Y

E D C B A

2750 3600 2700 3350


400 350
350435 600 2590
W2
AR19
1500 875 350 975 975 350 1500 600 900

1200

350
980 350
3 3 Floor Finishing Type

S N Floor Finishing Description

2035
1 F1 16 mm Thick Granite Flooring
900

BABY
2 F2 Porcelain Glazed Tile
COT

3 F3 25 mm Thick Mosaic Flooring


4400

4400
4 F4 Cement Sand Punning
1250

X BABY
X
5

1500
COT F5 Vertified Tile
UP
W1
AR19
1000 350 600

900 300

350 515
320

2 2

UP
1275
4400

4050

4400
1200

1135 1135 RCC COUNTER 800mm HIGH


250
350575

350
1 1
1300

RAMP
1225

UP

Y
UP Ground Floor Plan
350
2400 350 425 900 625 1300 425 1500 425350 1500 1500 350
2750 3600 2700 3350

E D C B A

GROUND FLOOR PLAN


AREA: 145.36 SQ. M.

1:75

01
Y

E D C B A

2750 3600 2700 3350


750 350433 1200 767 350 872 1500 876 350 575 1201 575 350 867 1500 632 350

350 776
Floor Finishing Type

830 350
S N Floor Finishing Description
3 3
1 F1 16 mm Thick Granite Flooring

2 F2 Porcelain Glazed Tile

2034
3 F3 25 mm Thick Mosaic Flooring
1200

4 F4 Cement Sand Punning


4400

4400
5 F5 Vertified Tile

X X

1325
2021

692
750
9200

2 2
350

DN
2099
4400

4400
1200

1135 1135
250
350 751

1 1
1600

1424
1400

First Floor Plan


2400 350 2249 1000 1104 1100 847 999 2001
2750 3600 2700 3350

E Y D C B A

FIRST FLOOR PLAN


AREA: 75.30 SQ. M

1:75

02
Y
E D C B A
12800

985 2750 3600 2700 3350 985


750 2750 10050 750

785

750
Floor Finishing Type
3 3 S N Floor Finishing Description

1 F1 16 mm Thick Granite Flooring

2 F2 Porcelain Glazed Tile

3 F3 25 mm Thick Mosaic Flooring

4800
4 F4 Cement Sand Punning
4400

4400
5 F5 Vertified Tile
X X
9200

2 2
10600

10600
750
4400

4400
4400
1 750 1
1510

1510
1400

1400
Top Floor Plan
10794 1556
2750 3600 2700 3350

12800

E Y D C B A

TOP FLOOR PLAN


SCALE 1:100

1:75

03
E D C B A
+7300 PARAPET LVL.

+6300 TERRACE LVL.


+5900 LINTEL LVL.

+4150 PARAPET LVL.

+3150 FIRST FLOOR LVL.


+2600 LINTEL LVL.

-450 GROUND LVL

FRONT ELEVATION
A B C D E
+7300 PARAPET LVL.

+6300 TERRACE LVL.


+5900 LINTEL LVL.

+3150 FIRST FLOOR LVL.


+2600 LINTEL LVL. Elevation

+1000 SILL LVL.

-450 GROUND LVL

1:75
BACK ELEVATION 04
1 2 3
+7300 PARAPET LVL.

+6300 TERRACE LVL.


+5900 LINTEL LVL.

+4150 PARAPET LVL.

+3150 FIRST FLOOR LVL.


+2600 LINTEL LVL.

+1000 SILL LVL.

-450 GROUND LVL.

SIDE ELEVATION-1
3 2 1
+7300 PARAPET LVL.

+6300 TERRACE LVL.


+5900 LINTEL LVL.

+4150 PARAPET LVL.

+3150 FIRST FLOOR LVL. Elevations

+2600 LINTEL LVL.

+1000 SILL LVL.

-450 GROUND LVL.


1:75

SIDE ELEVATION-2 05
D
A B C E
+7300 PARAPET LVL.

