Professional Documents
Culture Documents
Fault tracing
FMI 3: Checking the circuit
Fault code conditions
Abnormally high voltage or short circuit to higher volt-
age has been detected.
Possible reason
● Short circuit to battery voltage on the output.
Suitable action
1
Check the supply voltage to the sensors which have
set fault codes.
2
Check sensor cables.
Possible reason
● Short circuited signal cable to 5 V voltage, coolant
temperature sensor.
● Short circuited battery negative to 5 V voltage, oil
pressure sensor.
● Short circuited battery negative to 5 V voltage,
charge air pressure sensor.
● Short circuited battery negative to 5 V voltage, fuel
pressure sensor.
● Short circuited battery negative to 5 V voltage,
crankcase sensor.
● Short circuited power cable to battery negative.
● Short circuited signal cable to battery negative.
Suitable action
1
Check the supply voltage to the above-mentioned
sensors.
2
Check sensor cables.
103