P4DWL
D-F9G/H
D-Y7G/H
D-G5NBL
D-F7NJL
D-F6
D-F8
D-C7/C8
D-C73C/C80C
D-B5/B6
D-B59W
D-A3/A4
D-A3A/A44A
Reed auto switches

D-A3C/A44C
D-A7/A8
D-A7H/A80H
D-A73C/A80C
D-A79W
D-A5/A6
D-A59W
D-A9
D-A9V
D-E7A/E80A D-
D-Z7/Z8
D-P7
D-B3
P.1023

P.1047

P.1111

P.1195

P.1217

P.1233

P.1265

P.1317

P.1344
P.925

Actuator page reference


(: Best Pneumatics)

1267
Best Pneumatics
2 Auto Switch Guide

Applicable Cylinder Series 3

CDVM5K

CDVM3K
ø8, ø12, ø20, ø25, ø32 MIS/MIW

CDVS1K
CDVM5

CDVM3

CDV3K
CDVS1
Cylinder series

CDVJ5
CDVJ3

MVGQ
CVQM
RSDQ

RSDG

ML2B

CDV3
CEP1

CVQ
RSH

CE1

CE2
ø32, ø40, ø50

ø40 to ø100

ø40 to ø100

ø40 to ø100

ø12 to ø100
ø20 to ø80

ø32 to ø63

ø25 to ø40
ø32 to ø63
ø32 to ø63

ø20 to ø40
ø20 to ø40
ø20 to ø40
ø20 to ø40

ø40 to ø63

ø40 to ø63
ø16, ø20

ø40, ø50

ø12, ø20
ø12, ø20

ø10, ø16
ø10, ø16
Bore size
ø12

D-H7
D-H7C
D-H7BAL
D-H7NF
D-H7W
D-G5/K5
D-G5BAL
D-G59F
D-G5NTL
D-G5W/K59W
D-G39/K39
D-G39A/K39A
D-F7/J7
D-J79C
D-F79F
D-F7BAL
D-F7BAVL
D-F7V
Solid state auto switches

D-F7NTL
D-F7W (V)
D-F5/J5
D-F5BAL
D-F5W/J59W
D-F59F
D-F5NTL
D-G39C/K39C
D-M9
D-M9V
D-M9W
D-M9WV
D-M9AL
D-M9AVL
D-Y5/Y6/Y7/Y7V
D-Y7BAL
D-Y7W/Y7WV
D-M5
D-M5W
D-M5TL
D-P3DW
D-P4DWL
D-F9G/H
D-Y7G/H
D-G5NBL
D-F7NJL
D-F6
D-F8
D-C7/C8
D-C73C/C80C
D-B5/B6
D-B59W
D-A3/A4
D-A3A/A44A
Reed auto switches

D-A3C/A44C
D-A7/A8
D-A7H/A80H
D-A73C/A80C
D-A79W
D-A5/A6
D-A59W
D-A9
D-A9V
D-E7A/E80A
D-Z7/Z8
D-P7
D-B3
P.1371

P.1387
P.1401
P.1415

P.1437

P.1483
P.1505
P.1527

P.1542

P.1563

P.1604

P.1624

P.1643

Actuator page reference


(: Best Pneumatics)

1268
Applicable Cylinder Series 3/Auto Switch Variations 1

Auto Switch Guide


Auto Switch Variations 1
Auto switch
Function Type Electrical entry Auto switch model Page
mounting style

D-H7A1/H7A2/H7B 1278
Grommet
D-G59/G5P/K59 1279
Band Connector D-H7C 1280
D-G39/K39 1281
Terminal conduit
D-G39A/K39A 1282
D-F79/F7P/J79 1283
Grommet
Rail D-F7NV/F7PV/F7BV 1284
Solid state

Connector D-J79C 1285


Grommet D-F59/F5P/J59/J51 1286
Tie-rod
Terminal conduit D-G39C/K39C 1287
D-M9N/M9P/M9B∗
1288
D-M9NV/M9PV/M9BV∗
D-F8N/F8P/F8B 1289
General purpose auto switches

D-F9G/F9H∗(Normally closed) 1290


Direct Grommet
D-Y59A/Y59B/Y7P∗∗
1291
D-Y69A/Y69B/Y7PV∗∗
D-Y7G/Y7H∗∗(Normally closed) 1292
D-M5N/M5P/M5B 1293

D-C73/C76/C80 1332
Grommet
D-B53/B54/B64 1333
Connector D-C73C/C80C 1334
Band D-A33/A34 1335
Terminal conduit
D-A33A/A34A 1336
D-A44 1335
DIN terminal
D-A44A 1336
D-A72/A73/A80 1337
Reed

Grommet
Rail D-A72H/A73H/A76H/A80H 1338
Connector D-A73C/A80C 1339
Grommet D-A53/A54/A56/A64/A67 1340
Tie-rod Terminal conduit D-A33C/A34C
1341
DIN terminal D-A44C
D-A90/A93/A96∗
1342
D-A90V/A93V/A96V∗
Direct Grommet
D-Z73/Z76/Z80∗∗ 1343
D-E73A/E76A/E80A 1344
* These auto switches can be mounted with a band (except D-A9쏔V and M9쏔V), a rail, a tie-rod or a square groove when auto switch mounting brackets
are used. Refer to pages 1356, 1360, 1364, 1368 and 1369 for details.
** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 1367 for details.

Band mounting Rail mounting Tie-rod mounting Direct mounting

D-쏔

1269 A
2-2-44-UMASw-sTaikei.qxd 09.11.11 2:52 PM Page 1

Best Pneumatics
2 Auto Switch Guide

Auto Switch Variations 2


Auto switch
Function Type Electrical entry Auto switch model Page
mounting style

D-H7NW/H7PW/H7BW 1294
Band Grommet
D-G59W/G5PW/K59W 1295
D-F79W/F7PW/J79W 1296
Rail Grommet
Solid state

D-F7NWV/F7BWV 1297
2-color indication

Tie-rod Grommet D-F59W/F5PW/J59W 1298


D-M9NW/M9PW/M9BW∗
1299
D-M9NWV/M9PWV/M9BWV∗
Direct Grommet D-Y7NW/Y7PW/Y7BW∗∗
1300
D-Y7NWV/Y7PWV/Y7BWV∗∗
D-M5NW/M5PW/M5BW 1301

Band Grommet D-B59W 1345


Reed

Rail Grommet D-A79W 1346


Tie-rod Grommet D-A59W 1347
* These auto switches can be mounted with a band (except D-M9쏔WV and M9쏔AVL), a rail, a tie-rod or a square groove when auto switch mounting
brackets are used. Refer to pages 1356, 1360, 1364, 1368 and 1369 for details.
** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 1367 for details.

2-color indication

Easily identifiable, proper operating range


쎲Mounting positions can be set easily.
Proper operating range can be set while
watching the lights.
Red

쎲Displacement of the detecting


Green
Red

position can be visually checked.


Trouble caused by incorrect detection can be
prevented beforehand.
ON
Red Green Red OFF
Proper operating range

Operating range

Even if 2-color indication solid state auto switches are fixed at a proper operating range (the green light lights up), the operation may
become unstable depending on the installation environment or magnetic field disturbance.
(Magnetic body, external magnetic field, proximal installation of cylinders with built-in magnet and actuators, temperature change, other factors
for magnetic force fluctuation during operation, etc.)

Band mounting Rail mounting Tie-rod mounting Direct mounting

1270
2-2-44-UMASw-sTaikei.qxd 09.9.30 3:25 PM Page 1

Auto Switch Variations 2

Auto Switch Guide


Auto switch
Function Type Electrical entry Auto switch model Page
mounting style
The diagnostic output signal can be detected in an unsteady detecting area.
diagnostic output
2-color indication

D-H7NF
auto switch with

Solid state

1302
Band Grommet
D-G59F 1303
Rail Grommet D-F79F 1304
Tie-rod Grommet D-F59F 1305

Water resistant (coolant) type


D-H7BAL 1306
Water resistant 2-color
indication auto switch

Band Grommet
D-G5BAL 1307
Solid state

D-F7BAL
Rail Grommet 1308
D-F7BAVL
Tie-rod Grommet D-F5BAL 1309
D-M9쏔A∗
1310
Direct Grommet D-M9쏔AV∗
D-Y7BAL∗∗ 1311
Hygienic type
Hygienic

Solid
state

Direct Grommet D-F6N/F6P/F6B 1312

With built-in OFF-delay timer (200 ms)


Auto switch

Solid state

Band Grommet D-G5NTL 1313


with timer

Rail Grommet D-F7NTL 1314


Tie-rod Grommet D-F5NTL 1315
Direct Grommet D-M5NTL/M5PTL 1316
Can be used in an environment where magnetic field disturbances are generated. D-P3DWSC/P3DWSE 1317-1
Rail, Tie-rod, Direct Grommet
Solid
Magnetic field

state

D-P3DW 1317-2
auto switch
resistant

D-P4DWSC/P4DWSE 1317-3
Rail Grommet
D-P4DWL 1318
Reed

D-P79WSE 1348
Rod Grommet
D-P74 1349
Can be used in a high-temperature environment (Max. 150°C).
Solid
state
Heat resistant

Sensor unit: Rail


auto switch

Grommet D-F7NJL 1319


Amplifier unit: DIN rail
Reed

Terminal conduit D-B30/31/35


Band 1351
Grommet D-B30J/31J/35J

Wide range detection type


auto switch
Wide range
detection

Solid
state

Band Grommet D-G5NBL 1320

Simple workpiece recognition is possible.


auto switch
Trimmer

Solid
state

Rail D-F7K/Y7K
Grommet 1321
Direct (D-RNK/RPK is required.)

* These auto switches can be mounted with a band (except D-M9쏔WV and M9쏔AVL), a rail, a tie-rod or a square groove when auto switch mounting
brackets are used. Refer to pages 1356, 1360, 1364, 1368 and 1369 for details.
** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 1367 for details.
2-color indication type with diagnostic output Water resistant 2-color indication type Hygienic With timer

D-쏔
Magnetic field resistant Heat resistant Wide range detection Trimmer auto switch
Sensor unit Amplifier unit

1271
2-2-45-UMASw-Gosiyo.qxd 09.9.30 3:25 PM Page 1

Prior to Use
Auto Switches Common Specifications 1

Specific Product Precautions


Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches.

Auto Switches Common Specifications


Type Reed auto switch Solid state auto switch
Leakage current None 3-wire: 100 µA or less, 2-wire: 0.8 mA or less
Operating time 1.2 ms 1 ms or less (3)
Impact resistance 300 m/s2 1000 m/s2 (4)
Insulation resistance 50 MΩ or more at 500 VDC Mega (Between lead wire and case)

1500 VAC for 1 minute (1) 1000 VAC for 1 minute


Withstand voltage
(Between lead wire and case) (Between lead wire and case)

Ambient temperature –10 to 60°C


Enclosure IEC60529 Standard IP67 (2)
∗ 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min. (Between lead wire
and the case)
∗ 2) The terminal conduit type (D-A3/A3쏔A/A3쏔C/G39/G39A/G39C/K39/K39A/K39C), DIN terminal
type (D-A44/A44A/A44C) and heat resistant auto switch (D-F7NJL) conform to IEC60529
Standard IP63. The trimmer type amplifier section (D-R쏔K) conforms to IP40.
∗ 3) Excluding the solid state auto switches with a timer (D-M5쏔TL/G5NTL/F7NTL/F5NTL types) and
magnetic field resistant 2-color indication solid state auto switch (D-P3DW쏔/P4DWL). The
operating time for D-J51 is 2 ms or less and for D-P3DW쏔/P4DWL is 40 ms or less.
∗ 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

Lead Wire
Lead wire length indication Solid state auto switch oil resistant flexible cabtire cord indication
(Example) Add a -61 at the end of the part number for the solid state auto switch flexible
cord except D-Y59쏔, D-Y69쏔, D-Y7쏔, D-M9쏔/M9쏔V, and D-M9쏔W/M9쏔WV.
D-M9BW L
(Example)
Lead wire length
Nil 0.5 m D-F7PL- 61
M 1m
L 3m Flexible specification
Z 5m (D-Y59, D-Y69, D-Y7 and D-M9 series use flexible lead wire as standard. )
N∗ None
∗ Applicable for the connector type (D-쏔쏔C) only. Lead wires with a connector indication

Note 1) Lead wire length Z: 5 m


Part No. of Lead Wires with Connectors
(Applicable only for connector type)
Applicable auto switches
Reed auto switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C, Model Lead wire length
D-A53/A54, D-Z73, D-90/97/90A/93A D-LC05 0.5 m
Solid state auto switch: Manufactured upon receipt of order as standard. D-LC30 3m
Note 2) The standard lead wire length for trimmer auto switches is 3 m.
D-LC50 5m
Note 3) The standard lead wire length for solid state auto switches with a timer,
water resistant 2-color indication solid state auto switches, wide range
detection type solid state auto switches, heat resistant 2-color
indication solid state auto switches and magnetic field resistant 2-color
indication solid state switches is 3 m and 5 m (except D-P3DW, D-
M9쏔A(V)쏔). (0.5 m is not available.)
Note 4) 1 m (M): D-M9쏔(W)(V) only
Note 5) Lead wire length tolerance

Lead wire length Tolerance


0.5 m ±15 mm
1m ±30 mm
3m ±90 mm
5m ±150 mm

1272
P1263-P1276-E.qxd 08.10.3 2:40 PM Page 1273

Prior to Use
Auto Switches Common Specifications 2

Specific Product Precautions


Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches.

Auto Switch Hysteresis Contact Protection Box: CD-P11, CD-P12


Hysteresis is the distance between the position at which piston movement <Applicable switch models>
operates an auto switch to the position at which reverse movement turns D-A7/A8, D-A7쏔H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C80C, D-
the switch off. This hysteresis is included in part of the operating range E7쏔A, E80A, D-Z7/Z8, D-9/9쏔A, D-A9/A9쏔V, and D-A79W type
(one side). The auto switches above do not have a built-in contact protection circuit.
A contact protection box is not required for solid state auto switches due
to their construction.
q Where the operation load is an inductive load.
Auto switch w Where the wiring length to load is greater than 5 m.
e Where the load voltage is 100/200 VAC.
Therefore, use a contact protection box with the switch for any of
Switch the above cases:
operating The contact life may be shortened (due to permanent energizing
Note)
position conditions.)
(ON) Hysteresis Reed auto switch: 2 mm or less
Solid state auto switch: 1 mm or less D-A72(H) must be used with the contact protection box regardless
of load types and lead wire length since it is greatly affected by
loads.
(Where the load voltage is 110 VAC)
When the load voltage is increased by more than 10% to the rating of
Switch applicable auto switches (except D-A73C/A80C/C73C/C80C/90/97/A79W)
operating above, use a contact protection box (CD-P11) to reduce the upper limit of the
position load current by 10% so that it can be set within the range of the load current
(OFF)
range, 110 VAC.
Note) Hysteresis may fluctuate due to the operating environment. Even for the built-in contact protection circuit type (D-A34[A][C], D-
Please contact SMC if hysteresis causes an operational problem. A44[A][C], D-A54/A64, D-A59W, D-B59W), use the contact protection
box when the wiring length to load is very long (over 30 m) and PLC
(Programmable Logic Controller) with a large inrush current is used.

Contact Protection Box Specifications


Part no. CD-P11 CD-P12
Load voltage 100 VAC or less 200 VAC 24 VDC
Max. load current 25 mA 12.5 mA 50 mA
∗ Lead wire length — Auto switch connection side 0.5 m
Load connection side 0.5 m
Contact Protection Box Internal Circuit
CD-P11 OUT Brown
Choke
Surge absorber coil ~
OUT Blue

CD-P12 OUT (+) Brown


Choke
Zener diode coil
OUT (–) Blue

Contact Protection Box/Dimensions

Contact Protection Box Connection


To connect a switch unit to a contact protection box, connect the lead wire
from the side of the contact protection box marked SWITCH to the lead
wire coming out of the switch unit. Keep the switch as close as possible to
the contact protection box, with a lead wire length of no more than 1
D-쏔
meter.

1273
P1263-P1276-E.qxd 08.10.3 2:40 PM Page 1274

Prior to Use
Auto Switches Connection and Example
Basic Wiring
Solid state 3-wire, NPN Solid state 3-wire, PNP 2-wire (Solid state) 2-wire (Reed switch)
Brown Brown Brown Brown
Load Load
Load Indicator
Main Main Main
curcuit Black curcuit curcuit protection
Black ~
of switch of switch of switch circuit,
Load etc.
Blue Blue Blue Blue
(Power supply for switch and load are separate)
Brown Brown Brown

Load Indicator
Main Main protection
curcuit Black curcuit ~
of switch of switch circuit,
etc.
Load Load
Blue Blue Blue

Example of Connection with PLC (Programmable Logic Controller)


• Sink input specifications • Source input specifications Connect according to the applicable PLC
input specifications, as the connection
3-wire, NPN 3-wire, PNP method will vary depending on the PLC
Black Input Black Input
input specifications.
Brown Brown
Auto switch Auto switch
Blue Blue
COM COM
PLC internal circuit PLC internal circuit

2-wire 2-wire
Brown Input Blue Input

Auto switch Auto switch

Blue COM Brown COM


PLC internal circuit PLC internal circuit

Example of AND (Series) and OR (Parallel) Connection


• 3-wire
AND connection for NPN output AND connection for NPN output OR connection for NPN output
(Using relays) (Performed with auto switches only)
Brown Brown Brown
Load
Black Black Black
Auto switch 1 Relay Auto switch 1 Load Auto switch 1 Load
Blue Relay Blue Blue
contact
Brown Brown Brown
Black Black Black
Auto switch 2 Relay Auto switch 2 Auto switch 2
Blue Blue Blue

The indicator lights will light up when


both auto switches are turned ON.
• 2-wire
2-wire with 2-switch AND connection 2-wire with 2-switch OR connection
When two auto switches (Solid state auto switch) (Reed auto switch)
Brown are connected in series, a Brown When two auto switches Because there is no
Load load may malfunction Load are connected in parallel, current leakage, the load
Auto switch 1 because the load voltage Auto switch 1
Blue
malfunction may occur voltage will not increase
Blue
will decline when in the ON because the load voltage when turned OFF.
state. will increase when in the However, depending on
Brown The indicator lights will light Brown OFF state. the number of auto
Auto switch 2 up when both of the auto Auto switch 2 switches in the ON state,
switches are in the ON the indicator lights may
Blue Blue
state. sometimes grow dim or
not light up, due to the
Load voltage at ON = Power supply voltage – Residual voltage x 2 pcs. Load voltage at OFF = Leakage current x 2 pcs. x Load impedance dispersion and reduction
= 24 V – 4 V x 2 pcs. = 1 mA x 2 pcs. x 3 kΩ of the current flowing to
= 16 V =6V the auto switches.
Example: Power supply is 24 VDC Example: Load impedance is 3 kΩ.
Internal voltage drop in auto switch is 4 V. Leakage current from auto switch is 1 mA.
1274
2-2-46-UMASw-NakaT.qxd 09.10.1 3:13 PM Page 1

Best 2 Pneumatics

Auto Switch Guide


Auto Switch Guide

Solid State Auto Switches P.1277


General Purpose Type Band, Rail, Tie-rod, Direct Mounting P.1278

2-Color Indication Type Band, Rail, Tie-rod, Direct Mounting P.1294

2-Color Indication Type with Diagnostic Output Band, Rail, Tie-rod Mounting P.1302

Water Resistant 2-Color Indication Type Band, Rail, Tie-rod, Direct Mounting P.1306

Hygienic Direct Mounting P.1312

With Timer Band, Rail, Tie-rod, Direct Mounting P.1313

Magnetic Field Resistant 2-Color Indication Type Rail, Tie-rod, Direct Mounting P.1317

Heat Resistant 2-Color Indication Type Rail Mounting P.1319

Wide Range Detection Type Band Mounting P.1320

Trimmer Auto Switch Rail, Direct Mounting P.1321

Made to Order Specifications P.1328

Reed Auto Switches P.1331


General Purpose Type Band, Rail, Tie-rod, Direct Mounting P.1332

2-Color Indication Type Band, Rail, Tie-rod Mounting P.1345

Magnetic Field Resistant 2-Color Indication Type Rod Mounting P.1348

Heat Resistant Band Mounting P.1351


D-쏔

• Data ································································································· P.1355

1275
P1263-P1276-E.qxd 08.10.6 3:17 PM Page 1276

1276
Solid State Auto Switches
General Purpose Type, 2-Color Indication Type, 2-Color
Indication Type with Diagnostic Output, Water Resistant 2-Color
Indication Type, Hygienic Type, Timer Equipped Type, Magnetic
Field Resistant Type, Heat Resistant Type, Wide Range
Detection Type, Trimmer Auto Switch
Auto switch
Type Function mounting style Electrical entry Auto switch model Page

D-H7A1/H7A2/H7B 1278
Grommet
D-G59/G5P/K59 1279
Band Connector D-H7C 1280
Terminal D-G39/K39 1281
conduit D-G39A/K39A 1282
D-F79/F7P/J79 1283
General purpose

Grommet
Rail D-F7NV/F7PV/F7BV 1284
Connector D-J79C 1285
Grommet D-F59/F5P/J59/J51 1286
Tie-rod
Terminal conduit D-G39C/K39C 1287
D-M9N/M9P/M9B
1288
D-M9NV/M9PV/M9BV
D-F8N/F8P/F8B 1289
D-F9G/F9H (Normally closed) 1290
Direct Grommet
D-Y59A/Y59B/Y7P
1291
D-Y69A/Y69B/Y7PV
D-Y7G/Y7H (Normally closed) 1292
D-M5N/M5P/M5B 1293

D-H7NW/H7PW/H7BW 1294
Band Grommet
D-G59W/G5PW/K59W 1295
2-color indication

D-F79W/F7PW/J79W 1296
Rail Grommet
Solid State Auto Switch

D-F7NWV/F7BWV 1297
Tie-rod Grommet D-F59W/F5PW/J59W 1298
D-M9NW/M9PW/M9BW
1299
D-M9NWV/M9PWV/M9BWV
Direct Grommet D-Y7NW/Y7PW/Y7BW
1300
D-Y7NWV/Y7PWV/Y7BWV
D-M5NW/M5PW/M5BW 1301

2-color Band Grommet


D-H7NF 1302
indication D-G59F 1303
with
diagnostic Rail Grommet D-F79F 1304
output Tie-rod Grommet D-F59F 1305

D-H7BAL 1306
2-color indication

Band Grommet
Water resistant

D-G5BAL 1307
D-F7BAL
Rail Grommet 1308
D-F7BAVL
Tie-rod Grommet D-F5BAL 1309
D-M9PA/M9NA/M9BA
Direct Grommet 1310
D-M9PAV/M9NAV/M9BAV
D-Y7BAL 1311

Hygienic Direct Grommet D-F6N/F6P/F6B 1312

Band Grommet D-G5NTL 1313


With timer

Rail Grommet D-F7NTL 1314


Tie-rod Grommet D-F5NTL 1315
Direct Grommet D-M5NTL/M5PTL 1316

D-P3DWSC/P3DWSE 1317-1
Rail, Tie-rod, Direct Grommet
Magnetic field D-P3DW 1317-2
resistance D-P4DWSC/P4DWSE 1317-3
Rail Grommet
D-P4DWL 1318
D-쏔
Sensor section: Rail D-F7NJL
Heat resistant Amplifier section: DIN rail
Grommet 1319

Wide range Band Grommet D-G5NBL 1320


detection
Trimmer Rail
Grommet D-F7K/Y7K 1321
Auto Switch Direct

1277 C
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1278

Solid State Auto Switch


Band Mounting Style
D-H7A1/D-H7A2/D-H7B
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-H7 (With indicator light)
Auto switch model D-H7A1 D-H7A2 D-H7B
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 2 cores
(Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit


D-H7A1
DC (+) Mass (g)
Brown
Main circuit
of switch

OUT Auto switch model D-H7A1 D-H7A2 D-H7B


Black
0.5 13 13 11
Lead wire length
(m) 3 57 57 50
DC (–) 5 92 92 81
Blue

D-H7A2

DC (+)
Dimensions (mm)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-H7B
OUT (+) Indicator light
Brown
ø3.5 mounting hole
Main circuit
of switch

OUT (–)
Blue

Most sensitive position

1278
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1279

Solid State Auto Switch


Band Mounting Style
D-G59/D-G5P/D-K59
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-G5, D-K59 (With indicator light)
Auto switch model D-G59 D-G5P D-K59
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit


D-G59
DC (+) Mass (g)
Brown
Main circuit
of switch

OUT Auto switch model D-G59 D-G5P D-K59


Black
0.5 20 20 18
Lead wire length
(m) 3 78 78 68
DC (–) 5 124 124 108
Blue

D-G5P
DC (+) Dimensions (mm)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-K59
Indicator light
OUT (+)
Brown
ø4.5 mounting hole
Main circuit
of switch

OUT (–)
Blue
Most sensitive position D-

1279
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1280

Solid State Auto Switch


Band Mounting Style
D-H7C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Connector PLC: Programmable Logic Controller


D-H7C (With indicator light)
Auto switch model D-H7C
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Caution Standard CE marking
Precautions • Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
1. Confirm that the connector is appropriately
Note 2) Refer to page 1272 for lead wire lengths.
tightened. If tightened insufficiently, the
Note 3) Lead wires with a connector may be shipped with switches.
waterproof performance will deteriorate.
2. Refer to page 1355 for the details.

Auto Switch Internal Circuit


D-H7C Mass (g)

OUT (+) Auto switch model D-H7C


Brown
0.5 15
Lead wire length
Main circuit
of switch

(m) 3 54
5 85

OUT (–)
Blue

Dimensions (mm)

Indicator light

ø3.5 mounting hole

Most sensitive position

1280
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1281

Solid State Auto Switch


Band Mounting Style
D-G39/D-K39
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit PLC: Programmable Logic Controller


D-G39, D-K39 (With indicator light)
Auto switch model D-G39 D-K39
Wiring type 3-wire 2-wire
Output type NPN —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA of load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Caution Indicator light Red LED illuminates when turned ON.
Precautions Standard CE marking
1. Use cable whose O.D. is within the size in Note) Refer to page 1272 for solid state auto switch common specifications.
the figure to maintain water resistant
performance.
2. After wiring, confirm that tightening gland
and all screws are tightened.

Auto Switch Internal Circuit Mass (g)

D-G39
Auto switch model D-G39 D-K39
DC (+)
Terminal no. 1 Lead wire None 116 116
Main circuit
of switch

OUT
Terminal no. 2

DC (–)
Terminal no. 3
Dimensions (mm)

D-K39
Tightening gland
OUT (+)
Terminal no. 1
Main circuit
of switch

G (PF) 1/2
(Applicable cable O.D.
ø6.8 to ø9.6)
OUT (–)
Terminal no. 2

Indicator light
Most sensitive position

D-

1281
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1282

Solid State Auto Switch


Band Mounting Style
D-G39A/D-K39A
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit PLC: Programmable Logic Controller


D-G39A, D-K39A (With indicator light)
Auto switch model D-G39A D-K39A
Wiring type 3-wire 2-wire
Output type NPN —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA of load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Caution Indicator light Red LED illuminates when turned ON.
Precautions Standard CE marking
1. Use cable whose O.D. is within the size in Note) Refer to page 1272 for solid state auto switch common specifications.
the figure to maintain water resistant
performance.
2. After wiring, confirm that tightening gland
and all screws are tightened.

