OSN1500 V100R001 Slot Configuration Principles

1.1 OSN1500 Slot Layout

1.1.1 OSN1500 panel

22mm

SLOT14 (Tributary cabling)


SLOT18(PIU)
SLOT15 (Tributary cabling)
SLOT16 (Tributary cabling)
SLOT19(PIU) 221mm
27.2mm SLOT17 (Tributary cabling)
25.4mm

SLOT1 4 * 2 SLOT11 4 * 2 SLOT6 4 * 1

SLOT2 4 * 2 SLOT12 4 * 2 SLOT7 4 * 1


FAN
SLOT2 SLOT3 4 * 2 SLOT13 4 * 2 SLOT8 4 * 1
0
SLOT4 CXLA SLOT9 4 * 1/EOW
mm
SLOT5 CXLB SLOT10 (AUX) 262
444mm

Note: All boards are inserted into the front slots of the equipment. There is no
plugboard area or interface area in the rear of the equipment. The slots are
distributed at two layers: The upper layer, 2U high, is an interface area; while the
lower layer, 2U high, serves to hold processing boards.
The above figure shows the slot distribution. Among them, Slot 11, Slot 12 and slot
13 support slot disassembly. Without disassembly, the slots on the processing board,
from top to bottom, from left to right, are Slot 11, Slot 12, Slot 13, Slot 4  Slot 10
respectively; After Slot 11 is disassembled, the left one is Slot 1 and the right one is
Slot 11.
After Slot 12 is disassembled, the left one is Slot 2 and the right one is Slot 12.
After Slot 13 is disassembled, the left one is Slot 3 and the right one is Slot 13.
In the interface area, the slots distributed from top to bottom, from left to right, are
Slot 14  Slot 19 in turn. Of them, Slot 18 and Slot 19 are PIU boards permanently.
The slot for the fan board is Slot 20, at the left lower corner of the equipment.

1.1.2 Boards Inserted in Fixed Slots

1. The SCC/cross-connect/clock integrated units are fixedly inserted into Slot 4 and
Slot 5. By default, the one in Slot 4 is an active unit.
2. The two PIUs are fixedly inserted into Slot 18 and Slot 19, to provide the subrack
with -48V power hot backup.
3. The EOW board is fixedly inserted into Slot 9.

2004-04-05 Huawei secrets, no dispersion is Page 1 of 3


allowed without permission
OptiX OSN 1500 V100R001 Slot Configuration Principles For internal use only

4. The AUX board is fixedly inserted into Slot 10.

1.1.3 Correlation between the Processing Board and the Interface Board

In an OSN 1500 equipment, Slot 12 on the processing board corresponds to Slot 14


and Slot 15 in the interface area.
Slot 13 on the processing board corresponds to Slot 16 and Slot 17 in the interface
area.
Slot 7 on the processing board corresponds to Slot 15 in the interface area.
Slot 8 on the processing board corresponds to Slot 17 in the interface area.

In the case that Slot 12 and Slot 13 are disassembled into smaller board slots,
Slot 2 corresponds to Slot 14 in the interface area and Slot 12 corresponds to Slot
15.
Slot 3 corresponds to Slot 16 in the interface area and Slot 13 corresponds to Slot
17.

1.1.4 Maximum Access Capacity in Each Slot

The maximum access capacity on each slot of an OSN 1500 system:

Slot 11  Slot 13: 2.5G bus, 4  622M;

Slot 4 and Slot 5: 2.5G bus, 4  622M;

Slot 6  Slot 9: 622M bus, 1  622M;

After Slot 11  Slot 13 are disassembled, the maximum access capacity on each slot
turns to be: Slot 1  Slot 3, 1.25G bus, 2  622M; Slot 11  Slot 13, 1.25G bus, 2 
622M; other slots, unchanged.

1.2 Board Insertion Suggestions


At present, OSN 1500 shares most service boards with OSN 3500 and OSN 2500. A
small card slot has only one kind of service board, 32-E1 SSR1PD1. The basic
principles for board insertion are as follows:
1) In ring network multiplex section protection, insert the line boards east and west
into paired slots and align the boards with each optical interface one to one if
multi-port boards are involved. Refer to the deployment precautions for the
paired slots correlation.
2) Slot 11 is a slot for TPS on E1/T1 boards. To serve the purpose of future
capacity expansion, it is advised to insert E1 tributary boards in Slot 12 and Slot
13.
3) Slot 12 is slot for TPS on E3/DS3/E4/STM-1 boards. To serve the purpose of
future capacity expansion, E3/DS3/E4/STM-1 board is inserted into Slot 13.
4) Slot 6 can serve as a protection board slot for the TPS of PD1 to protect Slot 7
and Slot 8. To serve the purpose of future capacity expansion, it is advised to
insert PD1 in Slot 7 and Slot 8.

2004-04-05 Huawei secrets, no dispersion is Page 2 of 3


allowed without permission
OptiX OSN 1500 V100R001 Slot Configuration Principles For internal use only

Note: As boards in Slots 7 and 12 share the same wire outlet board in slot 15, in case
slot 7 holds a PD1, slot 12 is not allowed to hold PQ1 or PQM, and vice versa.
Likewise, As boards in Slots 8 and 13 share the same wire outlet board in slot 17, in
case slot 8 holds a PD1, slot 13 is not allowed to hold PQ1 or PQM, and vice versa.

Suggestions of board insertion sequence:

SL16 SLQ4: 13 – 12 - 11


SLD4: 13 – 12 - 11

PQ1 PQM: 13 - 12

PD3 PL3: 13 - 12


EFS0: 13 - 12


SEP1: 13 - 12

SL4 SLQ1 SL1: 13 – 12 - 11


EGS2: 13 – 12 - 11


EFS4: 13 – 12 - 11


PD1: 8 – 7 – 3 – 2 – 13 - 12

1.3 Supplementary Information


1) The front panels on all line interface boards have the same panel width;
2) It is not recommended to use the different optical interfaces on the same board
for internetworking;
3) Refer to OSN1500 Electrical Interface Board Protection Features for the
insertion of protection boards and protected boards under TPS protection.