You are on page 1of 7
INSTRUCTION MANUAL Compact size axial flow fan K25DSF1 K28DSR K28DSM K35DSM K4O0DSL K40DTL K40DSH K40DTH K45DST K45DTT K45DSL_ K45DTL K45DTH KS55DTL KS55DTH Low noise type compact size axial flow fan K25USF1 K28USR K28USM K35USM K40USL K40UTL K40USH K40UTH K45UST K45UTT K45USL K45UTL K45UTH K55UTL KS55UTH Compact size axial flow fan Low noise type compact size axial flow fan Thank you for purchasing the KDK Compact or Low noise type compact size axial flow fans. Please be sure to always follow the details of these instructions in installing and using your | unit, otherwise sudden accidents or breakdowns wil occur. Hence we strongly urge both the installer and the final user to read these instructions carefully, So that the unit can be used safely throughout its service ite 1. Installation Ca ‘® Observe the following precautions as to the place of installation and the installation procedure. notre may be shrines.) Tella nacritnio | Avid a Tocaton Talal secure] Weta a fan protection high temperatures over 40° ‘susceptible to too much [Otherwise noise and ) device like a motor over Serr Fn acapeene) | PO (Gear =") | lea rear inthe Vw, eaaker The room shall have an | Provide an access door supply port for for inspection and effective ventilation maintenance. ‘Do not use the fan in | Never install the fan the place where upside down or vertically. humidity is high. Connect the duct avoiding the following cases. () Shap (2) Bended more (3) Reduced (8) Bending near Bending‘ than once diameter the eecharge ange. atte port or suction Comecton, pot. When connecting an electric flow rate control Unit (inverter slidac. etc.) bbe sure fo check the safety of the equipment. [The motor may be burned) Do not supply power of an incorrect rating. Be careful not to wire incorrectly. x The fan is for indoor use. Avoid the location exposed to direct sunshine or rain. bse CAE Do not repeat starting and stopping. (Otherwise the fan \may deteriorate 2. Names and Dimensions of Components Dimensions (mm) Compact size axial flow fan K25DSFI Compact size axial flow fan K2BDSR K28DSM K35DSM K40DSL K40DTL K40DSH K40DTH K45DST K45DTT K45DSL K45DTL K45DTH K5SDTL K55DTH Dimensions (mm) T*Te[tyovelFie 350] 197] 22 | 248] 400] 966) 350 Wodel nusber Paris name Casing A OW. Casing 6 ‘Motor Whee Guide vanes Hanger tings see) Terminal cover Detail of hanger fittings Tr] Sr £7 tN 2] HL Avoid ode rumba K280SR K28USR AL th Avoid ode nabee K4SDST K4SUST jeans jason 470) 206/21. | 298] 450) 426] 415) eer, ro aaosh, pean a0) 206) 26 | 347] 525] 490] 480) eset Teor Tests, RAST, CAST [40 218/25, | 384] 588] 556 | S46] sso 15507 [680 2i7| 25 | #45] 673] 639) 63 K280SM K28USM K3505M K35USM K400SL K¢0USL. K4ODTL KAOUTL K40DSH K4OUSH K4ODTH K4OUTH KaSOTT KASUTT K45DSL Ka5USL KaSDTL KA5UTL K45DTH KASUTH KSSDTL KSSUTL KSSDTH KSSUTH Low noise type compact size axial flow fan Dimensions mm) K25USFI Casing A ay K2BUSR K28USM K35USM K40USL K40UTL K40USH K40UTH KAaSUST K45UTT K4SUSL K45UTL K45UTH KSSUTL K5SUTH = © ss Casing 8 Motor “oe @ 8 OL pasties sume, Dimensionsimm! Model umber alele}oletefelayi [stele 285A, K28USM 882 600| 77 | 205] 22 | 20 [248] 249] «00| 266] a50] © KssuSM [ses [606] t02| 240/215] 90 |290| 209] 460| 426] 615) 6 KADUSL, KOUTL, KeDUBH, KeOUTH 04s] 575] 137/ 341| 26 | 30 |a47] ser] ses | 401] 00] 6 AUST. KUTT KABUL, KOSUTL, KASUTH [1005] 40461 | a0] 25.5| 20 [304] abe] ss | se] 506] 10 KSSUTL, KSSUTH 1232] 413] 251 | 588] as | 30 | 445] 447] 673 | 639] 631) 10 | whee Guide vanes ange! iting Sone sty nae Sice pane! assy (Taser assy lolli: No Pans tame 1S +) Fan boy Save aspe9 ied | 1 ‘Duet a5 o 5 [Sie panel assy [1 Puasie niet Hanger fing “10 Terminai cover 11) Plastic rwet Qty ‘wade! number K2eDSR KZaUSA K28DSM K22USM KaSD5M KISUSM Ksoost kaoust. | KSODTL K4OUTL KsoDSH KeOUSH KaODTH K4OUTH K45DST KéSUST KaSDTT KASUTT KasDSt KaSUSL. KaSDTU KaSUTL Ka5DTH KASUTH KSSDTL KSSUTL en KSSH KSSUTH, 3. Maintenance Cautions Perform maintenance inspection and cleaning approximately once a year so that the fan Is operated satoly for 2 Overhauling procedure ‘3 long tia, It is recommended that the maintenance inspection should be conducted by the subcontractor of the electrician to prevent the fan from having any accidont due to damaged parts deriving tom aging and When overhauling is necessary, like in the case when the motor has to be changed, ensure long lite and safe operation of the fan. ‘observe the following procedure, (Be sure to woar gloves for safety) Reon Turn