Auto Switch Internal Circuit Mass (g)

D-G39A
DC (+)
Auto switch model D-G39A D-K39A
Terminal no. 1 Lead wire None 110 110
Main circuit
of switch

OUT
Terminal no. 2

DC (–)
Terminal no. 3
Dimensions (mm)

D-K39A G (PF) 1/2


OUT (+) (Applicable cable O.D.
Terminal no. 1 ø6.8 to ø9.6)
Main circuit
of switch

Tightening gland

OUT (–)
Terminal no. 2

Indicator light Most sensitive position

1282
P1277-P1354-E.qxd 08.10.3 2:42 PM Page 1283

Solid State Auto Switch


Rail Mounting Style
D-F79/D-F7P/D-J79
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F7, D-J79 (With indicator light)
Auto switch model D-F79 D-F7P D-J79
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-F79
Auto switch model D-F79 D-F7P D-J79
DC (+)
Brown 0.5 13 13 11
Lead wire length
3 57 57 50
Main circuit

(m)
of switch

OUT
Black
5 92 92 81

DC (–)
Blue
Dimensions (mm)

D-F7P
ø3.2 mounting hole
DC (+)
Indicator light
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-J79
OUT (+)
Brown
Most sensitive position
Main circuit
of switch

D-
OUT (–)
Blue

1283
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1284

Solid State Auto Switch


Rail Mounting Style
D-F7NV/D-F7PV/D-F7BV
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


Electrical entry: Perpendicular D-F7V (With indicator light)
Auto switch model D-F7NV D-F7PV D-F7BV
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-F7NV
Auto switch model D-F7NV D-F7PV D-F7BV
DC (+)
Brown 0.5 13 13 11
Lead wire length
3 57 57 50
(m)
Main circuit
of switch

OUT 5 92 92 81
Black

DC (–)
Blue
Dimensions (mm)

D-F7PV ø3.2 mounting hole


Indicator light
DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue

D-F7BV
OUT (+)
Brown Most sensitive position
Main circuit
of switch

OUT (–)
Blue

1284
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1285

Solid State Auto Switch


Rail Mounting Style
D-J79C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Connector PLC: Programmable Logic Controller


D-J79C (With indicator light)
Auto switch model D-J79C
Wiring type 2-wire
Output type —
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
Caution • Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Precautions Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
1. Confirm that the connector is appropriately
Note 3) Lead wires with a connector may be shipped with auto switches.
tightened. If tightened insufficiently, the
waterproof performance will deteriorate.
2. Refer to page 1355 for the details.

Mass (g)
Auto Switch Internal Circuit
D-J79C Auto switch model D-J79C
0.5 13
OUT (+) Lead wire length
Brown 3 52
(m)
5 83
Main circuit
of switch

OUT (–) Dimensions (mm)


Blue

ø3.2 mounting hole

Indicator light

Most sensitive position D-

1285
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1286

Solid State Auto Switch


Tie-rod Mounting Style
D-F59/D-F5P/D-J59/D-J51 Refer to SMC website for the details of
the products conforming to the
international standards.
Auto Switch Specifications (Except D-J51)

Grommet PLC: Programmable Logic Controller


D-F5, D-J5 (With indicator light)
Auto switch model D-F59 D-F5P D-J59 D-J51
Wiring type 3-wire 2-wire
Output type NPN PNP — —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC AC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — —
Current consumption 10 mA or less — —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) 80 to 260 VAC
Load current 40 mA or less 80 mA or less 5 to 40 mA 5 to 80 mA
Auto Switch Internal Circuit 1.5 V or less
Internal voltage drop (0.8 V or less at 0.8 V or less 4 V or less 14 V or less
10 mA load current)
D-F59
0.8 mA or less 1 mA or less at 100 VAC
Leakage current 100 μA or less at 24 VDC
DC (+) at 24 VDC 1.5 mA or less at 200 VAC
Brown
Indicator light Red LED illuminates when turned ON.
Main circuit
of switch

OUT Standard CE marking —


Black
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
DC (–) Note 2) Refer to page 1272 for lead wire lengths.
Blue
Mass (g)

D-F5P
Auto switch model D-F59 D-F5P D-J59 D-J51
DC (+) 23 23 21 21
0.5
Brown
Lead wire length
3 81 81 71 71
(m)
Main circuit
of switch

5 127 127 111 111


OUT
Black Dimensions (mm)
DC (–) D-F59/D-F5P/D-J59
Blue
Mounting hole

D-J59
Indicator light
OUT (+)
Brown
Main circuit
of switch

OUT (–)
Blue

Most sensitive position


D-J51
D-J51
6 14
Main circuit
of switch

6
4.5

OUT (~)
Brown
ø4
12 5
22

OUT (~)
Blue

7
Indicator light 33 12

ø7
1.4

D-J51
16
11

10 Most sensitive position

1286
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1287

Solid State Auto Switch


Tie-rod Mounting Style
D-G39C/D-K39C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit PLC: Programmable Logic Controller


D-G39C, D-K39C (With indicator light)
Auto switch model D-G39C D-K39C
Wiring type 3-wire 2-wire
Output type NPN —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA of load current)
Caution Current leakage 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Precautions
Standard CE marking
1. Use cable whose O.D. is within the size in
the figure to maintain water resistant Note) Refer to page 1272 for solid state auto switch common specifications.
performance.
2. After wiring, confirm that tightening gland Mass (g)
and all screws are tightened.
Auto switch model D-G39C D-K39C
40 162 162
50 166 166
Auto Switch Internal Circuit Applicable bore size
63 184 184
(mm)
D-G39C 80 210 210
100 232 232
DC (+)
Terminal no. 1
Dimensions (mm)
Main circuit
of switch

OUT
Terminal no. 2
2 x M5 x 0.8 x 12
Hexagon socket head cap bolt
DC (–)
Terminal no. 3

D-K39C
Tightening gland
OUT (+) 4xZ
Terminal no. 1 Hexagon socket
head cap bolt
Main circuit
of switch

G (PF) 1/2
(Applicable cable O.D.
ø6.8 to ø9.6)

OUT (–)
Terminal no. 2

Indicator light
Most sensitive position

Dimensions
Applicable bore D-
Auto switch model
size (mm) C HW H H´ T T´ Z
D-G39C-4, D-K39C-4 40 44 69 57 49.5 7.5 6.5
50 M5 x 0.8 x 16
D-G39C-5, D-K39C-5 52 77 58 50.5 8.5 6.5
D-G39C-6, D-K39C-6 63 64 91 60.5 52 10.5 7.5 M5 x 0.8 x 20
D-G39C-8, D-K39C-8 80 78 107 64 53.5 12.5 9.5
100 M5 x 0.8 x 25
D-G39C-10, D-K39C-10 92 121 67 56.5 15.5 9.5

1287
2-others.qxd 09.10.1 2:01 PM Page 2

Solid State Auto Switch


Direct Mounting Style
D-M9N(V)/D-M9P(V)/D-M9B(V)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

 2-wire load current is reduced (2.5 to D-M9, D-M9V (With indicator light)
40 mA). Auto switch model D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV
 Flexibility is 1.5 times greater than Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
the conventional model (SMC Wiring type 3-wire 2-wire
comparison). Output type NPN PNP —
 Using flexible cable as standard spec.
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
(D-M9B(V)), 3 cores (D-M9N(V), D-M9P(V))
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass
(g)

Auto switch model D-M9N(V) D-M9P(V) D-M9B(V)


Caution 0.5 8 8 7
Precautions Lead wire length 1 14 14 13
Fix the auto switch with the existing screw (m) 3 41 41 38
installed on the auto switch body. The auto 5 68 68 63
switch may be damaged if a screw other
than the one supplied is used. Dimensions (mm)

D-M9
M2.5 x 4 L
Auto Switch Internal Circuit
Slotted set screw
D-M9N, D-M9NV Indicator light
DC (+)
2.6
Brown
Main circuit
of switch

2.7

OUT
2.8
4

Black
22
3.2

DC (–)
Blue

6 Most sensitive position


D-M9P, D-M9PV
DC (+)
Brown D-M9V
Main circuit
of switch

M2.5 x 4 L Indicator light


OUT
Black Slotted set screw 8
2 3.2
4.6

DC (–)
Blue
4
2.8

D-M9B, D-M9BV 20
2.7
OUT (+)
Brown
Main circuit
of switch

2.6
9.5

OUT (–)
Blue 6 Most sensitive position

1288
2-2-47-D-UMASw.qxd 09.9.30 3:22 PM Page 2

Solid State Auto Switch


Direct Mounting Style
D-F8N/D-F8P/D-F8B
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F8쏔 (With indicator light)
Auto switch model D-F8N D-F8P D-F8B
Electrical entry direction Perpendicular Perpendicular Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, 24 VDC Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 2.5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Caution Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Precautions Indicator light Red LED illuminates when turned ON.
Fix the auto switch with the existing screw
Standard CE marking
installed on the auto switch body. The auto
switch may be damaged if a screw other • Lead wires — Oilproof heavy-duty vinyl cord, ø2.7
than the one supplied is used. D-F8N, D-F8P 0.15 mm2 x 3 cores (Brown, Black, Blue)
D-F8B 0.18 mm2 x 2 cores (Brown, Blue)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit


D-F8N Mass (g)

DC (+)
Brown Auto switch model D-F8N D-F8P D-F8B
Main circuit

0.5 7 7 7
of switch

OUT Lead wire length


Black 3 32 32 32
(m)
5 52 52 52

DC (–)
Blue

Dimensions (mm)
D-F8P D-F8N/D-F8P/D-F8B
DC (+) M2.5 x 4 L
Brown
Slotted set screw
4.3
Main circuit
of switch

Indicator light
2
OUT
Black

DC (–) 10
2.8

ø2.7
4.6

Blue

D-F8B
OUT (+)
Brown
3
Main circuit

10.9
of switch

4
3.1

8 Most sensitive position


OUT (–)
Blue
D-쏔

1289
2-others.qxd 09.10.1 2:01 PM Page 3

Normally Closed Solid State Auto Switch


Direct Mounting Style
D-F9G/D-F9H
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

Output signal turns on when no D-F9G, D-F9H (With indicator light)


magnetic force is detected. Auto switch model D-F9G D-F9H
Wiring type 3-wire
Output type NPN PNP
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less —
Load current 40 mA or less 80 mA or less
1.5 V or less
Internal voltage drop 0.8 V or less
Caution (0.8 V or less at 10 mA load current)
Precautions Leakage current 100 µA or less at 24 VDC
Fix the auto switch with the existing screw Indicator light Red LED illuminates when detecting nothing.
installed on the auto switch body. The auto Standard CE marking
switch may be damaged if a screw other
• Lead wires — Oilproof heavy-duty vinyl cord, ø2.7, 0.15 mm2, 3 cores (Brown, Black, Blue) 0.5 m
than the one supplied is used. Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-F9G
Auto switch model D-F9G D-F9H
DC (+)
Brown 0.5 7 7
Lead wire length
3 37 37
Main circuit

(m)
of switch

OUT 5 61 61
Black

DC (–)
Blue
Dimensions (mm)

D-F9H
DC (+) M2.5 x 4 L
Brown Slotted set screw
Main circuit
of switch

2 Indicator light

OUT
Black
NC

SMC D-F9H

DC (–) 22
ø2.7
2.8

Blue
2.6

6 Most sensitive position

1290
2-2-47-D-UMASw.qxd 09.9.30 3:22 PM Page 3

Solid State Auto Switch


Direct Mounting Style
D-Y59 AB /D-Y69 AB /D-Y7P(V)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

Using flexible cable as standard D-Y5쏔, D-Y6쏔, D-Y7P, D-Y7PV (With indicator light)
spec. Auto switch model D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 2.5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof flexible heavy-duty vinyl cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black,
Blue), 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Auto Switch Internal Circuit
D-Y59A, D-Y69A
DC (+)
Mass (g)
Brown
Main circuit

Auto switch model D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V)


of switch

OUT
Black 0.5 9 10 10
Lead wire length
3 50 53 53
(m)
5 83 87 87
DC (–)
Blue

D-Y7P, D-Y7PV
Dimensions (mm)
DC (+)
Brown D-Y59A/D-Y7P/D-Y59B D-Y69A/D-Y7PV/D-Y69B
Main circuit
of switch

M2.5 x 4 L
OUT M2.5 x 4 L Slotted set screw
Black
Slotted set screw Indicator light
2.5
DC (–) Indicator light
Blue
2.5
SMC
6.2
SMC
6.2

D-Y59B, D-Y69B 27.3


ø3.4

29
OUT (+) ø3.4
Brown
Main circuit
of switch

8.5
5

12.5 Most sensitive position


12.5 Most sensitive position

OUT (–)
Blue
D-쏔

1291
2-others.qxd 09.10.1 2:01 PM Page 4

Normally Closed Solid State Auto Switch


Direct Mounting Style
D-Y7G/D-Y7H
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

 Output signal turns on when D-Y7G, D-Y7H (With indicator light)


no magnetic force is detected. Auto switch model D-Y7G D-Y7H
 Using flexible cable as Wiring type 3-wire

standard spec. Output type NPN PNP


Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less —
Load current 40 mA or less 80 mA or less
1.5 V or less
Internal voltage drop 0.8 V or less
(0.8 V or less at 10 mA load current)
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when detecting nothing.
Standard CE marking
• Lead wires — Oilproof flexible heavy-duty vinyl cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue),
0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-Y7G
DC (+) Auto switch model D-Y7G D-Y7H
Brown 0.5 10 10
Lead wire length
Main circuit

3 53 53
of switch

OUT (m)
Black 5 87 87

DC (–)
Blue
Dimensions (mm)

D-Y7H
M2.5 x 4 L
DC (+)
Slotted set screw
Brown
Indicator light
Main circuit

ø3.4
of switch

2.5

OUT
SMC

Black
6.2

NC
DC (–)
Blue 29
5

D-Y7G

12.5 Most sensitive position

1292
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1293

Solid State Auto Switch


Direct Mounting Style
D-M5N/D-M5P/D-M5B
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-M5 (With indicator light)
Auto switch model D-M5N D-M5P D-M5B
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 μA or less at 24 VDC 0.8 mA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-M5N
Auto switch model D-M5N D-M5P D-M5B
DC (+)
Brown 0.5 16 16 14
Lead wire length
3 60 60 53
Main circuit

(m)
of switch

OUT 5 95 95 84
Black

DC (–)
Blue
Dimensions (mm)

D-M5P
Indicator light
DC (+)
Brown
Main circuit
of switch

OUT
Black

DC (–)
Blue
ø3 mounting hole

D-M5B
OUT (+)
Brown
Main circuit
of switch

Most sensitive position

D-
OUT (–)
Blue

1293
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 1

2-Color Indication Type Solid State Auto Switch


Band Mounting Style
D-H7NW/D-H7PW/D-H7BW
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-H7쏔W (With indicator light)


be determined by the color of Auto switch model D-H7NW D-H7PW D-H7BW
the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
Auto Switch Internal Circuit
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
D-H7NW 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
DC (+)
Brown
Main circuit

OUT
of switch

Black
Mass (g)

DC (–)
Blue Auto switch model D-H7NW D-H7PW D-H7BW
0.5 13 13 11
Lead wire length
3 57 57 50
D-H7PW (m)
5 92 92 81
DC (+)
Brown
Main circuit
of switch

OUT
Black Dimensions (mm)

DC (–)
Blue 4.6

29
D-H7BW
9
OUT (+)
ø3.4

Brown
Main circuit
of switch

6.5
8

Indicator light
OUT (–)
Blue
4.3 ø3.5
mounting hole

Indicator light/Display method


11.5

Operating range

Indication Most sensitive


Red Green Red 10.5 position

Proper operating range

1294
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 2

2-Color Indication Type Solid State Auto Switch


Band Mounting Style
D-G59W/D-G5PW/D-K59W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-G5쏔W, D-K59W (With indicator light)
be determined by the color of Auto switch model D-G59W D-G5PW D-K59W
the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
Auto Switch Internal Circuit
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
D-G59W 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
DC (+)
Brown
Main circuit

OUT
of switch

Black
Mass (g)

DC (–)
Blue Auto switch model D-G59W D-G5PW D-K59W
0.5 20 20 18
Lead wire length
3 78 78 68
D-G5PW (m)
5 124 124 108
DC (+)
Brown
Main circuit
of switch

OUT
Black Dimensions (mm)

DC (–)
Blue

D-K59W

OUT (+)
Brown
Main circuit
of switch

Indicator light

ø4.5 mounting hole

OUT (–)
Blue

Indicator light/Display method

Most sensitive position


Operating range
D-쏔
Indication
Red Green Red

Proper operating range

1295
2-2-47-D-UMASw.qxd 10.3.30 1:07 PM Page 1

2-Color Indication Type Solid State Auto Switch


Rail Mounting Style
D-F79W/D-F7PW/D-J79W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-F7쏔W, D-J79W (With indicator light)
be determined by the color of Auto switch model D-F79W D-F7PW D-J79W
the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Standard CE marking
Auto Switch Internal Circuit
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
D-F79W 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
DC (+) Note 2) Refer to page 1272 for lead wire lengths.
Brown
Main circuit
of switch

OUT
Black
Mass (g)

DC (–) Auto switch model D-F79W D-F7PW D-J79W


Blue
0.5 13 13 11
Lead wire length
3 57 57 50
D-F7PW (m)
5 92 92 81
DC (+)
Brown
Main circuit
of switch

OUT
Black Dimensions (mm)

DC (–)
Blue ø3.2 mounting hole
8
Indicator light
D-J79W
15

OUT (+)
Brown
Main circuit

23
of switch

4.6
ø3.4

3.2

OUT (–)
Blue
11

6.2

Indicator light/Display method 8.5 Most sensitive position

Operating range

Indication
Red Green Red

Proper operating range

1296
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 4

2-Color Indication Type Solid State Auto Switch


Rail Mounting Style
D-F7NWV/D-F7BWV
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


Electrical entry: Perpendicular D-F7쏔WV (With indicator light)
The proper operating range can Auto switch model D-F7NWV D-F7BWV
be determined by the color of Wiring type 3-wire 2-wire
the light. Output type NPN —
(Red → Green ← Red) Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC)
Load current 40 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Auto Switch Internal Circuit Mass (g)

D-F7NWV
Auto switch model D-F7NWV D-F7BWV
DC (+) 0.5 13 11
Brown
Lead wire length
3 57 50
Main circuit

OUT
of switch

(m)
Black
5 92 81

DC (–)
Blue

Dimensions (mm)

D-F7BWV
ø3.2 mounting hole
OUT (+)
Brown Indicator light
Main circuit
of switch

OUT (–)
Blue

Indicator light/Display method

Operating range

Indication
Red Green Red
Most sensitive position D-쏔
Proper operating range

1297
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 5

2-Color Indication Type Solid State Auto Switch


Tie-rod Mounting Style
D-F59W/D-F5PW/D-J59W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-F5쏔W, D-J59W (With indicator light)
be determined by the color of Auto switch model D-F59W D-F5PW D-J59W
the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
Auto Switch Internal Circuit
• Lead wires –– Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue),
D-F59W 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
DC (+)
Brown
Main circuit

OUT
of switch

Black

Mass (g)

DC (–)
Blue Auto switch model D-F59W D-F5PW D-J59W
0.5 23 23 21
Lead wire length
3 81 81 71
D-F5PW (m)
5 127 127 111
DC (+)
Brown
Main circuit
of switch

OUT
Black Dimensions (mm)

DC (–)
Blue
Mounting hole

D-J59W
Indicator light
OUT (+)
Brown
Main circuit
of switch

OUT (–)
Blue

Indicator light/Display method

Operating range
Most sensitive position
Indication
Red Green Red

Proper operating range

1298
RoHS-SW-2.qxd 10.7.26 5:16 PM Page 1

2-Color Indication Type Solid State Auto Switch


Direct Mounting Style
D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


쎲 2-wire load current is reduced (2.5 to D-M9쏔W, D-M9쏔WV (With indicator light)
40 mA). Auto switch model D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV
쎲 Flexibility is 1.5 times greater than the Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
conventional model (SMC comparison). Wiring type 3-wire 2-wire
쎲 Using flexible cable as standard spec.
쎲 The proper operating range can be Output type NPN PNP —
determined by the color of the light. Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
(Red → Green ← Red) Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
Caution 쎲Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
(D-M9BW(V)), 3 cores (D-M9NW(V), D-M9PW(V))
Precautions Note 1) Refer to page 1272 for solid state auto switch common specifications.
Fix the auto switch with the existing screw Note 2) Refer to page 1272 for lead wire lengths.
installed on the auto switch body. The auto
switch may be damaged if a screw other
than the one supplied is used. Mass (g)

Auto Switch Internal Circuit Auto switch model D-M9NW(V) D-M9PW(V) D-M9BW(V)
0.5 8 8 7
D-M9NW, D-M9NWV
Lead wire length 1 14 14 13
DC (+) (m) 3 41 41 38
Brown
5 68 68 63
Main circuit
of switch

OUT
Black

Dimensions (mm)

DC (–) D-M9쏔W M2.5 x 4 L


Blue
Slotted set screw

D-M9PW, D-M9PWV Indicator light


2.6
DC (+)
Brown
Main circuit
of switch

2.7
2.8
4

OUT
Black
22
3.2

DC (–)
Blue

6 Most sensitive position


D-M9BW, D-M9BWV
D-M9쏔WV
OUT (+) Indicator light
Brown
M2.5 x 4 L
Main circuit
of switch

Slotted set screw


8
2 3.2
4.6

OUT (–)
4

Blue
2.8

Indicator light / Display method 20 2.7


ON D-쏔
Operating range OFF
2.6

Display
9.5

Red Green Red


4

Proper operating range 6 Most sensitive position

1299
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 7

2-Color Indication Type Solid State Auto Switch


Direct Mounting Style
D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

쎲 The proper operating range can be D-Y7쏔W, D-Y7쏔WV (With indicator light)
determined by the color of the Auto switch model D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV
light. (Red → Green ← Red)
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
쎲 Using flexible cable as standard
spec. Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 2.5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Auto Switch Internal Circuit Operating range .......... Red LED illuminates.
Indicator light Proper operating range .......... Green LED illuminates.
D-Y7NW, Y7NWV
Standard CE marking
DC (+) • Lead wires — Oilproof flexible heavy-duty vinyl cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue),
Brown 2 cores (Brown, Blue), 0.5 m
Main circuit

OUT Note 1) Refer to page 1272 for solid state auto switch common specifications.
of switch

Black Note 2) Refer to page 1272 for lead wire lengths.

DC (–)
Mass (g)
Blue

Auto switch model D-Y7NW(V) D-Y7PW(V) D-Y7BW(V)


0.5 11 11 11
D-Y7PW, Y7PWV Lead wire length
3 54 54 54
(m)
DC (+) 5 88 88 88
Brown
Main circuit

Dimensions
of switch

(mm)
OUT
Black
D-Y7쏔W M2.5 x 4 L
Slotted set screw
DC (–)
Blue Indicator light
ø3.4

2.5
SMC
6.2

D-Y7BW, Y7BWV
29
OUT (+)
Brown
Main circuit
of switch

12.5 Most sensitive position

OUT (–)
Blue
D-Y7쏔WV
M2.5 x 4 L
Slotted set screw
Indicator light/Display method Indicator light
2.5
SMC
6.2

Operating range

27.3
Indication
Red Green Red
ø3.4

Proper operating range


8.5
5

12.5 Most sensitive position

1300
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 8

2-Color Indication Type Solid State Auto Switch


Direct Mounting Style
D-M5NW/D-M5PW/D-M5BW
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-M5쏔W (With indicator light)


be determined by the color of Auto switch model D-M5NW D-M5PW D-M5BW
the light. Wiring type 3-wire 2-wire
(Red → Green ← Red) Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 80 mA or less 5 to 40 mA
1.5 V or less
Internal voltage drop (0.8 V or less 0.8 V or less 4 V or less
at 10 mA load current)
Leakage current 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Auto Switch Internal Circuit Proper operating range .......... Green LED illuminates.
Standard CE marking
D-M5NW
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue) 0.5 m
DC (+) Note 1) Refer to page 1272 for solid state auto switch common specifications.
Brown Note 2) Refer to page 1272 for lead wire lengths.
Main circuit

OUT
of switch

Black
Mass (g)

DC (–)
Blue Auto switch model D-M5NW D-M5PW D-M5BW
0.5 16 16 14
Lead wire length
3 60 60 53
D-M5PW (m)
5 95 95 84
DC (+)
Brown
Main circuit
of switch

OUT
Black
Dimensions (mm)

DC (–)
Blue
Indicator light

D-M5BW

OUT (+)
Brown
Main circuit
of switch

OUT (–) ø3 mounting hole


Blue

Indicator light/Display method

Operating range
Most sensitive position
Indication
D-쏔
Red Green Red

Proper operating range

1301
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 9

2-Color Indication Type with Diagnostic Output


Solid State Auto Switch: Band Mounting Style
D-H7NF
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-H7NF (With indicator light)
Since the diagnostic output
Auto switch model D-H7NF
signal can be detected in an
Wiring type 4-wire
unsteady detecting area, the
Output type NPN
difference of detecting position
Diagnostic output Normal operation
can be confirmed by the side of
Applicable load IC circuit, Relay, PLC
PLC (Programmable Logic
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Controller).
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at each output 5 mA)
Current leakage 100 µA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light Proper operating range .......... Green LED illuminates.

Auto Switch Internal Circuit Standard CE marking


• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue),
0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
DC (+) Note 2) Refer to page 1272 for lead wire lengths.
Brown
OUT (Normal output)
Black
Mass (g)
Main circuit
of switch

Diagnosis OUT
(Diagnostic output) Auto switch model D-H7NF
Orange
0.5 13
Lead wire length
DC (–) (m) 3 56
Blue
5 90

Diagnostic Output Operation


The diagnostic output signal is ON
output within unsteady
OFF Red Green Red OFF Red
detecting area (where Indicator light
indicator light is Red), and the
diagnostic output becomes
OFF when the detecting OUT
(Normal output)
position remains within the
proper operating range
(where indicator is Green). Diagnosis OUT
When the detecting position is (Diagnostic output)
not adjusted, the diagnostic
output becomes ON.

Dimensions (mm)
ø3.4

Indicator light

ø3.5 mounting hole

Most sensitive
position

1302
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 10

2-Color Indication Type with Diagnostic Output


Solid State Auto Switch: Band Mounting Style
D-G59F
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-G59F (With indicator light)
Since the diagnostic output
Auto switch model D-G59F
signal can be detected in an
Wiring type 4-wire
unsteady detecting area, the
Output type NPN
difference of detecting position
Diagnostic output Normal operation
can be confirmed by the side of
Applicable load IC circuit, Relay, PLC
PLC (Programmable Logic
Power voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Controller).
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA)
Current leakage 100 µA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
Auto Switch Internal Circuit
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue),
0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
DC (+)
Brown
OUT (Normal output) Mass (g)
Black
Main circuit
of switch

Diagnosis OUT
(Diagnostic output) Auto switch model D-G59F
Orange
0.5 20
Lead wire length
DC (–) (m) 3 74
Blue
5 117

Diagnostic Output Operation


The diagnostic output signal
ON
is output within unsteady
detecting area (where OFF Red Green Red OFF Red
Indicator light
indicator light is Red), and the
diagnostic output becomes
OFF when the detecting OUT
position remains within the (Normal output)
proper operating range
(where indicator is Green).
When the detecting position is Diagnosis OUT
(Diagnostic output)
not adjusted, the diagnostic
output becomes ON.

Dimensions (mm)
ø4

Indicator light

ø4.5 mounting hole D-쏔

Most sensitive position

1303
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 11

2-Color Indication Type with Diagnostic Output


Solid State Auto Switch: Rail Mounting Style
D-F79F
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F79F (With indicator light)
Since the diagnostic output
Auto switch model D-F79F
signal can be detected in an
Wiring type 4-wire
unsteady detecting area, the
Output type NPN
difference of detecting position
Diagnostic output Normal operation
can be confirmed by the side of
Applicable load IC circuit, Relay, PLC
PLC (Programmable Logic
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Controller).
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA)
Leakage current 100 µA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
쎲Lead wires — Oilproof heavy-duty vinyl cord: ø3.4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue), 0.5 m
Auto Switch Internal Circuit Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

DC (+)
Brown
Mass (g)

OUT (Normal output)


Black
Auto switch model D-F79F
Main circuit
of switch

Diagnosis OUT 0.5 13


(Diagnostic output)
Orange
Lead wire length
3 56
(m)
5 90
DC (–)
Blue

Diagnostic Output Operation


The diagnostic output signal is
output within an unsteady de- Indicator Red Green Red Red
tecting area (where indicator light
light is Red), and it is not out-
put within the proper operating
OUT
range (where indicator light is (Normal output)
Green). When the auto switch
detecting position is not adjus- Diagnosis
ted, the diagnostic output be- OUT
comes activated. (Diagnostic output)

Dimensions (mm)

ø3.2 Mounting hole


Indicator light
ø3.4

Most sensitive position

1304
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 12

2-Color Indication Type with Diagnostic Output


Solid State Auto Switch: Tie-rod Mounting Style
D-F59F
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F59F (With indicator light)
Since the diagnostic output signal Auto switch model D-F59F
can be detected in an unsteady
Wiring type 4-wire
detecting area, the difference of
Output type NPN
detecting position can be
Diagnostic output Normal operation
confirmed by the side of PLC
Applicable load IC circuit, Relay, PLC
(Programmable Logic Controller).
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 50 mA or less at the total amount of normal output and diagnostic output
Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA)
Leakage current 100 µA or less at 28 VDC

Indicator light Operating range .......... Red LED illuminates.


Proper operating range .......... Green LED illuminates.