38mm THK C/S


MORTAR+ IPS PUNNING
+6300 TERRACE LVL.
125MM RCC SLAB

+5900 LINTEL LVL.

400

160
750 750
BATTERY
HOUSE

BEDROOM BEDROOM KIT/DINING +4150 PARAPET LVL.

38mm THK C/S


MORTAR+ IPS PUNNIING
750 125MM RCC SLAB
+3150 FIRST FLOOR LVL.
750
400

400
WITH VERTICAL POST @1000mm c/c
CLINIC/ADMIN STORE
ANTE-/POST- NATAL
BEDS
SLUICE

-450 GROUND LVL.

25 mm THICK MOSAIC FLOORING

75MM THK PCC


1 LAYER FLAT BRICK SOILING
100MM SAND FILLING
EARTH COMPACTION
1 2 3
+7300 PARAPET LVL.

38mm THK C/S


MORTAR+ IPS PUNNING
+6300 TERRACE LVL.
125MM RCC SLAB 750

+5900 LINTEL LVL.


400

400
750

+4150 PARAPET LVL.

38mm THK C/S


MORTAR+ TILE
+3150 FIRST FLOOR LVL.
750 125MM RCC SLAB
Sections
400

400

-450 GROUND LVL.

PORCELAIN GLAZED TILE FLOORING

75MM THK PCC


1 LAYER FLAT BRICK SOILING 1:75
100MM SAND FILLING
EARTH COMPACTION
SECTION AT Y-Y 06
OPENING TYPE W W1 W2 W3 W4
1000 1500 1200 900
eq eq eq eq eq eq eq eq

600
1400
1750

1750

1750

1750

800
2750

2750

2750

2750
1000

1000

1000

1000
QUANTITY 2 4 4 1 5
SPECIFICATION ALUMUNIUM SLIDING WINDOW ALUMUNIUM SLIDING WINDOW ALUMUNIUM SLIDING WINDOW ALUMUNIUM SLIDING WINDOW OPENABLE (ALUMUNIUM)
LOCATION GROUND FLOOR GROUND/FIRST FLOOR GROUND/FIRST FLOOR GROUND/FIRST FLOOR GROUND/FIRST FLOOR

OPENING TYPE V1 V2 D1 D2' D2


1500 900
eq eq eq eq 1300
1000 1000

500
600

600

500

500
2750

2750
2600

2600

2600
2250
2150

2150

2100

2100
QUANTITY 2 2 1 1 7
38 mm SAL WOOD FULLY PANELLED 38 mm SAL WOOD FULLY PANELLED
SPECIFICATION ALUMUNIUM SLIDING OPENABLE (ALUMUNIUM) ALUMUNIUM DOOR WITH VIEWING PANE
(75mm x 125 mm frame) (75mm x 125 mm frame)
LOCATION GROUND FLOOR GROUND/FIRST FLOOR ENTRANCE DOOR GROUND FLOOR GROUND FLOOR (SIDE ENTRY) GROUND/FIRST FLOOR

OPENING TYPE D3 D4 DW1 DW2

900 750 1500 1100

DOOR/WINDOW SCHEDULE
500

500

500

500
1600

1600
2600

2600

2600

2600
2100

2100

2100

2100
1000

1000
600 900 350 750
QUANTITY 4 3 1 1
SPECIFICATION ALUMUNIUM DOOR WITH VIEWING PANE ALUMUNIUM DOOR OPENABLE (ALUMUNIUM) OPENABLE (ALUMUNIUM)

