Professional Documents
Culture Documents
ELABOTrainingsSysteme
Aus- und Weiterbildung GmbH
www.elabo-ts.com
K N X I N S T A L L A T I O N B U S S Y S T E M
KNX SYSTEMS
Protective KNX
measures
Installation
technology
Lighting
technology Hazard alarm
systems
Telecommunication
Tra
ining systems
®
ELABOTrainingsSysteme
BASIC FUNCTIONS
SWITCHING
DIMMING
BINARY INPUTS
Page 6 − 9
PROGRAMMING
ETS4 SOFTWARE
ALARM CONTROL
TOUCH PANEL
Page 10 − 15
PROJECTS
DIMMING
ALARM SYSTEM
Page 16 − 19
NETWORKS
ETHERNET
DALI ETHERNET
Page 20 − 35
LOGO!
COURSWARE
MANUALS
TRANSPARENCY SETS
TECHNOCARDS
Page 42 − 43
Page 44 − 45
K N X I N S T A L L A T I O N B U S S Y S T E M
Weather station
Project: Dimming
Room Controller
Access control
4
®
ELABOTrainingsSysteme
PLC Board 24 V
with KNX extension module
5
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
LEARNING OBJECTIVES
6
®
ELABOTrainingsSysteme
KNX applications
41 221 41 222
41 223 41 224
7
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
Power supply
Bus coupler
BCU 2
Bus coupler
BCU 1
2-X button
8
®
ELABOTrainingsSysteme
System plug
for connecting the projects
2 simulation switches
connected to the
inputs of the binary input
6 simulation buttons
connected to the
inputs of the
binary input device
9
K N X I N S T A L L A T I O N B U S S Y S T E M
SOFTWARE
LEARNING OBJECTIVES
10
®
ELABOTrainingsSysteme
The KNX programming environment is used for the planning and configuration of
intelligent KNX home and building control. It supports the execution of home and
building control projects in the following phases:
1. Configuration
2. Commissioning
3. Project documentation
CD-ROM KNX
4. Diagnosis and troubleshooting Programming environment
Accessories
80 544 USB Programming Connection Line 41 002 KNX Professional Connection Line
11
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
12
®
ELABOTrainingsSysteme
Outputs only
t
er
Al
Detector group 01
Detector group 02
Detector group 80
n
tio
ec
nn
-co
N*
A/
Detector group 01
Detector group 02
Detector group 80
A/N*-connection
ec
nn
-co
N*
Detector group
A/
terminals
Detectors
*A/N=activated /non-activated
13
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
Touch Panel
LEARNING OBJECTIVES
KNX Color Touch panel 5,7"-colour TFT Up to 60 additional functions can be implemented
Mains and bus voltage connection Up to 64 scenes can be stored
10 operating pages with 5 functions each 16 alarm/event objects available
14
®
ELABOTrainingsSysteme
Conference 1 Office 1
Conference 2 Office 2
Meeting 1 Reception
Meeting 2 Kitchen
Configuration
22
-2
-10
11 :15 11 :35 11 :55 12 :15 12 :35 12 :55 13 :15
15
K N X I N S T A L L A T I O N B U S S Y S T E M
PROJECTS
Project: Dimming
LEARNING OBJECTIVES
D
Set dimming value continuously / DCommissioning and troubleshooting
switch on directly
RCD circuit breaker 40/0.03 A, 4-pole Set of KNX system cables with branching
and connecting cables
Line circuit breaker B10 A, 1-pole
Set of wiring and distribution accessories
Universal dimming actuator, 2-X, 300 W
Scene and logic module
Electronic ballast for halogen lamps with recessed 50 W
luminaire, in a system casing Binary input 2-X with 2-X push button
16
®
ELABOTrainingsSysteme
Sinusoidal voltage Phase angle control, leading edge Phase angle control, trailing edge
10 ms 20 ms 10 ms 20 ms 10 ms 20 ms
L1
L2
L3
N
17
K N X I N S T A L L A T I O N B U S S Y S T E M
PROJECTS
LEARNING OBJECTIVES
Analogue telephone gateway analogue with web server − Glass breakage sensor
− Power supply 12 V DC − Alarm distributor with sabotage monitoring
− KNX detector group terminal KNX 12 V DC with 2 detector
Distribution group inputs for several passive detectors
− small-scale distributor − KNX LCD display for displaying alarm states and for para-
meterising values
Detectors and sensors − Set of KNX system cables with branching and
− Reed contacts for door and window monitoring connecting cables
− Infrared motion detector − Set of wiring accessories
18
®
19
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
LEARNING OBJECTIVES
20
®
COUPLIN G L I N ES V I A E TH E R N E T
ELABOTrainingsSysteme
KNX LAN DSL router with VPN 1. Connect the IP router to the KNX bus
or ISDN-/analogue-
dial-in router
2. Connect the IP router to the LAN
IP router 3. Configure the VPN-DSL router or the dial-in router
Internet (via VPN-connection
KNX device or dial-in modem)
Advantages
KNX device
LAN as main and sub-area line
Data transfer over longer paths possible
Use of existing data networks and components (LAN)
21
F R O M I N S T A L L A T I O N T E C H N O L O G Y. . .
