PRODUCT SPECIFICATIONS FOR P22-1 GENERATOR SET SPECIFICATIONS Minimum Rating Maximum Rating EmissionsFuelStrategy 50 Hz Prime 50 Hz Standby 60 Hz Prime 60 Hz Standby Frequency Speed Voltage 50 Hz Prime Rating 60 Hz Prime Rating 50 Hz StandbyRating 20 KVA/ 16 kW 22 KVA/ 17.6 kW Fuel Optimised 20 kVA/ 16 kW 22 kVA/ 17.6 kW. eye Ey 50 He 1500 RPM 220-415 Volts ‘Theseratings are applicable for supplying continuous electricalpower (at variable load) in lieu of commerciallypurchased power. Thereis no limitation to the annual hours of operation and this, model can supply 10% overload power for 1 hour in 12 hours, Thesetatings are applicable for supplying continuous electricalpower (at variable load) in the eventof a utility power failure. No overload is permittedon theseratings. Thealternatoron this model is peak continuous rated(as definedin ISO 8528-3) Standardreferenceconditions 25@C (77 @F) Air Inlet Temp,100m (328 ft)AS.L 30% relative humidity. Fuel consumptiondataat full load with diesel fuelwith specific gravity of 0.85 and conforming toBS2869: 1998, Class A2. ENGINE SPECIFICATIONS EngineModel Perkins® 4044-2261 Bore 84 mm (3.3 in) Stroke 100 mm (39 jin) GovernorType Mechanical Displacement 2.21 (1352 cu. in) CompressiorRatio 23.31 P22-1 STANDARD EQUIPMENT ENGINE Air Cleaner Lube oll drain vaive Engine filed with lubrication oil High Coolant TemperatureShutdown Low Oil PressureShutdown COOLING Packagemountedradiator Radiator& Cooling Fan Coolant Drain Valve Fan, Fan drive and batterycharging Alternatordrive fully guarded to meetEC Machinery Directive Cooling Systemiflled with Coolant mix EXHAUST Exhaust flange outlet Exhaust stub pipe and gasket FUEL, 8Hr Fuel Tankor Skidbase Fuel Fittings for Local and RemoteFeed ALTERNATOR FG Wilson Alternator ‘SHUNT Excitation 1P23 Protection CONTROLPANEL DSE4520 F100 MOUNTING. Skid base,Formed Steel Base, Formed Steelwith Skid base or Single wall Fuel Tank CertifiedBase Mounted Lifting Eyes,and Rear Drag Eyelets Antiviibration mounts BatteryTrayand Cables P22-1 OPTIONAL EQUIPMENT EXHAUST Industrial, Residential,Critical Silencers ALTERNATOR Leroy Somer Alternator QuadratureDroop Kit ‘Anti-CondensationHeaterand Panel Circuitry CONTROLPANELS DSE4520 DSE7320 DSE7410 Deep Sea DSE7420 GENERAL 8 Hour, 600L, 1000L, 2000L fuel tanks Upgrade to StandardSet for CE" Certification EEC Declaration of Conformity Narrow, Wide or Skid Base Sound attenuatedsteelor galvanised enclosure Dual wall fuel tanks STARTING/CHARGING Lead Acid battery(Dry) ENCLOSURE Compliance to European Community Directive 2000/1 4/EC Super sound attenuationfor residentialareas Totallyenclosedexhaustsilencing system Robustand highly corrosion resistantconstruction

You might also like