You are on page 1of 1
roviewearotlimacin NPTEL » Design of Reliforced Concrete Structures ——— — Unit 11 - Week 9 Cours oxting Assignment 9 ‘eae dete forsunmitng ts ssgnment hs essa Due on 2019-10-02, 23:59 IST. As per ourrecores you have not submtea hs essgnment. ow to acess te porta Week Assignment Wook 1 Indesign of a footing. the depth considering bending moment is checked at 1 point oI (@) The free end of footing wees (Face ofthe column GA distance d2 (half of the effective dept rom the face of te eofamn Wook 4 (AA distance d (effective depth) fom the face ofthe column weet © woes o ° woot 7 @ ‘Accents nwo weak o ta 2 one a cof. footing, the depth by considering one-way shear is checked at 10m Orr or (@) The fice end of footing (b) Face of the columa ass fesanmeat (©)A distance d/2 (half of the effective depth) fiom the fase ofthe colina " (d) A distance d (effective depth) from the face of the column « weet » © Week 12 @ pounsos woos osname ‘Accented Aree: Assignment Suton o 9) In design of footing. the dept by considering two-way shear is checked at om (a) The five end of footing (b) Face of the column, (6) A distance 4/2 (balf ofthe effective depth from the face of the column (2) A distance d (effective depth) from the face of the column « » © o to, anaweria inate Seon ‘Aecenteg Aree: e © In design of isolated footing the minimum percentage of steel (HYSD) provided should be pom (6) 012% of overall rossetional area 8) 88% (©) 08% of overal cross-sectional aca “whore i the charscteristi strength of reinforcement in Nina? (4) 1% of overall cross-sectional area & o © @ te, sneer ini. ‘Accented Aree: a ©) A rectangular isolated footing of size 2100mm ~ 3100mm is made to transfer the characteristic pont load, P = SOOKN and M = 40kNm to the ground. Consider weight of footing as 10% of the characteristic axial load and the moment is acting along the length of the footing. The minimam pressure uader the foundation will be developed as (a) 134k? (b) 154m? () 185m? (@ 210i? sees on reverse econo newer: a ©) A seotangular isolated footing of size 2100mm » 3100nmn is made to teanefer the characteristic pom load, P = S00KN and M=40lNim to the ground, Consider the weight of footing as 10% of the characteristic axial load and the moment is ac along the length of the footing. The maxinmm pressure under foundation will be developed as (@) 744i (0) 110k? (6) 1388? (2) 1848 im? @ o © @ t,t anor isicore. Acceptes Anewer: e 7 A square isolated footing for a square column of size 300mm » 300mm is made to transfer the 1 point characteristic load, P = SOOKN to the ground, Consider weight of footing as 10% of the characteristic axial load, The safé bearing capacity of soil is 155 RN/nr, The dimension of the quate footing should not be less tha, (@) 956mm (©) 134m (©) 19120 (@) 2390mm « » © @ te, anomeric. ‘Accented Aree: @ ©) An isolated footing of size 2100mm3100mm is made to transfer the characteristic load, P= pom 'SSOKN to the ground. Consider weight of the footing as 10% of the characteristic axial load. The than ‘fe bearing capacity of soil chould not be (@) stein? (b) 86 An? (©) 1188Nint (@) Lasker? « o ° on rower scat econo newer: o 8) & square isolated footing (size: 1900mm.1900mm) is made for a square cohumn of size 1 point 300mm<300mm to trsfer the clamnctetitic load, P ~ 8254 to the ground, Consider weight of the footing as 10% of the characteristic axial load, The load faetor i taken ae 1.5. The oil reaction for limit state design is equal to (2838 ) STN? (©) ATW (4) S6okin? @ » © o ne newer incomet ‘copie Anewors o 10) A square isolated footing (size: 1900mm1900mm) is made for a square column of size ‘oi 300mm 300mm to transfer the characteristic load, P= 82SKN to the ground. Consider the weight ofthe footing as 10% of the characteristic axial load, load factor as 1.5 aud the overall depth of the footing 25 440mm. The clear cover for the footing is 40am and the diameter of the reinforcement provided is 12mm, The one-way shear foree due to soil reaction atthe requined section for design will be equal to (@) L1SKNim wide (&) LSSENam wid, (©) 191N an wide (4) 280KN'am wid @ > © @ ‘econo Anewor o

You might also like