You are on page 1of 1

Malfunctions, MID 164, MID 187 Group 30: Electrical system

Fault tracing
Fault code conditions
This segment has been configured earlier.

FMI 4, 11
Possible reason
● Open circuit in power supply to bus.
● Too low voltage detected during driving.
● Unidentified fault mode.
● Other fault than low voltage, such as high negative
voltage or overloaded bus.

Suitable action
1
Check that the input voltage 12/24 Volt, pin 1 on the
bus is correct.

2
Check that the input voltage 0 Volt, pin 3 on the bus
is correct.

3
Check the data bus in this network segment, and its
connectors and cables.

120