Calculated Solar Reflectance Indices (SRD) Report
‘Test Number: RD132402SI Date of Test: September 2, 2013
Specimen Number: 1794130830-26,28 Date of Manufacture: Unknown
Description of Test Specimens: Coolshield; SOLACOAT Waterbased Gloss Coatings.
‘Test Method: ASTM 1980-11, “Standard Practice for Calculating Solar Reflectance Index of
Horizontal and Low Sloped Opaque Surfaces”.
Report Prepared For: Coolshield International Pry, Ltd. /Mr. Les Crampton
Measured solar reflectance and measured thermal emittance were used to calculate Solar
Reflectance Indices (SRI) in accordance with ASTM E 1980-11 for three Coolshield
SOLACOAT specimens. The Coolshield SOLACOAT specimens were tested for thermal
emittance and solar reflectance. Test reports for the solar reflectance at air mass 1.5 and the
thermal emittance are attached. The calculated SRI for low, medium and high wind speed is listed
below.
Results
SRI
‘Specimen dentification Reflectance Emittance “Low Wind MedWind High Wind
Number
1794130830-26 SOLACOAT "Cream" 0849 0.886 105.9 106.1 106.2
1794130830-27 SOLACOAT "Terracotta" 0.405 0.889 448 454 46.0
1794130830-28 SOLACOAT "Charcoal" 0.247 0.885 23.7 24.6 254
2
Don lt: 96-13
David W. Yarbrough, PhD, BE Date
Page 4 of 4@x.
Services
P.O. Box 2400
Cookeville, Tennessee 38502-2400
Phone: 931-372-8871
Fax: 931-525-3896
Solar Reflectance Test Report
Test Number: RD132401SR Date of Test: September 2. 2013
Spocimen Number: 1794130830-26.28 Date of Manufacture: Unknown
Description of Test Specimens: Coolshield; SOLACOAT Waterbased Gloss Coatings.
Test Method: ASTM C 1549-09, “Test Method for Determination of Solar Reflectance Near
Ti Poriable Solar Ref ca
Report Prepared For: Coolshicld Internstional Pty, Lid. / Mr. Les Crampton
Procedure
‘The measurement of solar reflectance in accordance with ASTM C 1549-09 was completed using
a solar reflectometer built by Devices and Services Company. The reflectometer was calibrated
using standards with reflectance 0.0 and reflectance 0.823 prior to use. The solar reflectance
‘measurements were madc in a conditioned laboratory space. The solar reflectance was measured
at air mass 1.5
R&D Identification Specimen Description Average Reflectance Standard Devi
179413083026 SOLACOAT “Cream” osa9 6.001
1794130830-27 SOLACOAT “Terraotts” 0.405 002
179413083028 SOLACOAT “Charcoal” 0.247 0001
_ Mga _ ogi ateeenuaecnee
Reviewed By: Date:
Page 2 of 4@x
Services
P.O. Box 2400
Cookeville, Tennessee 38502-2400
Phone: 931-372-8871
Fax: 931-525-3896
Total Hemispherical Emittance Test Report
Test Number: RD132400HE Date of Test: September 2, 2013
Specimen Number: 1794130830.26,28 Date of Manufacture: Unknown
Description of Test Specimens: Coolshield: SOLACOAT Waterbased Gloss Coatings.
Test Method: ASTM C 1371-04a(2010)el, “Test Method for Determination of Emittance of
‘Materials near Room Temperature Using Portable Emissometers”,
Report Prepared For: Coolshield International Pty, Ltd. / Mr. Les Crampton
Procedure
‘This report presents the results of the test specimen identified above using a Model AE
emissometer manufactured by Devices and Services Company of Dallas, Texas. The
cmissometer is powered to provide warm-up prior to use. A warmup time of one hour in a
conditioned laboratory has been found to be acceptable. Calibration at high and low emittance is
performed after the warm-up petiod using calibration disks supplied by Devices and Services
Company. Test specimens are placed in good contact withthe thermal sink that is part of the
apparatus. drop of distilled water between the test specimen and a thermal sink was used to
improve the thermal contact. The measurement head ofthe emissometer is placed on the test
specimen and held in place atleast 90 seconds for each measurement. The emissometer was
calibrated prior to use and calibration was verified at the end of testing. The average emittance
reported below is based on three measurements.
R&D Identification Specimen Description IREmittance ‘Std Dev
1794130830-26 SOLACOAT “Crean” 0.886 0.001
1794130830-27 SOLACOAT “Terracotta” 0.889 0.002
1794130830-28 SOLACOAT “Charcoal” oes 0.001
Uncersainty
The 95 % reproducibility as stated in Section 10 of ASTM C1371-04a is 0.019 units.
_ Sent Tay _
Reviewed By: