You are on page 1of 2
2, _____ means that equipment is not readily accessible to persons unkeos Special means for access are used. @) Isolated C. Bevated B. Guarded D, Concealed 5, A piece of electrical equipment that Is designed to operated at alternate intervals of (1) load and no load; or (2) load and rest; or (3) load, no load, ‘and rest Is called __ duty. A. short time C. periedic () intermittent D. varying 4, An electrical outlet constructed so that moisture will not enter the enclosure is assified as being A. waterproof ©vatertignt B. rainproot D, weatherproof i, The ts the current In amperes a conductor can carry continuously under the conditions of use ydthout exceeding its temperature rating. A, load connected load B. demand (0) ampacity f, Encased with a material or composition or thickness that is not recognzed by the code as electrical Insulation is defined as a covered A, cable C. wire B, conduit ( conductor + Covered, shielded, fenced or enclosed by means of ‘Suitable covers, casin barriers, ralls, screens, mats or platforms Is the definition ot ®)gvarded C, isolated U. protected D. enclosed HW The overload service conductors from the last pole or other zerial support to ind including the splices, if any, connecting ta the service entrance fonductors at the building or other structure is the A. service load @)service drop I). service lateral D, service supply Wawers: 1 (A), 2(A), 318), 4.(C), 5D), 6.0), 7.(A). 8(C) A. part of a wiring system that Is intended primarily to perform an electrical function B. pulling cable into a confined area C to be suitable or proper for D) part of a wiring system that is intended primarily to perform a mechanical function 11. Without live parts exposed to @ person on the operating side of the equipment is called @ dead front C. externally operable B. isolated D. interrupted 12. A conductor encased within material of composition or thickness not recognized by the code is a conductor, A coated covered B. semi D. fiber optic 1. means $0 constructed or protected that exposure to the weather will not interfere with successful operation, (A) Weatherproof C. Weather-resistant, B, Weather-tight D. Weather-sealed 14. The definition of automatic of self-acting, operating by its own mechansm when actuated by some impersonal influence such as A. a change in current strength C. mechanical configuration B, temperature ©) allof these 15. Only wiring methods recognized as are induded in the code. A approved ¢. ited @ suitable D. identified 16, An accessible conductor is @) not permanently endosed by a structure B. admitting close approach C. not guarded by locked doors, elevation or other methods D. being reached without use of a ladder Answers: 9.18). 10(D), 11.(A), 12(C), 130A), 14D). 18.8). 16.(A) 8B. bare c 19. The definition of a dry location _ ‘A. not normally subjected to dart B. not normally subjected to wet C. may be temporarily subjected @allof the above 20. duty is a type of service may have wide variations. A. Continuous ¢ B. Periodic ¢ 21. A requirement of service that de load and no load; or (2) load an duty. varlable « Intermittent, t 22. Continuous load is . @ a load where the maximum ¢ ‘or more B. a load where the maximum ¢ More C. intermittent operation in whic D. operation at a substantially <1 23. Concealed is . not readily visible made inaccessible by the stru C. surrounded by walls D. attached to the surface 24, ___isa system or circuit con, A. Grounding conductor 1 @ Grounded conductor \ ey Answers: 17.(C), 18.(C). 19.0}, 20.D)

You might also like