https://doi.org/10.1007/s11356-018-3797-x
RESEARCH ARTICLE
Received: 28 May 2018 / Accepted: 19 November 2018 / Published online: 27 November 2018
# Springer-Verlag GmbH Germany, part of Springer Nature 2018
Abstract
In this study, the long-term operational performance of an on-site NF facility at a full-scale oil-field wastewater desalination plant
was monitored. The NF facility with poor permeability due to membrane fouling enables efficient multivalent salt removal
(rejections of Mg2+, Ca2+, Fe3+, and Al3+ were approximately 100%). Moreover, a comparison of the cleaning efficiencies of two
on-site cleaning modes indicated that PL-007 cleaning helped to improve the effectiveness of subsequent acid cleaning in the
removal of inorganic foulants. Furthermore, a spiral-wound NF membrane module harvested from the plant was unfolded and
autopsied. The results showed that both anionic polyacrylamide (APAM) and crude oil were identified as the predominant
organic matter on the membrane surface and collectively accounted for a substantial fraction (86.3%) in terms of dry weight.
Additionally, dissolved organics with a high molecular weight were prone to accumulation on the membrane surface. Multivalent
elements, including Mg, Ca, Al, Fe, and Si, were the primary inorganic species in the fouling layer. Among the inorganic
elements, Si occupied a high proportion and existed in the form of SiO2 in the fouling layer. According to the autopsy results,
organic fouling combined with inorganics was responsible for the decline in the flux.
Introduction recovery (Li et al. 2017, Riahinezhad et al. 2017), but the
large amount of clean-water consumption and wastewater
The importance of petroleum to modern civilizations is output during this process has raised severe water-shortage
well known. Most of China’s oil fields (such as the concerns. The production of APAM-containing wastewa-
Shengli and Daqing oil fields) have already entered their ter is as high as 5 million tons each year (Liu et al. 2016a).
middle or late periods of production. The application of Due to relatively high water flux and the rejection of dis-
polymer (i.e., anionic polyacrylamide (APAM)) flooding solved solids, organics, and colloidal matter, the
technology in oil fields has effectively improved crude oil nanofiltration (NF) process has been deemed a promising
technology to efficiently reduce mineralization and to re-
move the organic residuals (to meet the quality require-
Responsible editor: Angeles Blanco
ments) in oil-field wastewater (Alzahrani et al. 2013,
Electronic supplementary material The online version of this article Cakmakci et al. 2008, Mondal &Wickramasinghe 2008,
(https://doi.org/10.1007/s11356-018-3797-x) contains supplementary
material, which is available to authorized users.
Zhang et al. 2015). Reusing this wastewater to prepare
the polymer solution is expected to solve the economic
* Dongsheng Zhao and environmental problems caused by clean-water con-
zds123123@yeah.net sumption and wastewater discharge.
As in other membrane-based separation processes (e.g.,
1 ultrafiltration (UF) (Liu et al. 2016b, Wang et al. 2014), elec-
College of Civil Engineering and Architecture, Nanyang Normal
University, Nanyang 473061, China trodialysis (ED) (Guo et al. 2015), and forward osmosis (Han
2 et al. 2015, Phuntsho et al. 2014), fouling is a major issue
School of Civil Engineering and Architecture, University of Jinan,
Jinan 250022, China restricting the efficient operation of NF facilities and can cause
3 the membrane performance to deteriorate, as well as increasing
State Key Laboratory of Pollution Control and Resources Reuse,
School of Environmental Science and Engineering, Tongji the operational costs (Li &Elimelech 2004). Foulants can be
University, Shanghai 200092, China classed into four major categories: inorganic scale, colloidal or
2682 Environ Sci Pollut Res (2019) 26:2681–2690
P
Low Salinity
#1 Water for Reuse
(Permeate)
NF concentrate P
P
#2
NF concentrate P
#3
NF concentrate P
ED Concentrate (Feed)
Legend: Feed Concentrate Permeate
Electromagnetic valve High-pressure pump P Pressure gage Electromagnetic flowmeter
triiodide method (Guo et al. 2015). The chemical structure of Scanning electron microscopy (SEM) energy
the APAM is presented in Fig. S2. The water quality param- dispersive X-ray (EDX) analyses
eters of the feed and permeate are listed in Table 2.
The morphologies and element compositions of the
fouled NF membranes were examined via SEM-EDX
Autopsies of fouled NF membranes analysis (XL30FEG, Philips, Netherlands). For the
cross-section analyses, liquid nitrogen was initially
The acquired membrane module was sawed using a hacksaw employed to fracture the membrane sheets. The mem-
and then unfolded. The membrane sheets were then kept at brane sheets were then sputtered with a thin layer of gold
4 °C in the dark until further analysis. prior to measurement.
Table 2 Water quality of the feed and permeate of the NF facility USA). Measurements were conducted in the range of 4000–
Parameters Feed Permeate 400 cm−1 at a spectrum resolution of 4 cm−1 using 32 scans for
both the background and sample. Accurately weighed
pH 8.67–8.74 7.68–7.84 amounts of the ashed foulants (approximately 100 mg, per-
TDS (mg/L) 5385.8–6767.1 203.9–358.6 formed in triplicate) were subjected to microwave diges-
Na (mg/L) 1276.9–1893.9 55.0–87.2 tion. After digestion, the transparent solution was obtained
Mg (mg/L) 5.6–7.7 – and diluted with ultrapure water. The dilution was then
Ca (mg/L) 13.1–15.6 – analyzed via ICP-OES for its concentrations of inorganic
Fe (mg/L) 0.45–0.83 – elements. The detailed sample preparation procedures are
Al (mg/L) 0.08–0.21 – disclosed in Fig. S3. The crystal types of the foulants were
Si (mg/L) 9.14–9.48 – characterized using XRD (D8 Advance, Bruker, Germany).
Cl− (mg/L) 1024.7–1219.6 61.9–85.0 The chemical compositions of the foulants were analyzed
HCO3− (mg/L) 2745.0–3239.1 82.4–189.1 by X-ray photoelectron spectroscopy (XPS, PHI-5000C
CO32− (mg/L) 252.2–336.0 – ESCA system, Perkin Elmer, USA) using Mg Kα as the
APAM (mg/L) 101.1–117.9 – radiation source (hν = 1253.6 eV).
Crude oil (mg/L) 0.53–0.64 0.25–0.31
The ranges are shown for seven randomly collected water samples Results and discussion
Foulants were collected from a measured surface area (ap- The water quality parameters of the feed and permeate from
proximately 400 cm2, performed in triplicate) of the fouled the NF facility are presented in Table 1. The ranges are shown
membrane sheets by physical scrapping. Dry foulants were in Table 1 for seven randomly selected water samples during
obtained through freeze-drying. The recovered foulants were long-term operation. Compared with that of the feed, the pH
weighed, and the mass per unit surface area of the fouled value of the permeate decreased. Normally, the NF membrane
membrane was calculated. rejected multivalent cations (such as Mg2+, Ca2+, Fe3+, and
Al3+) with a high efficiency (see Table 2), which caused an
Loss on ignition (LOI) test Accurately weighed quantities (ap- increase of protons in the permeate base on the electrical equi-
proximately 1000 mg, performed in triplicate) of the lyophi- librium (Luo &Wan 2013, Mazzoni et al. 2007). Then, the pH
lized foulants were subjected to ignition at 550 °C in a muffle of the permeate decreased. The TDS in the permeate was
furnace for 6 h. The LOI percentage was then calculated below 1000 mg/L, meeting the standard for reinjection water
(Khan et al. 2014, Khan et al. 2013). quality (Zhang et al. 2015). The rejection rates of the NF
membrane for monovalent ions (e.g., Na+, K+) were above
Organic foulant extraction (Wang and Tang 2011) and analysis 90%, whereas the rejection rates of the NF membrane for
Membrane samples (200 cm2, performed in triplicate) were multivalent cations (such as Mg2+, Ca2+, Fe3+, and Al3+) were
used for foulant extraction. A 400-mL mixed solution contain- close to 100%. APAM was not detected in the permeate, in-
ing 10 mM ethylenediaminetetraacetic acid (EDTA) and dicating that the macromolecular APAM could not easily pass
2.5 mM sodium dodecyl sulfonate at pH = 12.0 was used for through the NF membrane pores that were smaller than 1 nm
foulant extraction. Mild sonication (30 min) was employed (Kumar &Pal 2014, Mo et al. 2012). The content of crude oil
after 24 h soaking of the samples in the extraction solution. in the permeate was in the range of 0.25 to 0.31 mg/L, sug-
Thereafter, the contents of the crude oil and APAM in the gesting that alkanes with low molecular weight (Esquinas
foulants were quantified by the methods described in the et al. 2017) passed through the NF membrane pores.
BWater quality characterization^ section. The long-term flux variations at the NF facility are
shown in Fig. 2a. From 0 to 480 days, the average flux at
Analytical methods the NF facility decreased from 4.0 to approximately 3.0 L/
(m2 h MPa), indicating that chemically irreversible fouling
The molecular weight (MW) distributions of the organics in of the NF membranes gradually enhanced. As shown in
the feed and foulants were measured by high-performance size Fig. 2b, the long-term rejection performance of the NF
exclusion chromatography (LC-10CE, Shimadzu, Japan). facility was fairly stable. The permeate conductivity of
Fourier transform infrared (FTIR) spectra of the lyophilized the NF facility was in the range of 200–700 μS/cm, which
foulants were obtained with a potassium bromide pellet using satisfied the standard for reinjection water quality (Zhang
an FTIR spectrometer (Nicolet 5700, Thermo Scientific, et al. 2015).
Environ Sci Pollut Res (2019) 26:2681–2690 2685
5 1500
(a) (b)
Permeate conductivity
3 900
2
2 600
1 Flux 300
0 0
0 60 120 180 240 300 360 420 480 0 60 120 180 240 300 360 420 480
Time (d) Time (d)
Fig. 2 Long-term operational performance of the NF facility: variations in flux (a) and permeate (b) conductivity. The data shown in the figure are the
average values for the total NF facility (including #1, #2, and #3 in Fig. 1)
Efficiency comparison of the two cleaning modes PL-007) contained sodium hydroxide and an anionic surfac-
tant. Therefore, the alkaline environment could deprotonate
Chemical cleaning is mandatory at the NF facility due to the foulants (i.e., APAM) on the membrane surface and cause
membrane fouling. Figure 3 shows the variations in the per- the fouling layer to become loose. Moreover, the anionic sur-
meate flux of the NF facility after being cleaned by two factant in the agent has a strong removal capacity for crude oil
cleaning modes. The acid/PL-007@PL-007/acid and PL- (Fletcher et al. 2015, Wang et al. 2014) on the membrane
007/acid@acid/PL-007 cleaning procedures were conducted surface, which favors the exposure of inorganic foulants en-
for facility #1 and facility #2 in Fig. 1, respectively, and the capsulated by organics. Subsequent acid cleaning can improve
results are shown in Fig. 3a and b, respectively. As shown in the removal of such foulants.
Fig. 3a, the flux of facility #1 had no significant change and Before ICP-OES analysis, the cleaning solutions from the
was still maintained at approximately 3.3 L/(m2 h MPa) after two cleaning modes were subjected to microwave digestion.
acid/PL-007 cleaning, while after PL-007/acid cleaning, the The ICP-OES analysis results are shown in Table 3. For the
flux of facility #1 obviously increased from 2.5 to 3.2 L/ two cleaning modes, the contents of the inorganic elements in
(m2 h MPa). Similarly, as displayed in Fig. 3b, the flux of the acid solutions were higher than those in the PL-007 solu-
facility #2 significantly increased from 3.0 to 3.8 L/ tions, while the concentrations of organics (i.e., crude oil and
(m2 h MPa) after PL-007/acid cleaning, while after acid/PL- APAM) in the PL-007 solutions were significantly higher than
007 cleaning, the flux of facility #2 only increased from 3.1 to those in the acid solutions. These results indicated that the acid
3.3 L/(m2 h MPa). These results indicated that the cleaning cleaning agent was more effective for the removal of inorganic
efficiency of the PL-007/acid procedure was higher than that foulants, while PL-007 was more effective for the removal of
of the acid/PL-007 procedure. The reason for these differences organic foulants. Additionally, the contents of inorganic ele-
in efficiency may be that the commercial cleaning agent (i.e., ments (Mg, Ca, Fe, Al, and Si) in the acid cleaning solution
5 5
(a) #1 (b) #2
PL-007/acid Acid/PL-007
4 Acid/PL-007 4
Flux [L/(m h MPa)]
PL-007/acid
Flux [L/(m h MPa)]
3 3
2
2
2 2
1 1
0 0
-20 0 20 40 60 80 100 120 140 160 180 -20 0 20 40 60 80 100 120 140 160 180
Time (h) Time (h)