Auto Switch Internal Circuit Standard CE marking


• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue), 0.5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
DC (+)
Brown
OUT (Normal output)
Black Mass (g)
Main circuit
of switch

Diagnosis OUT
(Diagnostic output)
Orange Auto switch model D-F59F
0.5 22
DC (–) Lead wire length
3 77
Blue (m)
5 121

Diagnostic Output Operation


The diagnostic output signal is
output within an unsteady de- Indicator OFF Red Green Red OFF Red
tecting area (where indicator light
light is Red), and it is not out-
put within the proper operating
OUT
range (where indicator light is (Normal output)
Green). When the auto switch
detecting position is not adjus- Diagnosis
ted, the diagnostic output be- OUT
comes activated. (Diagnostic output)

Dimensions (mm)

Mounting hole

Indicator light
ø4

D-쏔

Most sensitive position

1305
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 13

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Band Mounting Style
D-H7BAL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-H7BAL (With indicator light)
쎲 Water (coolant) resistant type
Auto switch model D-H7BAL
쎲 The proper operating range
Wiring type 2-wire
can be determined by the
color of the light. Output type —
(Red → Green ← Red) Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC

Caution Operating range .......... Red LED illuminates.


Indicator light
Proper operating range .......... Green LED illuminates.
Precautions
Standard CE marking
Please consult with SMC if using coolant • Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard)
liquid other than water based solution. Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-H7BA


0.5 —
Lead wire length
3 50
(m)
Auto Switch Internal Circuit 5 81

OUT (+)
Brown
Dimensions
Main circuit

(mm)
of switch

OUT (–)
Blue
ø3.4

Indicator light/Display method


Indicator light

ø3.5 mounting hole


Operating range

Indication
Red Green Red

Proper operating range Most sensitive position

1306
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 14

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Band Mounting Style
D-G5BAL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-G5BAL (With indicator light)
쎲 Water (coolant) resistant type
Auto switch model D-G5BAL
쎲 The proper operating range
Wiring type 2-wire
can be determined by the
color of the light. Output type —
(Red → Green ← Red) Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC

Caution Operating range .......... Red LED illuminates.


Indicator light
Proper operating range .......... Green LED illuminates.
Precautions
Standard CE marking
Please consult with SMC if using coolant • Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard)
liquid other than water based solution. Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-G5BA


0.5 —
Lead wire length
3 68
(m)
Auto Switch Internal Circuit 5 108

OUT (+)
Brown
Dimensions
Main circuit

(mm)
of switch

OUT (–)
Blue
ø4

Indicator light/Display method Indicator light

Operating range ø4.5 mounting hole

Indication
Red Green Red

Proper operating range


Most sensitive position

D-쏔

1307
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 15

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Rail Mounting Style
D-F7BA(V)L
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F7BA(V)L (With indicator light)
쎲 Water (coolant) resistant type Auto switch model D-F7BAL D-F7BAVL
쎲 The proper operating range Electrical entry direction In-line Perpendicular
can be determined by the
Wiring type 2-wire
color of the light.
Output type —
(Red → Green ← Red)
Applicable load 24 VDC Relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking

Caution • Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2,
2 cores (Brown, Blue), 3 m (Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Precautions Note 2) Refer to page 1272 for lead wire lengths.

Please consult with SMC if using coolant


liquid other than water based solution. Mass (g)

Auto switch model D-F7BA D-F7BAV


0.5 — —
Lead wire length
3 50 50
(m)
5 81 81

Auto Switch Internal Circuit Dimensions (mm)

D-F7BAL ø3.2 mounting hole


Indicator light
OUT (+)
Brown
Main circuit
of switch

OUT (–)
Blue

Indicator light/Display method


Most sensitive position

Operating range D-F7BAVL ø3.2 mounting hole


8
Indication Indicator light
Red Green Red
15

SMC
7

Proper operating range


23

ø3.4
3.2
15
11

6.2

8.5 Most sensitive position

1308
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 16

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Tie-rod Mounting Style
D-F5BAL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F5BAL (With indicator light)
쎲 Water (coolant) resistant type Auto switch model D-F5BAL
쎲 The proper operating range Wiring type 2-wire
can be determined by the
Output type —
color of the light.
Applicable load 24 VDC Relay, PLC
(Red → Green ← Red)
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 40 mA
Internal voltage drop 4 V or less
Leakage current 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Caution Standard CE marking


• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 3 m (Standard)
Precautions Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Please consult with SMC if using coolant
liquid other than water based solution.

Mass (g)

Auto switch model D-F5BA


0.5 —
Lead wire length
3 71
(m)
5 111

Auto Switch Internal Circuit

Dimensions (mm)
OUT (+)
Brown
Main circuit
of switch

Mounting hole
OUT (–)
Blue
Indicator light
ø4

Indicator light/Display method

Operating range

Indication
Red Green Red

Proper operating range

Most sensitive position


D-쏔

1309
RoHS-SW-2.qxd 10.7.26 5:16 PM Page 2

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Direct Mounting Style
D-M9NA(V)/D-M9PA(V)/D-M9BA(V) RoHS

Auto Switch Specifications


Grommet PLC: Programmable Logic Controller

쎲 Water (coolant) resistant type D-M9쏔A, D-M9쏔AV (With indicator light)


쎲 2-wire load current is reduced (2.5 to Auto switch model D-M9NA D-M9NAV D-M9PA D-M9PAV D-M9BA D-M9BAV
40 mA). Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
쎲 The proper operating range can be Wiring type 3-wire 2-wire
determined by the color of the light.
Output type NPN PNP —
(Red → Green ← Red)
쎲 Using flexible cable as standard spec. Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Caution CE marking
Standard
Precautions 쎲Lead wires — Oilproof flexible heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores
Fix the auto switch with the existing screw (D-M9BA(V)), 3 cores (D-M9NA(V), D-M9PA(V))
installed on the auto switch body. The auto Note 1) Refer to page 1272 for solid state auto switch common specifications.
switch may be damaged if a screw other Note 2) Refer to page 1272 for lead wire lengths.
than the one supplied is used.
Mass (g)

Auto Switch Internal Circuit


Auto switch model D-M9NA(V) D-M9PA(V) D-M9BA(V)
D-M9NA, D-M9NAV
0.5 8 8 7
DC (+) Lead wire length 1 14 14 13
Brown
(m) 3 41 41 38
Main circuit

OUT
of switch

Black 5 68 68 63

Dimensions (mm)
DC (–)
Blue
M2.5 x 4 L
D-M9쏔A Slotted set screw
D-M9PA, D-M9PAV
Indicator light
DC (+)
Brown
4

SMC
Main circuit
of switch

2.8

2.7

OUT
24
Black
0.2

3.2
4

DC (–)
3

Blue

6 Most sensitive position


D-M9BA, D-M9BAV
OUT (+)
Brown
D-M9쏔AV
Main circuit
of switch

M2.5 x 4 L Indicator light


Slotted set screw
8
OUT (–) 2
4.6

3.2
Blue
4

SMC
Indicator light/Display method 2.7
2.8

ON
22
Operating
range OFF
2.6

Display
Red Green Red
9.3

Proper operating range


4

6 Most sensitive position

1310
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 18

Water Resistant 2-Color Indication Type


Solid State Auto Switch: Direct Mounting Style
D-Y7BAL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-Y7BAL (With indicator light)
쎲 Water (coolant) resistant type Auto switch model D-Y7BAL
쎲 Using flexible cable as
Wiring type 2-wire
standard spec.
Applicable load 24 VDC Relay, PLC
쎲 The proper operating range
Load voltage 24 VDC (10 to 28 VDC)
can be determined by the
Load current 2.5 to 40 mA
color of the light.
Internal voltage drop 4 V or less
(Red → Green ← Red)
Leakage current 0.8 mA or less at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light Proper operating range .......... Green LED illuminates.
Standard CE marking
• Lead wires — Oilproof flexible heavy-duty vinyl cord, ø3.4, 0.15 mm2, 2 cores (Brown, Blue), 3 m
(Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Caution
Precautions Mass (g)

Please consult with SMC if using coolant


liquid other than water based solution. Auto switch model D-Y7BA
Detection characteristics (operating range) 0.5 —
are the same as D-Y5쏔 and D-Y7쏔W, but Lead wire length
3 54
the detection area length is different. (m)
5 88

Dimensions (mm)
Auto Switch Internal Circuit
M2.5 x 4 L
Slotted set screw
OUT (+)
Brown 2.5 Indicator light
Main circuit
of switch

SMC
6.2

D-Y7BA

OUT (–)
35
Blue

Production lot

Indicator light/Display method


5.2
5

24 VDC

12.5 Most sensitive position


Operating range

Indication
Red Green Red

Proper operating range

D-쏔

1311
For Hygienic Design Cylinders
Solid State Auto Switch: Direct Mounting Style
D-F6N/D-F6P/D-F6B
Auto Switch Specifications
Grommet PLC: Programmable Logic Controller
D-F6 (With indicator light)
 2-wire load current is
Auto switch part no. D-F6N D-F6P D-F6B
reduced (2.5 to 40 mA)
Electrical entry direction In-line
 Using flexible cable as Wiring type 3-wire 2-wire
standard spec. Output type NPN PNP —
Applicable load IC circuit, relay, and PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 μA or less at 24 VDC 0.8 mA or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord: ø2.7 x 3.2 ellipse, 0.15 mm2, 2 cores (D-F6B),
3 cores (D-F6N, D-F6P)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Weight (g)
Caution
Precautions
Auto switch model D-F6N D-F6P D-F6B
Fix the auto switch with the existing screw
0.5 20 20 19
installed on the auto switch body. Lead wire length
3 53 53 50
The auto switch may be damaged if a screw (m)
other than the one supplied is used. 5 80 80 75

Dimensions (mm)
Auto Switch Internal Circuit
D-F6
D-F6N
8.5
DC (+)
Brown
Main circuit
of switch

OUT
Black Indicator light
(24)
16

DC (–)
Blue
2.7

10.6
ø7

29
D-F6P
DC (+)
Brown D-F6B
Main circuit
of switch

(22)

OUT
3.2

Black

DC (–)
Blue
7 Most sensitive position
D-F6B
OUT (+)
Brown D-F6N/F6P
Main circuit
of switch

(22)

3.2

OUT (–)
Blue
7 Most sensitive position

A 1312
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1313

Solid State Auto Switch with Timer


Band Mounting Style
D-G5NTL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

 With built-in OFF-delay timer D-G5NTL (With indicator light)


(approx. 200 ms) Auto switch model D-G5NTL
 Easy intermediate detection Wiring type 3-wire
Output type NPN
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leakage current 100 μA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-G5NT


0.5 —
Lead wire length
3 78
(m)
Auto Switch Internal Circuit 5 124

DC (+)
Timer Operation
Brown
Detection of intermediate positioning for high-speed cylinder
Main circuit
of switch

OUT Detecting point dispersion occurs due to


Black response time of PLC (sequencer); e.g. Auto switch operating range (mm)
Auto switch Cylinder speed (mm/s)
scanning. detecting time
Ex.) Cylinder speed — 1000 mm/sec.
Auto switch
DC (–) PLC response time — 0.1 sec. output ON time
Blue Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into considera- PLC response time
tion when using.

Dimensions (mm)
ø4

Indicator light
ø4.5 mounting hole D-

Most sensitive position

1313
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1314

Solid State Auto Switch with Timer


Rail Mounting Style
D-F7NTL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F7NTL (With indicator light)
 With built-in OFF-delay timer
Auto switch model D-F7NTL
(approx. 200 ms)
Wiring type 3-wire
 Easy intermediate detection
Output type NPN
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leakage current 100 μA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-F7NT


0.5 —
Lead wire length
3 57
(m)
Auto Switch Internal Circuit 5 92

Timer Operation
DC (+)
Brown
Detection of intermediate positioning for high-speed cylinder
Main circuit

Detecting point dispersion occurs due to


of switch

OUT response time of PLC (sequencer); e.g. Switch operating range (mm)
Black Switch detecting time Cylinder speed (mm/s)
scanning.
Ex.) Cylinder speed — 1000 mm/sec.
PLC response time — 0.1 sec. Switch output ON time
DC (–)
Blue
Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into considera- PLC response time
tion when using.

Dimensions (mm)

ø3.2 mounting hole


Indicator light
ø3.4

Most sensitive position

1314
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1315

Solid State Auto Switch with Timer


Tie-rod Mounting Style
D-F5NTL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-F5NTL (With indicator light)
 With built-in OFF-delay timer
Auto switch model D-F5NTL
(approx. 200 ms)
Wiring type 3-wire
 Easy intermediate detection
Output type NPN
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA)
Leakage current 100 μA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-F5NT


0.5 —
Lead wire length
3 81
(m)
Auto Switch Internal Circuit 5 127

DC (+)
Timer Operation
Brown
Detection of intermediate positioning for high-speed cylinder
Main circuit
of switch

OUT Detecting point dispersion occurs due to


Black response time of PLC (sequencer); e.g. Switch operating range (mm)
Switch detecting time Cylinder speed (mm/s)
scanning.
Ex.) Cylinder speed — 1000 mm/sec.
PLC response time — 0.1 sec. Switch output ON time
DC (–)
Blue Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
Take PLC response time into considera- PLC response time
tion when using.

Dimensions (mm)

Mounting hole

Indicator light
ø4

D-

Most sensitive position

1315
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1316

Solid State Auto Switch with Timer


Direct Mounting Style
D-M5NTL/D-M5PTL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-M5TL (With indicator light)
 With built-in OFF-delay timer
Auto switch model D-M5NTL D-M5PTL
(approx. 200 ms)
Wiring type 3-wire
 Easy intermediate detection
Output type NPN PNP
Output operation Off-delay
Operating time 1 ms or less
Off-delay time 200 ± 50 ms
Applicable load IC circuit, Relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less 12 mA or less
Load voltage 28 VDC or less —
Load current 80 mA or less
2 V or less
Internal voltage drop 0.8 V or less
(0.8 V or less at 10 mA load current)
Leakage current 100 μA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 3 m
(Standard)
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Auto switch model D-M5NT D-M5PT


Auto Switch Internal Circuit 0.5 — —
Lead wire length
3 60 60
D-M5NTL (m)
5 95 95
DC (+)
Brown
Timer Operation
Main circuit
of switch

OUT
Black Detection of intermediate positioning for high-speed cylinder
Detecting point dispersion occurs due to
response time of PLC (sequencer); e.g. Auto switch operating range (mm)
Auto switch Cylinder speed (mm/s)
scanning. detecting time
DC (–)
Blue Ex.) Cylinder speed — 1000 mm/sec.
Auto switch
PLC response time — 0.1 sec. output ON time
Detecting point dispersion — Within
100 mm (= 1000 mm/sec. x 0.1 sec.)
D-M5PTL Take PLC response time into considera- PLC response time
tion when using.
DC (+)
Brown
Dimensions (mm)
Main circuit
of switch

Indicator light
OUT
ø3.4

Black

DC (–)
Blue

ø3 mounting hole

Most sensitive position

1316
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1317

Magnetic Field Resistant 2-Color Indication Type


Solid State Auto Switch
D-P4DWSC/D-P4DWSE
(Electrical Entry: Pre-wired connector)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

 It is possible to use in an D-P4DWS (With indicator light)


environment which generates Auto switch model D-P4DWSC D-P4DWSE
a magnetic field disturbance Applicable load 24 VDC relay, PLC

(AC magnetic field). Load voltage 24 VDC (20 to 28 VDC)

 The optimum operating Load current 6 to 40 mA or less


position can be determined Internal voltage drop 5 V or less
by the color of the light. Leakage current 1 mA or less at 24 VDC
(Red → Green ← Red) Operating time 40 ms or less
Operating position .......... Red LED illuminates.
Indicator light
Optimum operating position .......... Green LED illuminates.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø6, 0.5 mm2, 2 cores, 300 mm
• Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Magnetic Field Resistance


Caution
If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if
Precautions the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm.
For single-phase AC welding machines. Please contact SMC when the AC welding current exceeds 16000 A.
Not applicable for DC inverter welding
machines (including rectifying type) and or
condenser type welding.
Mass (g)

Auto Switch Internal Circuit D-P4DWSC D-P4DWSE


Auto switch model
D-P4DWSC 35 35
Main circuit
of switch

NO.3 (OUT ±)
±
NO.4 (OUT )
Dimensions (mm)

Indicator light Connector size M12


ø6

D-P4DWSE
ø14
9.2
8.8

SMC

D-P4DW (24 VDC)


Main circuit
of switch

NO.1 (OUT ±) 32 4 300 44


±
NO.4 (OUT )

6 2 x ø3.5 mounting hole


1
6

Indicator light/Display method


20

ON
Operating Most sensitive
range OFF
Heat shrink tube Note)
13 position

Indication
Red Green Red Note) D-P4DWSC = “SC 3-4”, D-P4DWSE = “SE 1-4”
Optimum operating
position D-

2 1

3 4

Connector pin
1317
Magnetic Field Resistant 2-Color Indication Type
Solid State Auto Switch
D-P3DWSC/D-P3DWSE
(Electrical Entry: Pre-wired connector)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.
쎲 It is possible to use in an
PLC: Programmable Logic Controller
environment which generates
D-P3DWSC/E (With indicator light)
a magnetic field disturbance
Auto switch model D-P3DWSC D-P3DWSE
(AC magnetic field). 24 VDC relay, PLC
Applicable load
쎲 The proper operating range
Load voltage 24 VDC
can be determined by the
Load current 6 to 40 mA or less
color of the light.
(Red → Green ← Red) Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking, UL (CSA), RoHS
• Lead wire — Oilproof heavy-duty vinyl cable, ø4.8, 0.5 mm2, 2 cores
• Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2
• Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
• Ambient temperature — –10 to 60°C
• Enclosure — IEC60529 standard IP67
Caution • Polarity: Non-polar
Precautions
For single-phase AC welding machines Magnetic Field Resistance
If it is used for current inverter welders (in-
cluding rectifying type) and condenser type If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the
welders, the magnetic field resistance is distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm.
reduced. Please contact SMC regarding Please contact SMC when the AC welding current exceeds 16000 A.
the performance.
Weight (g)

Auto Switch Internal Circuit


D-P3DWSC Auto switch model D-P3DWSC D-P3DWSE
Lead wire length (m) 0.3 23
Main circuit
of switch

NO.3 (OUT ±)
±
Dimensions (mm)
NO.4 (OUT )
Body
ø4.8

Indicator light
ø14
6

D-P3DWSE
ø2.8 mounting hole
3
29 300 42.5
Main circuit
of switch

NO.1 (OUT ±)
1

±
NO.4 (OUT )
11

Note) A white color heat shrink


Most sensitive Heat shrink tube Note) tube is attached to the
3.2

10.5 position D-P3DWSE type only.


Indicator light/Display method
ON Auto switch mounting bracket Auto switch mounting bracket
Operating (For round groove mounting: (For square groove mounting:
range OFF
BQ3-032S) BMG5-025S)
Indication
Red Green Red 4.7 (29) 4.7 (29)

Proper operating
range
D-쏔
4
4

13.7 Most sensitive 6.2 13.7


2 1 Most sensitive
(15.2) position (15.2) position
3 4
∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed.
Connector pin In that case, please order it separately.
1317-1 C
Magnetic Field Resistant 2-Color Indication Type
Solid State Auto Switch
D-P3DW/L/Z
(Electrical Entry: Grommet)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.
쎲 It is possible to use in an
PLC: Programmable Logic Controller
environment which generates
D-P3DW/L /Z (With indicator light)
a magnetic field disturbance
Auto switch model D-P3DW/L/Z
(AC magnetic field). 24 VDC relay, PLC
Applicable load
쎲 The proper operating range
Load voltage 24 VDC
can be determined by the
Load current 6 to 40 mA or less
color of the light.
(Red → Green ← Red) Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking, UL (CSA), RoHS
• Lead wire — Oilproof heavy-duty vinyl cable, ø4.8, 0.5 mm2, 2 cores,
D-P3DW: 0.5 m, D-P3DWL: 3 m, D-P3DWZ: 5 m
• Impact resistance — Switch: 1000 m/s2
• Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
• Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
Caution • Ambient temperature — –10 to 60°C
Precautions • Enclosure — IEC60529 standard IP67
For single-phase AC welding machines • Polarity: Non-polar
If it is used for current inverter welders (in-
cluding rectifying type) and condenser type
Magnetic Field Resistance
welders, the magnetic field resistance is
If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the
reduced. Please contact SMC regarding
distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm.
the performance. Please contact SMC when the AC welding current exceeds 16000 A.

Auto Switch Internal Circuit Weight (g)

D-P3DW/L/Z
Auto switch model D-P3DW/L/Z
0.5 20
Main circuit
of switch

OUT (±) Brown Lead wire length (m) 3 102


OUT (±) Blue 5 168

Dimensions (mm)

Body
ø4.8

Indicator light
Indicator light/Display method
ON
6

Operating
range OFF ø2.8 mounting hole
3
29 500, (3000, 5000)
Indication
1

Red Green Red


11

Proper operating
range

Most sensitive
3.2

10.5 position

Auto switch mounting bracket Auto switch mounting bracket


(For round groove mounting: (For square groove mounting:
BQ3-032S) BMG5-025S)

4.7 (29) 4.7 (29)

4
4

13.7 Most sensitive 6.2 13.7


Most sensitive
(15.2) position (15.2) position

∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed.
In that case, please order it separately.
C 1317-2
Magnetic Field Resistant 2-Color Indication Type
Solid State Auto Switch
D-P3DWASC/D-P3DWASE
®

(Electrical Entry: Pre-wired connector)


Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.
 It is possible to use in an
PLC: Programmable Logic Controller
environment which generates
D-P3DWASC/E (With indicator light)
a magnetic field disturbance Auto switch model D-P3DWASC D-P3DWASE
(AC magnetic field). 24 VDC relay, PLC
Applicable load
 The proper operating range 24 VDC
Load voltage
can be determined by the
Load current 6 to 40 mA
color of the light.
(Red → Green ← Red) Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking, UL (CSA), RoHS

Oilproof Heavy-duty Cord Specifications


Auto switch models D-P3DWASC D-P3DWASE
Sheath Outside diameter [mm] ø4.8
Number of cores 2 cores
Insulator
Caution Outside diameter [mm] ø1.52
Precautions Effective area [mm2] 0.5
Conductor
For single-phase AC welding machines Strand diameter [mm] ø0.08
If it is used for current inverter welders Minimum bending radius [mm] (Reference values) 29
(including rectifying type) and condenser
type welders, the magnetic field resistance  Impact resistance — Switch: 1000 Connector: 300m/s2, m/s2
is reduced. Please contact SMC regarding  Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
the performance.  Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
 Ambient temperature — –10 to 60°C
 Enclosure — IEC60529 standard IP67
 Polarity: Non-polar

Magnetic Field Resistance


If the current of the AC welding machine is Dimensions (mm)
16000 A or lower, the auto switch can be used, Body
even if the distance between the welding
Switch mounting thread M2.5 x 12L SUS
conductor (gun cable) and the cylinder/actuator
or auto switch is 0 mm. Indicator light Connector size M12
Please contact SMC when the AC welding
current exceeds 16000 A. For pre-wired
ø14

D-P3DWA connector
6

(300 mm)
ø4.8

Weight (g)
3
29 300 42.5

Auto switch model D-P3DWASC D-P3DWASE


1

Lead wire length (m) 0.3 25


14.3
11

3.95

Heat shrink tube Note)


3.3

10.5 Most sensitive position

Note) A white color heat shrink tube is attached to the D-P3DWASE type only.
2 1

3 4

Connector pin

Connector pin and wiring


Model
1 2 3 4
±
D-P3DWASC — — OUT( ) OUT(±)
±
D-P3DWASE OUT(±) — — OUT( )

1317-3 B
Magnetic Field Resistant 2-Color Indication Type
Solid State Auto Switch
D-P3DWA
®

(Electrical Entry: Grommet)


Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.
 It is possible to use in an
PLC: Programmable Logic Controller
environment which generates
D-P3DWA (With indicator light)
a magnetic field disturbance Auto switch model D-P3DWA
(AC magnetic field). 24 VDC relay, PLC
Applicable load
 The proper operating range 24 VDC
Load voltage
can be determined by the
Load current 6 to 40 mA
color of the light.
(Red → Green ← Red) Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking, UL (CSA), RoHS

Oilproof Heavy-duty Cord Specifications


Auto switch models D-P3DWA
Sheath Outside diameter [mm] ø4.8
Number of cores 2 cores (Brown/Blue)
Caution Insulator
Outside diameter [mm] ø1.52
Precautions
Effective area [mm2] 0.5
For single-phase AC welding machines Conductor
If it is used for current inverter welders Strand diameter [mm] ø0.08
(including rectifying type) and condenser Minimum bending radius [mm] (Reference values) 29
type welders, the magnetic field resistance
 Impact resistance — Switch: 1000 m/s2
is reduced. Please contact SMC regarding  Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case)
the performance.  Withstand voltage — 1000 VAC for 1 minute (between lead wire and case)
 Ambient temperature — –10 to 60°C
 Enclosure — IEC60529 standard IP67
 Polarity: Non-polar

Magnetic Field Resistance Dimensions (mm)

If the current of the AC welding machine is Body


16000 A or lower, the auto switch can be used, Switch mounting thread M2.5 x 12L SUS
even if the distance between the welding con-
ø4.8

ductor (gun cable) and the cylinder/actuator or Indicator light


auto switch is 0 mm. Please contact SMC when
D-P3DWA
6

the AC welding current exceeds 16000 A.


3
Weight (g)
29 500 (3000) (5000)
1

Auto switch model D-P3DWA


14.3
11

0.5 m (Nil) 22 3.95


Lead wire
length 3 m (L) 104
3.3

5 m (Z) 170 10.5 Most sensitive position

B 1317-4
Magnetic Field Resistant 2-Color Indication Type
Solid State Auto Switch
D-P4DWSC/D-P4DWSE
(Electrical Entry: Pre-wired connector)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

쎲 It is possible to use in an D-P4DWS쏔 (With indicator light)


environment which generates Auto switch model D-P4DWSC D-P4DWSE
a magnetic field disturbance Applicable load 24 VDC relay, PLC

(AC magnetic field). Load voltage 24 VDC (20 to 28 VDC)

쎲 The proper operating range Load current 6 to 40 mA or less


can be determined by the Internal voltage drop 5 V or less
color of the light. Leakage current 1 mA or less at 24 VDC
(Red → Green ← Red) Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø6, 0.5 mm2, 2 cores, 300 mm
• Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Magnetic Field Resistance


Caution
If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if
Precautions the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm.
For single-phase AC welding machines. Please contact SMC when the AC welding current exceeds 16000 A.
Not applicable for DC inverter welding
machines (including rectifying type) and or
condenser type welding.
Weight (g)

Auto Switch Internal Circuit D-P4DWSC D-P4DWSE


Auto switch model
D-P4DWSC 35 35
Main circuit
of switch

NO.3 (OUT ±)
±
NO.4 (OUT )
Dimensions (mm)

Indicator light Connector size M12


ø6

D-P4DWSE
ø14
9.2
8.8

SMC

D-P4DW (24 VDC)


Main circuit
of switch

NO.1 (OUT ±) 32 4 300 44


±
NO.4 (OUT )

6 2 x ø3.5 mounting hole


1
6

Indicator light/Display method


20

ON
Operating Most sensitive
range OFF
Heat shrink tube Note)
13 position

Indication
Red Green Red Note) Only for D-P4DWSE
Printed contents: SE 1-4
Proper operating
range
D-쏔

2 1

3 4

Connector pin
1317-5 A
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 22

Magnetic Field Resistant 2-Color Indication Type


Solid State Auto Switch
D-P4DWL/Z
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

쎲 It is possible to use in an D-P4DWL/Z (With indicator light)


environment which generates Auto switch model D-P4DWL D-P4DWZ
a magnetic field disturbance Applicable load 24 VDC relay, PLC

(AC magnetic field). Load voltage 24 VDC (20 to 28 VDC)

쎲 The proper operating range Load current 6 to 40 mA or less


can be determined by the Internal voltage drop 5 V or less
color of the light. Leakage current 1 mA or less at 24 VDC
(Red → Green ← Red) Operating time 40 ms or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø6, 0.5 mm2, 2 cores (Brown, Blue),
D-P4DWL: 3 m, D-P4DWZ: 5 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.

Mass (g)

Caution
Precautions Auto switch model D-P4DW
For single-phase AC welding machines. 0.5 —
Not applicable for DC inverter welding Lead wire length
3 150
machines (including rectifying type) and or (m)
5 244
condenser type welding.

