You are on page 1of 1
Tanggun Expansion Project ~ LNG EPC C3: Existing construction Jotty ~Design check 3.6 Loads 3.6.1. Soil weight The earth pressure due to retaining soil self-weight is @ computed by the software regarding the densities and the friction angle of the materials 3.6.2 Live loads Based on Ref{1] we have considered 2 types of live loads - a.uniform live load of 31/m? over all quay section - @crane load acting only at finger piers considered as an outrigger pressure. ‘The 150 tons crane has a maximum outrigger pressure of 95T/m ‘The crane will operate only at the middle of the Finger piers on areas with paving, ——_a__- @ @ @ & a Figure 11 : Crane outrigger loads position With a =3.5m, and s =8m; B =15m Considering the width spreading in front of quay we will applied a Boussinesq loads of 28.5T/m? as ‘computed here below: [3-Crane Loads - 150 tons 95.00 T/m* : ; 3500 m peo 100 om ‘ : jwidth 3330 om i Design P 28.5 T/m* ] K-REA loads 285 KN/ml/ml 4 3.00 ace Figure 12 : Crane loads on front wall Note we believe the crane loading described in the original design report is too conservative and therefore we have revised it to @ more realistic load distribution, TEP-S30-CALMN-BP4-0005 Page 14 0f31 “Rev: AO? © BP plc BP Internal

You might also like