Fig. 3 Efficiency comparisons of two cleaning modes: Acid/PL-007@PL-007/acid cleaning for facility #1 (a) and PL-007/acid@acid/PL-007 cleaning
for facility #2 (b) in Fig. 1
2686 Environ Sci Pollut Res (2019) 26:2681–2690
Table 3 Component analysis in the cleaning solutions for the two cleaning modes
The units for the contents in the table are all mg/L
(Guo et al. 2015). The absorption peaks at 2924, 2854, 1459, Compared to the other elements, Si occupied a relatively high
1379, and 720 cm−1 are related to the bonds in aliphatic hy- level (39.62 mg/g) in the fouling layer, which was consistent
drocarbons CH3–(CH2)n–CH3 (where n is 3 or greater), indi- with the EDX results. Although the contents of Al and Fe were
cating the existence of crude oil in the fouling layer (Meléndez relatively low in the feed (in the range of 0.08–0.21 mg/L and
et al. 2012). The prominent peak at 1042 cm−1 can be assigned 0.45–0.83 mg/L, respectively), they accounted for higher pro-
to the stretching vibration of Si–O bonds (Gorzalski portions in the inorganic fraction than the divalent elements
&Coronell 2014, Tang et al. 2014), suggesting the occurrence (i.e., Ca and Mg) did, which could be attributed to their stron-
of silica fouling. ger coordinating abilities with the carboxylate groups of the
Unlike the EDX spectrum analysis, the ICP-OES analysis membrane surface and the APAM molecules relative to those
can provide the average contents of inorganic elements in the of divalent ions (Mo et al. 2012), (Rivas et al. 2011). These
fouling layer. The inorganic element contents from ICP-OES results suggested that the removal of multivalent elements,
analysis are exhibited in Fig. 7b. The inorganic components of particularly Al, Fe, and Si, is the key to controlling NF mem-
the foulants mainly consisted of Na, Mg, Ca, Fe, Al, and Si. brane fouling.
2688 Environ Sci Pollut Res (2019) 26:2681–2690
60
elimination of Al, Fe, and Si from the feed of the NF
492.7
13.7
20
200 ular, the meaningful findings in this study are as follows:
the differences of the molecular weight of organics in the
0 0 feed and on the membrane surface (see Fig. 6), the main
l nic nic il
ta
ga eo PA
M nic nic organic components (APAM and crude oil) in the foulants,
To Or rga ud ga rga
Ino C r A Or I n o
and the co-existence of APAM and inorganic elements
Fig. 5 Fouling load of fouled NF membranes (such as Na, Mg, Ca, Fe, Al) and SiO2 in the fouling layer.
Environ Sci Pollut Res (2019) 26:2681–2690 2689
3250
3400
(a) (b)
foulants: FTIR spectrum (a), ICP-
2924
OES analysis (b), XRD spectra Si
2854
40
(c), and XPS Si2p3 narrow spec-
1409
1379
30
720
20
Na
Al
10
-OH -N-H Fe
Mg Ca
0
4000 3500 3000 2500 2000 1500 1000 500 0.1 1 10 100 1000
-1
Wavenumber (cm ) Concentration in the NF feed (mg/L)
Future efforts should focus on the NF membrane fouling be- long-term operation due to membrane fouling. The effi-
havior caused by APAM with different molecular weights, the ciency of PL-007/acid cleaning was better than that of
combined organic fouling characteristics of the NF membrane acid/PL-007 cleaning based on the flux recovery. The au-
caused by APAM and crude oil, and the influence of the inter- topsy results showed that the organic foulants on the fouled
action between APAM and metal ions or colloid SiO2 on the NF membrane surface were mainly composed of APAM
fouling behavior of the NF membrane. and crude oil and accounted for 86.3% of the total foulants
in terms of dry weight. The organics with high molecular
weight were more prone to accumulation on the membrane
Conclusions surface than those with low molecular weight. In the foul-
ing layer, the inorganic elements mainly included Mg, Ca,
The long-term performance monitoring of an NF facility Fe, Al, and Si, with Si existing in the form of SiO 2 .
and comprehensive analysis of the fouled NF membranes According to the autopsy results, organic fouling com-
at an oil-field wastewater desalination plant were conduct- bined with inorganics was responsible for the flux decline
ed. The flux of the NF facility decreased gradually during in the NF membranes.
