P-1447 A/B Pulsation Dampener Sizing

Volume per Stroke Calculation


Volume flow rate gl/h 52.8
Formula # 1
Strokes per min min¯¹ 78
V (cubic inch per stroke) inᶾ/stroke 2.6
Pressure Fluctuation
Allowable pressure fluctuation % 5
Formula # 2 Operating Pressure bar 1.44
Minimum pressure (Pmin) bar 1.368
Maximum Pressure (Pmax) bar 1.512
K-Value
Formula # 3 Pump Type Single Acting Simplex
K-Value 0.6
Dampener Size
n (for N₂) 0.714
Formula # 4 n (for Air) 1
Cubic inch required (N₂) inᶾ 47
Cubic inch required (Air) inᶾ 35