®
ELABOTrainingsSysteme
. . . TO BU I L D I N G C O M M U N I C AT I O N
K N X I N S T A L L A T I O N B U S S Y S T E M
®
1st line
Video Power Supply Board ISDN Board + KNX LOGO! KNX Programming Board Gateway Room Controller Energy Saving Lamps Board Keypad Board LAN Interface Board
TAE Connection Board Network analysis Project: Dimming Colour Touch Panel High-Pressure Sodium Lamp Board LED Effect Lighting Board Interface Board Fire Detector Board
Intercom Sub System
ISDN tester
S0-Bus Extension Board LED Lamps Board LED Control Board Access control Burglar Alarm Board
Project: Blinds
FAX machine
K N X I N S T A L L A T I O N B U S S Y S T E M
®
1st line
Video Power Supply Board ISDN Board + KNX LOGO! KNX Programming Board Gateway Room Controller Energy Saving Lamps Board Keypad Board LAN Interface Board
TAE Connection Board Network analysis Project: Dimming Colour Touch Panel High-Pressure Sodium Lamp Board LED Effect Lighting Board Interface Board Fire Detector Board
Intercom Sub System
ISDN tester
S0-Bus Extension Board LED Lamps Board LED Control Board Access control Burglar Alarm Board
Project: Blinds
FAX machine
K N X I N S T A L L A T I O N B U S S Y S T E M
®
LINE COUPLER
ELABOTrainingsSysteme
Classical topology
f
In the classical topology, all the line and area coup-
Line/area coupler N140
for area and line coupling
lers are traditionally configured as KNX couplers.
1.5.0 2.5.0
Line 1.5 Line 2.5
LK Level 5 LK
This topology is proven and used extensively. The
1.4.0 2.4.0
Line 1.4
LK Level 4 LK
Line 2.4 bus line lengths are mostly limited to one building.
1.3.0 2.3.0
Line 1.3 Line 2.3
Main line 1.0
1.2.0 2.2.0
Line 1.2 Line 2.2
LK Level 2 LK
1.1.0 2.1.0
Line 1.1 Line 2.1
LK Level 1 LK
KNX
Area 1 Area 2
(west wing) BK BK (east wing)
Area
1.0.0 line 0. 2.0.0
Modern topology
f
In this modern topology, the area couplers are repla-
IP-router N146 as an area coupler ced by IP routers X.
1.5.0 2.5.0
Line 1.5 Line 2.5
LK Level 5 LK
Owing to the use of standard network components,
1.4.0 2.4.0
Line 1.4
LK Level 4 LK
Line 2.4 the connection of e.g. two parts of a building is not
limited to bus line lengths.
1.3.0 2.3.0
Line 1.3 Line 2.3
Main line 1.0
LK Level 3 LK
1.2.0 2.2.0
Even other media like fibre optic cables or W-LAN
Line 1.2 Line 2.2
LK Level 2 LK
can be employed to couple to remote buildings and
Line 1.1
1.1.0 2.1.0
Line 2.1
to exchange group address telegrams.
