You are on page 1of 59

SPECIFICATIONS

Fixed Displacement
Checkball Piston Pumps
Also refer to "Checkball Pump Installation and Operating
Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf)

CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: sales@dynexhydraulics.com

Power Units & Systems


Dynex/Rivett Inc.
54 Nickerson Road
Ashland, MA 01721 U.S.A.
Tel: 508-881-5110
FAX: 508-881-6849
E-mail: ashland@dynexhydraulics.com

European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: sales@dynexhydraulics.co.uk

Download Dynex Product Specifications!

BROCHURE NOTES:
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative or the sales department for the most current specifications before ordering.
Dynex reserves the right to discontinue products or change designs at any time without incurring any
obligation.

DYNEX High Pressure Hydraulics

Copyright © Dynex/Rivett Inc. Bulletin dynexpespfspecs-1204


CHECKBALL PISTON PUMPS

USING THIS BROCHURE Table of Contents


This brochure contains specifications for Pump Type and Series Page
the most commonly used checkball pumps. Fixed Displacement Pumps 2
Contact the sales department for availability
of models with features and operating PF500 Series (S.A.E. A-A 2-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
requirements not shown here. PF1000 Series (S.A.E. A 2-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Refer to page 28 for general fluid guidelines PF2000 Series (S.A.E. B 2-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
and information on ports. Request Bulletin
PSI.CB (dynexpumprecommendations.pdf) PF2000 Series (Special Mounting) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
for checkball pump installation and PF3000 Series (S.A.E. C 4-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
operating recommendations.
PF4000 Series (S.A.E. D 4-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PF4200 Series (S.A.E. D 4-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PF4300 Series (S.A.E. D 4-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PF6000 Series (S.A.E. E 4-bolt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Fluid Guidelines and Outlet Port Configurations . . . . . . . . . . . . . . . . . . . . . . . . 28

HOW THE PUMPS OPERATE ROTATING


INLET INLET CHECKBALL
WOBBLE PLATE OUTLET 1
The checkball pump design uses
two check valves in each piston
pumping chamber to direct flow
from the inlet side of the pump to
the pump outlet port.
DRIVE
SHAFT
Wobble Plate Rotates with Shaft SUCTION

During operation, a fixed angle OUTLET


wobble plate rotates with the CHECKBALL
drive shaft. The angled surface
of the wobble plate imparts a
reciprocating motion to the pistons DISCHARGE

which move in and out of the bores SPLIT-FLOW


COVER
in the stationary barrel. DESIGN
During its suction stroke, each
piston is filled through its inlet
check valve. Fluid is drawn by
vacuum into the piston pumping
chamber in the barrel. STATIONARY PISTON BARREL OUTLET 2

Check Valves Control Fluid


During compression, the inlet check across the check valve, out of the Multiple Outlet Pumps
valve closes and pressure in the pumping chamber. Piston outputs In Split-Flow ® models, the piston
pumping chamber rises until it exceeds are combined in the pump barrel outputs can be isolated, or grouped
load pressure at the outlet port. or cover, and then discharged from together in various combinations,
The outlet checkball then lifts the pump outlet providing smooth supplying flows to multiple function
off its seat and fluid is pumped flow to the system. circuits without flow dividers.

2
PF3000PF500
SERIES,
SERIES
10 DESIGN

Specifications
Output Flow Output Flow Maximum
at 1500 rpm at 1800 rpm Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm➂
PF501-11 0.17 0,66 0.21 0,79 8000 560 8000 560 1800 3600
PF504-11 0.28 1,04 0.34 1,28 8000 560 8000 560 1800 3600
PF507-11 0.38 1,45 0.46 1,76 8000 560 8000 560 1800 3600
PF510-11 0.57 2,16 0.69 2,59 8000 560 8000 560 1800 3600
PF501H-11 0.17 0,64 0.20 0,75 10 000 700 15 000 1040 1800 3600
PF504H-11 0.27 1,02 0.32 1,22 10 000 700 15 000 1040 1800 3600
PF507H-11 0.37 1,40 0.45 1,70 10 000 700 15 000 1040 1800 3600
PUMP DESCRIPTION PF510H-11 0.56 2,12 0.67 2,52 10 000 700 15 000 1040 1800 3600
 Output flow based on typical performance at rated pressure with pressurized inlet where required, as
Fixed displacement checkball pumps, with shown in the table below.
bi-directional shaft rotation, provide  Contact the sales department for applications requiring continuous duty operation at speeds higher than
1800 rpm or lower than 900 rpm. See “Typical Performance Curves” on page 4.
constant direction of output flow regardless ➂ Higher than rated speeds may require a pressurized inlet. Refer to “Inlet Conditions”.
of the direction of drive shaft rotation.
Typical Applications Minimum Inlet Pressure 
Reduced power requirements, as low as
Operating Speed
1.0 HP at 10 000 psi (0.7 kW at 700 bar),
make these pumps ideal for use in remote 1800 rpm 2800 rpm 3600 rpm
Pump
locations with limited power supply. Models psi bar psi bar psi bar
These compact high-pressure pumps can PF501 and PF504 0 0 0 0 5 0,4
be used on portable power packs for high- PF507 0 0 5 0,4 10 0,7
pressure torque wrenches and other service PF510 0 0 10 0,7 15 ➐ 1,0 
tools. Split-Flow® models with multiple  Values shown are based on fluid viscosity of 100 SUS (20 cSt).
outlets are ideal for tool circuits with  Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. Refer to "Typical Model
Code" on page 6 for seal options.
changing flow and pressure requirements.
Mounting
S.A.E. A-A 2-bolt pattern with 0.25 inch use with some phosphate ester fluids, or Fluid Guidelines
(6,4 mm) pilot engagement. Fluorocarbon with high pressure shaft seal. See page 28 for “Fluid Recommendations”.
Shaft Weight (Mass) Some pump models may require reduced
Available with 0.625 inch (15,88 mm) 11.9 lb (5,4 kg) operating pressures when using low-
diameter keyed shaft. lubricity fluids.
PUMP SELECTION Because of the wide range of fluid
Outlet Port Options characteristics, contact the sales
Standard pressure models have S.A.E. ports. The table shows specifications for standard department for a review of any application
The high pressure “H” option requires the pressure models and “H” option models for using non-petroleum based fluids.
use of outlet port option “A” (Autoclave use at intermittent pressures higher than
Medium Pressure, Butech M/P or equivalent 8000 psi (560 bar). Split-Flow® Provides Multiple Outlets
fittings), or outlet port option “B” (British Ordering a PF500 Series pump requires a PF500 models with split-flow covers
Standard Pipe fittings). complete model code specifying shaft, seal efficiently supply flows for multiple function
and outlet port options. Refer to “Typical circuits. Piston outputs are grouped together
Inlet Conditions in the cover, with various piston flow splits
Model Code” on page 5.
Pumps may require pressurized inlet available in this four-piston pump. Refer to
conditions at higher speeds. Failure to meet Maximum Pressure “Typical Model Code” on page 5 and contact
minimum inlet requirements will result in a The intermittent pressures listed in the the sales department for availability.
slight flow reduction. Refer to the table. table are the maximum pressures a pump
can sustain for occasional, short periods of
Reduced Output Option
Seal Options Pump output can be reduced by one-half by
operation without appreciably reducing life
Standard seals are Fluorocarbon (Viton® expectancy. deactivating two pistons. Refer to “Typical
or Fluorel®). Options include EPR seals for Model Code” on page 5.
4
PF500 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet where required.
Refer to the “Minimum Inlet Pressure” table on page 3. Contact the sales department for applications
requiring continuous duty operation at speeds higher or lower than shown.

