You are on page 1of 3
airmastepe FIRE DAMPER Airmaster Flowtec (P) Ltd .| #25, kanniamman Koil street, Kachina kuppam. | SIDCO Industrial Estate, Ambattur, Chennai - 600 098. | Tel: 044 - 2625 1181 | mail: airmasterchennai@gmail.com | www.airmaster.co.in | FIRE DAMPER Fire dampers are recommended for use in all ducted HVAC ap- plications as per Indian Standards / National Building Codes / NFPA and many other intemational safety codes, Fire dampers shall be installed in the air path wherever central- ized HVAC is in place. ‘These fire dampers are in normally in open condition. Whenever there is a smoke / fire, the damper receives signal from the fire control unit and gets closed, thereby minimizing the spread of smoke /fire to the other nearby areas. AIRMASTE FIRE Dampers are rated upto 120 minutes fire rating as per ULSS5-1995, and approved by Central Building Re- search Institute (CBRI), Roorkee, India CONSTRUCTION: Frame High quality galvanized Iron Sheet of 1.6mm thickness, 150mm wide. Blades High quality galvanized Iron Sheet of 1.6mm thickness, with flat V-type parallel blade operation. ‘Springs 2nos. constant force stainless steel springs Fusible Links: UL listed fusible links which has fire rating of 1650 F / 2120 F. Sleeve : High quality galvanized Iron Sheet of 1.2mm thickness, sleeve length depends on site requirement. Miscellaneous: Chrome plated spindle, seif-lubricating bronze bushes, blade-Linkage fully enclosed, stainless stee! side seal gaskets on the sides(Optional). DESCRIPTION: ‘The frame is made from 1.6mm thk. high quality galvanized iron sheet. All welded joints are rust proofed by zinc paint coat- ing. The blades are 3 V type grove formed from 1.6mm thick galvanized steel. Constant force stainless steel springs are firmly secured to the blades and held in place on the blade linkage. The blades are secured by UL listed fusible links which hhas a fire rating of 1650F / 2120F and thus kept out of the airstream when not in operation. ‘The heat responsive links on detection of heat beyond 1650F / 2120F release the blades from their position. Upon breaks, the blades which are interlinked by linkage connected to the springs, are closes the parallel blades and get automatically locked on a latch and remains so until reset. These fire dampers are rated upto 2 hours rating with low leakage, All dampers are manufactured in compliance to the UL 855 standards and the company's quality control procedures Upon the termination of fire condition, the damper can be re-opened (usually an access door has to be provided for inspec- tion) by simply pulling up the curtain blades and replacing the fusible link. Alrmaster Flowtec(P) Ltd | Tel: 044-2625 1181 | mail: airmasterchennaiegmailcom | wwairmastercoin changes wio notice or obligation a FEATURES: * Robust & rust proof construction * Heavy duty interlocking blades. * Fully enclosed blade linkage mechanism, + Stainless stee! side seal gaskets. + Selflubricating sintered bronze bushes DIMENSIONS AND TYPES: All dampers are made to size as per customer request. ‘The dampers are available with and without extended sleeve of Gl, steel ‘The dampers without extended sleeve are suitable for duct mounting. ‘The dampers with extended sleeve are suitable for wall mounting. MODELS: Model - AFD Fusible link fire damper without sleeve. Model - AFD+M Motorised fire damper without sleeve. Model-AFD+S —: Fusible link fire damper with sleeve. Model - AFD+M+S: Motorised Fire damper with sleeve, PCO il OPTIONS: © Dampers are available with TOF flanges with 30 mm / 40 mm wide flanges. © TDF flanges are available with / without pre-holed cor ners. © Fire dampers are available with sleeve / without sleeve. FUSIBLE LINK FIRE DAMPER: Fusible links which has fire rating of 1650 F / 2120 F, placed in between blades. Blades which are interlinked by linkage with fully loaded stainless springs. Blade linkage is covered by GSS sheet. MOTORISED FIRE DAMPER: Extended shaft is provided for Actuator fixing. Blade Linkage is covered by GSS sheet. Actuator should be fixed in extended shaft. It operated through control panel with temperature sensor. Time- Temperature Curve 2200 08a 00 7500 1000 se 0 67 a ama Seer amasiuene cass ‘The fe damper has been tested by UL Laboratories, USA according to ULSSS standard. The Time / Temperature curve quired by this fie fest procedure is shown above, ‘Altmaster Flowtec(P)Ltd | Tek: 044-2625 1181 | mail: arasterchennal@gmallcom | www.almaster.coin ‘changes wio notice or obligation

You might also like