You are on page 1of 1

Procedure for Online CIP (Clean in Place) for Membrane Fouling.

1. We have to empty the Aeration tank (in that 20% Sludge Drain water should be
taken and stored in another movable storage drum ) other 80% Send to Sludge
dry bed or direct drain to Plantation Stream
2. After emptying the Aeration tank Fill the Aeration tank with fresh water to the
top of the membrane stack
3. After filling up the aeration tank with fresh water turn the aeration on (turn on
the blower with manual mode from Control Panel) for 2Hrs.
4. After 2Hrs turn off the blower and again drain the water from the aeration tank
(Empty Aeration tank)
5. Again fill up the Aeration tank with fresh water and add 20 Litres of 10% Hypo
chemical.
6. Then after turn on the aeration for 3-4 Hrs and keep the membrane in water of
hypo solution for 12 hrs.
7. After 12 Hrs Drain the tank (Empty the tank)
8. Then add the 20% Sludge Drain water which we have stored in a movable
drum in to the aeration tank and fill the remaining tank with the fresh water.
9. After addition of the 20% water and remaining with the fresh water kept the
water for 3 Hrs with Aeration
10.After 3 Hrs turn on the Plant in the Auto Mode and set the Permeate flow as
800 LPH
11.After that daily dose Hypo Chemical 100 gm in the Back-wash tank and weekly
remove the extra sludge as SVI increases from 30%.

After the Whole process if any problem arises then Call us on :( +91)
9924522279

You might also like