Auto Switch Internal Circuit Magnetic Field Resistance


D-P4DWL/Z If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if
the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm.
Please contact SMC when the AC welding current exceeds 16000 A.
Main circuit
of switch

OUT (±) Brown


±
OUT ( ) Blue

Dimensions (mm)

Indicator light
Indicator light/Display method
ø6

ON
9.2
8.8

SMC

D-P4DW (24 VDC)


Operating
range OFF

32 4
Indication
Red Green Red

Proper operating 6 2 x ø3.5 mounting hole


range
1
6
20

13 Most sensitive position

1318
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 23

Heat Resistant 2-Color Indication Type


Solid State Auto Switch: Rail Mounting Style
D-F7NJL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

쎲 Improved heat resistant type D-F7NJL (With indicator light)


Auto switch model D-F7NJL
쎲 The proper operating range
can be determined by the Wiring type 3-wire

color of the light. Output type NPN


(Red → Green ← Red) Applicable load Relay, PLC
Power supply voltage 24 VDC (20 to 26 VDC)
Current consumption 25 mA or less
Load voltage 28 VDC or less
Load current 40 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA at 24 VDC
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Sensor section: 0 to 150°C


Ambient temperature
Caution Amplifier section: 0 to 60°C
Precautions Sensor section: 1000 m/s2
Impact resistance
Auto switch which can be mounted on heat Amplifier section: 300 m/s2
resistant, compact cylinder, CDQ2-XB14. For Standard CE marking
using for other cylinders, please confirm
SMC. • Lead wires — Between sensor and amplifier: Heat resistant heavy-duty cord, ø3.4, 3 m
D-F7NJL is not applicable for the heat Grommet on amplifier: Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores
resistant type (-XB6) since a magnet is not (Brown, Black, Blue), 3 m
built in it.

Mass (g)

Auto Switch Internal Circuit Auto switch model D-F7NJ


0.5 —
Lead wire length
Amplifier section 3 170
(m)
Sensor section DC (+) 5 210
Brown lead wire
Main circuit

Main circuit
of sensor

OUT
of switch

Black lead wire


Dimensions (mm)

Max. 150°C OUT (–)


Blue lead wire
Max. 60°C
Indicator light
3.8 21.6
Indicator light/Display method
AUTO SWITCH
HEAT PROOF

MODE POSITION
AMPLIFIRE
22

SMC

7
15

(4) (64.5) 0.7 8


Operating range

Indication
Red Green Red 3000 (5000)

Heat resistant heavy-duty cord


ø3.4

Proper operating range


3
D-F7NJ

DC24V
Load
BLACK(OUT) NPN 24V40mA
BROWN

11
BLACK

40mA

CAUTION
MAX.

BLUE
24VDC

MADE IN JAPAN
GND
OUT
Vcc

Don't install heated atmosphere.


It might cause mal function and
GND
40

circuit (amplifire) is 0~60°C.


Ambient temp. of detecting

lead to cause breakage.


BROWN(+)

D-쏔
6.2
BLUE (-)

Switch
Main Circuit

ø3.4

Most sensitive
position 8.5
3000

1319
2-2-47-D-UMASw.qxd 09.9.30 3:23 PM Page 11

Wide Range Detection Type


Solid State Auto Switch: Band Mounting Style
D-G5NBL
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

쎲 Wide range detection type D-G5NBL (With indicator light)


Auto switch model D-G5NBL
쎲 Easy intermediate detection
Wiring type 3-wire
Output type NPN
Applicable load Relay, PLC
Power supply voltage 12, 24 VDC (10 to 28 VDC)
Current consumption 12 mA or less
Load voltage 10 to 28 VDC or less
Load current 40 mA or less
Internal voltage drop 0.4 V or less
Leakage current 100 µA at 24 VDC
Indicator light Red LED illuminates when turned ON.
Caution Standard CE marking
Precautions • Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 3 cores (Brown, Black, Blue), 3 m
Note 1) Refer to page 1272 for solid state auto switch common specifications.
The operating range is common for all Note 2) Refer to page 1272 for lead wire lengths.
cylinder series, but it may vary depending on
bore sizes. Mass (g)

Auto switch model D-G5NB


0.5 —
Lead wire length
3 79
(m)
5 125

Applicable Cylinders
Cylinder series Bore size (mm)
CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, MLGC 20, 25, 32, 40
Auto Switch Internal Circuit CDG1 20, 25, 32, 40, 50, 63, 80, 100
D-G5NBL CDA2, CDBA2, CDV3, CDVS1, CDL1 40, 50, 63, 80, 100
MGC, MGG 20, 25, 32, 40, 50
DC (+)
Brown Operating Range
Main circuit
of switch

OUT
Black Bore size (mm)
Cylinder series
20 25 32 40 50 63 80 100
OUT (–) Mountable models 35 40 40 45 45 45 45 50
Blue
Note) The operating range above indicates average values at room temperature including
hysteresis (assuming approximately ±30% dispersion).
∗ Refer to page 405 for CDA2 and CDBA2.

Dimensions (mm)

D-G5NB
33 11.2
ø4
SMC
14

12

Indicator light

6.5 ø4.5 mounting hole


14.3

9.5

(16) Most sensitive position

1320
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1321

Trimmer Auto Switch


Series D- 7K/D-R K

OUT1 and OUT2 are


adjustable separately.
Large work piece
OUT1 Trimmer OUT2 Trimmer

Operating range of sensor (LED of sensor is on.)


Medium work piece
OUT1 Detecting range
Output ON = Green LED is on.

OUT2 Adjustable by trimmer

Small work piece OUT2 Detecting range


Output ON = Orange LED is on.

Adjustable by
trimmer

No work piece Small work piece Medium work piece Large work piece

h s to y.
itc iece asil
OUT1 o s w p de
u t o k
r she
c t
e a w ui
d ete n s g
to O low tin
w i d th
m e
an b .
al dis OUT2

5 mwork pihecaen 0.5 mm be OUT1


u m s c
inim
0.
t
M d t
size f more depe
nda
n
u s o h
rio nce e wid t
, va e l
sw itch differ tectab tuator.
n e t h e o de d ac
ho by t lie
Wit tected 0.5 mm n app
de m o
ro
∗F

Examples
To confirm depth of
the machined hole
To judge height
of a work piece • Can be mounted on • Two mounting D-
a standard actuator. types (Amplifier unit)
Direct mounting / Rail mounting DIN rail mounting / Direct mounting

• Joining of connector • IP67 (Sensor unit)


Sensor and amplifier can be connected without restriction. IP40 for amplifier

1321
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 24

Trimmer Auto Switch

Series D-쏔7K/D-R쏔K
Specifications
Sensor unit
Sensor Unit
Direct mounting type
Model D-F7K D-Y7K
Mounting Rail mounting Direct mounting
Applicable amplifier unit D-RNK, D-RPK

Rail mounting type Indicator light Operating position: Red light is ON. Proper operating range: Green light is ON.
Electrical entry Grommet
Oilproof heavy-duty vinyl cord ø3.5 0.14 mm2 4 cores 3 m
Lead wire
With one e-con connector Note)
Impact resistance 980 m/s2
Amplifier unit
Insulation resistance 50 MΩ or more (500 VDC Mega) between lead wire and case
Withstand voltage 1000 VAC for 1 min. (between lead wire and case)
Ambient temperature –10 to 60°C
Enclosure IP67
Mass 58 g (with connector)
Standard CE marking
Internal Circuit Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipment.

Sensor Unit
Amplifier Unit (with Sensor Unit) PLC: Programmable Logic Controller
D-쏔7K Model D-RNK D-RPK
Vsw (Brown) Applicable sensor unit D-F7K, D-Y7K
Main circuit
of switch Application For relay and PLC
GND (Blue) Power supply voltage 12 to 24 VDC
Detective SOUT 1 (Black) Current consumption 40 mA or less
sensor SOUT 2 (White)
Output specification NPN open collector 2 outputs PNP open collector 2 outputs
Load voltage 28 VDC or less —
Amplifier Unit
Load current 80 mA or less/1 output
D-RNK Internal voltage drop 1.5 V or less
Sensor DC (+)
(Brown) Leakage current 100 µA or less/1 output
Brown
Load

4
12 to
Response time 1 ms or less
Main circuit

White OUT 1 24 VDC


3 (Black)
Load

READY: Red LED illuminates when the piston position detected.


Blue OUT 2
2 (When the sensor is connected).
(White)
Black Indicator light
1 DC (–) OUT 1: Green LED illuminates when turned ON.
(Blue)
OUT 2: Orange LED illuminates when turned ON.

D-RPK Electrical Connection e-con connector


to sensor
entry
Sensor DC (+) Power supply/ Grommet
Brown (Brown) output cable
4
12 to
Lead wire Oilproof heavy-duty vinyl cord ø3.5 0.14 mm2 4 cores 3 m
Main circuit

White OUT 1 24 VDC


3 (Black)
Load

OUT 2 Impact resistance 98 m/s2


Blue
2 (White)
Insulation resistance 50 MΩ or more (500 VDC Mega) between lead wire and case
Load

Black
1 DC (–)
(Blue)
Withstand voltage 1000 VAC for 1 min. (between lead wire and case)
Ambient temperature –10 to 60°C
Enclosure IP40
Mass 70 g
Standard CE marking
1322
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 25

Trimmer Auto Switch Series D- 쏔7K/D-R 쏔K

Descriptions
Sensor unit Sensor Unit
w q Red light turns ON when sensor detects the
magnet field. Green light is ON during the
q 1 Indicator light
proper operating range to detect the magnetic
field (including most sensitive position).
2 ø3.2 mounting hole
M2.5 x 4L slotted Fixes the sensor to the actuator.
3
set screw

Amplifier Unit
e 1 Output (OUT1) indication: Green Illuminates when OUT1 outputs.
Adjusts the output range of OUT1 when
D-F7K D-Y7K 2 OUT1 adjusting trimmer
sensor unit detects the magnetic field.
3 Output (OUT2) indication: Orange Illuminates when OUT2 outputs.
Amplifier unit
Adjusts the output range of OUT2 when
4 OUT2 adjusting trimmer
q sensor unit detects the magnetic field.
w y Confirmation of detection at
Illuminates when sensor unit is detecting
5 the magnetic field. While its lighting, output
e u
sensor unit (READY): Red
ranges of OUT1 and OUT2 are adjustable.
r Adjusts the sensor unit at the time of connection.
t Once adjusts, no need to re-adjust as long
Offset adjusting trimmer as the sensor unit is not replaced.
6
(ADJ) Adjustment must be undertaken while the
sensor unit is removed from the actuator.
Refer to the operation manual for details.
Confirmation of offset Illuminates when offset adjustment is
7
adjustment (OFFSET): Red completed.
D-R쏔K

Refer to the operation manual for how to adjust/set.


The operating ranges are provided as guidelines including the hysteresis and are not guaranteed
Applicable Actuators and Operation Range (Angle) value. Please consult with SMC for alternative actuators other than those shown below.

Sensor Unit D-Y7K


Air Gripper (mm or °)
Bore size
Model
10 12 16 20 25 32 40 50 63 80 100
Parallel gripper MHZ2 4.0 — 5.0 7.0 7.0 8.0 8.5 — — — —
Parallel gripper MHZL2 6.0 — 7.0 10.0 11.0 — — — — — —
Wide opening MHL2 7.0 — 8.0 8.5 10.5 11.0 12.5 — — — —
Parallel gripper MHS2 (2 finger) — — — — — 6.5 7.0 7.5 8.5 — —
Parallel gripper MHS3 (3 finger) MHS (L) 3 — — — — — 6.5 7.0 7.5 8.0 — —
Parallel gripper MHS4 (4 finger) — — — — — 6.5 7.0 7.5 8.5 — —
Angular gripper MHC2 30° to –10° — 30° to –10° 30° to –10° 22.5° to –10° — — — — — —
180° opening/closing MHW2 — — — 88° to –5° 54° to –6° 58° to –5° 41° to –5° 30° to –4° — — —
Note) The operating range for grippers is measured when both ends are open.
Air Cylinder
Compact guide cylinder MGP — 3.5 5.0 4.5 4.5 5.5 5.5 5.5 5.5 5.5 6.0
Double power non-rotating cylinder MGZ — — — — — — 5.5 6.5 6.5 — —
Air cylinder CA2 — — — — — — 4.0 4.0 6.0 6.0 6.0

Sensor Unit D-F7K


Air Cylinder (mm)
Bore size
Model
10 12 16 20 25 32 40 50 63 80 100 125 140 160
Air cylinder CJ2 4.0 — 4.5 — — — — — — — — — — — D-쏔
Air cylinder CM2 — — — 3.5 3.5 3.5 3.5 — — — — — — —
Compact cylinder CQ2 4.5 4.5 5.5 5.5 5.0 5.5 5.5 5.5 6.0 5.5 6.0 7.5 7.5 7.5
Compact cylinder guide rod type CQM — — — — — 5.5 5.5 5.5 — — — — — —
Plate cylinder MU — — — — 5.5 6.5 6.5 6.5 6.5 — — — — —
3 position cylinder RZQ — — — — — 6.0 6.5 7.0 7.5 — — — — —
Rotary clamp cylinder MK/MK2 — — — 5.0 5.0 6.5 6.0 6.0 6.5 — — — — —
1323
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1324

Series D- 7K/D-R K

Dimensions (mm)

Sensor unit
D-F7K 8
ø3.2

ø3.5
4
15

SMC
7

23 4.6 3000
1

3.2
D-F7K
11

6.2
8.5 Most sensitive position

D-Y7K 2.5 M2.5 x 4L

ø3.5
Slotted set screw
SMC
6.2

33 2 3000
5
0.4

D-Y7K
10.6

12.5 Most sensitive position

Amplifier unit
D-RK 7.7 12.5 56 5 3000
2.6

OUT1 OUT2 READY TRIMMER


12
8.6

SWITCH
SMC
ø3.5

DIN rail (35 mm width)


Supplied by customer.
21.1

D-RNK
30
6

2 x ø3.5

5 46
Note) The figures above are for D-RNK. For D-RPK,
Connector for sensor the model name will be printed instead on the
e-con body.
1324
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 26

Trimmer Auto Switch


Specific Product Precautions 1
Be sure to read before handling.
Refer to front matters 54 and 55 for Safety Instructions and pages 8 to 11 for the Auto
Switch Common Precautions.

Design and Selection Wiring

Warning Caution
1. Confirm the specifications. 1. Avoid repeatedly bending or stretching lead
Read the specifications carefully and use this product appro- wires.
priately. The product may be damaged or malfunction if it is Broken lead wires will result from applying bending stress or
used outside the range of specifications of current load, vol- stretching forces to the lead wires.
tage, temperature or impact.
2. Be sure to connect the connector for sensor
2. Cautions for use in an interlock circuit. to the amplifier before power is applied.
When an auto switch is used for an interlock signal requiring high
reliability, devise a double interlock system to avoid trouble by 3. Do not allow short circuit of loads.
providing a mechanical protection function, or by also using an- Output is automatically stopped when the protection circuit is
other switch (sensor) together with the trimmer auto switch. Also working, as the output unit registers any excess current flow, if
perform periodic maintenance and confirm proper operation. loads are short circuited. Should this occur, shut off the power
supply, remove the cause of this excess current flow and
switch on the power again. Take special care to avoid reverse
Caution wiring between the power supply line (brown) and the output
line (black, white).
1. Take precautions when multiple cylinders
are used close together. 4. Avoid incorrect wiring.
When more than 2 trimmer auto switch cylinders are used in If the connections are reversed (power supply line + and power
close proximity, maintain a minimum actuator interval of 40 supply line –), the trimmer auto switches will be protected by a
mm or more. (When the allowable interval is indicated for each protection circuit. However, if the power supply line (–) is con-
cylinder series, use the specified values.) Magnetic field inter- nected to the black, white wire, the trimmer auto switches will
ference may cause the trimmer auto switches to malfunction. be damaged.

2. Keep the wiring as short as possible.


Use a wire 3 m or shorter between the sensor and amplifier. Operating Environment
Although wire length of power supply/output cable should not
affect switch function, use a wire 100 m or shorter.
Warning
3. Take precautions for the internal voltage
drop of the switch. 1. Never use in an atmosphere with explosive
Auto switches may not operate properly depending on the con-
gases.
nected equipment. The structure of trimmer auto switches is not designed to pre-
vent explosion. Never use in an atmosphere with an explosive
4. Take measures for rotational stoppage of the gas since this may cause a serious explosion.
piston rod.
Take measures for rotational stoppage of the piston rod when de-
signing by guide, etc. Or use non-rotating type SMC products. Caution
The operation may be unstable. 1. Do not use in an area where a magnetic field
is generated.
Mounting and Adjustment Trimmer auto switches will malfunction or magnets inside ac-
tuators will become demagnetized.
Caution 2. Do not use in an environment where the
trimmer auto switch will be continually ex-
1. Do not drop or bump.
Do not drop, bump or apply excessive impacts (980 m/s2 or
posed to water.
more for sensor unit and 98 m/s2 or more for amplifier unit) Although the sensor units of trimmer auto switches satisfy the
while handling. IEC standard IP67 structure, do not use trimmer auto
Although the trimmer auto switch body may not be damaged, switches in applications where continually exposed to water
the inside of the trimmer auto switch could be damaged and splash or spray. Poor insulation or swelling of the potting resin
cause a malfunction. inside trimmer auto switches may cause malfunction.
(Amplifier part D-RNK and RPK: IP40)
3. Do not use in an environment with oil or
chemicals.
Please consult with SMC if trimmer auto switches will be used
in an environment with coolant, cleaning solvent, various oils D-쏔
or chemicals. If trimmer auto switches are used under these
conditions for even a short time, they may be adversely affec-
ted by improper insulation, malfunction due to swelling of the
potting resin, or hardening of the lead wires.
4. Take measures against freezing when oper-
ating at 5°C or less.

1325
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1326

Trimmer Auto Switch


Specific Product Precautions 2
Be sure to read before handling.
Refer to front matters 54 and 55 for Safety Instructions and pages 8 to 11 for the Auto
Switch Common Precautions.

Maintenance Wiring

Warning Caution
1. Perform the following maintenance periodically 1. Connection and removal of connector
in order to prevent possible danger due to • Hold the lever and connector body with two fingers and in-
unexpected trimmer auto switch malfunction. sert the connector straight into the pin until it is locked with a
click sound.
1) Secure and tighten trimmer auto switch mounting screws. • To remove the connector, pull it out straight while pressing
If screws become loose or the mounting position is dis- the lever with one finger.
located, retighten them after readjusting the mounting posi-
tion.
2) Confirm that there is no damage to lead wires.
To prevent faulty insulation, replace trimmer auto switches K
D-RN
or repair lead wires, etc., if damage is discovered. D-Y7
K

Lever
Other
2. Connection of sensor connector
Caution • Cut the sensor lead wire as illustrated to the right.
• Referring to the table below, insert each lead wire of the
1. Please consult with SMC concerning water cable at the position marked with a number corresponding to
resistance, elasticity of lead wires, and the color of the lead wire.
usage at welding sites, etc. Sheath 20 mm or more

Insulator

Connector no. Wire core color


1 Black (SOUT1)
2 Blue (GND)
3 White (SOUT2)
4 Brown (Vsw)
• Confirm that the numbers on the connector match the colors
of the lead wires and that they are inserted to the bottom.
Press part A by hand for temporary fixing.
• Press in the central part of Part A vertically with a tool such
as pliers.
• A sensor connector cannot be taken apart for reuse once it is
crimped. If the lead wire arrangement is incorrect or if the
wire insertion fails, use a new sensor connector.

Part A

• Use a sensor conector, ZS-28-CA-3 (1 pc.) or e-con connec-


tors as shown below.
Manufacturer Part no.
Sumitomo 3M Limited 37104-3122-000FL
Tyco Electronics AMP K.K. 1473562-4
OMRON Corporation XN2A-1430
• For detailed information about e-con connectors, please con-
sult with the manufacturers of the respective connectors.

1326
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1327

Trimmer Auto Switch


Specific Product Precautions 3
Be sure to read before handling.
Refer to front matters 54 and 55 for Safety Instructions and pages 8 to 11 for the Auto
Switch Common Precautions.

Mounting of Amplifier Unit


Caution
• Use mounting screws (M3 x 16L) or DIN rail (35 mm width). 2. Mounting and removal to DIN rail
(DIN rail part no.: ISA-2-1 to 7) Removal
Mounting
• Adjust offset before mounting of the amplifier unit. • To remove from the DIN rail,
• Hook the claw 1 of the am-
plifier body to the upper part push the amplifier body up-
1. Mounting with screws of DIN rail, press down and ward and then pull it hori-
• Tighten two M3 x 16L mounting screws at a tightening torque push horizontally until the zontally to release from the
of 0.5 to 0.7 N·m. claw 2 is locked with a click claw 1 side.
• Mounting surface should be flat and even. A bumpy or un- sound.
even mounting surface can result in damage to the case.
Claw 1

OUT1

OUT1
OUT2

OUT2
READY TRIM

READY TRIMMER
SWITCH

SWITCH
SMC

MER

SMC
Claw 2

Washer
M3 x 16L

OUT1

OUT1
OUT2

OUT2
READY TRIMMER
SWITCH

SWITCH
TRIMMER
SMC

SMC
• In the case of mounting to the
DIN rail, SMC recommends the
following end plates: as de- Manufacturer Part no.
tailed in the table on the right. OMRON Corporation PFP-M
Consult each manufacturer for IDEC Corporation BNL6
the handling and details of end
plate.

3. Refer to each applicable actuator’s catalog


for the mounting of sensor unit.

D-

1327
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1328

Made to Order Specifications:


Solid State Auto Switch
Refer to SMC website for the details of
the products conforming to the
international standards.

1 With Pre-wired Connector


• Eliminates the harnessing work by cable with connector specifications
• Adopts global standardized connector (IEC947-5-2)
• IP67 construction

How to Order

Connector Specifications
D M9N S A PC Connector model M8-3 pin M8-4 pin M12-4 pin

1 4 1 2

2 1
Solid state auto switch Pin arrangement
Standard part no. 3 4
∗ For the applicable auto switch 3 3 4
model, refer to the table below.
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
Cable length Connector model
Impact resistance 300 m/s2
S 0.5 m A M8-3 pin
M 1.0 m B M8-4 pin Enclosure IP-67 (IEC60529 standard)
L 3.0 m D M12-4 pin Insulation resistance 100 MΩ or more at 500 VDC Mega
Note) L is available Note) Type D is
for the D-P4DW available for the Withstand voltage 1500 VAC 1 minute (between contacts), Leak current 1 mA or less
type only. D-P4DW type
only.

Applicable Auto Switch

Electrical Lead wire length (m) Electrical Lead wire length (m)
Mounting Function Applicable model Mounting Function Applicable model
entry 0.5 1.0 3.0 entry 0.5 1.0 3.0
Grommet (In-line) F79, F7P, J79   — Grommet (In-line) Y59A, Y7P, Y59B   —
— Grommet Grommet
(Perpendicular) F7NV, F7PV, F7BV   — (Perpendicular) Y69A, Y7PV, Y69B   —
2-color Grommet (In-line) F79W, F7PW, J79W   — Grommet (In-line) M9N, M9P, M9B   —
Grommet —
Rail indication (Perpendicular) F7NWV, F7BWV   — Grommet M9NV, M9PV, M9BV   —
mounting With diagnostic output F79F   — (Perpendicular) F8N, F8P, F8B   —
style Grommet (In-line)
F7BA   — Grommet (In-line) F6N, F6P, F6B   —
Water resistant Grommet
(Perpendicular) F7BAV   — Direct Normally Y7G, Y7H   —
Grommet (In-line)
With timer F7NT   — mounting closed F9G, F9H   —
style
Magnetic field resistant P4DW    Grommet (In-line) Y7NW, Y7PW, Y7BW   —
Grommet
H7A1, H7A2, H7B   — 2-color (Perpendicular) Y7NWV, Y7PWV, Y7BWV   —
— indication
G59, G5P, K59   — Grommet (In-line) M9NW, M9PW, M9BW   —
Grommet
2-color H7NW, H7PW, H7BW   — (Perpendicular) M9NWV, M9PWV, M9BWV   —
Band indication G59W, G5PW, K59W   — Y7BA   —
mounting Grommet (In-line)
style Diagnostic output Grommet (In-line) H7NF, G59F   — Water resistant M9NA, M9PA, M9BA   —
Grommet
Water resistant H7BA, G5BA   — (Perpendicular) M9NAV, M9PAV, M9BAV   —
With timer G5NT   — S791/2, S7P1/2, T791/2   —
Rotary Grommet (In-line)
Wide detection G5NB   — actuator — S991/2, S9P1/2, T991/2   —
Grommet
— F59, F5P, J59   — (Perpendicular) S99V1/2, T99V1/2   —
Tie-rod 2-color indication F59W, F5PW, J59W   —
mounting Diagnostic output F59F   —
style  
Water resistant F5BA —
With timer F5NT   —

1328
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1329

With Pre-wired Connector

Connector Pin Arrangement

Color distinction of lead wire Meaning of contact number


Sensor type
1 pin 2 pin 3 pin 4 pin 1 pin 2 pin 3 pin 4 pin
DC 2-wire type Brown — — Blue OUT (+) — — OUT (–)
±
DC 2-wire, Non-polar type — — Brown Blue — — OUT (±) OUT ( )
DC 3-wire type Brown — Blue Black DC (+) — DC (–) OUT
DC 4-wire type Brown Diagnostic OUT
Orange Blue Black DC (+) output DC (–)

Connector Specifications
M8-3 pin Connector model M8-3 pin M8-4 pin M12-4 pin

1 4 1 2

2 1
Pin arrangement
3 4
3 3 4

Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402

Impact resistance 300 m/s2

Enclosure IP67 (IEC60529 standard)

Insulation resistance 100 MΩ or more at 500 VDC Mega

Withstand voltage 1500 VAC 1 minute (between contacts), Leak current 1 mA or less

M8-4 pin Dimensions

Connector model

ø10
Sensor section
M8-3 pin
4 pin
31.4

M12-4 pin
ø14

Sensor section
M12-4 pin

44

Mass for Connector Type Connection (Female side) Connector Cable


Part no. Connector type Mass As the parts are not supplied from SMC, refer to the application examples listed in the below.
(For detail such as catalog availability, etc., please contact each manufacturer.)
D-APC M8-3 4g
D-BPC M8-4 4g Connector size Number of pins Manufacturer Applicable series example

D-DPC M12-4 About 11 g Phoenix Contact SAC-3P


3
M8-3D
M8 Corrence Corporation
M8-4D
OMROM Corporation XS3
Phoenix Contact SAC-4P
D-
Corrence Corporation VA-4D
4
OMROM Corporation XS2
M12
Yamatake Corporation PA5-4I
Hirose Electric Co., Ltd. HR24
DKK Ltd. CM01-8DP4S

1329
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1330

Made to Order Specifications: Solid State Auto Switch


-50: Without Indicator Light (Dark room) Specifications
-61: Oilproof Flexible Cable Specifications

Symbol
2 Without Indicator Light (for dark room specifications) -50
Possible to use under the environment which hates a light.

D 50

Without indicator light


Solid state auto switch model (for dark room specifications)
Applicable part no.: General purpose type,
solid state auto switch
except D-J51 Lead wire length
For lead wire length, refer to page 1272.
Note) Please consult with
SMC for water
resistant type, timer
equipped type,
diagnostic output type,
wide range detection
type, magnetic field
resistant type, heat
resistant type.

Dimensions and specifications are common as standard products with the exception of no indicator light.

Symbol
3 Oilproof Flexible Heavy-duty Cord Specifications -61
This is the product which uses a heavy-duty cord having flexible characteristics 5 times (SMC
comparison) as strong as oilproof heavy-duty cord used in the standard products.

D 61
Solid state auto switch part no.
Applicable part no: All the solid state auto
switches with the
exceptance of D-J51,
diagnostic output type,
Oilproof flexible heavy-duty cord
terminal conduit type, specifications
connector type,
magnetic field resistant
type, heat resistant
Lead wire length
type For lead wire length, refer to page 1272.
Note) Oilproof flexible heavy-
duty cord is used for D-
Y59 AB, Y69 AB , Y7P(V),
D-M9, M9V, D-
M9W, M9WV,
M9AL, M9AVL as
standard. No need to
suffix -61 to the end of
part number.

Specifications are the same as standard products with the exception of lead wire specifications.
Lead wire: For D-F8 type············ ø2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
For other model nos.··················· ø3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type. Lead wire diameter is changed from ø4 to ø3.4. In other series products,
it is common as standard product's specifications.