LOCATION GROUND FLOOR GROUND/FIRST FLOOR GROUND FLOOR FIRST FLOOR

1:75

07
A B

4600

4300
300 300
X
230 600 1340 600 400 600 230

300

300
1 1

1500
1800

1800
1000
3800
3500

3500
3800
Gents Toilet
1800x3340
Ladies Toilet
600

600
2110x3340

Front Elevation Back Elevation


300 800

300 800
2 2
1000
300
300

70
230 900 830 230 900 1210 230
4300

X
A B

PLAN
PLAN

5800

600 4600 600


Side Elevation Side Elevation
600

900

900
3800
5600

5600

600 1200
350
900

TOILET BLOCK
2750
1200

1200
450

450

5800 G.L.
ROOF PLAN
SECTION AT X-X

1:75

08
Government Of Nepal
National Reconstruction Authority
Central Level Project Implementation Unit(Building)
Babarmahal, Kathmandu

TYPE 4 HP(RCC)

STRUCTURAL DRAWINGS
2020
General Notes For Foundation:

ISOLATE FOOTING DETAILS 1. CONCRETE GRADE M20 & STEEL GRADE FE500
2. ONLY WRITTEN DIMENSIONS TO BE FOLLOWED,
A B C D E DRAWINGS NOT TO BE MEASURED AS PER GIVEN
FOOTING TYPE No. L (mm.) B' (mm.) D (mm.) d (mm.) A B SCALE.
3. ANY DISCREPANCY OR OMISSION IN THIS DRAWING IF
FOUND SHALL BE REPORTED IMMEDIATELY TO SITE
2750 3600 2700 3350 F1 2 2400 2400 450 200 ENGINEER.
4. THE CONTRACTOR SHALL INSPECT & VERIFY ALL
DIMENSIONS & LEVELS IN THE DRAWINGS AND SHALL
F2 1 2200 2200 400 200
F5 F4 F4 F4 F4 COORDINATE WITH ACTUAL SITE CONDITIONS. ANY
DISCREPANCY FOUND SHALL BE BROUGHT TO NOTICE

1500

1800

1800

1800

1800
3 F3 3 200
OF THE ENGINEER IN CHARGE BEFORE EXECUTION OF
2000 2000 400 WORK AT SITE.
1500 5. THIS DRAWING SHALL BE READ IN CONJUCATION WITH
1800 1800 1800 1800
F4 5 200 ALL OTHER STRUCTURAL, ARCHITECTURAL,
1800 1800 400
ELECTRICAL, PLUMBING & WATER SUPPLY DRAWINGS
AND ALL OTHER SERVICES DRAWINGS AND THE
F5 4 1500 1500 350 200 TENDER DOCUMENT.
6. CLEAR COVER FOR FOUNDATION=2"
4400

7. SBC ASSUMED = 100 KN/m2, FOR THE BEARING


CAPACITY LESS THAN THIS VALUE, THE DSIGN OF THE
FOUNDATION SHALL BE REVISED.

F3 F1 F1 F2 F3

2400
2000

2400

2200

2000
2

2000 2200 2000

300
2400 2400

230
@ 150 mm c/c @ 150 mm c/c
4400

.
230 230

F4 F3 F5 F5 F5 LOWER TIE BEAM UPPER TIE BEAM


2000
1800

1500

1500

1500
1

1800 1500 1500 1500


2000

FOUNDATION TRENCH PLAN


GROUND
LEVEL

Upper Tie Beam


GROUND LVL.
Leveling
PLINTH LEV. PCC(1:3:6)
Stone Soiling
with
Y Y Tie beam Compaction
Main Bars
TOE WALL SECTION
GL.

B Lower Tie Beam

Leveling
PCC(1:3:6)

Lower Tie Beam

75mm P.C.C(1:3:6)
150mm Stone Soling

75mm THICK. P.C.C.(1:3:6)


