You are on page 1of 1

1.1.

1 Subbase
1.1.1.1 Granular material

Recommended Maximum or
Material Properties Test Method
Minimum
AASHTO T11
Gradation As per specification
AASHTO T27
Resistance to Degradation of
AASHTO T-96 less than 50%
coarse aggregates
Plasticity index AASHTO T-90 Less than 6
Fraction passing the No. 40
Liquid limit AASHTO T-89
sieve shall be less than 25
Durability test AASHTO T-104 Less than 12%
Subbase will be as per Class 3 of the MOP-001-F2002. In any case, the liquid limit
of the fraction passing the No. 40 sieve shall be less than 25 and the plasticity index
shall be less than 6. The abrasive wear percentage of the aggregates shall be less
than 40% and the CBR bearing value shall be equal to or greater than 30%.
According to ASTM D4318 ¡Error! No se encuentra el origen de la referencia.
(AASHTO T89 [48] and AASHTO T90 [49]) aggregates shall be clean, sound, and
strong, free of dust, dirt, clay, or other foreign matter.