1330
2-2-47-D-UMASw.qxd 09.9.30 3:23 PM Page 12

Reed Auto Switches


General Purpose Type,
2-Color Indication Type

Reed Switch Variations


Auto switch
Type Function Electrical entry Auto switch model Page
mounting style

D-C73/C76/C80 1332
Grommet
D-B53/B54/B64 1333
Connector D-C73C/C80C 1334
Band D-A33/A34 1335
Terminal conduit
D-A33A/A34A 1336
General purpose

D-A44 1335
DIN terminal
D-A44A 1336
D-A72/A73/A80 1337
Grommet
Rail D-A72H/A73H/A76H/A80H 1338
Connector D-A73C/A80C 1339
Reed Auto Switch

Grommet D-A53/A54/A56/A64/A67 1340


Tie-rod Terminal conduit D-A33C/A34C
1341
DIN terminal D-A44C
D-A90/A93/A96∗
1342
D-A90V/A93V/A96V∗
Direct Grommet
D-Z73/Z76/Z80∗∗ 1343
D-E73A/E76A/E80A 1344
indication

Band Grommet D-B59W 1345


2-color

Rail Grommet D-A79W 1346


Tie-rod Grommet D-A59W 1347
Magnetic field

D-P79WSE 1348
resistance

Rod Grommet
D-P74 1349
resistant

Terminal conduit D-B30/31/35


Band 1351
Heat

Grommet D-B30J/31J/35J

∗ Auto switches with an asterisk (∗) can be mounted on a band (excluding D-A9쏔V), rail, tie-rod or square groove with an auto switch mounting bracket. Refer
to pages 1356, 1360, 1364, 1368 and 1369 for details.
∗∗ This auto switch can be mounted by tie-rod with using auto switch mounting bracket. For details, refer to page 1367.

D-쏔

1331
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1332

Reed Auto Switch


Band Mounting Style
D-C73/D-C76/D-C80
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-C7 (With indicator light)
Auto switch model D-C73 D-C76
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC
Max. load current and range (3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less 0.8 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-C8 (Without indicator light)
Auto switch model D-C80
Applicable load Relay, PLC, IC circuit
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Max. load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 cores
Auto Switch Internal Circuit (Brown, Black, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
D-C73 Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
LED Brown there is no problem in terms of contact output, when an output signal exceeds 1 mA or
OUT (+) more.
Resistor Contact Brown
Reed switch

protection
Zener box  Mass (g)
diode CD-P11
CD-P12
OUT (–)
Blue Blue
Auto switch model D-C73 D-C76 D-C80
0.5 9 10 9
Lead wire length
3 46 50 46
(m)
D-C76 5 76 — —

DC (+)
LED Brown
(+)
Resistor Dimensions (mm)
Reed switch

Load
Reverse OUT DC
current
prevention Black
diode
(–) 26 2
DC (–)
Blue 9
ø3.4
6.5

SMC
8

D-C80
Indicator light
D-C80 without indicator light
Reed switch

Contact OUT (±)


protection Brown 4.3
box 
CD-P11
OUT ( ) ±
CD-P12
11.5

Blue
8

ø3.5

9.5 Most sensitive position


Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life
may decrease. (Refer to page 1273 for contact
protection box.)

1332
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1333

Reed Auto Switch


Band Mounting Style
D-B53/D-B54/D-B64
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-B5 (With indicator light)
Auto switch model D-B53 D-B54
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC
Load current range (3) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-B6 (Without indicator light)
Auto switch model D-B64
Applicable load Relay, PLC
Load voltage 24 V AC
DC or less 100 VAC 200 VAC
Max. load current Max. 50 mA Max. 25 mA Max. 12.5 mA
Contact protection circuit Built-in
Internal resistance 25 Ω or less
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Auto Switch Internal Circuit Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
D-B53 Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
Reed switch LED
OUT (–) OUT (+)
Blue Resistor Brown Mass (g)

Zener diode
Auto switch model D-B53 D-B54 D-B64
0.5 22 22 22
Lead wire length
3 78 78 78
(m)
D-B54 5 126 126 —

Zener diode
Choke coil

OUT (–)
Resistor
OUT (+)
Dimensions (mm)
Blue Reed switch LED

Surge absorber 33
13
ø4
SMC
15
12

D-B64
Indicator light 6.5
Choke coil
D-B64 without
indicator light
OUT ( )  OUT (±) 
±
Blue Reed switch Brown
6.5
Surge absorber
14.3
9.5

Most sensitive
ø4.5 15.5 position D-

1333
2-2-47-D-UMASw.qxd 09.9.30 3:23 PM Page 13

Reed Auto Switch


Band Mounting Style
D-C73C/D-C80C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Connector PLC: Programmable Logic Controller


D-C73C (With indicator light)
Auto switch model D-C73C
Applicable load Relay, PLC
Load voltage 24 VDC
Load current range (4) 5 to 40 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-C80C (Without indicator light)
Auto switch model D-C80C
Caution Applicable load Relay, PLC

Precautions Load voltage 24 V AC


DC or less

1. Confirm that the connector is appropriately Maximum load current 50 mA


tightened. If tightened insufficiently, the Contact protection circuit None
waterproof performance will deteriorate. Internal resistance 1 Ω or less (Including lead wire length of 3 m)
2. For details, refer to page 1355.
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Auto Switch Internal Circuit Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Lead wire with connector may be shipped with switch.
D-C73C Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
Contact protection box there is no problem in terms of contact output, when an output signal exceeds 1 mA or
CD-P12
more.
LED Choke coil
Brown
OUT (+)
Resistor Brown Mass (g)
Reed switch

Zener
Zener diode diode

OUT (–) Auto switch model D-C73C D-C80C


Blue Blue 0.5 14 14
Lead wire length
3 53 53
(m)
5 83 83
D-C80C
Contact protection box
OUT (±) Dimensions
Reed switch

CD-P11 (mm)
CD-P12 Brown

±
OUT ( ) Lead wire with connector
Blue

Note 1) Operating load is an induction load.


Indicator light
Note 2) Wiring to the load is 5 m or longer.
Use the contact protection box in any of the D-C80C without
indicator light
above listed situations. The contact point life
may decrease. (Refer to page 1273 for contact
protection box.)

Most sensitive position

1334
P1277-P1354-E.qxd 08.10.3 2:43 PM Page 1335

Reed Auto Switch


Band Mounting Style
D-A33/D-A34/D-A44
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit: D-A3 PLC: Programmable Logic Controller


DIN terminal: D-A4 D-A3 (With indicator light) Terminal conduit
Auto switch model D-A33 D-A34
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC
Load current range (2) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-A44 (With indicator light) DIN terminal
Caution Auto switch model D-A44
Precautions Applicable load Relay, PLC
1. Use cable whose O.D. is within the size in Load voltage 24 VDC 100 VAC 200 VAC
the figure to maintain water resistant Load current range 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
performance.
2. After wiring, confirm that tightening gland Contact protection circuit Built-in
and all screws are tightened. Internal voltage drop 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Standard CE marking
Auto Switch Internal Circuit
Note 1) Refer to page 1272 for reed auto switch common specifications.
D-A33 Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
Reed switch LED
OUT (–) OUT (+)
Terminal no. 2 Resistor Terminal no. 1
Mass (g)
Zener diode

Auto switch model D-A33 D-A34 D-A44


Lead wire None 116 116 114

D-A34, D-A44

Choke coil
Reed switch LED
OUT (–)  Resistor OUT (+) 
Dimensions (mm)
Terminal no. 2 Terminal no. 1
Zener diode D-A3 D-A44
Surge absorber Tightening
gland Tightening
gland

G 1/2 G 1/2
Applicable cable O.D. ø6.8 to ø9.6 Applicable cable O.D. ø6.8 to ø11.5

Indicator light
Most sensitive position
Most sensitive position
D-

1335
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1336

Reed Auto Switch


Band Mounting Style
D-A33A/D-A34A/D-A44A
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit: D-A3A PLC: Programmable Logic Controller


DIN terminal: D-A44A D-A3A (With indicator light) Terminal conduit
Auto switch model D-A33A D-A34A
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC
Load current range (2) 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Caution Standard CE marking
Precautions D-A44A (With indicator light) DIN terminal
1. Use cable whose O.D. is within the size in Auto switch part model D-A44A
the figure to maintain water resistant Applicable load Relay, PLC
performance.
2. After wiring, confirm that tightening gland Load voltage 24 VDC 100 VAC 200 VAC
and all screws are tightened. Load current range 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Contact protection circuit Built-in
Auto Switch Internal Circuit Internal voltage drop 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
D-A33A Indicator light Red LED illuminates when turned ON.
Standard CE marking
Reed switch LED Note 1) Refer to page 1272 for reed auto switch common specifications.
OUT (–) OUT (+)
Terminal no. 2
Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
Resistor Terminal no. 1
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Zener diode more.

Mass (g)
D-A34A, D-A44A
Choke coil
Reed switch LED
Auto switch model D-A33A D-A34A D-A44A
OUT (–)  Resistor OUT (+) 
Lead wire None 112 112 110
Terminal no. 2 Terminal no. 1
Zener diode
Surge absorber

Dimensions (mm)

D-A3A D-A44
G 1/2
(Applicable cable O.D. Tightening gland
ø6.8 to ø9.6)

Tightening gland G 1/2


(Applicable cable O.D.
ø6.8 to ø11.5)

Most sensitive position Most sensitive position

1336
Reed Auto Switch
Rail Mounting Style
D-A72/D-A73/D-A80
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


Electrical entry: Perpendicular D-A7 (With indicator light)
Auto switch model D-A72 D-A73
Applicable load Relay, PLC Relay, PLC
Load voltage 200 VAC 24 VDC 100 VAC
Load current range (3) 5 to 10 mA 5 to 40 mA 5 to 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-A8 (Without indicator light)
Auto switch model D-A80
Applicable load Relay, IC circuit, PLC
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Maximum load current 50 mA 40 mA 20 mA
Contact protection circuit None
Auto Switch Internal Circuit Internal resistance 1 Ω or less (Including lead wire length of 3 m)
D-A72 Standard CE marking
Contact protection box • Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
CD-P11 Note 1) Refer to page 1272 for reed auto switch common specifications.
LED Brown Note 2) Refer to page 1272 for lead wire lengths.
OUT Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
Resistor Choke
coil Brown
indicator light will not be possible where the output signal is less than 2.5 mA. However,
Reed switch

Zener diode ~ there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Surge
absorber more.
OUT
Blue Blue
Mass (g)

D-A73 Auto switch model D-A72 D-A73 D-A80


0.5 10 10 10
Lead wire length
LED 3 47 47 47
Brown (m)
OUT (+)
Resistor Contact
Brown
5 — 77 —
protection
Reed switch

Zener diode box


CD-P11 ~
CD-P12
OUT (–)
Blue Blue Dimensions (mm)

8
ø3.2
Indicator light
D-A80
D-A80 without
15 (14)

indicator light
4

Contact OUT (±)


Reed switch

7 (6)

protection Brown
23 (22)
11.5 (11.7)

box ~
CD-P11 ±
CD-P12 OUT ( )
Blue ø3.4
3

Note 1) Operating load is an induction load.


6 (6.2)

Note 2) Wiring to the load is 5 m or longer. 9 (8.5) Most sensitive position


Note 3) Load voltage is 100 VAC or 200 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life ( ) values for D-A72 D-쏔
may decrease. Especially in the case of
D-A72, be sure to use the contact protection
box. (Refer to page 1273 for contact protection
box.)

1337 a
Reed Auto Switch
Rail Mounting Style
D-A7쏔H/D-A80H
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


Electrical entry: In-line D-A7쏔H (With indicator light)
Auto switch model D-A72H D-A73H D-A76H
Applicable load Relay, PLC Relay, PLC IC circuit
Load voltage 200 VAC 24 VDC 100 VAC 4 to 8 VDC
Max. load current/Load current range(3) 5 to 10 mA 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less 0.8 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
Auto Switch Internal Circuit D-A80H (Without indicator light)
D-A72H Auto switch model D-A80H
Applicable load Relay, IC circuit, PLC
Contact protection box
AC AC AC
CD-P11 Load voltage 24 V DC or less 48 V DC 100 V DC
LED Brown
OUT Maximum load current 50 mA 40 mA 20 mA
Resistor Choke
Brown
coil Contact protection circuit None
Reed switch

Zener diode ~
Surge Internal resistance 1 Ω or less (Including lead wire length of 3 m)
absorber
OUT Standard CE marking
Blue Blue
• Lead wires — Oilproof heavy-duty vinyl cord, 0.2 mm2, 2 cores (Brown, Blue), 3 cores (Brown,
Black, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
D-A73H Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
LED Brown more.
OUT (+)
Resistor Contact
Brown
protection
Reed switch

Zener diode box


CD-P11 ~ Mass (g)
CD-P12
OUT (–)
Blue Blue
Auto switch model D-A72H D-A73H D-A76H D-A80H
0.5 10 10 11 10
Lead wire length
3 47 47 52 47
D-A76H (m)
5 — 77 — —
DC (+)
LED Brown
(+)
Resistor
Reed switch

Load
Reverse OUT DC power
current
prevention
Black supply
Dimensions (mm)
diode
(–)
DC (–) D-A7쏔H, D-A80H
Blue
8
ø3.2

D-A80H
4
15

SMC
7
Reed switch

Contact OUT (±)


protection Brown
box ~ Indicator light
CD-P11
CD-P12 OUT ( )
± D-A80H without
Blue indicator light

22 2
Note 1) Operating load is an induction load.
ø3.4
3.3

Note 2) Wiring to the load is more than 5 m.


Note 3) Load voltage is 100 VAC or 200 VAC.
10.2

Use the contact protection box in any of the


6.2

above listed situations. The contact point life


may decrease. Especially in the case of
D-A72H, be sure to use the contact 8.5 Most sensitive position
protection box. (Refer to page 1273 for contact
protection box.)

a 1338
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1339

Reed Auto Switch


Rail Mounting Style
D-A73C/D-A80C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Connector PLC: Programmable Logic Controller


D-A73C (With indicator light)
Auto switch model D-A73C
Applicable load Relay, PLC
Load voltage 24 VDC
Load current range (4) 5 to 40 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-A80C (Without indicator light)
Caution Auto switch model D-A80C
Precautions Applicable load Relay, IC circuit, PLC
AC
1. Confirm that the connector is appropriately Load voltage 24 V DC
tightened. If tightened insufficiently, the Maximum load current 50 mA
waterproof performance will deteriorate.
Contact protection circuit None
2. Refer to page 1355 for the details.
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Auto Switch Internal Circuit Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
D-A73C Note 3) Lead wire with connector may be shipped with the auto switch.
Contact protection box Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
CD-P12 indicator light will not be possible where the output signal is less than 2.5 mA. However,
LED Choke coil
Brown there is no problem in terms of contact output, when an output signal exceeds 1 mA or
OUT (+)
Resistor Brown more.
Reed switch

Zener
Zener diode diode

OUT (–)
Mass (g)
Blue Blue

Auto switch model D-A73C D-A80C


0.5 12 12
D-A80C Lead wire length
3 54 54
(m)
5 84 84

Contact OUT (±)


Reed switch

protection Brown
box
CD-P11
~
CD-P12 ±
OUT ( )
Blue
Dimensions (mm)

Note 1) Operating load is an induction load.


Note 2) Wiring to the load is 5 m or longer.
Use the contact protection box in any of the
Lead wire
above listed situations. The contact point life with connector
may decrease. (Refer to page 1273 for contact
protection box.) Indicator light
D-A80C without
indicator light

Most sensitive position D-

1339
Reed Auto Switch
Tie-rod Mounting Style
D-A5쏔/D-A6쏔
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-A5 (With indicator light)
Auto switch model D-A53 D-A54 D-A56
Applicable load PLC Relay, PLC IC circuit
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC 4 to 8 VDC
Maximum load (3)
5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA 20 mA
current and range
Contact protection circuit None Built-in None
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA) 0.8 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-A6 (Without indicator light)
Auto switch model D-A64 D-A67
Applicable load Relay, PLC PLC/IC circuit
AC
Load voltage 24 V DC or less 100 VAC 200 VAC Max. 24 VDC
Maximum load current 50 mA 25 mA 12.5 mA 30 mA
Contact protection circuit Built-in None
1 Ω or less
Auto Switch Internal Circuit Internal resistance 25 Ω or less (Including lead wire
length of 3 m)
D-A53 Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), or 0.2 mm2, 3
Reed switch LED cores (Brown, Black, Blue), 0.5 m
OUT (–) OUT (+) Note 1) Refer to page 1272 for reed auto switch common specifications.
Blue Resistor Brown Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
Zener diode indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
D-A54
Zener diode Mass (g)
Choke coil
Resistor
OUT (–) 앑 OUT (+) 앑
Blue Reed Brown
Auto switch model D-A53 D-A54 D-A56 D-A64 D-A67
LED
switch
0.5 24 24 24
Lead wire length
Surge absorber
(m) 3 48 48 48
5 96 — —
D-A56
DC (+)
LED Brown
Resistor
(+) Dimensions (mm)
Reed switch

Load
Reverse OUT DC power supply
current Black
prevention 6 14
diode
(–)
DC (–) 6
4.5

Blue
5

D-A64
22
12

Choke coil
Indicator light 33 12
OUT ( ) 앑
±
OUT (±) 앑
Blue Reed switch Brown D-A64/A67 without
indicator light
Surge absorber
ø4

D-A67
16
11

Reed switch
± 16 Most sensitive position
OUT ( ) OUT (±)
Blue
Brown

a 1340
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1341

Reed Auto Switch


Tie-rod Mounting Style
D-A33C/D-A34C/D-A44C
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Terminal conduit:D-A3C PLC: Programmable Logic Controller


DIN terminal: D-A44C D-A3C (With indicator light) Terminal conduit
Auto switch model D-A33C D-A34C
Applicable load PLC Relay, PLC
Load voltage 24 VDC 24 VDC 100 VAC 200 VAC
(2) 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
Load current range 5 to 50 mA
Contact protection circuit None Built-in
Internal voltage drop 2.4 V or less 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-A44C (With indicator light) DIN terminal
Caution Auto switch model D-A44C
Precautions Applicable load Relay, PLC
1. Use cable whose O.D. is within the size in Load voltage 24 VDC 100 VAC 200 VAC
the figure to maintain water resistant
Load current range (2) 5 to 50 mA 5 to 25 mA 5 to 12.5 mA
performance.
2. After wiring, confirm that tightening gland Contact protection circuit Built-in
and all screws are tightened. Internal voltage drop 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA)
Indicator light Red LED illuminates when turned ON.
Auto Switch Internal Circuit CE marking
Standard
D-A33C Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
Reed switch LED light will not be possible where the output signal is less than 2.5 mA. However, there is no
OUT (–) OUT (+) problem in terms of contact output, when an output signal exceeds 1 mA or more.
Terminal no. 2 Resistor Terminal no. 1
Mass (g)

Zener diode
Auto switch model D-A33C D-A34C D-A44C
40 162 162 160
50 166 166 164
D-A34C, D-A44C Applicable bore size
(mm) 63 184 184 182
Choke coil 80 210 210 208
Reed switch LED
100 232 232 230
OUT (–)  Resistor OUT (+) 
Terminal no. 2
Zener diode
Terminal no. 1 Dimensions (mm)

Surge absorber
Applicable bore
Auto switch model C HW H H' T T' Z
size (mm)
D-A3C-4, D-A44C-4 40 44 69 58 (67.5) 50.5 (60) 7.5 6.5
M5 x 0.8 x 16
D-A3C-5, D-A44C-5 50 52 77 59 (68.5) 51.5 (61) 8.5 6.5
D-A3C-6, D-A44C-6 63 64 91 61.5 (71) 53 (62.5) 10.5 7.5 M5 x 0.8 x 20
D-A3C-8, D-A44C-8 80 78 107 65 (74.5) 54.5 (64) 12.5 9.5
M5 x 0.8 x 25
D-A3C-10, D-A44C-10 100 92 121 68 (77.5) 57.5 (67) 15.5 9.5
Dimensions ∗ ( ): Denotes the values of D-A44C (mm)

D-A3C 2 x M5 x 0.8 x 12 D-A44C


Hexagon socket head cap bolt 2 x M5 x 0.8 x 12
Tightening gland Hexagon socket head cap bolt
Tightening gland

G 1/2 4xZ G 1/2


4xZ
Hexagon socket (Applicable cable O.D. Hexagon socket (Applicable cable O.D.
head cap bolt ø6.8 to ø9.6) head cap bolt ø6.8 to ø11.5)

D-

Indicator light
Most sensitive position
Most sensitive position

1341
Reed Auto Switch
Direct Mounting Style
D-A90(V)/D-A93(V)/D-A96(V)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.
Grommet PLC: Programmable Logic Controller
D-A90, D-A90V (Without indicator light)
Auto switch model D-A90, D-A90V
Applicable load IC circuit, Relay, PLC
Load voltage 24 V AC
DC or less 48 V AC
DC or less 100 V AC
DC or less

Maximum load current 50 mA 40 mA 20 mA


Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
Standard CE marking
D-A93, D-A93V, D-A96, D-A96V (With indicator light)
Auto switch model D-A93, D-A93V D-A96, D-A96V
Caution Applicable load Relay, PLC IC circuit
Precautions Load voltage 24 VDC 100 VAC 4 to 8 VDC
Fix the auto switch with the existing screw
installed on the auto switch body. The auto Load current range and 5 to 40 mA 5 to 20 mA 20 mA
switch may be damaged if a screw other Maximum load current (3)
than the one supplied is used. Contact protection circuit None
D-A93: 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)
Internal voltage drop 0.8 V or less
D-A93V: 2.7 V or less
Indicator light Red LED illuminates when turned ON.

Auto Switch Internal Circuit Standard CE marking


• Lead wires
D-A90(V)/D-A93(V)—Oilproof heavy-duty vinyl cord, ø2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m
D-A90, A90V D-A96(V)—Oilproof heavy-duty vinyl cord, ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Reed switch

Contact OUT (±)


protection Brown
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator
box light will not be possible where the output signal is less than 2.5 mA. However, there is no
앑 problem in terms of contact output, when an output signal exceeds 1 mA or more.
CD-P11
CD-P12 OUT (±)
Blue Mass
(g)
Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V
D-A93, A93V 0.5 6 6 6 6 8 8
Lead wire length
LED Brown
OUT (+) (m) 3 30 30 30 30 41 41
Contact
Resistor Brown
protection
Dimensions
Reed switch

box (mm)
Zener diode 앑
CD-P11
CD-P12 D-A90/D-A93/D-A96
OUT (–)
4.5

Blue 2.8 2
ø2.7

Blue

4
24.5
D-A96, A96V Indicator light
M2.5 x 4 L (22)
DC (+)
LED Brown D-A90 without indicator light
Slotted set screw
(+)
Resistor
Load
Reed switch

Reverse OUT DC
current Black power supply Most sensitive
prevention 10 position
diode ( ): dimensions for D-A96.
(–) D-A90V/D-A93V/D-A96V
DC (–)
Blue

Note 1) Operating load is an induction load.


Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC. 22
Use the contact protection box in any of the
2 6
above listed situations. The contact point life M2.5 x 4 L
may decrease. (Refer to page 1273 for contact Slotted set screw
protection box.)

ø2.7 Indicator light


D-A90V without indicator light
4.5
9.1

5.1

10 Most sensitive position

b 1342
Reed Auto Switch
Direct Mounting Style
D-Z73/D-Z76/D-Z80
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-Z7 (With indicator light)
Auto switch model D-Z73 D-Z76
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC
Max. load current and load current range(3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less (to 20 mA)/3 V or less (to 40 mA) 0.8 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-Z8 (Without indicator light)
Auto switch model D-Z80
Applicable load Relay, PLC, IC circuit
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Maximum load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking
• Lead wires
D-Z73/D-Z80—Oilproof heavy-duty vinyl cord, ø2.7, 0.18 mm2, 2 cores (Brown, Blue), 0.5 m
Auto Switch Internal Circuit D-Z76—Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
D-Z73 Note 2) Refer to page 1272 for lead wire lengths.
LED Brown
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
OUT (+) indicator light will not be possible where the output signal is less than 2.5 mA. However,
Resistor Contact Brown
protection there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Reed switch

Zener diode box more.


CD-P11 앑
CD-P12
OUT (–)
Blue Blue Mass (g)

D-Z76
Auto switch model D-Z73 D-Z76 D-Z80
DC (+)
LED Brown 0.5 7 10 7
(+) Lead wire length
Resistor
(m) 3 31 55 31
Load
Reed switch

Reverse OUT DC power supply 5 50 — —


current Black
prevention
diode
(–)
DC (–)
Blue
Dimensions (mm)

D-Z80 D-Z73, Z80 D-Z76


M2.5 x 4L
Slotted set screw
Reed switch

Contact OUT(±)
M2.5 x 4L 27.6 1.5
protection Brown
box Slotted set screw 30.5
앑 2.5
CD-P11 2.3
±
CD-P12 OUT ( )
Blue
6.2
6.2

Indicator light Indicator light


D-Z80 without indicator light
Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer.
5.7
5.5

Note 3) Load voltage is 100 VAC.


Use the contact protection box in any of the
ø2.7

Most sensitive
ø3.4

Most sensitive
above listed situations. The contact point life 12.5 position 12.5 position
may decrease. (Refer to page 1273 for contact
protection box.) D-쏔

1343 b
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1344

Reed Auto Switch


Direct Mounting Style
D-E73A/D-E76A/D-E80A
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-E7A (With indicator light)
Auto switch model D-E73A D-E76A
Applicable load Relay, PLC IC circuit
Load voltage 24 VDC 100 VAC 4 to 8 VDC
Max. load current and load current range(3) 5 to 40 mA 5 to 20 mA 20 mA
Contact protection circuit None
Internal voltage drop 2.4 V or less 0.8 V or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
D-E80A (Without indicator light)
Auto switch model D-E80A
Applicable load Relay, PLC, IC circuit
AC AC AC
Load voltage 24 V DC or less 48 V DC 100 V DC
Maximum load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (Including lead wire length of 3 m)
Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 cores
(Brown, Black, Blue), 0.5 m
Auto Switch Internal Circuit Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
D-E73A Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
LED Brown
OUT (+) there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Resistor Contact Brown more.
protection
Reed switch

Zener diode box 


CD-P11
CD-P12
Mass (g)
OUT (–)
Blue Blue
Auto switch model D-E73A D-E76A D-E80A
D-E76A 0.5 10 11 10
Lead wire length
DC (+) 3 47 55 47
LED Brown (m)
(+) 5 — — —
Resistor
Reed switch

Load
Reverse OUT DC power supply
current Black
prevention
diode
DC (–)
(–) Dimensions (mm)
Blue

8 8
D-E80A

OUT (±)
Reed switch

Contact
protection Brown
box 
CD-P11 Indicator light
OUT ( ) ±
CD-P12 D-E80A without indicator light
Blue

22

Note 1) Operating load is an induction load. Most sensitive position 8.5


0.5 6 0.5
0.5

Note 2) Wiring to the load is 5 m or longer.


Note 3) Load voltage is 100 VAC.
ø3.4

Use the contact protection box in any of the


2.4

above listed situations. The contact point life


12.5

may decrease. (Refer to page 1273 for contact


SMC D-E73A
protection box.)
2.7

3
6

6.4

1344
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 27

2-Color Indication Type Reed Auto Switch


Band Mounting Style
D-B59W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-B59W (With indicator light)


be determined by the color of Auto switch model D-B59W
the light. Applicable load Relay, PLC
(Red → Green ← Red) Load voltage 24 VDC
Load current range(3) 5 to 40 mA
Contact protection circuit Built-in
Internal voltage drop 4 V or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Auto Switch Internal Circuit more.

D-B59W Mass (g)


Choke coil
OUT (+)
Brown
Reed switch Auto switch model D-B59W
Zener diode
0.5 20
Main circuit

Lead wire length


of switch

(m) 3 76
LED
5 —
OUT (–)
Blue

Indicator light/Display method


Dimensions (mm)

Operating range
33
Indication 13
Red Green Red
ø4
15
12

Proper operating range

Indicator light 6.5

6.5
0.5
14.3

9.5

ø4.5 12.6 Most sensitive position

D-쏔

1345
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 28

2-Color Indication Type Reed Auto Switch


Rail Mounting Style
D-A79W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-A79W (With indicator light)


be determined by the color of Auto switch model D-A79W
the light. Applicable load Relay, PLC
(Red → Green ← Red) Load voltage 24 VDC
Load current range (3) 5 to 40 mA
Contact protection circuit None
Internal voltage drop 4 V or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.
Auto Switch Internal Circuit
D-A79W Mass (g)

OUT (+)
Brown Auto switch model D-A79W
Reed switch
Reverse flow
prevent diode Lead wire length 0.5 11
Main circuit

(m)
of switch

3 53
LED

OUT (–)
Blue

Dimensions (mm)
Indicator light/Display method

8 ø3.2
Operating range
Indicator light
Indication
4
15

Red Green Red


7

23.5
Proper operating range
1.8

Note 1) Operating load is an induction load. ø3.4


Note 2) Wiring to the load is 5 m or longer.
Use the contact protection box in any of the
3

above listed situations. The contact point life


14

may decrease. (Refer to page 1273 for contact


6.2

protection box.)