Funding information This research was financially supported by the Liu G, Yu S, Yang H, Hu J, Zhang Y, He B, Li L, Liu Z (2016a) Molecular
Natural Science Foundation of Shandong Province (ZR2018BEE040) mechanisms of ultrafiltration membrane fouling in polymer-
and the Scientific Research Project of Nanyang Normal University flooding wastewater treatment: role of ions in polymeric fouling.
(2018ZX022). Environ Sci Technol 50:1393–1402
Liu G, Yu S, Yang H, Hu J, Zhang Y, He B, Li L, Liu Z (2016b)
Molecular mechanisms of ultrafiltration membrane fouling in
References polymer-flooding wastewater treatment: role of ions in polymeric
fouling. Environ Sci Technol 50:1393–1402
Luo J, Wan Y (2013) Effects of pH and salt on nanofiltration-a critical
Alzahrani S, Mohammad AW, Hilal N, Abdullah P, Jaafar O (2013)
review. J Membr Sci 438:18–28
Identification of foulants, fouling mechanisms and cleaning efficien-
cy for NF and RO treatment of produced water. Sep Purif Technol Mazzoni C, Bruni L, Bandini S (2007) Nanofiltration: role of the electro-
118:324–341 lyte and pH on desal DK performances. Ind Eng Chem Res 46:
Antony A, Low JH, Gray S, Childress AE, Le-Clech P, Leslie G (2011) 2254–2262
Scale formation and control in high pressure membrane water treat- Meléndez LV, Lache A, Orrego-Ruiz JA, Pachón Z, Mejía-Ospino E
ment systems: a review. J Membr Sci 383:1–16 (2012) Prediction of the SARA analysis of Colombian crude oils
Asatekin A, Mayes AM (2009) Oil industry wastewater treatment with using ATR–FTIR spectroscopy and chemometric methods. J Pet Sci
fouling resistant membranes containing amphiphilic comb copoly- Eng 90–91:56–60
mers. Environ Sci Technol 43:4487–4492 Mo YH, Tiraferri A, Yip NY, Adout A, Huang X, Elimelech M (2012)
Cakmakci M, Kayaalp N, Koyuncu I (2008) Desalination of produced Improved antifouling properties of polyamide nanofiltration mem-
water from oil production fields by membrane processes. branes by reducing the density of surface carboxyl groups. Environ
Desalination 222:176–186 Sci Technol 46:13253–13261
Esquinas N, Rodriguez-Valdes E, Marquez G, Gallego JLR (2017) Mondal S, Wickramasinghe SR (2008) Produced water treatment by
Diagnostic ratios for the rapid evaluation of natural attenuation of nanofiltration and reverse osmosis membranes. J Membr Sci 322:
heavy fuel oil pollution along shores. Chemosphere 184:1089–1098 162–170
Fletcher PD, Savory LD, Woods F, Clarke A, Howe AM (2015) Model Ochando-Pulido JM, Rodriguez-Vives S, Hodaifa G, Martinez-Ferez A
study of enhanced oil recovery by flooding with aqueous surfactant (2012) Impacts of operating conditions on reverse osmosis perfor-
solution and comparison with theory. Langmuir 31:3076–3085 mance of pretreated olive mill wastewater. Water Res 46:4621–4632
Gorzalski AS, Coronell O (2014) Fouling of nanofiltration membranes in Ohno K, Matsui Y, Itoh M, Oguchi Y, Kondo T, Konno Y, Matsushita T,
full- and bench-scale systems treating groundwater containing silica. Magara Y (2010) NF membrane fouling by aluminum and iron
J Membr Sci 468:349–359 coagulant residuals after coagulation-MF pretreatment.