LK Level 1 LK
KNX
Area 1 Area 2
(west wing) BK BK (east wing)
Data network
1.0.0 (LAN) 2.0.0
Innovative topology
f
In this innovative topology, all the line couplers are
IP router N146 as a line coupler
replaced by IP routers Y.
1.5.0 2.5.0
Line 1.5 Line 2.5
LK Level 5 LK
The use of area couplers is not necessary any
Line 1.4
1.4.0 2.4.0
Line 2.4
more. This configuration allows connecting every in-
LK Level 4 LK
dividual floor via Ethernet (LAN) and using existing
Line 1.3 1.3.0
LK Level 3
2.3.0
LK
Line 2.3 LAN networks.
1.2.0 2.2.0
Line 1.2 Line 2.2
LK Level 2 LK Moreover, through the correct configuration of the
1.1.0 2.1.0
IP router, large projects can be commissioned more
Line 1.1 Line 2.1
LK Level 1 LK
clearly and easily in the form of smaller individual
projects.
Area 1 Area 2
(west wing) (east wing)
Data network
(LAN) An exchange of group address telegrams is possib-
le despite the division into individual projects.
Y
28
Line area coupling KNX KNX
KNX KNX
Commissioning via LAN
TCP/IP
Programming
via TCP/IP
KNX KNX
Area line via TCP/IP
Switch TCP/IP
KNX KNX
KNX KNX
TCP/IP TCP/IP
Line coupler via TCP/IP
KNX KNX
29
K N X I N S T A L L A T I O N B U S S Y S T E M
Distribution panel 1
Distribution panel 2
30
®
ELABOTrainingsSysteme
Distribution panel 1
up to 40
weekly timer entries
31
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
KNX Gateway
FUNCTIONS
DTime functions:
Timer mode
Night mode
DDimming:
Brighter/darker
Brightness limitation
DSwitching:
On/Off
DEmergency lighting:
Control of self-contained luminaires
DStatus:
short-circuit
power supply
Status groups
Technical data
interface for integrating of up to 64 devices
bus voltage: approx. 19 V DC
KNX-bus connection
Mains voltage: 110 − 240 V AC, 50/60 Hz
Connection of all inputs and outputs via safety sockets (2 mm)
32
®
W H AT I S DA L I ?
ELABOTrainingsSysteme
DALI was jointly created by the leading manufacturers of control units and electronic control gears as a non-proprietary standard to
satisfy all the demands that are placed on a modern light management.
Approved by almost all luminaire and control equipment manu- always been in the focus. As an interface standard, DALI pro-
facturers, DALI has become the new standard in lighting industry. vides the means to configure complete light management sys-
DALI was designed mainly for room lighting control. tems for rooms such as DALI room controllers or KNX-DALI
Ease of use of the lighting systems and their components has gateways.
33
K N X I N S T A L L A T I O N B U S S Y S T E M
34
®
ELABOTrainingsSysteme
ELABOTrainingsSysteme
35
K N X I N S T A L L A T I O N B U S S Y S T E M
HARDWARE
D
Time recording via DCF 77
36
®
ELABOTrainingsSysteme
Temperature sensor
Value range: -40 – +80° C Address: 3/6/33
[kLux]
[Lux]
Brightness sensor
20 Address: 3/6/20
20
Object number Sunshine
37
K N X I N S T A L L A T I O N B U S S Y S T E M
LO G O !
LEARNING OBJECTIVES
Integrated display panel with backlighting and operating panel with buttons
Modularly expandable
38
®
ELABOTrainingsSysteme
63 526 24 V DC Power Supply Board 2.5 A E40 804 Industry user manual LOGO!
39
K N X I N S T A L L A T I O N B U S S Y S T E M
T E C H N O LO G Y M O D E L
Blind
Table model of a blind in a transport frame. Connection is achieved via a common blind or roll-down shutter actuator.
