Notes:
* Valve position is controlled from PID, there is no direct reference for user for engine load or TC Out exh.
gases with valve position.
At manual mode, actually the position of valve is controlled by user by "try and check" procedure
checking
1) Temp deviation as per sys parameter
2) Target temp based on settings for each load and fuel grade
3) Any alarm triggering
*The selection of MGO/ LFO is controlled automatically by AMS and change over procedure, not by user
on touch screen. On screen is only indication for user reference
*On "PLC Fail" and "valve feed back fail " the valve remain at its previous position when alarm triggered
* On Manual mode V/V position is changed by pressing "Open"/ "Close" touch buttons stepwise +/-1%
or by double click on % symbol on screen and enter the desired xx% by the pop up touch screen keyboard