ABSTRACT
Two models using the finite element technique (FE) and another using an
analytical solution to solve the 3-dimensional heat conduction equation for a
jinite plate were built. FE models were built considering the actual pouch shape
and retort temperature profile. Chi-square and regression lines were obtained
for each set of temperatures generated by the models against experimental data.
A mass average sterilizing value of 9.9 min was estimated when a critical point
sterilizing value was at 8.7 min using the 3-Dimensional FE model. Close
agreement was found among the three models for heating phase. Using actual
retort temperature profile made FE models more accurate than the one using
analytical solution, especially for cooling phase.
INTRODUCTION
Thermal processing of foods in cans and bottles has been extensively studied
and mathematical models have been proposed to evaluate and optimize those
processes (Teixeira et al. 1969a, b; Stumbo 1973). However, the market for
ready-to-eat foods packed in retortable pouches has become important in the last
decades, especially in Europe and Japan; and studies to optimize this process
have also become necessary. The increasing interest of the food processor on
retortable pouches relies on its convenience for use, good retention of quality
factors and a potential for reducing energy costs.
' Corresponding author. Prof. Dr.Marcel0 Cristianini, UNICAMP - State University of Campinas.
Faculty of Food Engineering, CP 6121, CEP 13081-970, Campinas-SP, Brazil. TEL: 55-19-
37884008; FAX: 55 19 32893617; E-mail: olecranz@fea.unicamp.br
The Product
Tuna (Kafswonw pelamis) was acquired already preprocessed (clean,
eviscerated, steam cooked for 1 h at 105C and grated) at fish processor located
160 km from the laboratory. The product was kept frozen until needed.
Institutional size pouches (Toyo Seikan Kaisha Ltd.) were filled with 425 g
of tuna and 75 g of brine (2% NaCl w/v) and vacuum sealed to achieve a
maximum of 1 mL residual air. The thermal properties of the product were
estimated using the mathematical models as described by Cristianini (1998) and
showed on Table 1. After each process the water content of the product was
determined in order to calculate the physical properties to be used in the
simulations.
RETORTABLE POUCHES THERMAL PROCESSING 397
TABLE 1.
EXPERIMENTAL MODELS FOR PROPERTIES OF THE PRODUCT
(85% w/w TUNA and 15% BRINE 2% wlv)
PROPERTY MODEL R2
The Models
Three models were built: two of them using finite element technique (2-
dimensional (2DFE) and 3-dimensional 3DFE) through the software package
ANSYS5.2 (Swanson Analysis Systems, Inc.) considering the actual pouch shape
and retort temperature profile. The actual shape of the pouch (190 x 180 x 19
mm) filled with the product was obtained by cutting its two cross-sections and
outlining them on graph paper. The coordinates were used as input data for the
software to generate the finite element grids. In order to avoid excessive
computing time the two models were considered axisymmetric as shown in Fig.
1. The 2-dimensional grid was built using 95 quadrilateral 8-noded elements
398 M. CIUSTIANINI and P. RODRIGUES MASSAGUER
(324 nodes) and the 3-dimensional using 882 tetrahedral 10-noded elements
( 1762 nodes).
The third model was an analytical solution model (ASM). A program using
Pascal programming language was written to predict the temperature profile at
the geometric center of the pouch using the solutions for temperature ratios (U)
under transient conduction for a finite plate with uniform initial temperature as
described by Arpaci (1966):
u = U,.U,.U,
and
a= x, y and z;
Where U, is the dimensionless temperature ratio, a is the distance from the slab
center, d is half thickness of the slab, Fo is the Fourier number, 8, is the nth
positive root of /3 tan /3 = Ei and Ei is the Biot number.
RETORTABLE POUCHES THERMAL PROCESSING 399
Data Acquisition
Nine runs were carried out with the retort completely full. Each run had two
test pouches fitted with a Teflon thermocouple support with three thermocouples
type T 30 gauge (Omega Engineering, Stamford, CT). One thermocouple
junction was held at the pouch geometric center. The other two were set at
0.475 mm and at 0.713 mm from the center (Fig. 2). The thermocouple wires
exited the pouch through a hole in the pouch wall near one of the edges, which
was sealed with silicon glue. Two thermocouples were fitted outside close to the
top and bottom of each pouch test in order to register the temperature of the
surrounding water. The average temperature of those thermocouples was used
as retort temperature profile in the finite element models.
Temperature data acquisition during thermal process was taken every 30 s
using a data logger (Doric 245 A Beckman Ind.) connected to a computer.
Thermal Processing
The car rack was fitted into the retort working tank and it was initially filled
with water at ambient temperature (126C) and the pouches left to equalize
temperature. When difference in center temperature of the pouches was within
0.3C, the water was drained and hot water (121C, 20 PSI air overriding) from
the storage tank was pumped into the working tank. The heating process was
designed to achieve a Fo of 7 min at the end of the heating time, cold water was
allowed to enter the working tank pushing the hot water back to the storage
tank. Cool water was circulated until the product center temperature reached
35C.The process was fully controlled by a specific software (Control View -
Allen Bradley).
element model. For the critical point, the sterilizing value was estimated using
the temperature profile at the node located at the pouch geometrical center. A
procedure analogous to the one described by Teixeira er al. (1969b) was used
to estimate the mass average sterilizing value using the average elements
temperatures generated also by the 3-dimensiod finite element model. The
calculation was carried out as follows: (1) the temperature at each element was
calculated (and considered constant at the 1 min time interval) as the average of
the nodes forming a specific element; (2)this temperature was used to calculate
the thermal death rate (D) over the interval at each element; (3) the concentra-
tion of microorganisms remaining at the end of each time interval was calculated
using the following equation:
pm = Dr l o g p p ) (3)
where Dr is the decimal reduction time at the reference temperature and N and
Noare the total number of microorganisms in the pouch at the end and beginning
of process, respectively. A D = 0, 21 min and z = 1OC were used for
calculations. Reference temperature used was 121.1C.
experimental ones. Using these criteria, the closer the slope of one curve gets
to 1 and the higher the Rz,the better the model would describe the process. A
chi-square test was also used to compare the three models using Eq. (4). as
follows:
Where Oi are the observed temperature values (thermocouples) and Eiare the
estimated by the model.