INSTALLATION
All dimensions are shown in inches The drawing shows dimensions common to Configurations” on page 29 and “Typical
(milli­meters in parentheses) and are all PF500 models. Note that the location of Model Code” on page 5 to specify port.
nominal. Refer to Bulletin PSI.CB for general the outlet port varies as shown, dependent
installation and operating recommendations. on the type of port. Refer to “Outlet Port

5.20 CONED AND


(132,1) THREADED PORT
5.30 S.A.E. OR OUTLET PORT — NO. 6 S.A. E.;
(134,6) B.S.P. PORT OR 3/8 MEDIUM PRESSURE CONED AND
THREADED, .5625-18 U.N.F.–2B THREADED
1.625 1.625 INLET PORT (AUTOCLAVE, BUTECH M/P OR EQUIVALENT);
(41,28) (41,28) 2.88 NO. 12 S.A.E. OR G 1/4 (B.S.P.)
(73,20)
SQUARE KEY
.1875 x .75 (4,763 x 19,1)
1.94 2.00
(49,2) (50,8)

.698 ∅ .625
.688 .624

( 17,73
17,48 ) (15,88
15,85) .25
(6,4)
∅ .406 (10,31)
∅ 2.000 .44 ∅ 4.00
1.998 2 MOUNTING HOLES BLEED PORT FOR
(11,2) (101,6)
VERTICAL MOUNTING
( 50,80
50,75 ) 1.00 1/8-27 N.P.T.F.
(25,4)
∅ 4.00 1.38 5.80
(101,6) (34,9) (147,3)

5
PF500 SERIES

TYPICAL MODEL CODE


PF5 01 H – XV A – 22 – 1 0

Pump Type Ports


Design
PF5 Fixed Displacement No Code Inlet No. 12 S.A.E.; Outlet No. 6 S.A.E.➀ Number
Checkball Pump Inlet No. 12 S.A.E.; Outlet 3/8 Medium
A Pressure Coned and Threaded,
0.5625-18 U.N.F.-2B Threaded➁
Output Flow Modification
(At 1800 rpm, at rated pressure)➀ B Inlet No. 12 S.A.E.; Outlet G 1/4 (B.S.P.)➂ Number
➀ Not recommended for operation above 8000 psi (560 bar).
01 0.21 gpm (0,79 L/min) Contact the fitting manufacturer for the pressure rating
04 0.33 gpm (1,25 L/min) of the fitting.
➁ High pressure port uses Autoclave Medium Pressure,
07 0.46 gpm (1,74 L/min) Butech M/P or equivalent fitting.
10 0.68 gpm (2,57 L/min) ➂ Outlet port uses British Standard Pipe fitting. Not
recommended for operation above 10 000 psi (700 bar).
➀ Output flows based on typical performance at
rated pressure. Refer to performance curves
for flows at lower pressures.
Split-Flow® Options (4 Piston Pump)➀
No Code Full flow from single outlet
Operating Pressure
Split-Flow® Cover Models:
No Code Standard Pressure
22 Two-pistons output + Two-pistons output
H High Pressure➀
31 Three-pistons output + One-piston output➁
➀ Requires “A” or “B” port option.
4X Four ports, each with one-piston output
2 Two pistons output + Two inactive pistons
Seals ➀ For outlet port sizes, locations and pump cover dimensions,
contact the sales department.
No Code Fluorocarbon (Viton® or Fluorel®) Seals with Buna-N (Nitrile) Shaft Seal
➁ Port for output flow designated by first digit is located at the
XE All EPR with High Pressure Shaft Seal➀ 12 o’clock position (for code “31”, three-piston output flow
exits the 12 o’clock port).
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
➀ Not available with High Pressure “H” option. Contact the sales department for recommended
operating conditions.