11.5 Most sensitive position

1346
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 29

2-Color Indication Type Reed Auto Switch


Tie-rod Mounting Style
D-A59W
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can D-A59W (With indicator light)


be determined by the color of Auto switch model D-A59W
the light. Applicable load Relay, PLC
(Red → Green ← Red) Load voltage 24 VDC
Load current range(3) 5 to 40 mA
Contact protection circuit Built-in
Internal voltage drop 4 V or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.

Standard CE marking
• Lead wires — Oilproof heavy-duty vinyl cord, ø4, 0.3 mm2, 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Auto Switch Internal Circuit more.

D-A59W Mass (g)


Choke coil
OUT (+)
Brown
Reed switch Auto switch model D-A59W
Zener diode
Lead wire length 0.5 25
Main circuit
of switch

(m) 3 80
LED

OUT (–)
Blue

Dimensions (mm)
Indicator light/Display method

6 14
Operating range
7 ø4.5
4.9

Indication
Green Red
ø4
23
13

Proper operating range

Indicator light
33 12
0.5
16
11

12 Most sensitive position

D-쏔

1347
2-2-47-D-UMASw.qxd 09.11.11 2:53 PM Page 30

Magnetic Field Resistant 2-Color Indication Type


Reed Auto Switch
D-P79WSE
(Electrical Entry: Pre-wired connector)
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller

The proper operating range can Auto switch model D-P79WSE


be determined by the color of Applicable load PLC
the light. Load voltage 24 VDC
(Red → Green ← Red) Load current range 8 to 20 mA
Contact protection circuit Yes
Internal voltage drop 6 V or less
Operating range .......... Red LED illuminates.
Indicator light
Proper operating range .......... Green LED illuminates.
Standard CE marking
• Lead wires — Oilproof, fire resistant heavy-duty vinyl cord, ø6, 0.75 mm2, 2 cores, 300 mm
Note 1) Refer to page 1272 for reed auto switch common specifications.

Caution
Precautions Mass (g)

Cylinder with a strong integrated magnet


must be used. D-P79WSE
Auto switch model
100

Auto Switch Internal Circuit


D-P79WSE
Choke coil
NO.1 (+)
Dimensions (mm)

Reed switch D-P79WSE


Indicator light Connector size M12
Light circuit

Zener diode
Heat shrink tube Note)
MADE IN JAPAN

LED
D-P79W

SMC
14.6

ø14
DC24V

NO.4 (–)

Indicator light/Display method 32 5 300 44

ON Soft resin mold surface


Operating (Mounting surface for the
switch mounting bracket side) 2 x 2 x ø6
range OFF
Counterbore depth 2.4
Indication
2 x ø3.4 through
Red Green Red
5
Proper operating
ø6

range
4
20

2 1
16 Most sensitive position
3 4

Note) D-P79WSE = “SE 1 4-”


Connector pin

Caution
Please be careful of the mounting direction.
The soft resin mold surface must be directed to the switch mounting bracket side.

1348
2-2-47-D-UMASw.qxd 09.9.30 3:23 PM Page 17

Magnetic Field Resistant Reed Auto Switch


D-P74L/D-P74Z
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-P74L/Z (With indicator light)
Auto switch model D-P74L D-P74Z
Electrical entry Grommet
Application Relay, PLC
Load voltage 24 VDC 100 VAC
Max. load voltage/Load current range 5 to 40 mA 5 to 20 mA
Contact protection circuit Built-in
Internal voltage drop (internal resistance) 2.4 V or less
Leakage current 0

Indicator light Red LED illuminates when turned ON.

Caution Standard CE marking

Precautions • Lead wires — Oilproof, fire resistant heavy-duty vinyl cord, ø6.8, 0.75 mm2, 2 cores (Brown, Blue),
D-P74L: 3 m, D-P74Z: 5 m
Cylinder with a strong integrated magnet Note 1) Refer to page 1272 for reed auto switch common specifications.
must be used. Note 2) Refer to page 1272 for lead wire lengths.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
Auto Switch Internal Circuit more.

D-P74L, P74Z
Surge absorber
Mass (g)

Choke Resistor Reed


coil switch
LED
Auto switch model D-P74
Zener diode Lead wire length 3 189
(m) 5 320
Brown Blue
(+) (–)

Dimensions (mm)

Indicator light
13.6

SMC

32 5

2 x 2 x ø6
Counterbore depth 2.4
2 x ø3.4 through
5
ø6.8
4
20

16 Most sensitive position

1349
2-2-47-D-UMASw.qxd 09.9.30 3:23 PM Page 18

Magnetic Field Resistant Reed Auto Switch


D-P74-376
Refer to SMC website for the details of
the products conforming to the
Auto Switch Specifications international standards.

Grommet PLC: Programmable Logic Controller


D-P74-376 (With indicator light)
Auto switch model D-P74-376
Electrical entry Grommet
Application Relay, PLC
Load voltage 24 VDC
Max. load current/Load current range 5 to 20 mA
Contact protection circuit Built-in
Internal voltage drop (internal resistance) 2 V or less
Leakage current 0
Operating time 1.2 ms
Indicator light Red LED illuminates when turned ON.

Caution Standard CE marking

Precautions • Lead wires — Oilproof, fire resistant heavy-duty vinyl cord, ø6, 0.5 mm2, 2 cores, 0.5 m
Note 1) Refer to page 1272 for reed auto switch common specifications.
Cylinder with a strong integrated magnet Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
must be used. indicator light will not be possible where the output signal is less than 2.5 mA. However,
there is no problem in terms of contact output, when an output signal exceeds 1 mA or
more.

Auto Switch Internal Circuit


Mass (g)
D-P74-376
Surge absorber
D-P74-376
Auto switch model
Choke LED Reed 60
coil switch

LED

NO.3 (±) NO.4 (±) Dimensions (mm)

Indicator light Connector size M12


2 1

3 4
13.6

ø14
SMC

Connector pin

32 5 500 44.5

2 x 2 x ø6
Counterbore depth 2.4
2 x ø3.4 through
5
ø6
4
20

16 Most sensitive position

1350
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1351

Heat Resistant Reed Auto Switch


D-B30(J)/31(J)/35(J)
Refer to SMC website for the details of
the products conforming to the
Can be used outdoors or under Auto Switch Specifications international standards.
high temperature (Max. 120°C). PLC: Programmable Logic Controller
Wide operating range (double Auto switch model D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J
that of other SMC products) Terminal Terminal Terminal
enables stable position Electrical entry
conduit
Grommet
conduit
Grommet
conduit
Grommet
detection. Operating voltage 24 VDC / 100 VAC 100 VAC 24 VDC
Operating current range 5 to 30 mADC / 5 to 20 mAAC 5 to 20 mAAC 5 to 30 mADC
Internal voltage drop 2.5 V or less 2.5 V or less 2.0 V or less
Indicator light Without indicator light Neon bulb lights up when OFF Red LED lights up when OFF
Applicable load PLC (Programmable Logic Controller)
Shock resistance 300 m/s2
Leakage current 0.1 mA or less 1 mA or less 1 mA or less
High temperature environment such
as places around ignited gas outlet Lead wire — 0.5 mNote 1) — 0.5 mNote 1) — 0.5 mNote 1)
or furnace Terminal conduit : IEC60529 IP64
Enclosure
Outdoor plants and environment Grommet : IEC60529 IP67
with high temperature and humidity Withstand voltage 1500 VAC for 1 minute (between case and terminals or lead wires)
Environment for steam cleaning or Insulation resistance 50 MΩ or larger between case (ground) and lead wires (terminals)
high temperature sterilization Operating temperature range –10C to 120C
Applications requiring wide Standard CE marking
operating range such as clamping of
Note 1) Lead wire specifications: Outside diameter 6 mm; Fluororubber sheath; HBO-FTCF; 0.5 mm2 x 2
elastic work pieces
Use of metal case and heat resistant
materials.
The construction prevents influence of
external environment by sealing the auto
switch internal parts to improve heat Mass (g)
resistance.
The wide operating range allows easy
position setting and reduces influence of the Auto switch model D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J
work piece position changes. 0.5 190 250 190 250 190 250
Lead wire
Auto Switch Internal Circuit length 3 — 368 — 368 — 368
(m) 5
D-B30 — 462 — 462 — 462

Contacts protection resistance


Brown Blue
(Terminal 1) Contacts (Terminal 2)
(Magnetism detection)
Lead wire length
In case of the grommet type (J type), the lead wire length is 0.5 m.
(No lead wire is attached to the terminal conduit type.)
D-B31 Manufacture of 3 m and 5 m types is also possible. Please consult SMC for these types.

Contacts protection resistance


Brown Blue
(Terminal 1) Contacts (Terminal 2)
(Magnetism detection)
Neon bulb

Current limiting
resistance

D-B35
Contacts protection resistance
Brown Blue
(Terminal 1) Contacts (Terminal 2)
(Magnetism detection)
Light emitting diode (LED)
D-

Current limiting
resistance

Protection diode

1351
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1352

Heat Resistant Reed Auto Switch Series D-B3

Dimensions (mm)

Terminal conduit type D-B3 Terminal conduit type D-B3J

42 42
G 1/2 500

59
38
59
38

ø6
41.5 41.5
69 85
35

35
8

42

8
59
12

85

∗ Recommended minimum bending radius for lead wire RT : 25 mm or more


Terminal part 120°C : 50 mm or more

Dimensions for Cylinder Mounting


59
Hs dimensions (mm)
Cylinder model
Bore size
CDA2 MDB
40 mm 58.5 57.5
Hs

50 mm 64 63
63 mm 71 69.5
80 mm 79.5 78.5
100 mm 90 89

Mounting cylinder part no.

CDA2 B 50 – 200 – B31J S – X1184


With built-in special magnet

Cylinder Number of auto switches


stroke Symbol Description
Nil 2 pcs.
S 1 pc.
Cylinder bore size
Auto switch type
Symbol Description
Mounting Nil Without auto switch
B30 D-B30
B30J D-B30J
Cylinder model B31 D-B31
Symbol Description B31J D-B31J
CDA2 Series CDA2 (Bore size 40 to 100) B35 D-B35
MDB Series MDB (Bore size 40 to 100) B35J D-B35J

∗ Please consult SMC in case the switch is to be mounted on models other than applicable cylinders.
1352
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1353

Series D-B3
Specific Product Precautions
Be sure to read before handling.
Refer to front matters 54 and 55 for Safety Instructions and pages 8 to 11 for Auto
Switch Precautions.

Caution
1. Use the reed switch within the operating 5. Keep the lead wire length as short as possi-
range. ble.
Take precautions about the ambient temperature because using If a long lead wire is used because of the conditions of the plant or
the reed switch beyond the operating range may affect its internal equipment where the switch is installed, malfunction in the reed
electronic parts and sealing construction, causing abnormalities to switch reset operation may occur due to premature damage to the
the service life of the contact, as well as operation and waterproof contact surface caused by the inrush current resulting from the line
performance of the switch. flotation capacity and influence of the electric field created by the
Also, the maximum temperature of the environment where the power line near the wiring.
switch is used must be fully understood before operation is started Therefore, the maximum wiring length should be kept at 100 m or
because the temperature of the environment where the auto less.
switch is installed may experience some changes after operation is Avoid wiring in proximity with the power line. Also, if the length of
started due to factors other than air temperature such as influence wiring in use is extremely long (30 m or longer), schedule
of radiation heat from the heat source, air circulation or heat replacement in periodical maintenance.
conduction. The basic guidelines for replacement are a total wiring length of
100 m between the load and the auto switch and 1 million cycles
of operation (at 120°C , 100VAC PLC load).
2. Take precautions about the environment
where the auto switch is installed.
If conditions (water splashes, time, temperature) beyond the 6. Install the auto switch at the center of the
normal ranges can be applied to the auto switch, use the auto operating range.
switch in an environment where it will not be directly exposed to The operation range of the auto switch is set at approximately
water splashes at a high temperature by installing a cover to double that of the standard type in consideration of the mounting
protect the entire auto switch, as long as it is possible. The error when the detection position is set. However, this range is
grommet type auto switch has a construction that will protect its subject to change with the temperature. Although the variation in
internal parts against water splashes at the normal temperature. the operating range differs with the cylinder on which the auto
However, if the conditions (water splashes, time, temperature) switch is mounted, a temperature change of 100°C will roughly
exceed the normal ranges, they may adversely affect the auto result in the maximum of 20% reduction in the overall operation
switch internal insulation performance. range.
Also, confirm the applicability of the auto switch in the environment (Approximately 2 mm variation at the position where the auto
because extreme heat cycles or a long-term high humidity may switch usually turns on )
cause functional deterioration of the auto switch protection Therefore, install the auto switch at the center of the operating
construction. range (stable range), while understanding the possible change in
In principle, the terminal conduit type must be used in an the operating range and considering the stability of the auto switch
environment with no exposure to humidity or water because at operation.
high temperatures, it may become impossible to achieve sufficient (Avoid installation of the auto switch at the boundary where the
waterproof effect due to deformation of lead wire sealant auto switch turns on or off.)
depending on the heat resistance of the lead wire and cable
clamp. 7. Selection of applicable cylinders
The auto switch should be mounted on special cylinders (Series -
3. Visibility of an indicator light X1184) because it is operated by magnets using heat resistant
Because the auto switch uses light emitting diodes and neon bulbs material.
for display, continuous operation at a high temperature may cause Consult SMC in advance for special applications in which
changes in characteristics of the entire display circuit. Also, the conventional cylinder cannot be used because, depending on the
transparency of the display window on the body may change operating environment, it is possible that special measures should
depending on the characteristics of the resin. be taken or even the cylinder cannot be adapted.
Because of the above factors, lighting under high temperature may
become dark, causing decline of visibility. 8. Maintenance
However, there could be no problem in output of the signal itself After the auto switch is installed under high temperature, apply
and its safety owing to adoption of the OFF-state lighting system. additonal tightening peiodically to the auto switch mounting band.
The rubber lining of the auto switch mounting band may need
4. Take precautions about leakage current. some time to adapt to the environment because of temperature
According to the heat resistant characteristics of its parts, the auto chages in the installation environment. Perform additoinal
switch adopts the OFF-state lighting system (the indicator light tightening at a tightening torque of 2 to 3m⋅N while carefully
lights up when the reed switch contact is open and goes off when applying equal torque to both lifting screws.
the reed switch contact is closed).
Since the current for indication lighting is running when the auto 9. Product upgrades
switch is off, confirm the allowable leakage current of PLC etc. The product is subject to change without prior notice due to
before selecting the model. upgrades.
If the leakage current of the indicator light becomes a problem for
the PLC operation, select a model without an indicator light. D-

1353
P1277-P1354-E.qxd 08.10.3 2:44 PM Page 1354

1354
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1355

Technical Data 1:
Plug-in Connector Assembly/
How to Use DIN Terminal
Plug-in Connector Assembly How to Use DIN Terminal: D-A44/A44A/A44C
D-A73C/A80C, D-J79C Connection procedure
1. Loosen the set screw and pull out the connector from the pin plug.
D-C73C/C80C, D-H7C 2. Be sure to remove the set screw first and then insert a screwdriver into a
recessed groove under the terminal block to separate the terminal cover
from the terminal block.
3. Follow the procedures and connect wires securely to specified terminals.
4. In standard cases, crimp-style terminals are used to connect wires.
Please select proper crimp-style terminals so that the wire can be
properly connected to terminal fittings.
Locking ring
How to connect
AC:
Sleeve Connect to terminal no. 1 and no. 2
DC:
Connector Connect (+) to no. 1 terminal and (–) to no. 2 terminal.

Fixing screw
Tightening gland

With the convex port of the connector, insert the connector into the auto
switch into the sleeve. Screw the locking ring onto the switch.
(Do not tighten with pliers.) Gland washer
Gland gasket
Terminal cover
Terminal block
Terminal thread

Terminal gasket

How to change position of electrical entry


After separating the terminal block from the terminal cover, change the
position of the terminal cover to any desired direction (4 directions at every
90°) to change the position of electrical entry.

Caution
When plugging a connector in the pin plug or pulling it out, hold a connector
perpendicularly as much as possible, not to slant it.
Applicable cable (Heavy-duty cord)
Applicable to cable O.D. of ø6.8 to ø11.5.
Applicable crimp-style terminal
1.25Y-3L, 1.25-3.5S, 1.25-4M

D-

1355
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1356

Technical Data 2:
How to Mount and Move the Auto Switch

Mounting Bracket Band Mounting Style


<Applicable auto switch> Caution
Solid state ······ D-M9N, D-M9P, D-M9B
1. Tighten the screw under the specified torque when mounting auto switch.
D-M9NW, D-M9PW, D-M9BW 2. Set the auto switch mounting band perpendicularly to cylinder tube.
Reed ··············· D-A90, A93, A96
How to Mount and Move the Auto Switch
Mounting the Auto Switch
1. Attach the switch bracket to the switch holder.
(Fit the convex part of the switch bracket over the concave Mounting correctly Mounting incorrectly
part of the holder.)
2. Mount the auto switch mounting band to the cylinder tube.
3. Set the switch holder between the reinforcing plates of the
band which is already attached to the cylinder.
4. Insert the auto switch mounting screw in the hole of the Aporox. 10 to 15°
reinforcing plate through the switch holder, and thread it into
the other plate. Tighten the screw temporarily.
5. Remove the set screw attached to the auto switch. Figure 1. Switch insert angle
6. Attach the switch spacer to the auto switch. e
7. Insert the auto switch with a switch spacer from the back of the Switch spacer
switch holder and set it at the specified position. (Stainless steel)
(Insert the auto switch with an angle of approximately 10 to
d
15 . See figure 1.)
Switch holder y
8. To secure the auto switch, tighten the switch mounting screw u
with the specified torque (0.8 N·m to 1.0 N·m). (Resin) Auto switch
b
t
Auto switch mounting screw
Adjusting the Switch Position (Low carbon steel wire rod) Set screw (unused)
1. Unloosen the auto switch mounting screw 3 turns to adjust the
c q r
auto switch set position.
2. Tighten the screw as described above (8) after adjustment. Switch bracket e i
(Stainless steel)
Dismounting Auto Switch
1. Remove the auto switch mounting screw from the switch holder.
2. Move the auto switch back towards the position where it stops
at the lead wire side.
3. Hold up the lead wire side of the auto switch at the angle of w The parts indicated in are
around 45 . attached to BJ3-1.
4. Maintain the angle, and pull back the auto switch obliquely at
the same angle.
Face the rubber lining surface upward.
Note 1) Be careful not to pull or strain the lead wires.
Be careful not to apply excess tensile force (over 10 N) to the auto
switches. a 60° to 80°
Adjust the auto switch position after sufficiently loosening its screw. For Auto switch mounting band Reinforcing
the band mounting type BJ3-1, loosen the screw three rotations or more. For CDJ2: BJ2- plates
Note 2) Be sure to use the switch spacer and switch bracket for the band
mounting type. For CDM2: BM2- BM2, BMA2
Use together with the conventional auto switch mounting bands (brack- For CDG1: BMA2-
ets) BJ2-, BM2- or BMA2-.
Confirm that a switch spacer is mounted to the end of the auto switch BJ2-, BM2- and BMA2- are a set of a and b shown
before fastening the auto switch. If the switch bracket is not mounted,
the auto switch may move after installation. above. BJ3-1 is a set of c, d and e shown above.

Auto Switch Mounting Bracket Part No. (Including bands and screws, two kinds of auto switch mounting brackets are used as a set.)
Applicable bore size (mm)
Cylinder series
6 10 16 20 25 32 40 50 63
BJ2-006
CDJ2 BJ3-1 BJ2-010 — — — — — —
BJ3-1 BJ2-016
CDVJ3/5, CDJ2X — BJ3-1 — — — — — —
CDBJ2, CDLJ2 — — — — — — — —
CDM2, CDBM2 BM2-020 BM2-025 BM2-032 BM2-040
CDM2X, CDM2Y — — —
BJ3-1 BJ3-1 BJ3-1 BJ3-1
— —
CDLM2, CDVM3/5
CDG1, CDBG1 BMA2-063
CDG1Y, MGG — — — BMA2-050 BJ3-1
RHC BMA2-020 BMA2-025 BMA2-032 BJ3-1
MGC — — — BJ3-1 BJ3-1 BJ3-1 —
BMA2-040 —
CDLG1, CDNG — — — —
BJ3-1
MLGC, REC — — — — —
CKG1 — — — — — —
BMA2-032 BMA2-063
CLK2GA — — — — —
BJ3-1 BJ3-1
BMA2-050
CLK2GB — — — — — — — BJ3-1
BMA2-040
RSDG — — — — — —
BJ3-1 —

1356
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1357

How to Mount and Move the Auto Switch

Caution How to Mount and Move the Auto Switch


1. Tighten the screw under the specified torque when mounting auto switch.
2. Set the auto switch mounting band perpendicularly to cylinder tube.

Auto switch

Auto switch mounting screw


M4 x 0.7 x 22 l
Mounting correctly Mounting incorrectly

Auto switch mounting band


(With bracket)

<Applicable auto switch> 1. Put a mounting band on the cylinder tube and set it at the auto switch
Solid state ······ D-G59, D-G5P, D-K59, D-G5BAL, mounting position.
2. Put the mounting section of the auto switch between the band mounting
D-G59W, D-G5PW, D-K59W, holes, then adjust the position of mounting holes of switch to those of
D-G59F, D-G5NTL, D-G5NBL mounting band.
3. Lightly thread the auto switch mounting screw through the mounting hole into
Reed ··············· D-B53, D-B54, D-B64, D-B59W the thread part of band fitting.
4. After reconfirming the detection position, tighten the mounting screw to
secure the auto switch while properly contacting the auto switch bottom part
and the cylinder tube.
(The tightening torque of M4 screw should be about 1 to 1.2 N·m.)
5. Modification of the detection position should be made in the condition of 3.

Auto Switch Mounting Bracket Part No. (Including band and screw)
Applicable bore size (mm)
Cylinder series
20 25 32 40 50 63 80 100
CDM2, CDBM2
CDM2X, CDM2Y BA2-020 BA2-025 BA2-032 BA2-040 — — — —
CDLM2, CDVM3/5
CDA2, CDBA2 — — — BH2-040 BA5-050 BAF-06 BAF-08 BAF-10
CDA2Q, CDA2H, CDA2Y
CDLA, CDL1, CDNA, CE2 — — —
CDV3, CDVS1 BA-06 BA-08 BA-10
BA-05
CDG1, CDBG1, CDG1Y
MGG, RHC
MGC BA-01 BA-02 BA-32 BA-04 — — —
CDLG1, CDNG — — — —
MLGC, REC — — — —
CKG1 — — — — —
CLK2GA — — BA-32 BA-05 BA-06 — —
CLK2GB — — — — — —
CDG5S NBA-088S NBA-106S BGS1-032S BAF-04S BAF-05S BAF-06S BAF-08S BAF-10S
[Mounting screws set made of stainless steel]
The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment. (Please order the auto switch
mounting band separately, since it is not included.)
BBA3: For D-B5/B6/G5/K5
“D-G5BAL” auto switch is set on the cylinder with the stainless steel screws above when shipped.
When an auto switch is shipped independently, “BBA3” screws are attached.

Stainless Steel Mounting Screw Set


Description
Part no. Applicable auto switch mounting bracket part no. Applicable auto switch
Part Size Qty.
BA-01, BA-02, BA-32, BA-04
BA-05, BA-06, BA-08, BA-10
BA2-020, BA2-025, BA2-032, BA2-040
D-B5, B6
BBA3 Auto switch mounting screw M4 x 0.7 x 22L 1 BA5-050, BHN2-025, BSG1-032
D-G5, K5
BH2-040, BH2-050, BH2-080, BH2-100
BAF-32, BAF-04, BAF-05 D-
BAF-06, BAF-08, BAF-10

1357
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1358

How to Mount and Move the Auto Switch

Mounting Bracket Band Mounting Style


<Applicable auto switch>
Solid state ······ D-H7A1, D-H7A2, D-H7B,
Caution
D-H7BAL, D-H7C, D-H7NF, 1. Tighten the screw under the specified torque when mounting auto switch.
D-H7NW, D-H7PW, D-H7BW 2. Set the auto switch mounting band perpendicularly to cylinder tube.
Reed ··············· D-C73, D-C76, D-C80, D-C73C,
D-C80C

How to Mount and Move the Auto Switch Mounting correctly Mounting incorrectly

1. For Series CDJ2: Put a mounting bracket on the cylinder tube.


Auto switch
For Series CDM2: Put a mounting band on the cylinder tube and set it at the
Auto switch auto switch mounting position.
mounting screw 2. Put the mounting section of the auto switch between the band mounting
M3 x 0.5 x 14 l
holes, then adjust the position of mounting holes of switch to those of
Auto switch
mounting band.
Auto switch Auto switch mounting 3. Lightly thread the auto switch mounting screw through the mounting hole into
mounting bracket screw
M3 x 0.5 x 14 l the thread part of band fitting.
4. After setting the whole body to the detecting position by sliding, tighten the
mounting screw to secure the auto switch while properly contacting the auto
switch bottom part and the cylinder tube. (Tightening torque of M3 screw
Auto switch mounting band
(With bracket) should be 0.8 to 1 N·m.)
5. Modification of the detection position should be made in the condition of 3.
6. After auto switch is mounted and fixed, attach a protective tube on the tip of
an auto switch mounting screw.

Auto Switch Mounting Bracket Part No. (Including band and screw)
Applicable bore size (mm)
Cylinder series
6 10 16 20 25 32 40 50 63
CDJ2 BJ2-006 — — — — — —
BJ2-010
CDVJ3/5, CDJ2X — BJ2-016 — — — — — —
CDBJ2, CDLJ2 — — — — — — — —
CDM2, CDBM2
CDM2X, CDM2Y — — — BM2-020 BM2-025 BM2-032 BM2-040 — —
CDLM2, CDVM3/5
CDG1, CDBG1 — — — BMA2-063
CDG1Y, MGG, RHC BMA2-050
MGC — — — BMA2-020 BMA2-025 BMA2-032 —
CDLG1, CDNG — — — BMA2-040 — —
MLGC, REC — — — — —
CKG1 — — — — — —
CLK2GA — — — — — BMA2-032 BMA2-063
BMA2-050
CLK2GB — — — — — — —
RSDG — — — — — — BMA2-040 —
CDJ5S — BJ2-010S BJ2-016S — — — — — —
[Mounting screws set made of stainless steel]
The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment. (Please order the auto switch
mounting band separately, since it is not included.)
BBA4: For D-C7/C8/H7
“D-H7BAL” switch is set on the cylinder with the stainless steel screws above when shipped.
When only an auto switch is shipped independently, “BBA4” screws are attached.

Stainless Steel Mounting Screw Set


Description
Part no. Applicable auto switch mounting bracket part no. Applicable auto switch
Part Size Qty.
BJ2-006, BJ2-010, BJ2-016
BM2-020, BM2-025, BM2-032, BM2-040 D-C7, C8
BBA4 Auto switch mounting screw M3 x 0.5 x 14L 1 BMA2-020, BMA2-025, BMA2-032 D-H7
BMA2-040, BMA2-050, BMA2-063
BHN3-025, BHN3-032, BHN3-040

1358
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1359

How to Mount and Move the Auto Switch

Caution <Applicable auto switch>


Solid state ······ D-G39A, D-K39A
1. Tighten the screw under the specified torque when mounting auto switch. Reed ··············· D-A33A, D-A34A, D-A44A
2. Set the auto switch mounting band perpendicularly to cylinder tube.

