You are on page 1of 4
Wuxi Nanfang Explosion-proof Motor Co., Ltd Qianzhou Town, Huishan District, Wari City, Jiangsu Prov PRChina Att: He Daquing, Nemko 08ATEX1012 Enclosed, certificate Nemko 08ATEX1012 with Nemko order no. 105336 based on test reports issued by CQST under order no, 072874. Oslo, 2008-06-26 Dae Vaated Asle Kaastad Nemko: ® é Be. Page lof 3 [1] EC-TYPE EXAMINATION CERTIFICATE 2] Equipment or Protected System Intended for use in Potentially explosive atmospheres Directive 94978 [3] EC-Type Examination Certificate Number: Nemko 08ATEX1012 [4] Equipment or Protective System: Motor [5] Applicant/ Manufacturer: ‘Wuxi Nanfang Explosion-proof Motor Co., Ltd [6] Address: Qianzhou Town, Huishan Wari City, Jangsu Prov PRChina [7] This equipment or protective sytem and any acceptable variation thereto is specified in the schedule to this certificate and the documents therela referred to. [8] | Nemko AS, notified body number 0470 in accordance with Article 9 of Council Directive 94/9/EC of 23 March 1994, certifies that this equipment or protective system has been found to comply with the Essential Health and Safety requirements relating (othe design and construction of equipment and protective systems intended for tse in potentially explosive atmospheres given in Annex It tothe Directive. ‘The examination and test results are recorded in confidential report no. 108336 [9] Compliance withthe Essential Health and Safety Requirements has been assured by compliance with: CENELEC EN 60079-0 2004 CENELEC EN 60079-12008 [10] _1¢¢he sign “X* is placed after the certificate number it indicates thatthe equipment or protective system Is subject fo special conditions fr safe use specified inthe schedule to this cetifieate, mm XAMINATION CERTIFICATE relates only tothe design, examination and tests of the specified equipment or protective system in accordance tothe directive $4/9/EC. Further requirements ofthe Directive apply to the manufacturing proces and supply ofthis equipment or protective system. These are not covered by this cetifiate. [12] ‘The marking of the equipment or protective system shall include the following: & 126 Exd IB T4 Oslo, 2008-05-28 Kolbe Rolf Hoel Certification Manager, Ex-products This cerificate may only be reproduced in its entirety and without any change, schedule included. Postal adres Telephone Enerprise munber: P.Odox 73 Blinder +4772 960330 NO gTAOASI2 NABIA_ OSLO, NORWAY 0373 OSLO, Fa 4722 960850 & Nemko 08ATEX1012 Date: 2008-05-28 Page 2 of 3 [13] Schedule [14] EC-TYPE EXAMINATION CERTIFICATE No Nemko O08ATEX1012 15] Description of Equipment or Protective System This Centficate comprise a series of Nameproof three-phase induction motors Technical Data Al types: 220/380V, 230/400V, 240/415V, 380/660V, 400/690V, 415/720V, 440V SOV6OtKZ Poles: 2, 4, 6, 8 orl0 Insulation class: F ‘Type Designations HB2-63 0.12-0.25kW HB2-71 0.18 -0.55kW HB2-80 0.18 - 11k H1B2-90 037-22kW HB2-100 0.75 - 3kW HB2-112 1.5 -4kW HB2-132 22-75kW HB2-160 4-18.5kW HB2-180 11-22kW HB2-200 15-37kW HB2-225 18.5-45kW HB2-250 30 55kW HB2-280 37-90kW HB2-315 43 - 200kW HIB2-355 90 -31SKW ‘Type designation key example YB2-280M~4-8 r Poles Enclosure features (M, L or $) Central height of shaft Flameproof type Induction motor Ingress Protection Code 13s [16] Report No. 105336 This certificate may only be reproduced in its entirety and without any change, schedule included. Postal adres: fice adres Telephone: Emerprise mumber P.OBox 73 Blindera Gaustadalléen 30 4772960330 NO 974404532 NA314" OSLO, NORWAY 0373 OSLO, Fax 472960850 Nemko 08ATEX1012 Date: 2008-05-28 Page 3 of 3 Descriptive Documents NameNumber Rev. Date__Titls Description Sheets INF.070.200.1-8 - 2007-12. YB2-63 Flameproof Thee Phase Induction Motors And Terminal box small MSA 1 NF.BOI7.10-120 = 2007-12 _-YB2-71 Flameproof Three Phase Induction Motors And terminal box small MSA 1 NF.BOI8.10-160 = 2007-12 __YB2-80 Flameproof Three Phase Induction Motors And terminal box small MSI NF.BO19.10-160 = 2007-12 __YB2-90 Flameproof Three Phase Induction Motors And terminal box small MSL NF.BOIII.10-120 = 2007-12 /__YB2-100 Flameproof Three Phase Induction Motors And terminal box small MSL NFBOII210-80 = 2607-12. YB2-112 Flameproof Taree Phase Induction Motors And terminal box MS Il NF.BOII3.10-180 = 2007-12 __-YB2-132 Flameproof Three Phase Induction Motors And terminal box MS I NF.BOII4.10-120 = 2007-12 _-YB2-160 Flameproof Three Phase Induction Motors And terminal box M6 It NF.BOIIS.10-100 = 2007-12 _-YB2-180 Flameproof Three Phase Induction Motors And terminal box M6 1 NF.BOII6.10-120 = 2007-12 __YB2-200 Flameproof'Three Phase Induction Motors And terminal box M8. I NFBOII7.10-120 = 2007-12. YB2-225 Flameproof Tare Phase Induction Motors And terminal box M8 I INF.070.020.1-8 2007-12. YB2-280 Flameproof Three Phase Induction Motors And terminal box MIO I INF.070.021L.I~16 = 2007-12. YB2-280 Flameproof Three Phase Induction Motors And terminal box MIO I INF.070.026.1~38 - 2007-12. YB2-31$ Flameproof Thre Phase Induction Motors And terminal box M16 IL INF.070.024.1-42 2007-12 YB2-38S Flameproof Thee Phase Induction Motors And terminal box M16 I 8NE.860.201| = 2007-12 Nameplate for Frame 63-132 It 8NF-860.202 = 2007-12 Nameplate for Frame 160-225 I 8NF-860.203 = 2007-12 Nameplate for Frame 250-355 L ONF.460.032 = 2005-10 Operating Insrection manual 9 Routine Test Asstatic pressure test must be performed on every motor and terminal box to ensure thatthe enclosures withstand the pressure and do not contain holes or cracks. Every motor shall withstand a static pressure of I Sbar lasting between 10s and 60s. [17] Special Conditions for Safe Use ‘None [18] Essential Health and Safety Requirements See item 9 This certificate may only be reproduced in its entirety and without any change, schedule included. Postal ores: Office addres Telephone: terprise number P.0.Bex 73 Blinder Gaustadaléen 30 44772 96 03 30 No s74404e32 4314) OSLO, NORWAY 0373 OSLO, Fax 722 960850

You might also like