5
PF1000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm➁ rpm➁
PF1002-10 1.2 4,7 1.5 5,7 6000 420 8000 560 1800 3600
PF1003-10 1.7 6,6 2.1 7,9 6000 420 8000 560 1800 3600
PF1004-10 2.1 8,2 2.6 9,8 6000 420 8000 560 1800 3600
PF1005-10 2.9 11,0 3.5 13,2 6000 420 8000 560 1800 2800
PF1006-10 3.4 12,9 4.1 15,5 6000 420 8000 560 1800 2800
PF1007-10 4.1 15,7 5.0 18,9 4000 280 6000 420 1800 2800
PF1008-10 4.9 18,6 5.9 22,3 4000 280 6000 420 1800 2800
PUMP DESCRIPTION PF1002H-10 1.2 4,7 1.5 5,7 6000 420 10 000 700 1800 3600
PF1003H-10 1.7 6,6 2.1 7,9 6000 420 10 000 700 1800 3600
Fixed displacement checkball pumps, with PF1004H-10 2.1 8,2 2.6 9,8 6000 420 10 000 700 1800 3600
bi-directional shaft rotation, provide PF1005H-10 2.9 11,0 3.5 13,2 6000 420 10 000 700 1800 2800
constant direction of output flow regardless PF1006H-10 3.4 12,9 4.1 15,5 6000 420 10 000 700 1800 2800
of the direction of drive shaft rotation. ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.
Mounting ➁ Contact the sales department for applications requiring operation above rated speed. High speed
operation may require a pressurized inlet. Refer to “Inlet Conditions”.
S.A.E. A 2-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.
Shaft Options Minimum Inlet Pressure➀
Standard keyed shaft, 0.875 inch Operating Speed
(22.20 mm) diameter; Pump
1800 rpm 2200 rpm 2800 rpm 3600 rpm

Optional spline shaft, 0.873/0.872 inch Models psi bar psi bar psi bar psi bar
diameter standard S.A.E. 13 tooth, PF1002 0 0 0 0 0 0 5 0,4
16/32 D.P. 30° involute spline. PF1003 and PF1004 0 0 0 0 5 0,4 10➁ 0,7➁
PF1005, PF1006,
Outlet Port Options PF1007 and PF1008
0 0 5 0,4 10➁ 0,7➁ – –
Standard pressure models have S.A.E. ports. ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt).
The high pressure “H” option requires the ➁ Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. Refer to "Typical Model
Code" on page 8 for seal options.
use of outlet port option “A” (Autoclave
Medium Pressure, Butech M/P or equivalent
fittings), or outlet port option “B” (British
Standard Pipe fittings). PUMP SELECTION Fluid Guidelines
Inlet Conditions See page 28 for “Fluid Recommendations”.
The table shows specifications for standard
Pumps may require pressurized inlet pressure and high pressure “H” option Some pump models may require reduced
conditions at higher speeds. Failure to meet models. operating pressures when using low-
minimum inlet requirements will result in lubricity fluids.
Ordering a PF1000 Series, 10 Design, pump
slight flow reduction. Refer to the table. requires a complete model code specifying Because of the wide range of fluid
shaft, seal and outlet port options. Refer to characteristics, contact the sales
Seal Options “Typical Model Code” on page 8. department for a review of any application
Standard seals are Buna-N (Nitrile). Options using non-petroleum based fluids.
include Fluorocarbon (Viton® or Fluorel®), or Maximum Pressure
EPR for use with some phosphate ester fluids. Checkball pumps are especially suited Split-Flow® Provides Multiple Outlets
for applications susceptible to excessive PF1000 models with split-flow covers
Weight (Mass) pressure spikes. efficiently supply flows for multiple function
30 lb (14 kg) circuits. Piston outputs are grouped together
The intermittent pressures listed are
in the cover, with various piston flow splits
the maximum pressures a pump can
available in this four-piston pump. Refer to
sustain for occasional, short periods of
“Typical Model Code” on page 8 and contact
operation without appreciably reducing life
the sales department for availability.
expectancy.

6
PF1000 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized
inlet where required. Refer to the “Minimum Inlet Pressure” table on page 6.

7
PF1000 SERIES

INSTALLATION
All dimensions are shown in inches The drawing shows dimensions common to “Outlet Port Configurations” on page 29 and
(millimeters in parentheses) and are all PF1000 models. Note that the dimension “Typical Model Code” below to specify port.
nominal. See page 6 for spline shaft for the outlet port varies as shown,
data. Refer to Bulletin PSI.CB for general dependent on the type of port. Refer to
installation and operating recommendations.
7.88 OUTLET PORT — NO. 8 S.A.E.; OR 9/16 MEDIUM PRESSURE
(200,1) CONED AND THREADED, .8125-18 U.N.–2B THREADED
INLET PORT (AUTOCLAVE, BUTECH M/P OR EQUIVALENT);
2.094 2.094 3.95
NO. 16 S.A.E. OR G 3/8 (B.S.P.)
(53,19) (53,19) (100,3)

SQUARE KEY
.250 x 1.00
2.63 (6,4 x 25,0)
(66,8) 2.41 CONED AND
(61,1) THREADED,
OR S.A.E. PORT

2.35 B.S.P. PORT


.990 .875 (59,7)
.980 ∅ .873

( 25,15
24,89 ) (22,23
22,17)
.25
(6,4)

