You are on page 1of 3

9/18/2018 Print Page - Turbidity sensor coding

Arduino Forum
Using Arduino => Programming Questions => Topic started by: robywhite on May 06, 2016, 05:17
am

Title: Turbidity sensor coding


Post by: robywhite on May 06, 2016, 05:17 am

How to write turbidity sensor coding for arduino??can someone help me..

Title: Re: Turbidity sensor coding


Post by: Koepel on May 06, 2016, 06:01 am

They are 12 euros at AliExpress.


G = GND
A = analog output
D = digital output, the switching point is set by the potentionmeter.
V = 5V, 30mA

Use a 5V arduino board, and read the analog signal. Try the sensor in clear and dirty water and see what
values you get for the analog value.

Title: Re: Turbidity sensor coding


Post by: zhomeslice on May 06, 2016, 06:09 am

hook you Analog output form the sensor to Arduingo A0 and Ground to G provide power, open up a serial
monitor at 9600 Baud and you should be able to see what is being sent with this code:
output should read somewhere between 0 ~ 1024 on the serial display

Code: [Select]

/*
AnalogReadSerial
Reads an analog input on pin 0, prints the result to the serial monitor.
Attach the center pin of a potentiometer to pin A0, and the outside pins to +5V and ground.

This example code is in the public domain.


*/

// the setup routine runs once when you press reset:


void setup() {
// initialize serial communication at 9600 bits per second:
Serial.begin(9600);
}

// the loop routine runs over and over again forever:


void loop() {
// read the input on analog pin 0:
int sensorValue = analogRead(A0);
// print out the value you read:
Serial.println(sensorValue);
delay(1); // delay in between reads for stability
}

Title: Re: Turbidity sensor coding


Post by: mcarmona on Oct 20, 2016, 07:15 pm

Hi,

I am using one of these sensors for teaching purposes, and I considered that:

https://forum.arduino.cc/index.php?action=printpage;topic=398900.0 1/3
9/18/2018 Print Page - Turbidity sensor coding

1. The output voltage (Vout) of the sensor is inversely proportional to turbidity, so,
2. The clear water have a 0% turbidity, and
3. Turbidity of 100% means a fully opaque object,

So, I proposed the following equation for turbidity (in relative percent units):

Turbidity = 100 - (Vout/Vclear)*100

I also incorporated a push button to calibrate de sensor with clear water, in order to get Vclear (output
voltage for clear water). I also used EEPROM library to store and recover the last calibration Vclear value
in ROM.

Here is the full sketch:

#include <EEPROM.h> // to store last calibration value (blanco, Vclear)


#include <Wire.h> // for LCD display (with I2S interphase)
#include <LiquidCrystal_I2C.h>
LiquidCrystal_I2C lcd(0x3F,2,1,0,4,5,6,7,3, POSITIVE);

int sensor = 0; // variable for averaging


int n = 25; // number of samples to average
int sensorValue = 0;
float voltage = 0.00;
float turbidity = 0.00;
float Vclear = 2.85; // Output voltage to calibrate (with clear water).

int buttoncalib = 2; // The pin location of the push sensor for calibration. Connected to Ground and
// pin D2.

int pushcalib = 1; // variable for pin D2 status.

void setup()
{
Serial.begin(9600);
pinMode(buttoncalib, INPUT_PULLUP); //initializes digital pin 2 as an input with pull-up resistance.

// LCD display
lcd.begin (16,2);
lcd.clear();
lcd.setCursor(0,0);
lcd.print("Turbidity Sensor");

//Serial display
Serial.println("Hi... welcome to your turbidity sensor");

EEPROM.get(0, Vclear); // recovers the last Vclear calibration value stored in ROM.
delay(3000); // Pause for 3 seg
}

void loop()
{
pushcalib = digitalRead(2); // push button status

if (pushcalib == HIGH) {
// If the push button is not pushed, do the normal sensing routine:
for (int i=0; i < n; i++){
sensor += analogRead(A1); // read the input on analog pin 1 (turbidity sensor analog output)
delay(10);
}
sensorValue = sensor / n; // average the n values
voltage = sensorValue * (5.000 / 1023.000); // Convert analog (0-1023) to voltage (0 - 5V)
https://forum.arduino.cc/index.php?action=printpage;topic=398900.0 2/3
9/18/2018 Print Page - Turbidity sensor coding

turbidity = 100.00 - (voltage / Vclear) * 100.00; // as relative percentage; 0% = clear water;

EEPROM.put(0, Vclear); // guarda el voltaje de calibración actualmente en uso.

// Serial display
Serial.print(sensorValue);
Serial.print(", ");
Serial.print(voltage,3);
Serial.print(", ");
Serial.print(turbidity,3);
Serial.print(", ");
Serial.println(Vclear,3);

// Display LCD
lcd.clear();
lcd.setCursor(0,0);
lcd.print("Volts=");
lcd.print(voltage,2);
lcd.setCursor(0,1);
lcd.print("Turbidity=");
lcd.print(turbidity,2);
lcd.print("%");

sensor = 0; // resets for averaging

} else {

// Calibration routine, when push button is pushed:

Serial.println("Put the sensor in clear water to calibrate...");


lcd.clear();
lcd.setCursor(0,0);
lcd.print("Calibrating...");
delay(2000);

for (int i=0; i < n; i++){


sensor += analogRead(A1); // read the input on analog pin 1:
delay(10);
}
sensorValue = sensor / n;
Vclear = sensorValue * (5.000 / 1023.000); // Converts analog (0-1023) to voltage (0-5V):
sensor = 0;
EEPROM.put(0, Vclear); // stores Vclear in ROM
delay(1000);
lcd.clear();
}
delay(1000); // Pause for 1 seconds. // sampling rate
}

SMF 2.1 Beta 1 © 2014, Simple Machines

https://forum.arduino.cc/index.php?action=printpage;topic=398900.0 3/3