You are on page 1of 2

Data Sheet

Amplaid A137 and A177 Plus


Compact portable audiometers with large memory capacity
from screening to clinical testing and free field

A137 diagnostic audiometer A177 Plus two channel diagnostic


• Manual audiometry by AC and BC (steady and pulsed audiometer - Speech - Free Field - ABLB
pure tones and Warble)
• Pure tones, Warble and Speech by AC, BC and FF,
• Automatic audiometry with Autothreshold test Automatic Audiometry and ABLB (Fowler)
• 11 pure tones frequencies. User-programmable • Masking (contra and ipsi): NBN, WN and SN by AC,
selected range BC, Insert and FF
• Masking noises: NBN and WN by AC, BC and Insert • Internal data storage: 128 patients (AC-BC both ears)
both contra and ipsilateral
• Free Field outputs. Inputs: pure tone, Warble, Speech
• Internal data storage: up to 128 patients (AC and BC) (two separate channels), NBN, WN and SN.

Main features
• User-friendly intuitive control panel • AC transducers: TDH49 or E.A.R.Tone 3A
• Ample LCD: 4 lines of 20 characters • B71 bone vibrator
• Compact and light-weight (1950 gr. - 4.3 lbs.) • Noise enclosures
• Small: cm 36 (14”) w x 28 (11”) d x 12 (5”) h • Soft carrying bag: elegant, for all accessories
• Pre-set test parameters for rapid testing • Printer (external): portable, graphic and alphanumeric
• User-programmable parameters • Data transfer: single patient file or entire database
• Masking available also by insert phone • A.S.A. software for Patient Data Management
A137 and A177 Plus New portable audiometers

New Amplaid portable audiometers


Advantages Technical data A137 A177 Plus
• Preset test parameters, saving precious operator time, AC frequency range 125 - 8000 Hz 125 - 8000 Hz
can be user-programmed and permanently saved. AC max. output (TDH49) 120 dB HL 120 dB HL
• A177 Plus battery of clinical tests includes recruitment
AC max. output (ER-3A) 110 dB HL 110 dB HL
testing (ABLB), binaural Speech and Free Field option.
Attenuator intervals 5 dB 1,2 and 5 dB
• A177 Plus Free Field testing includes pure tones,
Warble, binaural Speech (live voice and 2 separate FF maximum output 95 dB HL
external inputs) as well as noises (NBN, WN, SN). BC frequency range 250 - 8000 Hz 250 - 8000 Hz
• Aided and unaided Speech testing can be performed BC maximum output 80 dB HL 80 dB HL
for hearing aid fitting. AC Speech (TDH49) 105 dB HL
• Any number of items in the speech list can be user- AC Speech (ER-3A) 100 dB HL
programmed. BC Speech max. output 60 dB HL
• A137: AC-BC with masking and automatic audiometry
FF Speech max. output 90 dB HL
make it ideal for hearing conservation programs. Also
AC NBN maximum output 95 dB HL 95 dB HL
features user-programmable frequency range.
BC NBN maximum output 100 dB HL 100 dB HL
Data storage and transfer FF NBN maximum output 95 dB HL
• Internal database: up to 128 patients both AC and BC
AC WN & SN max. output 90 dB HL 90 dB HL
thresholds, both ears.
• External storage in PC hosting Noah 2.02 and Noah 3.0 BC WN & SN max. output 90 dB HL 90 dB HL
compatible modules and A.S.A. Patient Data Management FF WN & SN max. output 95 dB HL
• On-line transfer of single patient files and off-line transfer
of entire database to PC hosting A.S.A. Accessories A137 A177 Plus
• A.S.A. database includes tympanometry, AEP, patient TDH49 included included
data and history. It operates in Windows ® environment EARTone ER-3A optional optional
as single station and in network.
Peltor noise enclosures on order on order
External printer ADC noise enclosures optional optional
• Optional alphanumeric and graphic printer: light- weight, Patient handswitch included included
battery operated, with adapter.
Power cable included included
• Paper: thermal, 10 cm w (4”).
Instruction Manual included included
Main characteristics BC vibrator, B71 optional included

Audiometer type A137 Single insert phone optional optional


A177 Plus
Operator monitor phones included
EN 6O645-1 (1994) 3 2
Operator microphone optional optional
ANSI S3.6 (1996) 3 2A
Goose-neck operator mic optional optional
Tests A137 A177 Plus Patient microphone optional
AUDIOMETRY Pure tone and Warble, Printer optional optional
manual and automatic steady and pulsed Ext. Free field 2-channel amplifier & optional
two speakers
by AC, BC AC, BC, FF
A.S.A. Patient Management SW optional optional
Masking: signals NBN, WN NBN, WN, SN
NOAH Modules included included
AC, BC, AC, BC, FF
outputs Carrying bag optional optional
Insert phone Insert phone
AUTOTHRESHOLD Automatic threshold by AC Standards A137 A177 Plus
SPEECH AC, BC, FF Audiometry EN 60645-1 (1994), ANSI S3.6 (1996),
EN ISO 389 (1995)
ABLB (Fowler) Automatic A177 Plus only: EN ISO 389-7 (1996)
Safety EN 60601-1 Class I Type B (1990);
Synchronous masking included included EN 60601-1-1 (2001)
Locking of channels included included EMC EN 60601-1-2 (1993)

Weight / dimensions A137 A177 Plus


Weight, grams (lbs.) 1950 (4.3) 1950 (4.3)
Dimensions, cm (inches) 36 (14”) w x 28 (11”) d x 12 (5”) h