∅ 3.250 ∅ .438 (11,13) .50 ∅ 4.25


3.248 2 MOUNTING HOLES (12,7) BLEED PORT FOR (108,0)
VERTICAL MOUNTING
(82,55
82,50) 1.52 1/8-27 N.P.T.F. ∅ 5.00
(38,6) (127,0)
∅ 5.00 1.62 8.57
(127,0) (41,1) (217,6)

TYPICAL MODEL CODE


PF10 02 H – S XV A – 22 – 1 0

Pump Type Ports Design


PF10 Fixed Displacement No Code Inlet No. 16 S.A.E.; Outlet No. 8 S.A.E.➀ Number
Checkball Pump
Inlet No. 16 S.A.E.; Outlet 9/16 Medium
A Pressure Coned and Threaded,
0.8125-16 U.N.-2B Threaded➁
Output Flow Modification
(At 1800 rpm, at rated pressure)➀ B Inlet No. 16 S.A.E.; Outlet G 3/8 (B.S.P.)➂ Number
➀ Not recommended for operation above 8000 psi (560 bar).
02 1.5 gpm (5,7 L/min) Contact the fitting manufacturer for the pressure rating
03 2.1 gpm (7,9 L/min) of the fitting.
➁ High pressure port uses Autoclave Medium Pressure,
04 2.6 gpm (9,8 L/min) Butech M/P or equivalent fitting.
05 3.5 gpm (13,2 L/min) ➂ Outlet port uses British Standard Pipe fitting. Not
recommended for operation above 10 000 psi (700 bar).
06 4.1 gpm (15,5 L/min)
07 5.0 gpm (18,9 L/min)➁
08 5.9 gpm (22,3 L/min)➁ Split-Flow® Options (4 Piston Pump)➀
➀ Output flows based on typical performance No Code Full flow from single outlet
at rated pressure. Refer to performance
curves for flows at lower pressures. Split-Flow® Cover Models:
➁ Not available with high pressure "H" option. 22 Two-pistons output + Two-pistons output
31 Three-pistons output + One-piston output
4X Four ports, each with one-piston output
Operating Pressure
2 Two pistons output + Two inactive pistons
No Code Standard Pressure
➀ For outlet port sizes, locations and pump cover dimensions,
H High Pressure➀ contact the sales department.
➀ Requires “A” or “B” port option.

Seals
Drive Shaft
No Code All Buna-N (Nitrile)➀
No Code Keyed, 0.875 inch (22,20 mm) diameter
XE All EPR with High Pressure Shaft Seal➀
S S.A.E. Spline, 0.875 inch (22,20 mm)
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
➀ Not available with High Pressure “H” option. Contact the sales department for
recommended operating conditions.

8
PF2000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
S.A.E. Ports:
PF2007-2190 3.4 12,9 4.1 15,5 6000 420 6000 420 2000 2800
PF2008-2191 4.8 18,3 5.8 22,0 5000 350 6000 420 2000 2400
PF2009-2184 5.1 19,2 6.1 23,1 3000 210 4000 280 2000 2800
PF2012-2185 7.1 26,8 8.5 32,2 3000 210 4000 280 2000 2400
Coned and Threaded Outlet Port:➁
PF2007-2973 3.4 12,9 4.1 15,5 6000 420 10 000 700 1800 2800
PUMP DESCRIPTION B.S.P. Outlet Port:➂
Fixed displacement checkball pumps, with PF2007-3055 3.4 12,9 4.1 15,5 6000 420 10 000 700 1800 2800
bi-directional shaft rotation, provide ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.
constant direction of output flow regardless ➁ High pressure outlet port uses Autoclave Medium Pressure, Butech M/P or equivalent fitting.
of the direction of drive shaft rotation. ➂ Outlet port uses British Standard Pipe fitting.

Mounting
S.A.E. B 2-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.
Minimum Inlet Pressures ➀
Operating Speed
Shaft Options 2000 rpm 2400 rpm 2800 rpm
Standard keyed shaft, 0.875 inch Pump
Models psi bar psi bar psi bar
(22.22 mm) diameter;
PF2007 0 0 3 0,2 5 0,4
Optional spline shaft, 0.873/0.872 inch PF2008 0 0 5 0,4 – –
diameter standard S.A.E. 13 tooth, PF2009 0 0 3 0,2 5 0,4
16/32 D.P. 30° involute spline. Contact the PF2012 0 0 5 0,4 – –
sales department for model number. ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). Inlet pressures higher than 10 psig
(0,7 bar) require a high-pressure shaft seal.
Outlet Port Options
Standard pressure models have S.A.E. ports.
High pressure models use either coned
and threaded fittings (Autoclave Medium PUMP SELECTION Fluid Guidelines
Pressure, Butech M/P or equivalent), or
The “Specifications” table lists the most See page 28 for “Fluid Recommendations”.
B.S.P. fittings (British Standard Pipe).
commonly used standard models with Some pump models may require reduced
Inlet Conditions keyed shafts. Contact the sales department operating pressures when using low-
Pumps may require pressurized inlet for models with spline shafts, optional lubricity fluids.
conditions at higher speeds. Failure to meet seals and other extraordinary operating
requirements. Because of the wide range of fluid
minimum inlet requirements will result in characteristics, contact the sales
slight flow reduction. Refer to the table. Maximum Pressure department for a review of any application
Checkball pumps are especially suited using non-petroleum based fluids.
Seal Options
Standard seals are Buna-N (Nitrile). Contact for applications susceptible to excessive Split-Flow® Provides Multiple Outlets
the sales department for other seal options. pressure spikes.
PF2000 models with split-flow covers
The intermittent pressures listed are efficiently supply flows for multiple
Weight (Mass) the maximum pressures a pump can function circuits. Piston outputs are
30 lb (14 kg) sustain for occasional, short periods of grouped together in the cover, with various
operation without appreciably reducing life piston flow splits available in this six-piston
expectancy. pump. Contact the sales department for
Split-Flow® options and availability.