130 ~ i
110.
,
I
I
1
1
5 10 15 20 25 30 35 40 45 SO
Tima (rnln)
-.--FlniteEkrmsnl2D
k u m i c s l Solullon
Flnb € h e n ( 30 ~ ~ ~ - ‘ ~ % ~ l C 3 l U ~ 1 1
FIG.3. POUCH CENTER TEMPERATURE PROFILES
Table 2 shows chi-square (x’) values, slopes and R2for heating and cooling
phases, as they were analyzed separately. For both, heating and cooling phases,
the R2were higher than 0.9 and slope values close to 1 indicating that all models
were very predictive. The 3-dimensional finite element model had the highest
R2,slope closest to 1 and smaller chi-square value indicating that this model was
the best to describe the process. For the cooling phase, the analytical solution
model (ASM)had a much higher chi-square value. That can be explained due
to the fact that the model consider constaut temperature during cooling phase
which is not true in this type of retort where there is a mix of cooling and
heating medium at the beginning of cooling phase. The finite element models
used actual retort temperature making them more accurate.
402 M. CRISTIA"I aad P. RODRIGUES MASSAGUER
TABLE 2.
CHI-SQUARE e).
REGRESSION SLOPS AND R* OBTAINED FROM THE REGRESSION
LINES OF ESTIMATED AGAINST EXPERIMENTAL TEMPERATURES FOR THE
ANALYTICAL SOLUTION MODEL (ASM) AND FOR THE 2-DIMENSIONAL (2DFE) AND
3-DIMENSIONAL (3DPE) FINITE ELEMENT MODELS
A sterilizing value of 7.9 min was calculated by the general method at the
coldest point using the experimental temperatures at the end of the heating
phase. The values estimated by the models were 7.2, 8.1 and 8.7 min, for the
ASM,2DFE and 3DFE models, respectively. Considering heating and cooling
periods together, the estimated values were 10.2, 9.1, 10.9 and 11.9 min, for
the experimental temperatures and ASM,2DFE and 3DFEmodels. respectively.
The correspondingmass average sterilizing values estimated by the 3DFE model
were 9.9 min and 12.0 min at the end of the heating and cooling phases,
respectively.
Figure 4 shows an accumulation of the average sterilizing value (FA during
the process. Due to its thin profde it was possible to cool the pouch rapidly
avoiding excessive heating. The average sterilizing value was found to be
constant after 4 min of cooling.
Figure 5 shows a histogram of the sterilizing values estimated for each
element at the end of the heating phase. The results show that 50% of the
elements had sterilizing values from 10 to 15 min. On the other hand, there
were some locations within the pouch where the product was more exposed to
high temperatures resulting in sterilizing values as high as 35 min. This kind of
analysis can be helpful for optimization of thermal processes simulatingdifferent
processing conditions in order the achieve the most uniform sterilizing value
distribution possible.
RETORTABLE POUCHES THERMAL PROCESSING 403
CONCLUSION
Close agreement was found between the three models for the heating phase.
Using actual retort temperature profile made the finite element models more
accurate than the third one that used analytical solutions for the heat transfer
equations, especially for cooling phase in this immersion water process where
there is a mixture of cold and hot water at the beginning of cooling phase.
Although 3D and 2D finite element models performed very closely for
predicting temperatures at the pouch center, the 3D model showed to be useful
to predict temperatures at any location within the product and also to predict
microbial destruction (mass average sterilizing value).
The finite element technique has confirmed to be a useful tool to model heat
transfer of irregular shaped products and it was possible to develop a procedure
to analyze the sterilizing value on each element and also an average sterilizing
value for the whole product.
ACKNOWLEDGMENTS
REFERENCES
ARPACI, V.S. 1966. Conduction Heat TraMer. pp. 274, Addison-Wesley Publ.
Co., Reading, MA.
CARVALHO, C.D.F., CRISTIANINI, M. and MASSAGUER, P.R. 1995.
DistribuiGih de Temperatura em Autoclave Rotativa Allpax Usada no
Processamento de Bolsas Esterilidveis: efeito do Tamanho das Embalagens
e do Espqamento entre Bandejas. Anais I Congresso hero-American0 de
Engenharia de Alimentos. Campinas, Brazil.
CASTILLX), P.F., BARREIRO,J.A. and SALAS, G.R. 1980. Prediction of
nutrient retention in thermally processed heat conduction food packaged in
retortable pouches. J. Food Sci. 45, 1513-1528.
CRISTIANINI, M. 1998. Estudo da Disuibuiw de Temperaturas Durante o
Process0 de Esterilh@o de atum (Kutsuwonuspehis)em Bolsa Flexivel.
PhD. Thesis. Universidade Estadual de Campinas, Campinas, Brazil.
CRISTIANINI, M. and MASSAGUER, P.R. 1998. Detenninacao do coeficiente
convectivo de transferencia de calor durante o processamento termico de
atum em bolsas flexiveis autoclavaveis. p. 4, Anais 11Congresso Iberoamer-
icano de Ingeniearia de Alimentos. Bahia Blanca, Argentina.
RETORTABLE POUCHES THERMAL PROCESSING 405