150mm STONE SOLING
TYPICAL COLUMN FOOTING PLAN

TYPICAL COLUMN SECTION AT Y-Y WALL FOOTING SECTION


S-1
TOP FLOOR
A B C D E JOINT TIE

2750 3600 2700 3350 beam

C1 C1 C2 C1 C1

350

350

350

350

350

SPECIAL CONFINING TIES


3
350 350 350 350 350

THE LENGTH h SHALL NOT BE LESS THAN


1. LARGE LATERAL DIMENSION
2. 1/6 OF CLEAR SPAN
4400

3. 450mm

SPECIAL CONFINING TIES


C1 C2 C2 C2 C1
350

350

350

350

350
2
350 350 350 350 350

SPECIAL CONFINING TIES


IS PROVIDED
4400

SPACING OF LATERAL TIE

BUT
SHALL NOT EXCEED 0.5TIMES

LAP
LEAST LATERAL DIMENSION

WHERE
X

SPECIAL CONFINING TIES


C1 C2 C2 C2 C1
350

350

350

350

350
1
350 350 350 350 350

beam
COLUMN LAYOUT PLAN
JOINT TIE z
SAME AS SPECIAL CONFINING TIE

SPECIAL CONFINING TIES


BUT FOR INTERIOR JOINTS
WHERE BEAM WIDTH IS ATLEAST
3/4 OF COLUMN WIDTH
HALF THE SPECIAL CONFINING TIE
BUT NOT GREATER THAN 150mm.
INCASE OF DIFFICULTY IN PROVIDING
CLOSED STIRRUP, U-TYPE MAY BE
PROVIDED.

350 350
L-SECTION OF COLUMN WITH LAPPING TYP. LONGITUDINAL COLUMN SECTION
1st FLOOR

350 350

MAX. SLOPE 1:6

350 350

350 350
Ground Floor

TIE UP BY
BINDING WIRE

TYPICAL BAR DETAIL


AT CORNER COLUMN BAR LAPPING DETAIL X
RECTANGULAR STIRRUPS
BEAM-COLUMN JOINT S-2
LAPPING NOTES FOR BEAM
A B C D E A B C D E
2750 3600 2700 3350 2750 3600 2700 3350 1. LAP LENGTH SHALL NOT BE LESS THAN BAR
DEVELOPMENT LENGTH IN TENSION
2. NOT MORE THAN 50% OF THE BARS SHALL BE
TB 230x230 TB 230x230 TB 230x230 TB 230x230 TB 230x300 TB 230x300 TB 230x300 TB 230x300
SPLICED AT ONE SECTION.
3 3
3. LAP SPLICE SHALL NOT BE PROVIDED:-
a. WITHIN A JOINT
b. WITHIN A DISTANCE OF 2d FROM JOINT FACE
c. WITHIN A QUARTER LINGTH OF THE MEMBER

TB 230x230
4. THE BAR SHALL BE SYMMETRICALLY PLACED ABOUT
TB 230x230 TB 230x300 THE VERTICAL CENTRE LINE OF THE BEAM.
5. WHERE BARS OF DIFFERENT DIA. ARE PLACED IN A SINGLE ROW
TB 230x230 TB 230x300

4400

TB 230x300

TB 230x300

TB 230x300

TB 230x300

TB 230x300

TB 230x300
4400

TB 230x230

TB 230x230

TB 230x230

TB 230x230

TB 230x230
LARGER ARE PLACED ON THE OUTER SIDE.
6. CONCRETE GRADE M20 AND STEEL Fe500.
7. CLEAR COVER FOR BEAM= 25mm.

TB 230x230 TB 230x230 TB 230x230 TB 230x300 TB 230x300 TB 230x300 TB 230x300


2 2
TB 230x230

TB 230x300

TB 230x300

TB 230x300

TB 230x300

TB 230x300
TB 230x230

TB 230x230

TB 230x230

TB 230x230

TB 230x230

4400
4400

TB 230x230 TB 230x230 TB 230x230 TB 230x230 TB 230x300 TB 230x300 TB 230x300 TB 230x300


1 1

LOWER TIE BEAM LAYOUT PLAN AT UPPER TIE BEAM LAYOUT PLAN AT
PLINTH LEVEL 0.00 m PLINTH LEVEL 0.00 m
A B C D E
A B C D E 2750 3600 2700 3350
2750 3600 2700 3350
MB 230x400 MB 230x400 MB 230x400 MB 230x400
3