The following functions are possible with the technology model 'Blind':
Blind movement
Slat adjustment
Positioning
Safety function
Technical data
Operating voltage 230 V AC
40
®
ELABOTrainingsSysteme
B
Blind
41
K N X I N S T A L L A T I O N B U S S Y S T E M
COURSEWARE
Practical experiments
Printed and digital! Practical experiments for the trainee or the student equal to
the trainer part, with tasks, but without solutions.
KNX KNX
Installation Bus system Installation Bus system
E41 235CD Manual, Trainer Part KNX E41 236CD Manual, Practical Experiments KNX
42
®
ELABOTrainingsSysteme
Transparency set
®
Applications
KNX Toolsoftware
Example solutions
KNX
Components European
Installation Bus system
KNX Zielsetzungen
KNX objectives
Tasks of KNX:
Aufgaben der KNX:
- Certification of products
=HUWLIL]LHUXQJYRQ3URGXNWHQ
and training centres
XQG6FKXOXQJVVWlWWHQ
- Assigning trade marks
:DUHQ]HLFKHQYHUJHEHQ
- Assuring quality
4XDOLWlWVLFKHUQ
- Securing compatibility (EIS)
.RPSDWLELOLWlWJDUDQWLHUHQ(,6
- Uniform standard KNX
(LQKHLWOLFKHU6WDQGDUW.1;
Transparency set
ELABO7UDLQLQJV6\VWHPH
ELABO7UDLQLQJV6\VWHPH Version 4.1 – Cat. no. E41 237
Aus- und Weiterbildung GmbH
1
Software TECHNOCard
ktor
Bedienelemente Jalousiea
Lage der Anzeige und
tor
Bedienelemente Schaltak
abegerät Lage der Anzeige und
Bedienelemente Binäreing
Lage der Anzeige und
emente USB Schnittstelle
Lage, Funktion und Anzeige der Bedienel
Database collection
4-fach
Taster 2-fach / Taster
KNX/EIB
Systemstecker
Busankoppler
BCU 2
UP114
6 Simulationstaster
angeschlossen an
Busankoppler die Eingänge des
BCU 1 Binäreingabegeräts
UP110 S1-A
S2-B
S3-C
S4-D
KNX/EIB S5-E
4-fach Tastsensor S6-F
UP287 DELTA style
ELABOTrainingsSysteme
Aus- und Weiterbildung GmbH
ACHTUNG!
TECHNOCard ®
Beachten Sie beim Aufbau und bei
Im Hüttental 11 der Erprobung der Anlage alle erfor-
85125 Kinding - Germany
Tel.: + 49 (0) 84 67 / 84 04 - 0 derlichen Sicherheitsbestimmungen,
Fax: + 49 (0) 84 67 / 84 04 44 die Laborordnung und die erforderli-
4.2
E-mail: info@elabo-ts.com
www.elabo-ts.com KNX/EIB Professional Programming Board chen Schutzmaßnahmen!
41 233
43
K N X I N S T A L L A T I O N B U S S Y S T E M
I N F O R M A T I O N A N D C O N S U LT A T I O N
CONSULTANCY
Turnkey projects
CONTACT
ELABOTrainingsSysteme GmbH
Service-Center
Im Hüttental 11
85125 Kinding / Germany
Tel.: + 49 (0) 84 67 / 84 04 - 0
Fax: + 49 (0) 84 67 / 84 04 44
sales@elabo-ts.com
www.elabo-ts.com
44
®
ELABOTrainingsSysteme
EXPERIENCE
References worldwide
- Industrial training institutions
- Vocational schools / technical schools
- Chambers of crafts
- Technical colleges
- Universities / Universities of Applied Sciences
WE ASSIST YOU
Technical support
45
K N X I N S T A L L A T I O N B U S S Y S T E M
46
®
YO U R I N Q U I RY
ELABOTrainingsSysteme
Name, Position
ELABOTrainingsSysteme
Aus- und Weiterbildung GmbH Company / Institution / Government agency
Telephone Fax
We would like to be contacted:
Fby telephone Fby e-mail E-Mail
47
K N X I N S T A L L A T I O N B U S S Y S T E M
®
ELABOTrainingsSysteme