9
PF3000
PF2000
SERIES,SERIES
10 DESIGN

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to the “Minimum Inlet Pressure” table on page 9.

INSTALLATION
All dimensions are shown in inches The diameter of the pump cover and the threaded (Autoclave or Butech) fitting or a
(millimeters in parentheses) and are location of the outlet port varies as shown, B.S.P. (British Standard Pipe) fitting. Refer
nominal. See page 9 for optional spline dependent on the model. The port location to “Outlet Port Configurations” on page 29
shaft data. Refer to Bulletin PSI.CB for high-pressure models is shown printed and the “Specifications” table on page 9 for
for general installation and operating in gray. This port uses either a coned and model numbers to specify port.
recommendations.

OUTLET PORT — 3/4 MEDIUM PRESSURE


7.06 CONED AND THREADED, .750 –14 N.P.S.M. THREADED
(179,3) (AUTOCLAVE, BUTECH M/P, OR EQUIVALENT);
5.75 OR G 1/2 (B.S.P.)
3.19 INLET PORT
(146,0) SQUARE KEY (81,0) NO. 16 S.A.E. OUTLET PORT — NO. 8 S.A.E.
.25 x .75 (6,4 x 19,0)

3.00 3.01
(76,2)
(
.986 25,04
.979 24,87 ) 2.52
(76,5)

4.000 (64,0)

3.998

(
101,60
101,55 )
∅ (
.875 22,22
.874 22,20 )

∅ .562 (14,27) .25


2 MOUNTING (6,4)
∅ 5.00 ∅ 4.88
HOLES
(127,0) (124,0)
1.63 .63 ∅ 5.31 HIGH PRESSURE
6.88 (41,4) (16,0) (134,9) COVER
9.31
(174,8) (236,5)
∅ 5.69
9.37 HIGH PRESSURE (144,5)
(238,0) COVER

10
PF2000 SERIES SPECIAL MOUNTING

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
S.A.E. Ports:
PF2006-1808 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400
PF2008-1804 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400
N.P.T.F. Ports:
PF2006-1807 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400
PF2008-1802 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
PUMP DESCRIPTION shown in the “Minimum Inlet Pressure” table.

Fixed displacement checkball pumps, with


bi-directional shaft rotation, provide
constant direction of output flow regardless Minimum Inlet Pressure ➀
of the direction of drive shaft rotation. Operating Speed
2000 rpm 2400 rpm
Mounting Pump
Models psi bar psi bar
Special 4-bolt pattern. Refer to installation
All PF2000 Models
drawing. (Special Mounting)
0 0 5 0,4

Shaft ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). Inlet pressures higher than 10 psig
(0,7 bar) require a high-pressure shaft seal.
Available with 1.25 inch (31,75 mm)
diameter keyed shaft.
Outlet Port Options
Available with S.A.E. or N.P.T.F. ports. Refer PUMP SELECTION Split-Flow® Provides Multiple Outlets
to the “Specifications” table. These PF2000 Series pumps can efficiently
The “Specifications” table lists the most
supply flows for multiple function circuits.
Inlet Conditions commonly used standard models with
keyed shafts. Contact the sales department Split-Flow® models are available with
Pumps may require pressurized inlet
for models with optional seals and other isolator valves installed into the pump, to
conditions at higher speeds. Failure to meet
extraordinary operating requirements. separate one or more pistons from the main
minimum inlet requirements will result in
outlet. Up to six independent outlet flows
slight flow reduction. Refer to the table. Maximum Pressure are possible from this six-piston pump.
Seal Options Checkball pumps are especially suited When using isolator valves, high-pressure
Standard seals are Buna-N (Nitrile). Contact for applications susceptible to excessive models are limited to a maximum pressure
the sales department for other seal options. pressure spikes. of 6000 psi (420 bar).
The intermittent pressures listed are Contact the sales department for Split-Flow®
Weight (Mass) the maximum pressures a pump can model numbers.
43 lb (20 kg) sustain for occasional, short periods of
operation without appreciably reducing life
expectancy.
Fluid Guidelines
See page 28 for “Fluid Recommendations”.
Some pump models may require reduced
operating pressures when using low-
lubricity fluids.
Because of the wide range of fluid
characteristics, contact the sales
department for a review of any application
using non-petroleum based fluids.

11
PF2000 SERIES SPECIAL MOUNTING

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized
inlet where required. Refer to the “Minimum Inlet Pressure” table on page 11.

INSTALLATION
All dimensions are shown in inches Refer to Bulletin PSI.CB for general installation
(millimeters in parentheses) and are and operating recommendations.
nominal. Refer to “Outlet Port Configurations” on
These PF2000 Series models have a special page 29 and the “Specifications” table on
4-bolt mounting pattern shown below. page 11 for model numbers to specify ports.

INLET PORT — NO.12 S.A.E.


