A330
FLIGHT CREW OPERATING MANUAL
WATER / WASTE
CONTENTS
1.38.00
Pel
SEQ 001
REV 03
38.00 CONTENTS
38.10 DESCRIPTION
— GENERAL
—POTABLE WATER ....
—WASTE WATER SYSTEM . : :
—TOILET SYSTEM.....
38.20 POWER SUPPLY
—BUS EQUIPMENT LIST
RON
3RM _ for training
only —SIM1.1+UP31330 WATER WASTE 1.38.10 Pel
FLIGHT CREW OPERATING MANUAL DESCRIPTION SEQ 001 | REV 04
GENERAL
The water and waste system :
— distributes potable water to the toilets and the galleys.
— disposes waste water.
— stores toilet wastes.
The system is insulated to prevent water leaks and ice build up.
The water and waste control panel is located at the forward cabin attendants panel.
3RM for training only SIMI.1+UP3@ 1330 WATER WASTE 1.38.10 Pee.
sorter DESCRIPTION SEQ 001 | REV 05
FUGHT CREW OPERATING MANUAL
22
POTABLE WATER
Potable water is stored in two (or three <) 350-liters tanks in the side walls of the aft
cargo compartment.
While airborne, the aircraft uses bleed air to pressurize the water system ; on the ground
it uses air from the service panel pressure port.
If no bleed air is available, an electrical compressor (<) starts automatically when air
pressure is not sufficient for normal operation of potable water system.
Potable water is piped to the galleys and lavatories. Manual shut-off-valves isolate the
washbasin and toilet from the water system. These valves, easily identifiable by OPEN and
SHUT legends, are behind an access door under the toilet bow! (on washbasin side). A
placard inside the access door gives instructions on this valve operation.
The system can be filled or drained from the service panel at the bottom of the fuselage.
For filling, the quantity is preselected on the forward attendant’s panel,
Indicators on the forward attendants panel show how much water the water tanks contain.
FW TOILETS
Eo
; FILL/DRAIN:
OvERFLOW VALVE
== wT
DRAINING DRAINING OVER ROND = FILLING/ OVER.
PORT PORT FLOW PRESSURIZATION «DRAINING FLOW
PORT PORT PORT PORT.
GFc5-01-3810-002-A001AA
FWD DRAIN. AFT DRAIN FWD SERVICE
PANEL PANEL
ALL
3RM for training only SIMI.1+UP3A330
FLIGHT CREW OPERATING MANUAL
WATER WASTE 1.38.10 eS
DESCRIPTION SEQ 001 | REV 04
WASTEWATER SYSTEM
Wastewater from the galleys and from the sinks in the lavatories drains overboard through
two anti-iced drain masts.
The forward mast drains wastewater from the forward cabin ; the aft mast drains it from
the aft cabin.
Differential pressure discharges the wastewater in flight, and gravity does so on the
ground.
FWD TOILETS
‘AIR STOP
VALVE
UNDER FLOOR
GF.C5-01-3810-003-A00108
DRAIN MAST
3RM for training only SIMI.1+UP3@ 1330 WATER WASTE 1.38.10 P4
Oe DESCRIPTION SEQ 001 | REV 15
FUGHT CREW OPERATING MANUAL
TOILET SYSTEM
Differential pressure forces waste from toilet bowls into 2 waste storage tanks. On ground,
and at altitudes below 16000 feet, a vacuum generator produces the necessary pressure
differential.
Clear water from the potable water system flushes the toilets.
A flush control unit in each toilet controls the flush sequence.
The Vacuum System Controller (VSC) furnishes operational information {including the
waste level in the storage tank) to the flight attendant’s panel, and maintenance information
and a test program to the centralized maintenance system.
The waste tank has a total capacity of 700 liters (or 1050 liters if 3 tanks).
Ground personnel services the waste tank through a single service panel under the
fuselage.
A manual shut-off valve on the lower right-hand side of the toilet bow isolates an
inoperative toilet.
ARCHITECTURE
an
FORWARD
vaccum = (‘ATTENDANT
PANEL
SYSTEM
CONTROLLER
SYSTEM
}0-004-AO01AA
WATER FLUSH = VACUUM TANK TANK SERVICE
VALVE VALVE GENERATOR | LEVEL PRESSURE PANEL
CONTROL CONTROL CONTROL |SENSORS SENSORS
TOILET
ALL
3RM for training only SIMI.1+UP3ry WATER WASTE 1.38.10 PS
FUGHT GREW OPERATING MANUAL DESCRIPTION SEQ 001 | REV 16
an
LEFT TOILETS
VALVE
t t t
OVERBOARD SERVICE SERVICING
VENT PANEL PORT
GFC5-01-3810-005-A00188
FLUSH VALVE
FLUSH VALVE
RIGHT TOILETS
=
Zz
WATER
RINSE
VALVE
td
WASTE
AIR
3RM for training only SIMI.1+UP3WATER WASTE 1.38.20 Pel
4330
FUGHT CREW OPERATING MANUAL POWER SUPPLY SEQ 001 | REV 15
BUS EQUIPMENT LIST
an)
NORM EMER ELEC
pe {Ac | oc
a pc | ear | ess | ess | MOT
POTABLE WATER SYS. GNDALT
ACT
WATER HEATER or
Ac2
VACUUM GENERATOR L ACT
VACUUM GENERATOR A AC
PRESSURIZED WATER SYS ACL,
FLUSH CONTROL UNITS GND/FLT
VACUUM SYS CONTROLLER GNDALT
3RM for training only SIMI.1+UP3