(3) In order to prevent entering of noise, use shielded wire or twisted wire for control signal line.

(4) In case that speed is set at outside of control panel, lay signal line containing in the conduit pipes or metallic pipes.
(5) As to wire size of main circuit wiring, see [Input/Output devices and wiring] of Chapter 4, item 2.
(6) In case that shielded wire is used for output wiring or wiring length is over 300m and when ED64sp Inverter is operated
by its DC excitation function, there may be a case that Inverter is broken or it does not work normally caused by leaka-
gecapacitance to earth of output wiring of Inverter and resonance phenomenon of input power source inductance. In
such case please contact us.
Chapter 2 For operation of ED64sp

20
Even if torque command is constant, output torque lowers, Even in constant output area, output torque is constant if
being inversely proportional to the speed, in order to make command is constant. (Torque limiter lowers for making
the output constant in the constant output area. the constant output.)
Function to confirm internal data of Inverter by analog or console display, by setting of internal address of CPU. (This
function is for our test and for special application. Keep initial values ordinary).
Ý

http://www.toyodenki.co.jp/
HEAD OFFICE: Tokyo Tatemono Yaesu Bldg, 1-4-16 Yaesu, Chuo-ku,
Tokyo, Japan ZIP CODE 103-0028
TEL: +81-3-5202-8132 - 6
FAX: +81-3-5202-8150

Contents of this manual are subject to change without notice.