AMERICAN STANDARD NO. 1212 OR 3/4 N.P.T.F. OUTLET PORT — NO.10 S.A.E.
4.375 WOODRUFF KEY OR 1/2 N.P.T.F.
.375 x 1.50 (9,52 x 38,1) 3.81
(111,12)
.56 (96,8)
(14,2)
(
∅ 1.2486 31,714
1.2483 31,707 )

∅ 2.468
2.466

(
62,69
62,64 )

1.25
(
1.404 35,66
1.414 35,92 ) (31,75)

2.81 3.16 .38 ∅ 4.19


∅ .531 (13,49)
(71,4) (80,3) (9,7) (106,4)
4 MOUNTING HOLES
5.63 3.06 8.58
(143,0) (77,7) (217,9)

12
PF3000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm➁ rpm➁
PF3011-10 6.7 25,5 8.1 30,7 6000 420 8000 560 1800 2800
PF3015-10 8.3 31,5 10.0 37,8 6000 420 8000 560 1800 2500
PF3017-10 10.0 37,8 12.0 45,4 6000 420 8000 560 1800 2200
PF3021-10 12.0 45,4 14.4 54,5 4000 280 6000 420 1800 2500
PF3024-10 14.3 54,2 17.2 65,1 4000 280 6000 420 1800 2200
PF3011H-10 6.7 25,5 8.1 30,7 6000 420 10 000 700 1800 2800
PF3015H-10 8.3 31,5 10.0 37,8 6000 420 10 000 700 1800 2500
PUMP DESCRIPTION ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.
Fixed displacement checkball pumps, with ➁ Contact the sales department for applications requiring operation above rated speed. High speed
operation may require a pressurized inlet. Refer to “Inlet Conditions”.
bi-directional shaft rotation, provide
constant direction of output flow regardless
of the direction of drive shaft rotation. Minimum Inlet Pressure➀
Mounting Operating Speed
S.A.E. C 4-bolt pattern with 0.25 inch 1500 rpm 1800 rpm 2200 rpm 2500 rpm 2800 rpm
Pump
(6,4 mm) pilot engagement. Models psi bar psi bar psi bar psi bar psi bar

Shaft Options PF3011 0 0 0 0 5 0,4 7 0,5 10➁ 0,7➁


PF3015 0 0 3 0,2 7 0,5 10➁ 0,7➁ – –
Standard keyed shaft, 1.250 inch PF3017 0 0 5 0,4 10 0,7 – – – –
(31,75 mm) diameter; PF3021 0 0 3 0,2 7 0,5 10➁ 0,7➁ – –
Optional spline shaft, 1.248/1.247 inch PF3024 0 0 5 0,4 10 0,7 – – – –
diameter standard S.A.E. 14 tooth, ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt).
12/24 D.P. 30° involute spline. ➁ Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. Refer to "Typical Model
Code" on page 15 for seal options.
Outlet Port Options
Standard pressure models have S.A.E. ports.
The high pressure “H” option requires the
use of outlet port option “A” (Autoclave PUMP SELECTION Fluid Guidelines
Medium Pressure, Butech M/P or equivalent See page 28 for “Fluid Recommendations”.
The table shows specifications for standard
fittings), or outlet port option “B” (British pressure and high pressure “H” option Some pump models may require reduced
Standard Pipe fittings). models. operating pressures when using low-
lubricity fluids.
Inlet Conditions Ordering a PF3000 Series, 10 Design, pump
Pumps may require pressurized inlet requires a complete model code specifying Because of the wide range of fluid
conditions at higher speeds. Failure to meet shaft, seal and outlet port options. Refer to characteristics, contact the sales
minimum inlet requirements will result in “Typical Model Code” on page 15. department for a review of any application
slight flow reduction. Refer to the table. using non-petroleum based fluids.
Maximum Pressure
Seal Options Checkball pumps are especially suited Split-Flow® Provides Multiple Outlets
Standard seals are Buna-N (Nitrile). Options for applications susceptible to excessive PF3000 models with split-flow covers
include Fluorocarbon (Viton® or Fluorel®), or pressure spikes. efficiently supply flows for multiple
EPR for use with some phosphate ester fluids. The intermittent pressures listed are function circuits. Piston outputs are grouped
the maximum pressures a pump can together in the cover, with various piston
Weight (Mass) sustain for occasional, short periods of flow splits available in this eight-piston
62 lb (28 kg) operation without appreciably reducing life pump. Refer to “Typical Model Code” on
expectancy. page 15 and contact the sales department
for availability.

13
PF3000 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized
inlet where required. Refer to “Minimum Inlet Pressure” table on page 13.

14
PF3000 SERIES

INSTALLATION
All dimensions are shown in inches Refer to Bulletin PSI.CB for general installation the outlet port varies as shown, dependent
(millimeters in parentheses) and are and operating recommendations. on the type of port. Refer to “Outlet Port
nominal. The drawing shows dimensions common to Configurations” on page 29 and “Typical
See page 13 for spline shaft data. all PF3000 models. Note that the location of Model Code” below to specify port.