off the power suj 2. Disconnect the power supply win Motor bearing (Supposed service |ife-about 20,000 hours) + Beihai poly o t the po ipply 3. The bearing service lite depends on how it is used. Fenew the bearing every time when an abnormal sound Is heard (rare 6 ne connecting terminal or K2S0SFi ane K2SUSFt) [ Model number Dard Now-Dend_] Medel number Dand New Dena KZSDSF_ K2SUSF KASDST.KASUST eeoszz KeB0SR.K2USR | szoczz «| srouz KASDTT.XASUTT e202 KZ6DSM. K28USM | rasosuxesust, ezoszz 20372 KS5DEM, KSBUSM | KaSDTLRESUTL | | ex0zz K4ODSLR@OUSL KaSDTH X4SUTH ) AOD TL KA0UTL ezozzz SSD TL KSSUTL 20222 KsODSHKAOUSH KSSDTH KSSUTH eeoeee sonia KAODTHKAQUTH 3, Disassemble the body into each p% (Compact site axel flow ten) Follow tne sequence accoicing 1 K2SUSE! 16 cilferent from tive eanseueron Disassemble in order 1, Terminal cover 2. Hanger fitting Anoliee mocel nunoer K28USR —_K45UST K28USM —K4SUTT Ka5USM —K45USL. KaQUSL —-K4SUTL KAQUTL = KASUTH KaQUSH — KSSUTL. KAQUTH = KSSUTH 4. Plastic rivet Use a reguist screwarver Casing B assy 6. Plastic nvet Praste ret 5 (includes in package: 10 0n Casing A samy 7. Hanger fitting fo CMC Meola old (1) Trouble shooting Examine the following table to determine and rectity the problem. It the fan stil does nat work, disconnect ower source and contact to the local dealer Taase] maton | Excasave | Eacessve | Overeaies = Proser attow” | rowe*"* | Straten’ | moto femeasre Peer tourer E ° Renioce loveaton ° Fecneek installation range motor wring heen power sowee Four staan eves fan tah Contact between s0tay OE 5 5 a ec ores 2 ° © | rscecton iourtes ne WERE = b S| eke, Faulty oveind a E S Duet inapecton (2) Replacement parts kept for at least six years The company wil have available replacement operational parts for the Compact or Low noise type compact size axial tiow fans for at least six years after these models are no longer sold. Operational pars refers to those parts which are essential for maintaining the functions of the Product. (3) Complete after-sale service If you nave any questions about maintenance or other after-sale services. please inquire where you purchased your unit 5. Specifications m Pe et eee to. = eset | see sone set i (Note) 1. Valves ae species at te state pressure of 0 Pa 2. The air volume is. measured aecering to the chamber method (WIS C960) 3 Noise: suction sige-Noise level measured at 1S tom the sucbon side (Casing sige-Nowse level measured at 15m ftom the side of the fan Discharge side-Noise level measured ciagonally 1-5 fom tne discharge side “+ Nose measurement concibors ‘The suction side of the fan 1s equipped wth a belmouth and the discharge side is equiooed with a duct (20) 6 Precautions During Installation ‘@Check the following. ‘1s there any breakage ‘or deformation ® AN S)® IC WA Install the exterior duct in a slightly eclning siove toward outer side, | Install the body herizontaly. Ly EO elf any error is found, please contact the dealer you purchased from. PME ela) pe, —— Connect te creiy tt or wo easter y ng ow) pc ON ‘ Connect the rectangular duct _—~ Compact size axial flow fan \ caren pare im \ a soe | \ Cheek the ait direction referring to the name plate inseait wien = | || | the drain cor _ kh od — pic 8 Low noise type compact size axial flow fan Wiring Cautions (With silencer installed on the discharge sice) Follow the sequence according to the number described as below anserees || {fo be prepared by the user) ‘ghtered before Terminal | | | 1¥:There is no connecting terminal for K2SDSF land K2SUSF1 i 7 3. Electric Wiring Cautions Ask the electrical shop for wiring. # To the electrical shop who makes wiring ® Kindly work in accordance with the elecirc equipment engineering standards and the working standard specified by the power company # According to the electrical installation standard, perttom the grounding work @ Connect the line after opening the terminal cover Kindly connect as indicated in the following drawings ® Atter wiring, check the rotation direction @ For KSSDTL and KSSUTL. which do not have two-speed motor, connect the red, white and black lines to the R, S and T terminals, respectively wirina piacram | *H! wiric otacram| *H! | TSINGLE PHASE} - (THREE PHASE) . ean a won | FES 2a0se ES tern be pee 3 | Keepsw x — (ka | | sen | Hee war | kasost | feat | kaspst ato yl *LO K25USFI baer etd a ~\ kaSuTL Spe KasuTH K3SUSH 2e . - TH B3~ Adu ss mee ie | KausH ~ 23- KASUST cameron KaSUSL There is no connecting terminal for \ K25DSF1 and K25USF

You might also like