You are on page 1of 1

DESIGN OF STAIR

PROJECT : PROP. FOUR STOREY W/ ROOFDECK RES./COM. BLDG.


LOCATION : MANDALUYONG CITY
DESIGNED BY : BER
DATE : 23-Aug-2021

I. DESIGNATION : STAIR-01
II. DESIGN CRITERIA
fy = 275.8 MPa f'c = 20.68 MPa
Es = 200,000 MPa Ec = 21,373 MPa
ß= 0.85
T.W. = 1200 mm.
Span = 4500 mm.
III. DESIGN LOAD
LL = 4.79 KPa DL = 6.88 KPa
IV. DESIGN SHEAR AND MOMENT
Md = 53.98 KN-m Vd = 39.98 KN
V. p max, p min, pb
p bal = 0.037 p max = 0.028
p min = 0.005
VI. THICKNESS OF SLAB
Trial t = 150 mm c= 25 mm
d= 117 mm
VII. COMPUTED p
p= 0.015 > p min O.K.
< p max O.K.
VIII. MAIN REINFORCEMENT
Asm (req'd) = 2106.65 mm² Dia. of bar = 16 mm
spacing = 115 mm Ab = 201.06 mm²
No. of bars = 11 pcs.
IX. TEMPERATURE REINFORCEMENT
Ast(req'd) = 300.00 Dia. of bar = 10 mm
spacing = 262 mm Ab = 78.54 mm²
X. SERVICE MOMENT OF THE STAIR
Mu = 54.706 kN m> Md O.K.