INLET PORT 7.97 CONED AND


NO. 24 S.A.E. (202,4) THREADED PORT
4.508 OUTLET PORT — NO. 12 S.A.E.; OR 3/4 MEDIUM PRESSURE
(114.50) 8.09 S.A.E. OR
(205,5) B.S.P. PORT CONED AND THREADED, .750 - 14 N.P.S.M. THREADED
2.254 3.94 (AUTOCLAVE , BUTECH M/P, OR EQUIVALENT);
SQUARE KEY OR G 3/4 (B.S.P.)
(57,25) (100,1)
.31 x 1.18 .60
(7,9 X 30,0)
(15,2)

3.63
(
1.391 35,33
1.381 35,08 ) 3.33 CONED AND (92,2)
(84,6) THREADED PORT
5.000

4.998

( 127,00
126,95 ) 3.17 S.A.E. OR
(
∅ 1.250 31,75
1.248 31.70 ) (80,5) B.S.P. PORT

∅ .563 (14,30) .25


5.88 4 MOUNTING HOLES (6,4) BLEED PORTS (3) ∅ 6.00
.50
(149.4) (12,7) NO. 6 S.A.E., (152,4)
2.25 9.00 90° APART ∅ 6.50
(57,2) (228,6) (165,1)

TYPICAL MODEL CODE


PF30 11 H – S XV A – 44 – 1 0

Pump Type Ports


Design
PF30 Fixed Displacement No Code Inlet No. 24 S.A.E.; Outlet No. 12 S.A.E.➀ Number
Checkball Pump Inlet No. 24 S.A.E.; Outlet 3/4 Medium
A Pressure Coned and Threaded,
3/4-14 N.P.S.M. Threaded➁
Output Flow Modification
(At 1800 rpm, at rated pressure)➀ B Inlet No. 24 S.A.E.; Outlet G 3/4 (B.S.P.)➂ Number
➀ Not recommended for operation above 8000 psi (560 bar).
11 8.1 gpm (30,7 L/min) Contact the fitting manufacturer for the pressure rating
15 10.0 gpm (37,8 L/min) of the fitting.
➁ High pressure port uses Autoclave Medium Pressure,
17 12.0 gpm (45,4 L/min)➁ Butech M/P or equivalent fitting.
21 14.4 gpm (54,5 L/min)➁ ➂ Outlet port uses British Standard Pipe fitting. Not
recommended for operation above 10 000 psi (700 bar).
24 17.2 gpm (65,1 L/min)➁
➀ Output flows based on typical performance at
rated pressure. Refer to performance curves
for flows at lower pressures. Split-Flow® Options (8 Piston Pump)➀
➁ Not available with high pressure "H" option. No Code Full flow from single outlet
Split-Flow® Cover Models:
44 Four-pistons output + Four-pistons output
Operating Pressure
53 Five-pistons output + Three-pistons output
No Code Standard Pressure
62 Six-pistons output + Two-pistons output
H High Pressure➀
71 Seven-pistons output + One-piston output
➀ Requires “A” or “B” port option.
8X Eight ports, each with one-piston output
4 Four pistons output + Four inactive pistons
Drive Shaft
➀ For outlet port sizes, locations and pump cover dimensions,
No Code Keyed, 1.250 inch (31,75 mm) diameter contact the sales department.

S S.A.E. Spline, 1.250 inch (31,75 mm)

Seals
No Code All Buna-N (Nitrile)➀
XE All EPR with High Pressure Shaft Seal➀
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
➀ Not available with High Pressure “H” option. Contact the sales department for
recommended operating conditions.

15
PF4000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm➁ rpm➁
PF4011-30 6.4 24,2 7.7 29,1 6000 420 8000 560 1800 2400
PF4016-30 9.2 35,0 11.1 42,0 6000 420 8000 560 1800 2400
PF4018-30 10.3 39,1 12.4 46,9 6000 420 8000 560 1800 2400
PF4020-30 11.6 44,1 14.0 53,0 6000 420 8000 560 1800 2400
PF4011H-30 6.0 23,0 7.3 27,6 10 000 700 10 000 700 1800 2400
PF4016H-30 8.7 33,1 10.5 39,7 10 000 700 10 000 700 1800 2400
PF4018H-30 10.0 38,1 12.1 45,8 8000 560 10 000 700 1800 2400
PUMP DESCRIPTION PF4020H-30 11.4 43,2 13.7 51,9 8000 560 10 000 700 1800 2400
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
Fixed displacement checkball pumps, with shown in the table below.
bi-directional shaft rotation, provide ➁ Contact the sales department for applications requiring operation above rated speed. High speed operation
may require a pressurized inlet. Refer to “Inlet Conditions”.
constant direction of output flow regardless
of the direction of drive shaft rotation.
Mounting Minimum Inlet Pressure➀
S.A.E. D 4-bolt pattern with 0.25 inch Operating Speed
(6,4 mm) pilot engagement. 1200 rpm 1500 rpm 1800 rpm 2400 rpm
Pump
Shaft Options Models psi bar psi bar psi bar psi bar
Standard keyed shaft, 1.250 inch PF4011 0 0 0 0 0 0 5 0,4
(31,75 mm) diameter; PF4016 0 0 0 0 0 0 5 0,4
PF4018 0 0 0 0 5 0,4 10➁ 0,7➁
Optional spline shaft, 1.248/1.247 inch
PF4020 0 0 5 0,4 10➁ 0,7➁ 15➁ 1,0➁
diameter standard S.A.E. 14 tooth,
12/24 D.P. 30° involute spline. ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt).
➁ Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. Refer to "Typical Model
Outlet Port Options Code" on page 18 for seal options.

Standard pressure models have S.A.E. ports.