Guo H, You F, Yu S, Li L, Zhao D (2015) Mechanisms of chemical cleaning Desalination 254:17–22
of ion exchange membranes: a case study of plant-scale electrodialysis Phuntsho S, Lotfi F, Hong S, Shaffer DL, Elimelech M, Shon HK (2014)
for oily wastewater treatment. J Membr Sci 496:310–317 Membrane scaling and flux decline during fertiliser-drawn forward
Gur-Reznik S, Katz I, Dosoretz CG (2008) Removal of dissolved organic osmosis desalination of brackish groundwater. Water Res 57:172–182
matter by granular-activated carbon adsorption as a pretreatment to Riahinezhad M, Romero-Zeron L, McManus N, Penlidis A (2017)
reverse osmosis of membrane bioreactor effluents. Water Res 42: Evaluating the performance of tailor-made water-soluble copoly-
1595–1605 mers for enhanced oil recovery polymer flooding applications.
Han G, de Wit JS, Chung T-S (2015) Water reclamation from emulsified Fuel 203:269–278
oily wastewater via effective forward osmosis hollow fiber mem- Rivas BL, Pereira ED, Palencia M, Sanchez J (2011) Water-soluble func-
branes under the PRO mode. Water Res 81:54–63 tional polymers in conjunction with membranes to remove pollutant
Kang GD, Cao YM (2012) Development of antifouling reverse osmosis ions from aqueous solutions. Prog Polym Sci 36:294–322
membranes for water treatment: a review. Water Res 46:584–600 Tang F, Hu H-Y, Sun L-J, Wu Q-Y, Jiang Y-M, Guan Y-T, Huang J-J
Khan MT, Manes CLD, Aubry C, Croue JP (2013) Source water quality (2014) Fouling of reverse osmosis membrane for municipal waste-
shaping different fouling scenarios in a full-scale desalination plant water reclamation: autopsy results from a full-scale plant.
at the Red Sea. Water Res 47:558–568 Desalination 349:73–79
Khan MT, Busch M, Molina VG, Emwas AH, Aubry C, Croue JP (2014) Wang Y-N, Tang CY (2011) Nanofiltration membrane fouling by oppo-
How different is the composition of the fouling layer of wastewater sitely charged macromolecules: investigation on flux behavior,
reuse and seawater desalination RO membranes? Water Res 59: foulant mass deposition, and solute rejection. Environ Sci Technol
271–282 45:8941–8947
Kumar R, Pal P (2014) Membrane-integrated hybrid system for the ef- Wang Z, Ma J, Tang CY, Kimura K, Wang Q, Han X (2014) Membrane
fective treatment of ammoniacal wastewater of coke-making plant: a cleaning in membrane bioreactors: a review. J Membr Sci 468:276–307
volume reduction approach. Environ Technol 35:2018–2027 Zhang R, Shi W, Yu S, Wang W, Zhang Z, Zhang B, Li L, Bao X (2015)
Lai CH, Chen YH, Yeh HH (2013) Effects of feed water quality and Influence of salts, anion polyacrylamide and crude oil on
pretreatment on NF membrane fouling control. Sep Sci Technol nanofiltration membrane fouling during desalination process of
48:1609–1615 polymer flooding produced water. Desalination 373:27–37
Li QL, Elimelech M (2004) Organic fouling and chemical cleaning of Zhao L, Ho WSW (2014) Novel reverse osmosis membranes incorporat-
nanofiltration membranes: measurements and mechanisms. Environ ed with a hydrophilic additive for seawater desalination. J Membr
Sci Technol 38:4683–4693 Sci 455:44–54
Li Q, Song J, Yu H, Li Z, Pan X, Yang B (2014) Investigating the micro- Zhao HY, Qiu S, Wu LG, Zhang L, Chen HL, Gao CJ (2014) Improving
structures and surface features of seawater RO membranes and the the performance of polyamide reverse osmosis membrane by incor-
dependencies of fouling resistance performances. Desalination 352: poration of modified multi-walled carbon nanotubes. J Membr Sci
109–117 450:249–256
Li M, Romero-Zeron L, Marica F, Balcom BJ (2017) Polymer flooding Zhou L, Xia S, Alvarez-Cohen L (2015) Structure and distribution of
enhanced oil recovery evaluated with magnetic resonance imaging inorganic components in the cake layer of a membrane bioreactor
and relaxation time measurements. Energy Fuel 31:4904–4914 treating municipal wastewater. Bioresour Technol 196:586–591