How to Mount and Move the Auto Switch

Mounting correctly Mounting incorrectly

<Applicable auto switch> Auto switch


mounting screw
Solid state ······ D-G39, D-K39 M5 x 0.8 x 8 l
Reed ··············· D-A33, D-A34, D-A44
How to Mount and Move the Auto Switch
D-A3, D-G3/K3 type Auto switch
Auto switch
1. Loosen the auto
switch mounting Auto switch mounting screw
screws at both M5 x 0.8 x 8 l
sides t o pull
Auto switch mounting screw down the hook.
M5 x 0.8 x 16 l 2. P u t a n a u t o
switch mounting
band on the cy-
linder tube and Auto switch mounting band
set it at the auto (With bracket)
switch mounting
Fook
position, and
Auto switch mounting band then hook the
band.
3. Screw lightly the 1. Tighten completely the auto switch mounting screw on the auto
auto switch switch body side.
D-A44 mounting screw. 2. Put a mounting band on the cylinder tube and set it at the auto
Auto switch 4. Set the whole switch mounting position. Put the mounting section of auto switch
body to the de- between the interval of mounting band, then adjust the position of
tecting position mounting holes of switch to those of mounting band.
by sliding, 3. Lightly thread the auto switch mounting screw through the mounting
tighten the hole into the thread part of band fitting.
mounting screw 4. After reconfirming the detecting position, tighten the mounting screw
Auto switch mounting screw
to secure the to secure the auto switch. (The tightening torque of M5 screw
M5 x 0.8 x 16 l
auto switch. should be about 2 to 3 N·m.)
(The tightening 5. Modification of the detecting position should be made in the
torque should condition of 3.
be about 2 to 3 Auto Switch Mounting Bracket Part No. (Including band and screw)
N·m.) Applicable bore size (mm)
Fook 5. Modification of Cylinder series
the detecting 20 25 32 40
Auto switch mounting band
position should CDM2, CDBM2
be made in the CDLM2, CDM2X BM3-020 BM3-025 BM3-032 BM3-040
condition of 3. CDM2Y

Auto Switch Mounting Bracket Part No. (Band)


Applicable bore size (mm)
Cylinder series
20 25 32 40 50 63 80 100 125 140 160 180 200
MDB — — BMB2 BMB2 BMB1 BS1-125 — — — —
-032 -040 -050 BMB1 BMB1 BMB1
MDBB, MDNB — — — — — — —
-063 -080 -100
CDA2, CDBA2 — — — BDS-04M BDS-05M — — — — —
CDA2Q, CDA2H
CDA2Y, CDLA — — — — — — — —
CDNA, CE2 BD1 BD1 BD1 BD1 BD1
CDV3, CDVS1 -04M -05M -06M -08M -10M
CDL1 — — — — — D-
CDS2 — — — — — — — — BS1 BS1 BS1 — —
CDS1, CDLS — — — — — — — — -125 -140 -160 BS1-180 BS1-200
CDNS — — — — — — — — — —
RHC BD1-01M BD1-02M BD1-02 BD1-08M BD1-10M — — — — —
BD1
CKG1 — — — -04M BD1 BD1 — — — — — — —
CLK2GA — — — -05M -06M — — — — — — —
CLK2GB — — — — — — — — — — —

1359
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 1

How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch> CDQP2B12 to 25
Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V), a
D-M9NW(V), D-M9PW(V), D-M9BW(V), Auto switch Set screw
Auto switch
mounting screw (Unused)
D-M9NA(V), D-M9PA(V), D-M9BA(V) M3 x 0.5 x 8 l r
Reed ··············· D-A90(V), A93(V), A96(V) (For BQ-1)
u
t
How to Mount and Move the Auto Switch c
e
CDQP2B12 to 25 Auto switch mounting bracket y d
1. Insert the square nut for BQ-1 in the switch mounting rail and set it Auto switch mounting
screw
at the approximate auto switch mounting position. b M2.5 x 0.45 x 6 l
2. Fit the convex part of the auto switch mounting bracket arm over Square nut
the concave part of the rail, and slide the arm to the nut position. (For BQ-1) w
3. Push the auto switch mounting screw (M3 for BQ-1) lightly into the
square nut through the hole of the auto switch mounting arm.
4. Remove the set screw (M2.5) attached to the auto switch. Cylinder
5. Insert the auto switch in the auto switch attachment part of the auto q
switch mounting bracket.
6. Secure the auto switch mounting screw (M2.5). (Tightening torque BQ-1 and BMU1-025 are a set of a and b shown above.
of M2.5 screw: 0.1 to 0.2 N·m) BQ2-012 is a set of c and d shown above.
7. Secure the auto switch mounting screw (3) after confirming the
detecting position. (Tightening torque of M3 screw: 0.5 to 0.7 N·m)
8. Modify the detecting position while the auto switch is secured at
the position of (3) in the figure. CDQP2B32 to 100
a
CDQP2B32 to 100
Auto switch t Auto switch
1. Insert the square nut for BQ-2 in the switch mounting rail and set it Set screw
mounting screw (Unused)
at the approximate auto switch mounting position. M3 x 0.5 x 10 l
2. Fit the protruding part of the switch mounting spacer over the (For BQ-2)
concave part of the rail, and slide the spacer to the nut position. i y
d r
3. Fit the convex part of the auto switch mounting bracket arm over
Auto switch mounting bracket u
the concave part of the switch spacer. e
4. Turn the auto switch mounting screw (M3 for BQ-2) lightly into the c Auto switch mounting
square nut through the mounting holes of the auto switch mounting Switch spacer e screw
arm and switch spacer. (For BQ-2) M2.5 x 0.45 x 6 l
5. Remove the set screw (M2.5) attached to the auto switch. b
6. Insert the auto switch in the auto switch attachment part of the auto Square nut w
switch mounting bracket. (For BQ-2)
7. Secure the auto switch mounting screw (M2.5). (Tightening torque Cylinder
of M2.5 screw: 0.1 to 0.2 N·m)
8. Secure the auto switch mounting screw (4) after confirming the q
detecting position. (Tightening torque of M3 screw: 0.5 to 0.7 N·m)
9. Modify the detecting position while the auto switch is secured at BQ-2 is a set of a, b and c shown above.
the position of (4) in the figure. BQ2-012 is a set of d and e shown above.

Auto Switch Mounting Bracket Part No. (Nut, screws, (spacer) and auto switch mounting bracket; two kinds of auto switch mounting brackets are used as a set.)
Applicable bore size (mm)
Cylinder series
12 16 20 25 32 40 50 63 80 100
BQ-1 BQ-1 BQ-1 BQ-1
CDQP2B BQ2-012 BQ2-012 BQ2-012 BQ2-012
BQ-2 BQ-2
CDQ2X, CDQ2Y BQ-2 BQ2-012 BQ2-012
CDLQ, CDQM — — — — BQ2-012
RDQ BQ-2
RDLQ, RZQ — — — — BQ-2 BQ-2 BQ2-012 — —
BQ2-012 BQ2-012 —
RSDQ — — BQ-1 — —
MK, MK2 — — BQ-1 BQ2-012 — —
BQ2-012 BQ-2
BQ-1 BQ2-012
CE1 BQ2-012 — — — —

CXT — — — — — — — —
BQ-2
CKQ, CLKQ — — — — —
BQ2-012
— — —
BMU1-025
MDU — — — BMU1-025 BMU1-025 BMU1-025 BMU1-025 BQ2-012 — —
BQ2-012 BQ2-012 BQ2-012 BQ2-012
MDLU — — — — — —
Note 1) Color or gloss differences in the metal surfaces have no effect on metal performance.
The special properties of the chromate (trivalent) applied to the main body of the auto switch mounting bracket for BQ2-012 result in differences in coloration
depending on the production lot, but these have no adverse impact on corrosion resistance.
Note 2) When installing D-M9A(V)L with BQ2-012 shown above, use BQ2-012S with stainless steel auto switch mounting screws (M2.5 x 0.45 x 6 l).
1360
How to Mount and Move the Auto Switch

<Applicable auto switch> How to Mount and Move the Auto Switch
Solid state ······ D-F79, D-F7P, D-J79,
D-F7NV, D-F7PV, Auto switch mounting screw Auto switch mounting screw
D-F7BV, D-J79C, (M3 x 0.5 x 8 l) (M3 x 0.5 x 8 l)
D-F79W, D-F7PW,
D-J79W, D-F7NWV,
D-F7BWV, D-F79F, Auto switch
D-F7BAL, D-F7BAVL,
D-F7NTL Auto switch mounting nut
Auto switch mounting nut
Reed ··············· D-A72, D-A73, D-A80, (M3)
(Square nut)
D-A72H, D-A73H,
D-A76H, D-A80H,
Auto switch mounting rail
D-A73C, D-A80C, D-A79W
1. Slide the auto switch mounting nut inserted into the
mounting rail and set it at the auto switch mounting
position. Auto switch mounting screw
2. Fit the convex part of auto switch mounting arm into (M3 x 0.5 x 6 l) Auto switch mounting screw
the concave part of auto switch mounting rail. Then (M3 x 0.5 x 10 l)
slide the switch over the nut. Auto switch
(Series CDQ2: Fit the convex part of auto switch mounting nut
mounting arm through the auto switch spacer into the Auto switch spacer
concave part of auto switch mounting rail.)
3. Push the auto switch mounting screw lightly into the
mounting nut through the hole of auto switch mounting
arm.
Auto switch
4. After reconfirming the detecting position, tighten the mounting nut
mounting screw to secure the auto switch. (Tightening
torque of M3 screw should be 0.5 to 0.7 N·m.)
5. Modification of the detecting position should be made
in the condition of 3.

Auto Switch Mounting Bracket Part No. (Including nut, screw, (spacer))
Applicable bore size (mm)
Cylinder series
12 16 20 25 32 40 50 63 80 100 125 140 160
CDQ2 (Except Z), CDQP2B BQ-1 BQ-1 BQ-1 BQ-1 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 BQ-2 — — —
CDQ2 (Large bore size: Except Z) — — — — — — — — — — BQ-2 BQ-2 BQ-2
CDQ2X, CDQ2Y
CDLQ, CDQM — — — — BQ-2 BQ-2 — — —
RDQ BQ-2
RDLQ, RZQ — — — — BQ-2 — — — — —
RSDQ — — BQ-2 BQ-2 — — — — — —
BQ-1
MK (Except Z), MK2 — — BQ-1 — — — — —
BQ-2
CE1 BQ-1 — — — — — — —
CXT — — — — — — — — — — —
MDU (Except Z) — — —
BMU1-025 BMU1-025 BMU1-025 BMU1-025
BMU1-025 — — — — —
MDLU — — — — — — — — —
[Mounting screws set made of stainless steel]
The set of stainless steel mounting screws (with nuts) described below is available and can be used depending on the operating environment. (Please
order the auto switch spacer, since it is not included.)
BBA2: For D-A7/A8/F7/J7
“D-F7BAL” auto switch is set on the cylinder with the stainless steel screws above when shipped.
When only an auto switch is shipped independently, “BBA2” screws are attached.

Stainless Steel Mounting Screw Set


Description
Part no. Applicable auto switch mounting bracket part no. Applicable auto switch
Part Size Qty.
No.
M3 x 0.5 x 6L 1 BMU1-025
D-쏔
1 Auto switch mounting screw M3 x 0.5 x 8L 1 BQ-1
D-A7, A8
BBA2 M3 x 0.5 x 10L 1 BQ-2
D-F7, J7
2 Auto switch mounting nut (Square nut) M3 x 0.5 1 BQ-1
3 Auto switch mounting nut (Convex shape) M3 x 0.5 1 BQ-2
Note 1) A spacer for BQ-2 (black resin) is not included.
Note 2) When using D-A9쏔(V)/M9쏔(V)/M9쏔W(V)/M9쏔A(V)L auto switches with BQ2-012, use stainless steel screws suitable for the auto switch mounting bracket
applicable for each cylinder series.
1361 B
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1362

How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch> <Applicable auto switch>
Solid state ······ D-P4DWL Solid state ······ D-P4DWL

How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
Auto switch mounting bracket fixing screw
Hexagon socket head cap bolt
Hexagon wrench key 2
M3 x 0.5 x 14 l
Hexagon socket head cap screw (M2.5 x 8 l)

Spring washer

Auto switch Magnetic field


mounting bracket resistant
auto switch

Auto switch
mounting nut

Hexagon wrench key 2.5


Auto switch mounting screw Auto switch
Round head Phillips screw Hexagon socket head cap screw (M3 x 16 l)
with spring washer
M3 x 0.5 x 16 l

1. Mount the auto switch mounting bracket onto the auto switch mounting 1. Insert the hexagon socket head cap screw (M2.5 x 0.45 x 8 l) down
nut by tightening bracket fixing screw lightly through the mounting hole on lightly to the M2.5 tapped portion of the lower part of auto switch
the top of bracket. mounting bracket's concave part. (2 locations) Use caution to avoid the
2. Insert the auto switch mounting bracket assembly (bracket + nut) into the tip of a screw from sticking out of the auto switch mounting bracket's
mounting groove and set it at the auto switch mounting position. bottom surface.
3. Push the auto switch mounting screw lightly into the auto switch through 2. Install a spring washer in the hexagon socket head cap bolt (M3 x 0.5 x
the auto switch mounting hole to secure. 16 l), then put it through the part of through-holes (2 locations) of an auto
4. After reconfirming the detecting position, tighten the mounting screw to switch.
secure the auto switch mounting bracket and the auto switch. (Tightening 3. As for auto switch mounting bracket, slightly thread the hexagon socket
torque should be 0.5 to 0.7 N·m.) head cap screw w into M3 tapped portion. (2 locations)
4. Fit the auto switch mounting bracket into the auto switch mounting groove
on the cylinder body, and then slide it to the detection position roughly.
5. After reconfirming the detecting position, tighten the mounting screw to
secure the auto switch.

Auto Switch Mounting Bracket Part No. Auto Switch Mounting Bracket Part No.
(Including bracket, screw) (Including bracket, screw)
Applicable bore size (mm) Applicable bore size (mm)
Cylinder series Cylinder series
40 50 63 80 100 32 40 50 63 80 100
CDQ2, CDBQ2 MGP, MLGP BMG1-040 BMG1-040 BMG1-040
CDQ2X, CDQ2Y BQP1-050 BQP1-050 BMG1-040 BMG1-040 BMG1-040
MGT — — —
CDLQ, CDQM BQP1-050 BQP1-050
MK, MK2 BQP1-050 — —
RZQ
CKQ, CLKQ — —



— Caution
Auto Switch Mounting Tool
• When tightening hexagon socket head cap screw of an auto switch, use a
hexagon wrench key 2 and 2.5, depending on the case.

Tightening Torque
• As a guide, set approximately 0.3 to 0.5 N·m for M2.5, 0.5 to 0.7 N·m for
M3 respectively.

1362
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 3

How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch>
Solid state ······ D-P3DW Hexagon socket
head cap screw
Direct Mounting to the Round Groove (M2.5 x 9 L)

Auto Switch
Mounting Hexagon socket
Applicable cylinder/actuator head cap screw Protrusion
Bracket
(M2.5 x 6 L)
Part No.
CDQS ø25
Compact cylinder
CDQ2 ø32 to ø100 BQ3-032S Note)
Compact cylinder with lock CDLQ ø25 to ø100 BQ3-032S
Pin clamp cylinder CKQG ø50 Auto switch
mounting bracket
Pin clamp cylinder with lock CLKQG ø50
Note) When the auto switch is mounted onto the CDBQ2 end lock type,
Note) When the auto switch
please contact SMC. mounting bracket is
How to Mount and Move the Auto Switch ordered by its part
number, it includes the
1. Insert the protrusion on the bottom of the auto switch into the mat- bracket and screws in the
ing part of the auto switch mounting bracket and fix the auto switch dashed line.
and the auto switch mounting bracket temporarily by tightening the
hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
2. Insert the temporarily tightened mounting bracket into the mat- Caution for the Cylinder/Actuator Mounting
ing groove of the cylinder/actuator, and slide the auto switch ∗ When mounting the D-P3DW onto a cylinder/actuator with ø32
onto the cylinder/actuator through the groove. to ø50, to avoid mutual interference, use a fitting with width
3. Check the detecting position of the auto switch and fix the auto across flats 12 mm or less for ø32 and ø40, and use a fitting
switch firmly with the hexagon socket head cap screw (M2.5 x with width across flats 14 mm or less for ø50. Also, if the corner
6 L, M2.5 x 9 L).∗ of the fitting interferes with the housing of the auto switch,
4. If the detecting position is changed, go back to step 2. adjust the tightening of the fitting to eliminate the interference.
In the case of interference with an elbow type fitting, direct the
∗ The hexagon socket head cap screw (M2.5 x 6 L) is used to fix the
port of the fitting away from the auto switch. Such interference
mounting bracket and cylinder/actuator.
This enables the replacement of the auto switch without adjusting the
must be avoided especially when a speed controller and speed
auto switch position. exhaust controller with a fitting are selected.
Note 1) Ensure that the auto switch is covered with the mating groove to ∗ In the CDQSø25 and CDLQø25, the auto switch will interfere
protect the auto switch. with the fitting if mounted onto the face with the port, so it
Note 2) The torque for tightening the hexagon socket head cap screw needs to be mounted on a different face.
(M2.5 x 6 L, M2.5 x 9 L) is 0.2 to 0.3 N·m.
Note 3) Tighten the hexagon socket head cap screws evenly.

1362-1
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 4

How to Mount and Move the Auto Switch

<Applicable auto switch>


Solid state ······ D-P3DW

Direct Mounting to the Square Groove


Auto Switch
Mounting
Applicable cylinder/actuator
Bracket
Part No.
MGP ø25 to ø100
Compact guide cylinder
MGPS ø50, ø80 BMG5-025S
Compact guide cylinder with lock MLGP ø25 to ø100
Note) For the MGP end lock type, as the auto switch cannot be mounted
onto the lock mechanism face, mount it to the groove on the bottom
of the lock mechanism face.

How to Mount and Move the Auto Switch


1. Insert the protrusion on the bottom of the auto switch into the mat-
ing part of the auto switch mounting bracket and fix the auto switch
and the auto switch mounting bracket temporarily by tightening the
hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
2. Insert the temporarily tightened mounting bracket into the mat-
ing groove of the cylinder/actuator, and slide the auto switch
onto the cyinder/actuator through the groove.
3. Check the detecting position of the auto switch and fix the auto
switch firmly with the hexagon socket head cap screw (M2.5 x
6 L, M2.5 x 9 L).∗
4. If the detecting position is changed, go back to step 2.
∗ The hexagon socket head cap screw (M2.5 x 6 L) is used to fix the
mounting bracket and cylinder/actuator.
This enables the replacement of the auto switch without adjusting the
auto switch position.
Note 1) Ensure that the auto switch is covered with the mating groove to
protect the auto switch.
Note 2) The torque for tightening the hexagon socket head cap screw
(M2.5 x 6 L, M2.5 x 9 L) is 0.2 to 0.3 N·m.
Note 3) Tighten the hexagon socket head cap screws evenly.

Hexagon socket
head cap screw
(M2.5 x 9 L)

Hexagon socket
head cap screw
Protrusion
(M2.5 x 6 L)

BMG5-025S Note)

Auto switch
mounting bracket

D-
Note) When the auto switch
mounting bracket is
ordered by its part
number, it includes the
bracket and screws in the
dashed line.

1362-2
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 5

How to Mount and Move the Auto Switch

Mounting Bracket Rail Mounting Style


<Applicable auto switch> <Applicable auto switch>
Solid state ······ D-P4DWL Solid state ······ D-P4DWL

How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
Auto switch mounting bracket fixing screw
Hexagon socket head cap bolt
Hexagon wrench key 2
M3 x 0.5 x 14 l
Hexagon socket head cap screw (M2.5 x 8 l)

Spring washer

Auto switch Magnetic field


mounting bracket resistant
auto switch

Auto switch
mounting nut

Hexagon wrench key 2.5


Auto switch
Auto switch mounting screw Hexagon socket head cap screw (M3 x 16 l)
Round head Phillips screw
with spring washer
M3 x 0.5 x 16 l

1. Mount the auto switch mounting bracket onto the auto switch 1. Insert the hexagon socket head cap screw (M2.5 x 0.45 x 8 l)
mounting nut by tightening bracket fixing screw lightly through down lightly to the M2.5 tapped portion of the lower part of
the mounting hole on the top of bracket. auto switch mounting bracket’s concave part. (2 locations) Use
2. Insert the auto switch mounting bracket assembly (bracket + caution to avoid the tip of a screw from sticking out of the auto
nut) into the mounting groove and set it at the auto switch switch mounting bracket’s bottom surface.
mounting position. 2. Install a spring washer in the hexagon socket head cap bolt
3. Push the auto switch mounting screw lightly into the auto (M3 x 0.5 x 16 l), then put it through the part of through-holes
switch through the auto switch mounting hole to secure. (2 locations) of an auto switch.
4. After reconfirming the detecting position, tighten the mounting 3. As for auto switch mounting bracket, slightly thread the hexa-
screw to secure the auto switch mounting bracket and the gon socket head cap screw w into M3 tapped portion. (2 loca-
auto switch. (Tightening torque should be 0.5 to 0.7 N·m.) tions)
4. Fit the auto switch mounting bracket into the auto switch
Auto Switch Mounting Bracket Part No. mounting groove on the cylinder body, and then slide it to the
detection position roughly.
(Including bracket, screw) 5. After reconfirming the detecting position, tighten the mounting
Applicable bore size (mm) screw to secure the auto switch.
Cylinder series
40 50 63 80 100
CDBQ2
CDQ2X, CDQ2Y BQP1-050 BQP1-050 Auto Switch Mounting Bracket Part No.
CDLQ, CDQM BQP1-050 BQP1-050 (Including bracket, screw)
MK, MK2 BQP1-050 — — Cylinder Applicable bore size (mm)
RZQ — — series 32 40 50 63 80 100
CKQ, CLKQ — — — — MGP, MLGP BMG1-040 BMG1-040 BMG1-040
BMG1-040 BMG1-040 BMG1-040
Note) Please consult SMC for mounting on the CDQ2 series. MGT — — —

Caution
Auto Switch Mounting Tool
• When tightening hexagon socket head cap screw of an auto switch, use a
hexagon wrench key 2 and 2.5, depending on the case.

Tightening Torque
• As a guide, set approximately 0.3 to 0.5 N·m for M2.5, 0.5 to 0.7 N·m for
M3 respectively.

1362-3
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1363

How to Mount and Move the Auto Switch

<Applicable auto switch>


Solid state ······ D-P4DWL

How to Mount and Move the Auto Switch


Hexagon socket head cap screw
With spring washer, M3 x 0.5 x 5 l Auto switch mounting bracket
Auto switch
Flat washer
ø8 x ø3.3 x t0.8 Round head Phillips screw
With spring washer,
M3 x 0.5 x 14 l

Auto switch mounting nut

1. From the cutoff part of the rail on the cylinder body, insert the auto switch
mounting nuts (2 pcs.) into the rail groove.
2. Slide the auto switch mounting nuts (2 pcs.) and set into the auto switch
mounting position roughly. (25 mm or more should be left for the distance
between 2 nuts.)
3. Insert the convex portion of the auto switch mounting bracket into the
concave portion of a rail groove. Through-hole for the auto switch
mounting bracket should be placed on the auto switch mounting nut.
4. Put a flat washer (ø8 x ø3.3) through a hexagon socket head screw (with
spring washer, M3 x 0.5 x 5 l) and passing through the hole of an auto
switch mounting bracket, then turning it lightly down to a mounting nut of
auto switch. (2 locations)
5. Put a round head Phillips screw (with spring washer, M3 x 0.5 x 14 l)
through the auto switch's through-hole (2 locations), and then push it
down into the M3 tapped part on the auto switch mounting bracket while
turning it lightly.
6. After reconfirming the detecting position, tighten the auto switch mounting
screw to secure the auto switch mounting bracket and the auto switch.
(Tightening torque of M3 screw should be 0.5 to 0.7 N·m.)

Auto Switch Mounting Bracket Part No.


(Including bracket, screw)
Applicable bore size (mm)
Cylinder series
40 50 63
MDU BMU2-040
BMU2-040 BMU2-040
MDLU —

D-

1363
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1364

How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> Set screw
Watchmaker’s
(precision)
Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V), M2.5 x 0.45 x 4 l screwdriver
D-M9NW(V), D-M9PW(V), D-M9BW(V),
D-M9NA(V), D-M9PA(V), D-M9BA(V) Hexagon socket
r
head set screw
Reed ··············· D-A90(V), A93(V), A96(V) M4

How to Mount and Move the Auto Switch


1. Fix it to the detecting position with a set screw by installing an auto Put the auto switch
e on the surface of the
switch mounting bracket in cylinder tie-rod and letting the bottom sur-
face of an auto switch mounting bracket contact the cylinder tube firmly. cylinder tube.
w
2. Fix it to the detecting position with a set screw (M4).
(Use a hexagon wrench.) Auto switch
3. Fit an auto switch into the auto switch mounting groove to set it roughly
to the mounting position for an auto switch. Auto switch
4. After confirming the detecting position, tighten up the mounting screw mounting
(M2.5) attached to an auto switch, and secure the auto switch. q bracket
5. When changing the detecting position, carry out in the state of 3.
Note 1) To protect auto switches, ensure that main body of an auto switch should be
embedded into auto switch mounting groove with a depth of 15 mm or more.
Note 2) Set the tightening torque of a hexagon socket head set screw (M4) to be 1 to
Tie-rod
1.2 N · m.
Note 3) When tightening an auto switch mounting screw (M2.5), use a watchmaker’s
screwdriver with a grip diameter of 5 to 6 mm.
Also, set the tightening torque to be 0.05 to 0.15 N · m. As a guide, turn 90°
Cylinder tube
from the position where it comes to feel tight.

Auto Switch Mounting Bracket Part No. (Including Bracket, Set Screw)
Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100 125 140 160 180 200
MDB BMB5 BMB5 BA7 BA7 BA7 BA7 BA7-080 — — — —
MDBB, MDNB -032 -032 -040 -040 -063 -063 — — — — —
CDA2, CDBA2
CDA2Q
CDA2H — BA7 BA7 BA7 BA7 BA7 — — — — —
CDA2Y, CDLA -040 -040 -063 -080 -080
CDNA, CE2
CDL1 — — —
CDS1, CDLS — — — — — — BS5 BS5 BS5 BS5-180 BS5-200
CDS2 — — — — — — -125 -125 -160 — —
CDNS — — — — — — — —

Note 1) When using type D-M9A(V)L, please order stainless steel screw set BBA1 separately (page 1365) , and use the stainless steel set screws, after selecting
set screws of the appropriate length for the cylinder series—as shown in the table above.
Note 2) Color or gloss differences in the metal surfaces have no effect on metal performance.
The special properties of the chromate (trivalent) applied to the main body of the auto switch mounting bracket for BA7-, BMB5- and BS5- result in differ-
ences in coloration depending on the production lot, but these have no adverse impact on corrosion resistance.

1364
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1365

How to Mount and Move the Auto Switch

<Applicable auto switch> How to Mount and Move the Auto Switch
Solid state ······ D-F59, D-F5P,
D-J59, D-J51, D-F5BAL, Auto switch mounting screw (M4)
D-F59W, D-F5PW, D-J59W,
D-F59F, D-F5NTL
Reed ··············· D-A53, D-A54, D-A56, D-A64,
D-A67, D-A59W
Auto switch
1. Fix the auto switch on the auto switch mounting bracket with the Auto switch mounting bracket
auto switch mounting screw (M4) and install the set screw. Set screw (M4)
2. Fit the auto switch mounting bracket into the cylinder tie-rod and
then fix the auto switch at the detecting position with the hexagonal
wrench. (Be sure to put the auto switch on the surface of cylinder Tie-rod
tube.)
3. When changing the detecting position, loosen the set screw to move
the auto switch and then re-fix the auto switch on the cylinder tube.
(Tightening torque of M4 screw should be 1 to 1.2 N·m.)

Auto Switch Mounting Bracket Part No. (Including bracket, screw, set screw)
Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100 125 140 160 180 200
MDB BT-08 — — — —
BT-03 BT-03 BT-05 BT-05 BT-06 BT-06
MDBB, MDNB — — — — —
CDA2, CDBA2
CDA2Q
CDA2H — — — — — —
CDA2Y, CDLA BT-04 BT-04 BT-06 BT-08 BT-08
CDNA, CE2
CDV3, CDVS1
CDL1 — — —
CDS1, CDLS — — — — — — BT-18A BT-20
BT-12 BT-12 BT-16
CDS2 — — — — — — — —
CDNS — — — — — — — —
[Mounting screws set made of stainless steel]
The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
(Please order the auto switch mounting band separately, since it is not included.)
BBA1: For D-A5/A6/F5/J5
“D-F5BAL” auto switch is set on the cylinder with the stainless steel screws above when shipped.
When an auto switch is shipped independently, “BBA1” screws are attached.