MB 230x400 MB 230x400 MB 230x400 MB 230x400


3

MB 230x400

MB 230x400

MB 230x400

MB 230x400

MB 230x400
4400
MB 230x400

MB 230x400

MB 230x400

MB 230x400

MB 230x400
4400

MB 230x400 MB 230x400 MB 230x400 MB 230x400


2

MB 230x400 MB 230x400 MB 230x400 MB 230x400


2

MB 230x400

MB 230x400

MB 230x400

MB 230x400

MB 230x400
4400
MB 230x400

MB 230x400
4400

@150MM C/C

MB 230x400 MB 230x400 MB 230x400 MB 230x400


1
400

MB 230x400
1
@200MM C/C

100 230
TERRACE FLOOR
DETAIL AT X FIRST FLOOR BEAM LAYOUT PLAN AT
BEAM LAYOUT PLAN
PLINTH LEVEL 3.15 m
AT PLINTH LEVEL
6.30 m
S-3
LAPPING NOTES FOR BEAM
1. LAP LENGTH SHALL NOT BE LESS THAN BAR
DEVELOPMENT LENGTH IN TENSION
2. NOT MORE THAN 50% OF THE BARS SHALL BE
4400 4400 4400 4400 SPLICED AT ONE SECTION.
3. LAP SPLICE SHALL NOT BE PROVIDED:-
a. WITHIN A JOINT
6 5 6 5 6 6 5 6 b. WITHIN A DISTANCE OF 2d FROM JOINT FACE
c. WITHIN A QUARTER LINGTH OF THE MEMBER
4. THE BAR SHALL BE SYMMETRICALLY PLACED ABOUT
785 6 5 6 6 785 785 785 THE VERTICAL CENTRE LINE OF THE BEAM.
5 6 5 6 5. WHERE BARS OF DIFFERENT DIA. ARE PLACED IN A SINGLE ROW
1100 1100 1100 1100 1100 1100
LARGER ARE PLACED ON THE OUTER SIDE.
6. CONCRETE GRADE M20 AND STEEL Fe500.
7. CLEAR COVER FOR BEAM= 25mm.

1300 1300 1300 1300 1300 1300 1300 1300

3 4 3 4 3 4 3 4

3 4 3 3 4 3
4 1400 1100 1100
4 1100
1400 1100 1100 1100 1100 1100

2 2 2 2

2 2 2 2
1100 1100 1100 1100 1100 1100 1100 1100

1 1 1 1

1 1 1 1
1100 1100 1100 1100 1100 1100 1100 1100

BEAM SECTION ALONG WITH THE GRID A-A,B-B BEAM SECTION ALONG WITH THE GRID C-C,D-D

4400 4400
6 5 6

785 785
6 5 6
1100 1100

1300 1300 1300 1300

3 4 3 4

3 4 3
1400 1100 1100
4 1100
1100

2 2

2 2
1100 1100 1100 1100

1 1

1 1
1100 1100 1100 1100

BEAM SECTION ALONG WITH THE GRID E-E


S-4
LAPPING NOTES FOR BEAM
1. LAP LENGTH SHALL NOT BE LESS THAN BAR
DEVELOPMENT LENGTH IN TENSION
2. NOT MORE THAN 50% OF THE BARS SHALL BE
2750 3600 2700 3350 SPLICED AT ONE SECTION.
3. LAP SPLICE SHALL NOT BE PROVIDED:-
a. WITHIN A JOINT
7 7 7 7 b. WITHIN A DISTANCE OF 2d FROM JOINT FACE
c. WITHIN A QUARTER LINGTH OF THE MEMBER
4. THE BAR SHALL BE SYMMETRICALLY PLACED ABOUT
785 7 7 7 7 785 THE VERTICAL CENTRE LINE OF THE BEAM.
5. WHERE BARS OF DIFFERENT DIA. ARE PLACED IN A SINGLE ROW
800 900 900 830 830 LARGER ARE PLACED ON THE OUTER SIDE.
6. CONCRETE GRADE M20 AND STEEL Fe500.
7. CLEAR COVER FOR BEAM= 25mm.

