Compliant and noncompliant


meter box locations ESB

T.V. FH.
GAS

n.300
mi
min. 300

Porch/Balcony/

Building overhang (All Dimensions in millimeters)

TYPICAL METER BOX POSITIONS

Screen Wall option

G
ab
l
e 2
W 5
al I CONFIRM THAT ALL GAS METER BOXES AND GAS
l
3 √ SUPPLY PIPES SHALL BE INSTALLED IN ACCORDANCE

n
8

300m m m i
1 4
x WITH SK/701 AND ITS REQUIREMENTS .

NAME (BLOCK CAPITALS): ..........................


7 6
√ √
POSITION(BLOCK CAPITALS): . . . . . . . . . . . . . . . . . . . . . . . . . .
9√
2m COMPANY(BLOCK CAPITALS): . . . . . . . . . . . . . . . . . . . . . . . . . .
m
ax
Note: SIGNED : ...........................

Meter Box position(s) DATE: ...........................

x
n

Noncompliant - 1, 2, 3, 4, 5
300m m m i

√ Compliant - 6, 7, 8, 9
12 24/3/16 Text Revisions KD AT

Notes: 11 8/3/16 Generally Revised KD AT

� Meter box is not permitted within a porch/building overhang. 10 22/07/15 Meter box detail revised KM AT

ISSUE DATE REVISION DRAWN APPROV.


� A minimum separation of 300mm from the service pipe of the gas meter, to the service pipe of the ESB meter, is required. NETWORK SERVICE CENTRE,

� A minimum separation of 150mm from the gas meter box, to the ESB meter box, is required.
ST MARGARET'S ROAD, FINGLAS
DUBLIN 11.

� A minimum separation of 400mm from the gas meter box, to an electrical distribution board, is required. Tel: (01) 8926000 Fax: (01) 8926001

� A minimum separation of 300mm from the service pipe of the gas meter, to any other services, is required. PROJECT / TITLE

� Meter box shall be greater than 300mm away from a flue. Compliant and noncompliant meter box locations

� Meter box shall not be placed greater than 2 meters from the gable end of the property.
Scale Date Drawn Checked Drawing Number Project Number SHEET
� Meter and service installations shall be in accordance with I.S.813 and I.S.265. 1
NTS 12/03/15 KM KL SK/701 OF