Stainless Steel Mounting Screw Set


Description
Part no. Applicable auto switch mounting bracket part no. Applicable auto switch
No. Part Size Qty.
1 Auto switch mounting screw M4 x 0.7 x 8L 1 BT-
D-A5, A6
BT-03, BT-04, BT-05 D-F5, J5
BT-06, BT-08, BT-12
2 Set screw M4 x 0.7 x 6L 2 BA4-040, BA4-063, BA4-080 D-Z7, Z8
BMB4-032, BMB4-050 D-Y5, Y6, Y7
BMB5-032 D-A9
BBA1 BA7-040, BA7-063, BA7-080 D-M9
D-A5, A6
BT-16, BT-18A, BT-20
D-F5, J5 D-
3 Set screw M4 x 0.7 x 8L 3 BS4-125, BS4-160 D-Z7, Z8
BS4-180, BS4-200 D-Y5, Y6, Y7
BS5-125, BS5-160 D-A9
BS5-180, BS5-200 D-M9
Note 1) A spacer for BQ-2 (black resin) is not included.
Note 2) When using D-A9(V)/M9(V)/M9W(V)/M9A(V)L auto switches with BQ2-012, use stainless steel screws suitable for the auto switch mounting bracket
applicable for each cylinder series.

1365
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1366

How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Style


<Applicable auto switch> How to Mount and Move the Auto Switch
Solid state ······ D-G39C, D-K39C Auto switch mounting screw
Reed ··············· D-A33C, D-A34C, D-A44C (With hexagon socket head)
M5 x 0.8
1. Fix the auto switch mounting bracket (A) on the auto switch with the
set screw.
Auto switch
2. Fit the concave part of auto switch mounting bracket into tie-rod and
Bracket set screw
set the auto switch at the mounting position. (With hexagon socket head)
3. Insert the auto switch mounting bracket (B) from the underneath and M5 x 0.8 x 12 l
put lightly in the tie-rod with the mounting screw. Auto switch mounting bracket (A)
4. Set the whole body to the detecting position by sliding, tighten the
mounting screw to secure the auto switch. (Tightening torque of M5
screw should be 2 to 3 N·m.)
5. Modification of the detecting position should be made in the
condition of 3.

Auto switch mounting bracket (B)

Auto switch mounting screw


(With hexagon socket head)
M5 x 0.8

Auto switch

Bracket set screw


M5 x 0.8 x 12 l

Auto switch mounting bracket (A)

Auto switch mounting bracket (B)

Auto Switch Mounting Bracket Part No. (Including bracket, screw)


Applicable bore size (mm)
Cylinder series
40 50 63 80 100
CDA2, CDBA2
BA3-040 BA3-050 BA3-063 BA3-080 BA3-100
CDV3, CDVS1, CDL1, CE2, CNA

1366
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1367

How to Mount and Move the Auto Switch

<Applicable auto switch> <Applicable auto switch>


Solid state ······ D-Y59 AB , D-Y69 AB , D-Y7P(V), Solid state ······ D-P4DWL
D-Y7NW(V), D-Y7PW(V),
D-Y7BW(V), D-Y7BAL How to Mount and Move the Auto Switch
Reed ··············· D-Z73, D-Z76, D-Z80 MDB, MDBB, MDNB
Hexagon socket head cap screw
How to Mount and Move the Auto Switch M4 x 0.7 x 8 L
Auto switch mounting bracket
Watchmaker’s (precision) screwdriver

Hexagon socket head set screw (2)


Series MB, CA1: M4 x 0.7 x 6 L
Series CS1: M4 x 0.7 x 8 L

Auto switch Auto switch

Auto switch Tie-rod


mounting screw
Hexagon socket head cap screw
M3 x 0.5 x 14 L
Auto switch mounting bracket
CDA2, CDBA2, CDNA,
CDLA, CDL1 (ø40 to ø100)
Hexagon socket head set screw
M4 x 0.7 x 6 L
Auto switch mounting bracket

Note 1) When tightening an auto switch mounting screw, use a


watchmaker’s screwdriver with a grip diameter of 5 to 6 mm.
Also, set the tightening torque to be 0.05 to 0.1 N·m.
As a guide, turn 90° from the position where it comes to feel
tight. Set the tightening torque of a hexagon socket head set Auto switch
screw (M4 x 0.7) to be 1 to 1.2 N·m.
1. Fix it to the detecting position with a set screw by installing an auto Tie-rod
switch mounting bracket in cylinder tie-rod and letting the bottom surface Round head Phillips screw
of an auto switch mounting bracket contact the cylinder tube firmly.
With spring washer, M3 x 0.5 x 14 L
(Use hexagon wrench)
2. Fit an auto switch into the auto switch mounting groove to set it roughly 1. (For MDB)
to the auto switch mounting position for an auto switch. Slightly screw the hexagon socket head cap screw (M4 x 0.7 x 8 l) into
3. After confirming the detecting position, tighten up the mounting screw the M4 tapped portion of auto switch mounting bracket. (2 locations) Use
attached to an auto switch, and secure the switch. caution that the tip of the hexagon socket head cap screw should not
4. When changing the detecting position, carry out in the state of 2. stick out to the concave portion of auto switch mounting bracket.
(For CDA1)
∗ To protect auto switches, ensure that main body of an auto switch should Slightly screw the hexagon socket head cap screw (M4 x 0.7 x 6 l) into
be embedded into auto switch mounting groove with a depth of 15 mm or the M4 tapped portion of auto switch mounting bracket. (2 locations) Use
more. caution that the tip of the hexagon socket head set screw should not
stick out to the concave portion of auto switch mounting bracket.
2. (For MDB)
Auto Switch Mounting Bracket Part No. Put a hexagon socket head cap screw (M3 x 0.5 x 14 l) through the auto
switch's through-hole (2 locations), and then push it down into the M3
(Including Bracket, Set Screw) tapped part on the auto switch mounting bracket while turning it lightly.
Cylinder Applicable bore size (mm) (For CDA2)
series Put a hexagon socket head cap screw (with spring washer M3 x 0.5 x 14
32 40 50 63 80 100 125 140 160 180 200
l) through the auto switch's through-hole (2 locations), and then push it
MDB BMB4 BMB4 BMB4 BMB4 BA4 BA4 BA4-080 — — — — down into the M3 tapped part on the auto switch mounting bracket while
MDBB, MDNB -032 -032 -050 -050 -063 -063 — — — — — turning it lightly.
CDA2, CDBA2 3. Place the concave part of the auto switch mounting bracket into the
CDA2Q cylinder tie-rod, and slide the auto switch mounting bracket in order to
CDA2H — BA4 BA4 BA4 BA4 BA4 — — — — — set roughly to the detecting position.
CDA2Y, CDLA -040 -040 -063 -080 -080 4. After reconfirming the detecting position, tighten the M3 mounting screw
CDNA, CE2 to secure the auto switch by making the bottom face of auto switch
attached to the cylinder tube. (Tightening torque of M3 screw should be
CDL1 — — —
0.5 to 0.7 N·m.)
CDS1, CDLS — — — — — — BS4 BS4 BS4 BS4-180 BS4-200 5. Tighten up M4 screw of auto switch mounting bracket to secure the auto
CDS2 — — — — — — -125 -125 -160 — — switch mounting bracket. (Ensure that tightening torque of M4 screw
CDNS — — — — — — — — should be set 1.0 to 1.2 N·m.) D-
Note 2) When using type D-Y7BAL please order stainless steel screw set BBA1
Auto Switch Mounting Bracket Part No.
separately (page 1365), and use the stainless steel set screws, after se- (Including bracket, screw)
lecting set screws of the appropriate length for the cylinder series—as Cylinder Applicable bore size (mm)
shown in the table above. series 32 40 50 63 80 100
MDB, MDBB, MDNB BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080
CDA2, CDBA2 — BAP2-040 BAP2-040 BAP2-063 BAP2-080 BAP2-080
CDLA, CDL1, CDNA
1367
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 6

How to Mount and Move the Auto Switch

<Applicable auto switch>


Solid state ······ D-Y59 AB , D-Y69 AB , D-Y7P(V),
D-Y7NW(V), D-Y7PW(V),
D-Y7BW(V), D-Y7BAL
Reed ··············· D-Z73, D-Z76, D-Z80
How to Mount and Move the Auto Switch
Watchmaker’s (precision) screwdriver

Hexagon socket head set screw (2) 1. Fix it to the detecting position with a set screw by installing an auto switch
Series MB, CA2: M4 x 0.7 x 6L mounting bracket in cylinder tie-rod and letting the bottom surface of an
Series CS1, CS2: M4 x 0.7 x 8L auto switch mounting bracket contact the cylinder tube firmly.
(Use hexagon wrench)
2. Fit an auto switch into the auto switch mounting groove to set it roughly to
the auto switch mounting position for an auto switch.
Auto switch
3. After confirming the detecting position, tighten up the mounting screw
Auto switch attached to an auto switch, and secure the switch.
mounting screw 4. When changing the detecting position, carry out in the state of 2.

Auto switch ∗ To protect auto switches, ensure that main body of an auto switch should
mounting bracket be embedded into auto switch mounting groove with a depth of 15 mm or
more.

Note 1) When tightening an auto switch mounting screw, use a


watchmaker’s screwdriver with a grip diameter of 5 to 6 mm.
Also, set the tightening torque to be 0.05 to 0.1 N·m.
As a guide, turn 90° from the position where it comes to feel
tight. Set the tightening torque of a hexagon socket head set
screw (M4 x 0.7) to be 1 to 1.2 N·m.

Auto Switch Mounting Bracket Part No.


(Including Bracket, Set Screw)
Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100 125 140 160 180 200
MDB BA4-080 — — — —
BMB4-032 BMB4-032 BMB4-050 BMB4-050 BA4-063 BA4-063
MDBB, MDNB — — — — —
CDA2, CDBA2
CDA2Q
CDA2H — — — — — —
BA4-040 BA4-040 BA4-063 BA4-080 BA4-080
CDA2Y, CDLA
CDNA, CE2
CDL1 — — —
CDS1, CDLS — — — — — — BS4-180 BS4-200
BS4-125 BS4-125 BS4-160
CDS2 — — — — — — — —
CDNS — — — — — — — —
Note 2) When using type D-Y7BAL please order stainless steel screw set BBA1 separately (page 1365), and use the stainless steel set screws, after selecting set screws of the
appropriate length for the cylinder series—as shown in the table above.

D-

1367-1
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 7

How to Mount and Move the Auto Switch

Mounting Bracket Tie-rod Mounting Type


<Applicable auto switch> <Applicable auto switch>
Solid state ······ D-P3DW Solid state ······ D-P3DW
Applicable cylinder/actuator Applicable cylinder/actuator
Clamp cylinder CKG1 ø40 to ø63 MDB ø80 to ø125
Air cylinder
Clamp cylinder with lock CLK2G ø40 to ø63 CDA2 ø63 to ø100
MDB ø32 to ø63 MDNB ø80 to ø100
Air cylinder Air cylinder with lock
CDA2 ø40, ø50 CDNA ø63 to ø100
MDNB ø32 to ø63
Air cylinder with lock How to Mount and Move the Auto Switch
CDNA ø40, ø50
1. Install the auto switch mounting bracket 2 to the tie-rod, and fix it to the
How to Mount and Move the Auto Switch approximate mounting position with the cone points of hexagon socket
1. Insert the protrusion on the bottom of the auto switch into the mat- head cap screw (M4 x 8 L) while keeping firm contact between the bot-
ing part of the mounting bracket and fix the auto switch by tighten- tom of the auto switch mounting bracket 2 and the cylinder tube.
ing the hexagon socket head cap screw (M2.5 x 9 L). 2. Insert the protrusion on the bottom of the auto switch into the mating
2. Install the mounting bracket on which the auto switch is mounted to part of the auto switch mounting bracket 1 and fix the auto switch
the switch mounting rod, and move it to find the detecting position and the auto switch mounting bracket 1 temporarily by tightening the
while keeping firm contact between the bottom of the auto switch hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.
mounting bracket and the cylinder tube. 3. Insert the temporarily tightened mounting bracket 1 to the mating
3. After checking the detecting position, fix the auto switch mounting groove of the mounting bracket 2, and fix the auto switch by tight-
bracket to the detecting position with the cone points of hexagon ening the hexagon socket head cap screw (M2.5 x 6 L and M2.5 x
socket head cap screw (M4 x 8 L). 9 L) after checking the detecting position.
4. If the detecting position is changed, go back to step 2. 4. If the detecting position is changed, go back to step 1 or 3.
Note 1) When tightening the cone points of hexagon socket head cap screw Note 1) Ensure that the auto switch is covered with the mating groove by a
(M4 x 8 L), keep the tightening torque within 1 to 1.2 N·m. minimum of 15 mm to protect the auto switch.
Note 2) The torque for tightening the hexagon socket head cap screw (M2.5 x 9 Note 2) When tightening the cone points of hexagon socket head cap screw
L) is 0.2 to 0.3 N·m. (M4 x 8 L), keep the tightening torque within 1 to 1.2 N·m.
Note 3) Tighten the hexagon socket head cap screws evenly. Note 3) The torque for tightening the hexagon socket head cap screw (M2.5 x 6
L, M2.5 x 9 L) is 0.2 to 0.3 N·m.
Hexagon socket Note 4) Tighten the hexagon socket head cap screws evenly.
head cap screw
Hexagon socket head cap screw
(M2.5 x 9 L)
Auto switch (M2.5 x 9 L)

Protrusion Cone points of hexagon Auto switch


Auto switch socket head cap screw Protrusion
mounting bracket Cone points of hexagon (M4 x 8 L)
socket head cap screw
(M4 x 8 L) Auto switch
mounting bracket 2
BMB8-0S Note) Auto switch
mounting bracket 1
BA7T-0S Note)
Switch mounting rod Hexagon socket
head cap screw
(M2.5 x 6 L)

Tie-rod
Note) When the auto switch
mounting bracket is
ordered by its part Note) When the auto
number, it includes the switch mounting
bracket and screws in the bracket is ordered
dashed line. by its part number, it
includes the bracket
Auto Switch Mounting Bracket Part No. for CK Series and screws in the
(Including bracket, screw) dashed line.

Series
Bore size (mm) Auto Switch Mounting Bracket Part No. for MB Series
40 50 63 (Including bracket, screw)
CKG1 Bore size (mm)
BMB8-050S Series
CLK2G 32 40 50 63 80 100 125
Auto Switch Mounting Bracket Part No. for CA Series MDB
BMB8-032S BMB8-050S BA7T-063S BA7T-080S
MDNB (32 to 100)
(Including bracket, screw)
∗ Differences in color and glossiness of the metal surface treatment do
Bore size (mm)
Series not affect the performance. Due to the characteristics of the chromate
40 50 63 80 100 treatment (trivalent) applied to the whole body of the auto switch mount-
CDA2 ing bracket, the color may be slightly different between manufacturing
BMB8-050S BA7T-063S BA7T-080S
CDNA lots. However, this will not reduce the corrosion resistance.
1367-2
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 8

How to Mount and Move the Auto Switch

<Applicable auto switch>


Solid state ······ D-P4DWL
How to Mount and Move the Auto Switch
MDB, MDBB, MDNB 1. (For MDB)
Hexagon socket head cap screw Slightly screw the hexagon socket head cap screw (M4 x 0.7 x 8 l) into
the M4 tapped portion of auto switch mounting bracket. (2 locations) Use
M4 x 0.7 x 8 L caution that the tip of the hexagon socket head cap screw should not
Auto switch stick out to the concave portion of auto switch mounting bracket.
mounting bracket (For CDA2)
Slightly screw the hexagon socket head cap screw (M4 x 0.7 x 6 l) into
the M4 tapped portion of auto switch mounting bracket. (2 locations) Use
caution that the tip of the hexagon socket head set screw should not
stick out to the concave portion of auto switch mounting bracket.
2. (For MDB)
Put a hexagon socket head cap screw (M3 x 0.5 x 14 l) through the auto
Auto switch switch's through-hole (2 locations), and then push it down into the M3
tapped part on the auto switch mounting bracket while turning it lightly.
Tie-rod (For CDA2)
Hexagon socket Put a hexagon socket head cap screw (with spring washer M3 x 0.5 x 14
head cap screw l) through the auto switch's through-hole (2 locations), and then push it
M3 x 0.5 x 14 L down into the M3 tapped part on the auto switch mounting bracket while
CDA2, CDBA2, CDNA, turning it lightly.
CDLA, CDL1 (ø40 to ø100) 3. Place the concave part of the auto switch mounting bracket into the
Hexagon socket head set screw cylinder tie-rod, and slide the auto switch mounting bracket in order to
set roughly to the detecting position.
M4 x 0.7 x 6 L
4. After reconfirming the detecting position, tighten the M3 mounting screw
Auto switch to secure the auto switch by making the bottom face of auto switch
mounting bracket attached to the cylinder tube. (Tightening torque of M3 screw should be
0.5 to 0.7 N·m.)
5. Tighten up M4 screw of auto switch mounting bracket to secure the auto
switch mounting bracket. (Ensure that tightening torque of M4 screw
should be set 1.0 to 1.2 N·m.)

Auto switch
Tie-rod

Round head Phillips screw


With spring washer,
M3 x 0.5 x 14 L

Auto Switch Mounting Bracket Part No. (Including bracket, screw)


Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100
MDB, MDBB, MDNB BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080
CDA2, CDBA2 — BAP2-040 BAP2-040 BAP2-063 BAP2-080 BAP2-080
CDLA, CDL1, CDNA

D-

1367-3
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1368

How to Mount and Move the Auto Switch

Mounting Bracket Direct Mounting Style


<Applicable auto switch> <Applicable auto switch>
Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V), Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V),
D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NW(V), D-M9PW(V), D-M9BW(V),
D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L D-M9NA(V), D-M9PA(V), D-M9BA(V)
Reed ··············· D-A90(V), D-A93(V), D-A96(V) Reed ··············· D-A90(V), D-A93(V), D-A96(V)

How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
Cylinder tube

Auto switch mounting screw Watchmaker’s (precision) screwdriver


e

q Auto switch
Set screw mounting bracket
Auto switch M2.5 x 0.45 x 4 l
w

• When tightening an auto switch


mounting screw, use a watchmaker’s
screwdriver with a grip diameter of 5 to
6 mm. Auto switch

Auto Switch Mounting Screw Tightening Torque (N·m)


Auto switch model Tightening torque 1. Insert the auto switch mounting bracket into the auto switch
D-A9(V) 0.10 to 0.20 mounting groove to set it roughly to the auto switch mounting
D-M9(V) position.
0.05 to 0.15 2. Insert the auto switch into the attachment part of the auto switch
D-M9W(V)
mounting bracket.
3. After confirming the detecting position, secure the auto switch by
tightening the set screw (M2.5) attached to the auto switch.
4. When changing the detecting position, carry out in the state of 2.
Series MY2 Note 1) When tightening a set screw (M2.5), use a watchmaker’s screwdriver
with a grip diameter of 5 to 6 mm. Also set the tightening torque to be
When mounting auto switches, insert them into the 0.1 to 0.15 N·m. As a guide, turn 90° from the position where it comes to
cylinder’s switch groove from the direction shown in the feel tight.
drawing. After setting in the mounting position, use a flat
head watchmaker's screwdriver to tighten the provided Auto Switch Mounting Bracket Part No.
set screw. Applicable bore size (mm)
Cylinder series
12 16 20 25 32 40 50 63 80 100
BMG2 BMG2 BMG2
MY1B — — —
-012

-012 -012
BMG2 BMG2
MY1M, MY1MW — — — — — -012 -012 — —
MY1C, MY1CW — — — — — —
MY1H — — — BMG2 — — — —
-012
BMG2 BMG2 BMG2 BMG2 —
CY3R — — — -012 -012 -012 -012

Auto switch
REAR — — — — — — —
REBR — — — — — — — —
MGPS — — — — — — — —
MGP, MGPA BMG2
MGQ, MVGQ -012 BMG2 BMG2 BMG2 BMG2 BMG2 BMG2
ø5 -012 -012 -012
to MGP-A — -012 -012 -012 BMG2
ø6 -012 BMG2 BMG2
MLGP — —
-012 -012
MGF — — — — — — —
Auto switch mounting screw
BMG2
(Attached to the auto switch) MGT — — — — — — — -012
Watchmakers’ screwdriver BMG2 BMG2
RSH — —
-012

-012
— — — — —
BMG2 BMG2 BMG2
RS1H — — — — — —
-012 -012 -012

(Note) When tightening an auto switch mounting screw, use a
watchmaker’s screwdriver with a grip diameter of 5 to 6 mm. The Applicable bore size (mm)
tightening torque should be about 0.05 to 0.1 N·m. Cylinder series
125 140 160 180 200
CDQ2 (Large bore) BMG2-012 BMG2-012 BMG2-012 BMG2-012 BMG2-012
Note 2) Color or gloss differences in the metal surfaces have no effect on metal
performance.
The special properties of the chromate (trivalent) applied to the main
body of the auto switch mounting bracket for BMG2-012 result in differ-
ences in coloration depending on the production lot, but these have no
adverse impact on corrosion resistance.

1368
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1369

How to Mount and Move the Auto Switch

<Applicable auto switch> <Applicable auto switch>


Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V), Solid state ······ D-M9N(V), D-M9P(V), D-M9B(V),
D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NW(V), D-M9PW(V), D-M9BW(V),
D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L
Reed ··············· D-A90(V), D-A93(V), D-A96(V) Reed ··············· D-A90(V), D-A93(V), D-A96(V)

How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
When attaching an auto switch, first take a switch spacer between your
fingers and press it into a switch mounting groove. When doing this, confirm Switch spacer
that it is set in the correct mounting orientation, or reattach if necessary. BMP1-032
Next, insert an auto switch into the groove and slide it until it is positioned
under the switch spacer.
After establishing the mounting position, use a watchmakers flat head
screwdriver to tighten the switch mounting screw which is included.
Note) When tightening an auto switch mounting screw, use a watchmaker’s
screwdriver with a grip diameter of 5 to 6 mm. Also, tighten with a torque of
about 0.05 to 0.1 N·m
As a guide, it should be turned about 90° past the point at which tightening
can be felt.

Auto switch mounting bracket


BMG2-012

Switch spacer
(BMY3-016) 1. After picking up a switch spacer between your fingers, push it in
Auto switch mounting screw the cylinder tube groove.
(M2.5 x 4 l) 2. Confirm that it is set in the correct mounting orientation.
Accessory
Flat head watchmaker’s
screwdriver

Correct Incorrect
3. Insert an auto switch into the groove of the auto switch mounting
Switch Spacer No. bracket.
4. While keeping the condition in (3) above, insert the auto switch
Applicable bore size (mm)
Cylinder series mounting bracket into the auto switch mounting groove of the
16 20 25 cylinder to set it roughly to the auto switch mounting position.
MY3A, MY3B, MY3M BMY3-016 — BMY3-016 5. After confirming the detecting position, secure the auto switch by
tightening the auto switch mounting screw (M2.5).
MGZ, MGZR — BMY3-016 BMY3-016
Note 1) When tightening an auto switch mounting screw (M2.5), use a watch-
Applicable bore size (mm) maker’s screwdriver with a grip diameter of 5 to 6 mm.
Cylinder series Also, set the tightening torque to be 0.1 to 0.15 N · m. As a guide, turn
32 40 63 90° from the position where it comes to feel tight.
MY3A, MY3B, MY3M — BMY3-016 BMY3-016
MGZ, MGZR BMY3-016 — — Auto Switch Mounting Bracket Part No.
Note) D-M9A(V)L type cannot be mounted on MY3. (Switch spacer and auto switch mounting bracket; two kinds of auto
switch mounting brackets are used as a set.)
Applicable bore size (mm)
Cylinder series
20 25 32 40 50
MDB1 — — BMP1-032
BMG2-012 BMP1-032 BMP1-032
BMG2-012 BMG2-012
MGZ, MGZR — — —

Applicable bore size (mm)


Cylinder series
63 80 100 125
MDB1 BMP1-032 BMP1-032
BMP1-032 BMP1-032 BMG2-012 BMG2-012
BMG2-012 BMG2-012
MGZ, MGZR — —
Note 2) Color or gloss differences in the metal surfaces have no effect on metal D-
performance.
The special properties of the chromate (trivalent) applied to the main
body of the auto switch mounting bracket for BMG2-012 result in differ-
ences in coloration depending on the production lot, but these have no
adverse impact on corrosion resistance.

1369
P1355-P1372-E.qxd 08.10.3 2:48 PM Page 1370

How to Mount and Move the Auto Switch

Mounting Bracket Direct Mounting Style


<Applicable auto switch> <Applicable auto switch>
A A
Solid state ······ D-Y59 AB , D-Y69 AB , D-Y7P(V), Solid state ······ D-Y59 B , D-Y69 B , D-Y7P(V),
D-Y7NW(V), D-Y7PW(V), D-Y7BW(V), D-Y7NW(V), D-Y7PW(V), D-Y7BW(V),
D-Y7BAL D-Y7BAL
Reed ··············· D-Z73, D-Z76, D-Z80 Reed ··············· D-Z73, D-Z76, D-Z80
How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch
Flat head watchmaker’s screwdriver
Auto switch mounting nut Auto switch mounting screw (M2.5 x 4 l )
M2.5 x 4 l Accessory

ø5
Note) When tightening an auto to
ø6
switch mounting screw, use a Switch spacer
watchmaker’s screwdriver with a
grip diameter of 5 to 6 mm. Also,
set the tightening torque to be
0.05 to 0.1 N·m. As a guide, turn
90° from the position where it Note) When tightening an auto
comes to feel tight. switch mounting screw, use
a watchmaker’s screwdriver
with a grip diameter of 5 to 6
mm. Also, tighten with a
torque of about 0.05 to 0.1
N·m
As a guide, it should be
1. Insert the auto switch into the mounting groove and set it at the auto turned about 90° past the
switch mounting position. point at which tightening can
2. After reconfirming the detecting position, tighten the mounting screw be felt.
to secure the auto switch.
3. Modification of the detecting position should be made in the When attaching an auto switch, first take a switch spacer between your
condition of 1. fingers and press it into a switch mounting groove. When doing this, confirm
that it is set in the correct mounting orientation, or reattach if necessary.
Next, insert an auto switch into the groove and slide it until it is positioned
under the switch spacer.
After establishing the mounting position, use a watchmakers flat head
screwdriver to tighten the auto switch mounting screw which is included.

Correct Incorrect

Switch Spacer No.


Applicable bore size (mm)
Cylinder series
32 40 50 63 80 100
MDB1 BMP1-032

1370
2-2-48-UMASw-Shiryo.qxd 09.9.30 3:22 PM Page 9

How to Mount and Move the Auto Switch

<Applicable auto switch> <Applicable auto switch>


Solid state ······ D-M5N, D-M5P, D-M5B, Solid state ······ D-F6N, D-F6P, D-F6B
D-M5NW, D-M5PW, D-M5BW,
D-M5NTL, D-M5PTL How to Mount the Auto Switch (For HYQ, HYC, HYG)
Reed ··············· D-E73A, D-E76A, D-E80A Proper tightening torque
When tightening auto switch mounting screws, use a special tool (D-
How to Mount and Move the Auto Switch F6B-650) or a torque wrench.
The tightening torque for the auto switch mounting screw (M3) is 0.8
to 1.4 N·m.

Rail Insert a rail to the mounting


groove. Be sure to loosen
the mounting screw.

Auto switch mounting nut Special tool


(D-F6B-650)

After determining the position,


Auto switch mounting screw tighten the mounting screw.
M2.5 x 10 l (D-E7A/E8A)
M2.5 x 12 l (D-M5/M5W/M5T)

1. Insert the auto switch mounting nut into the auto switch mounting
groove and then set the auto switch at the mounting position by
sliding.
2. Put the convex part of auto switch into the auto switch mounting
groove and slide it over the nut. Use the tightening torque below when installing the
3. Push the auto switch mounting screw lightly into the switch mounting auto switch mounting rail at maintenance.
nut through the auto switch mounting hole.
4. After reconfirming the detecting position, tighten the mounting screw Screw size Tightening torque (N·m)
to secure the auto switch. (Tightening torque of M2.5 screw should M4 1.1 to 1.9
be 0.1 to 0.2 N·m.)

Auto Switch Mounting Bracket Part No. (Including nut, screw) Use the tightening torque below when mounting an
Applicable bore size (mm)
auto switch body on the mounting rail.
Cylinder
series 25 32 40 Tightening torque (N·m)
M2.5 x 12l BMY2-025 BMY2-025 BMY2-025 0.8 to 1.4
ML1
M2.5 x 10l BMY1-025 BMY1-025 BMY1-025

D-

1371