You are on page 1of 4
(cPce0_FHI7EL. OMICRON Calibration Report OMICRON Calibration Report cpceo None Type options SerialNo : FHI76L Test Date : 08, November 2018 Test Engineer : Martin Riedmann Testprogram Version : 2. Report Version : 1 This certifies that the above product was calibrated in compliance with a quality system registered to ISO 9001, using applicable OMICRON procedures. Traceability Information: Traceability is to national standards administered by the Euromet members (OKD, DKD, NPL, PTB, BNM etc.) or other recognized standard laboratories. Some measurements are traceable to natural physical constants, consensus standards or ratio type measurements. Supporting documentation relative to traceability is available for review by appointment. This report shall not be reproduced, except in full, without prior written approval of the calibration facility. Suggested next calibration date: One year from date of issue. Test Equipment: Description Type ID-No Due date Uncertainty HP/Multimeter © HP3458A 14-148 10.07.2019 Voc: Agilent/PweSre HP6834B 01-126 Tinsley/Shunt 1682 04-112 02.02.2019 Omicron/Testbox PG63 01-129 11.12.2018 ‘COMIGRON electronics GmbH 2016-11-08 4 cPC80_FHI76L Table of Contents TER Ut nronnonn 1.1 Test Ext. Booster... 2 USB Port. 2.1 Test of USB Port 3 Appendix. LOMICRON Calibration Report REwoe ‘GOMIGRON elecronics GmbH 2018-11-08 Wa cPC80_FHIT6L LOMICRON Calibration Report check of various user controls Startbutton is . oK Notaus is OK Safety key is oK check of various user controls Passed 1 Ext Out 1.1 Test Ext. Booster Test: EXTOUT-I Output - current range 30A AC linearity Actual Measured ClassErr [Al fal 10.0043 10,0014 0.014 20.0034 20.0003» 0.011 25.0030 25.0001 0.009 Test: EXTOUT-I Output - current range 30A phaseoffset Expected Measured C1 v1 0.0000 0.0121 0.0000 +0068 0.0000 0.0460 2 USB Port 2.1. Test of USB Port Writing testfile and reading it back via USB: ok All Tests passed succesfully ‘COMICRON electronics GmbH 2018-11-08 3a cpcso_FHITEL OMICRON Calibration Report 3 Appendix Environment Ambient conditions during calibration Temperature: 23°C + 3°C / 73.4°F + 5.4°F 7 Humidity: Rel. humidity 10 90%, non-condensing General definitions bur Device Under Test (CMC, CPC, ...) Nominal, Nom DUT output: programmed output of the DUT. DUT input: programmed output of the external source Measured, Meas Value measured by the DUT Actual, Act Value measured by the traceable test equipment Error, Err DUT output: calculated DUT input: calculated (Actual - Nominal) (Measured - Actual) Rel.Error, Relerr DUT output: calculated DUT input: calculated (Actual ~ Nominal) / Nominal (Measured - Actual) / Actual Class Error, ClassErr DUT output: calculated DUT input: calculated (Actual - Nominal) / Full Range (Measured - Actual) / Full Range Specification, spec Allowed deviation according to the manual; only noted if applicable Of Specification, ofSpec calculated as: (Error / Specification) in & error in $ of allowed deviation; only noted if applicable DUT specific definitions PF potential free mode of binary input (threshold defaults to 2.5 V) THDWN Total Harmonic Distortion + Noise ise ‘SOMIGRON elecronics GmbH 2018-11-08 ry

You might also like