1100
1100

3' 3' 4' 4' 3'

3' 3' 4' 4' 3'


800 800 900 900 830 830
800 800

GRID BEAM CONNECTION DETAIL


2 2 2 2

2 2 2 2
800 800 900 900 800 800 830 830

1 1 1 1

1 1 1 1
700 700 900 900 675 675 830 830

BEAM SECTION ALONG WITH THE GRID 2-2,3-3 MAIN BEAM, SECONDARY BEAM CONNECTION DETAIL

2750

785 7 785

800

1100 1100

3' 4' 4' 4'

3' 4' 4' 4'


800 800 900 900 800 800 830 830

2 2 2 2

2 2 2 2
800 800 900 900 800 800 830 830

1 1 1 1

1 1 1 1
700 700 900 900 675 675 830 830

BEAM SECTION ALONG WITH THE GRID 1-1


S-5
LAPPING NOTES FOR BEAM
1. LAP LENGTH SHALL NOT BE LESS THAN BAR
DEVELOPMENT LENGTH IN TENSION
2. NOT MORE THAN 50% OF THE BARS SHALL BE
SPLICED AT ONE SECTION.
3. LAP SPLICE SHALL NOT BE PROVIDED:-
a. WITHIN A JOINT
b. WITHIN A DISTANCE OF 2d FROM JOINT FACE
c. WITHIN A QUARTER LINGTH OF THE MEMBER
4. THE BAR SHALL BE SYMMETRICALLY PLACED ABOUT
THE VERTICAL CENTRE LINE OF THE BEAM.
5. WHERE BARS OF DIFFERENT DIA. ARE PLACED IN A SINGLE ROW
slope 1 in 6 LARGER ARE PLACED ON THE OUTER SIDE.
Y 6. CONCRETE GRADE M20 AND STEEL Fe500.
7. CLEAR COVER FOR BEAM= 25mm.

LAPPING DETAIL AT Y
BAR LAPPING DETAIL(BEAM) SCALE:NTS
SCALE:NTS

BEAM

BEAM
COLUMN COLUMN

BEAM & COLUMN JUNCTION DETAIL PLAN BEAM & COLUMN JUNCTION DETAIL PLAN
SCALE: NTS SCALE: NTS

TOP REINF.
MIN.10d

d = Dia of bar BOTTOM REINF.


MAIN BEAM/WALL (MIN.) MAIN BEAM/WALL

TYPICAL ANCHORAGE DETAILS OF SECONDARY BEAM


(REINF. INTO MAIN BEAM / WALL)

ELEVATION
TYP. REINFORCEMENT DETAIL IN BEAMS

S-6
General Notes For Stair:
A B C D E

2750 3600 2700 3350

660

660

660

660
4400

415 825 1080 1080 810 810 1000 500


CANTILEVER SLAB DETAIL

1320

1320

1320
660

1320

1320

1320
540
4400

MIDDLE SLAB DETAIL


1320

1320

660
1

TYPICAL FLOOR SLAB REINFORCEMENT


Slab Thickness 125mm

EDGE SLAB DETAIL

BAR @300 mm C/C BAR @ 300mm C/C


150mm C/C

SLAB SECTION AT X-X

TOP BAR

CHAIR
BOTTOM BAR

TYP. REINF.DET.AROUND CHAIR DETAIL


OPENING IN SLAB
CHAIR DETAIL
S-7
General Notes For Stair:

2750

X Z

UP
4400

SECTION AT Z-Z

Y Y

X Z

TYPICAL STAIRCASE PLAN

SECTION AT X-X

8mm Dia. chair bar @250mm c/c


12mm Dia. Nosing bar

TYPICAL STEP DETAIL SECTION AT Y-Y


S-8