You are on page 1of 2
Ce ty Cy Cee ee Coe ee ced Bey Ce eid See Cee om proofing PENETRON | www.penetron.com Penetron’s waterproofing effect Is achioved by the reaction ofthe various chemical components contained in the salut when combined within the concrete mattis. The compound penetrates deep into the capillary tracts af the concrete by pressure of osmosis and forms crjstas. that completely seal the capilares and shrinkage cracks to deve out moisture The process works with or against the pressure of wate. In the absence of moisture, Peneton components ie dormant. Should moisture racur at any time, the chemical action anc sealing B process repeats itself automatically and advances even more deeply into the concreta.Panetron chemicals will continuously seal and reseal due to thelr chemical nature. Crystalline ‘rowth from capillary waterproofing has been measur as deep as nearly 11 meter fram the point of application Penetron® is 100% compatible with cconarete, brick, mortar, and stone Penetron is recommended for use in any concrete or block structure where it is required to keap watar in or out, Penetron should also be applied to concrete or block structures exposed to potential watar or chemical attack and thus requiring permanant waterproofing and protection. Its applicability to either the positive side (side exposed to water) or the negative side (side opposite the water) meets all waterproofing requirements. Sholf life Is 12. months when stored ina dry place, unopened undamaged, and in original packaging PENETRON * Booomes an integral prt ofthe concrete, farming a complete body of strength and durabilty. Penetran shoud not be contused with ‘coating or membrane * Penetates deeply and seals concrete's capilary tracts and shvinkage cracks, + Can be applied fom either the postive or negative side 1 Weteproning and cherical-resistance properties remain intact avn ifthe surface is damaged * Completely effctve against high hydrostatic head prassure * More effective overall and less costy than hydrolthic membrane or clay panel ystems + Ease of application, labor-cost effective * Increases concrte's compressive strength + Cannot come apart atthe seams, tear or puncture * Does not require protection during backing, placement of steel or wire mesh, and other common procedures 4 Seals cracks of up to O4mm, Does nat merely mask or bridge hailne and shrinkage oracks * Permits concrete to breathe, eliminating water vapor buldup and leaving the concrete completly dry 4 Resists chemical attack (gH 3-11 constant contact; pH 2-12 periodic contact) and provides a wide range of protection from freeze/thaw cycles, aggressive subsal waters, sea wate, carbonates, chlorides, sufates and nitrates Can be applied to moist or green concrete Protects reinforcing stel Nontoxio Approved for potable water use No extensive curing times (except in very hat or low-humidity conditions) PACKAGING: Dee ec og PENETRON www.penetron.com DIRECTIONS FOR USE: Consumption: Water retaining structures, ‘internal concrete wall surfaces: ‘Two coats of Penetron at 1.25 - 1.5 ib/y! }80 ko/m?) or one coat at 2.5 ~ 3 1.6 kg/m) applied with brush or sry. Construction slabs: Peretion at 2 Ib/y? (1.00 kg/m?) applied in one sury oat to hardened concrete or dry sptnked and trowel applied to fresh coneete when this has reached inital set. Construction joints: Penetron at 3 Indy? (1.5 kg/m?) applied in sur or dy powder consistency imeditly prior to Placing the next itVbay of conereta Blinding concrete: Pension at 25 [bly (1.2 ka/m®) apo in srry or dry powder conssteny immediatly prior to Hlacing the overing conerete sa. SURFACE PREPARATION: All conerete to be veated with Peneton integral crystalline waterproofing must be clean and have an “open” capilery system. Remove laitance, dit grease, atc, by means of high pressure water {atng, wet sandblasting or wie brushing, Faulty conorete in the form of craks. honeyeaihng, et, must be chased aut treated with Petron and fled ush with Penecrete Marta”, Sufaces must be caretly pre-wateed ror to the Penetron application. The conrete surface must be damp but not wet MIXING: Penetron is mechanically mixed with clean water to @ creamy consistency or that resembling thick oll, Appraximate mixing ratio is 2 parts water to 6 parts Penetron powder (oy vlumie). Mix only as much material as can be used within 20 minutes and tr mixture frequent. If the mixture stats to set do net add more water, simply re-stir to restore workabilty, PENETRON Slurry consistency: Apply Penetron in one or two coats avcording to specification by masonry brush or appropriate power soray equipment. When two cuats are speoied apply the second cat while the fist ooat is stl “green” Dry powder consistency: (far novzontal sutace ony). The spectied eraunt of Peneton is distributed in pow frm thraugh a sieve and trowel into the feshly placed concrete once this has reached initial set, Post treatment: The treated areas should be kept damp for 2 period of fve days and must be protected against direct sun, wind and fost, by covering with poeththene sheeting dam burp or smi Note: Do not apply Penetron at temperatures ator blow freezing Penetron cannot be used as an additive 10 concree or plasters. (Penetton Admix should be considered for these applications). APPLICATION: TECHNICAL DATA": Aggregate state: ponder Color: cement grey Bulk density: approx. 65 h/y8 (838 kg/m) “All data are averages of several tests under laboratory conditions. In practice, climatic variations such as temperature, humidity, and porosity of substrate may affect these values HEALTH AND SAFETY: Penetion contains cemet;Irating to eyes and skin, Penetron may cause senstizaion by skin contact. Keep out of reach of children. Avoid contact with skin and eyes. In case of contact with eyes, rinse immadiatay with plenty of water and seek medical advice, Wear sate goes Far ute naman ase rel to Mate Safety Data See. KEEP OUT OF REACH OF CHILDREN, ‘WARRANTY: (CS/Penetron Intemational Ltd. warrants that the produsts manufactured ty it shall be free trom material defeats and wil conform t formulation standards anc contain all components in thet proper proportion. Should any ofthe products be proven defective, the labity to ICS/Penetron Intrationa, Lt. sll be limited to replacement af the material proven to be defective, ICS/Penetron Intemational, Ld. shall inno ase be liable otherwise or for incidental ar consequential damages. ICS/Penetron Intemational, Ld. MAKES NO WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. User shall determina the suitabity of he product for his intended use and assume all risks and lib n connection therewith

You might also like