Harman Music Group
Engineering Change Notice
Date: 8FEBOS Project #: 512
Product: dox PA,-EU, -B
Assy. Name: IC AM29LV040B
Assy. Number: 72-539-03V1
Revision: 01___To: 10
Project Engineer: Dan Burdeite
ECN# 3014le
‘Reason For Change: Software upgrade, Added wizard for Crown amps, fixed bo bug,
updated amplifier tables.
Tastructions:
Update system flash software from 72-$539-03V1.010 to 72-$539-03V1.100,
TECNH April 21, 198
feet #2=* Delete **** Quantity ae Add Hee ‘Quantity
Tem Description Item # [From | To Item Deseription Tem# [From | To
‘Reason for Change ‘Reason:_[ Effectivity /Priority | Priority: | Signatures Date
Continuous Improvement @CI | After Depletion of Current) ADC
Cost Reduction CCR | Next Job Release ONIR
Component Substitution OCS or Friday of Men)
Marketing Change GMC | Rework Parts
Manufacturing Release QMR | On Order Roo
Omission or Error Qoe | instock Oris
Product Enhancement — @PE_—|_in Process arp
Regulatory Requirement QRR | in Finished Goods ORF
Software Update @su Other: QoTH
Specification Change SC
Other Gorn
rag tte Cost—S- Bie ECN Distribution
Dist STD; Engineering Files, Materials, Manuf Eng, Manufacturing, Stockroom, SlesiCustomer Service, Techical Service, Product Devclopment, Pro. Fngineer
BeDriveRack PA Software Release: V1.100
Date: February 8, 2005
Product: dbx DriveRack PA
Part Number: 72-5539-03V1 Rev. 10
Previous Software Version: 1.010
DriveRack PA File Names: 25110001.H01, 23110001802, 2311000103, 23110001.404,
2311000105, 23110001 H06, 2311000107, 23110001 ho8
DiiveRack PA Check Sum: OxCOBE
AA
DSP Eng.
RexReed
Softvare Eng.
Sper Sni
AP Tester
vid
DriveRack PA Additions to V1.010:
1, Wizard support for the following Crown Amplifiers:
Xs500
Xs700
Xs900
Xs4300.
2. Wizard support for the following IBL speakers:
SoundFactor SF12M
RX 112M.
RX 115
IRX 125
JRX 1188 (Sub)
IRX 118SP (Powered Sub)
SRX 712K
SRX 715K
SRX 722
SRX 725X
SRX 738X
SRX 718 (Sub)
SRX 728 (Sub)
oe PA Bugs Fixed in V1.010:
Get _initial_amp_level() fixed to accommodate negative number in the amp tables as per initial fix
in DriveRack 260,
2. Modify_amp_selection() fixed as per initial fix in DriveRack 260. If an amp selection is changed,
the amp->sensitivity is reset to zero before resetting the initial amp level.
a DrriveRack PA-Changes.to V1.01 05
1, Changes to the following amplifier tables as per latest values in the DriveRack 260:
Crown PowerTech 1.1 (0.775 Volt Sensitivity and 1.4 Volt Sensitivity)
‘Crown PowerTech 2.1 (1.4 Volt Sensitivity)
Crown KI (1.4 Volt and 264B Sensitivity)