High pressure “H” option models require
the use of outlet port option “A” (Autoclave PUMP SELECTION Some pump models may require reduced
Medium Pressure, Butech M/P or equivalent operating pressures when using low-
fittings), or outlet port option “B” (British The table shows specifications for standard lubricity fluids.
Standard Pipe fittings). pressure and high pressure “H” option
models. The optional “Low Lubricity Kit” provides
Refer to “Outlet Port Configurations” on an additional internal passage for improved
page 29 and “Typical Model Code” on Ordering a PF4000 Series, 10 Design, pump bearing lubrication when using low-
page 18 to specify outlet port. requires a complete model code specifying lubricity fluids. Refer to “Typical Model
shaft, seal and outlet port options. Refer to Code” on page 18.
Inlet Conditions “Typical Model Code” on page 18.
Because of the wide range of fluid
Pumps may require pressurized inlet Maximum Pressure characteristics, contact the sales
conditions at higher speeds. Failure to meet department for a review of any application
minimum inlet requirements will result in Checkball pumps are especially suited
for applications susceptible to excessive using non-petroleum based fluids.
slight flow reduction. Refer to the table.
pressure spikes. Split-Flow® Provides Multiple Outlets
Seal Options The intermittent pressures listed are the PF4000 models with split-flow covers
Standard seals are Buna-N (Nitrile). Options maximum pressures a pump can sustain efficiently supply flows for multiple
include Fluorocarbon (Viton® or Fluorel®) or for occasional, short periods of operation function circuits. Piston outputs are
EPR for use with some phosphate ester fluids. without appreciably reducing life grouped together in the cover, with various
expectancy. piston flow splits available in this ten-piston
Weight (Mass) pump. Refer to “Typical Model Code” on
111 lb (50 kg) Fluid Guidelines page 18 and contact the sales department
See page 28 for “Fluid Recommendations”. for availability.

16
PF3000
PF4000
SERIES,SERIES
10 DESIGN

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to the “Minimum Inlet Pressure” table on page 16.

INSTALLATION Variable Dimensions


All dimensions are shown in inches Outlet Port Option
(millimeters in parentheses) and are S.A.E. or B.S.P Port Coned and Threaded
nominal. See page 16 for spline shaft data. Variable Models Models Models Models
Refer to Bulletin PSI.CB for general installation Dimension PF4011, PF4016 PF4018, PF4020 PF4011, PF4016 PF4018, PF4020
and operating recommendations. A 8.59 (218,2) 8.66 (220,0) 8.46 (214,9) 8.53 (216,7)
The thickness of the cover and the location B 3.94 (100,2) 3.94 (100,2) 4.09 (103,8) 4.09 (103,8)
of the outlet port varies as shown, C 9.49 (241,1) 9.56 (242,9) 9.49 (241,1) 9.56 (242,9)
dependent on the port option.

6.364 A OUTLET PORT — NO. 12 S.A.E.; OR 3/4 MEDIUM PRESSURE


(161.65) CONED AND THREADED, .750 - 14 N.P.S.M. THREADED
3.182 4.06 INLET PORT (AUTOCLAVE MEDIUM PRESSURE, BUTECH M/P, OR EQUIVALENT);
(80,82) (103,2) NO. 24 S.A.E. OR G 3/4 (B.S.P.)
SQUARE KEY 1.50
.31 x 1.18 (38,1)
(7,9 X 30,0)

4.63
(117,5)
(
1.392 35,36
1.384 35,15 ) B

∅ 6.000
5.998

(152,40
152,35 )
(
∅ 1.250 31,75
1.248 31.70 ) .13
4.00
(101,6)
(3,4)
.25
∅ .812 (20,62) (6,4)
.50
4 MOUNTING HOLES .58 BLEED PORTS (3) (12,7)
8.00 (14,7) .75 NO. 6 S.A.E., 90° APART ∅ 7.50
(203,2) (19,1) (190,5)
2.25 BLEED PORT FOR
(57,2) C
VERTICAL MOUNTING — NO. 4 S.A.E.

17
PF3000
PF4000
SERIES,SERIES
10 DESIGN

TYPICAL MODEL CODE


PF40 11 H – S XV A L – 55 – 3 0

Pump Type Options


Design
Fixed Displacement No Code Standard Number
PF40
Checkball Pump L Low Lubricity Kit➀
➀ Provides an additional internal
passage for improved bearing
Output Flow lubrication when using low-
Modification
(At 1800 rpm, at rated pressure)➀ lubricity fluids.
Number
Standard: 7.7 gpm (29,1 L/min)
11
“H” Option: 7.3 gpm (27,6 L/min)
Ports
Standard: 11.1 gpm (42,0 L/min)
16 No Code Inlet No. 24 S.A.E.; Outlet No. 12 S.A.E.➀
“H” Option: 10.5 gpm (39,7 L/min)
Inlet No. 24 S.A.E.; Outlet 3/4 Medium
Standard: 12.4 gpm (46,9 L/min)
18 A Pressure Coned and Threaded,
“H” Option: 12.1 gpm (45,8 L/min)
3/4-14 N.P.S.M. Threaded➁
Standard: 14.0 gpm (53,0 L/min)
20 B Inlet No. 24 S.A.E.; Outlet G 3/4 (B.S.P.)➂
“H” Option: 13.7 gpm (51,9 L/min)
➀ Output flows based on typical performance at ➀ Not recommended for operation above 8000 psi (560 bar).
Contact the fitting manufacturer for the pressure rating
rated pressure. Refer to performance curves of the fitting.
for flows at lower pressures.
➁ High pressure port uses Autoclave Medium Pressure,
Butech M/P or equivalent fitting.
➂ Outlet port uses British Standard Pipe fitting. Not
Operating Pressure recommended for operation above 10 000 psi (700 bar).

No Code Standard Pressure


H High Pressure➀
Split-Flow® Options (10 Piston Pump)➀
➀ Requires “A” or “B” port option.
No Code Full flow from single outlet
Split-Flow® Cover Models:
Drive Shaft 55 Five-pistons output + Five-pistons output
No Code Keyed, 1.250 inch (31,75 mm) diameter 64 Six-pistons output + Four-pistons output
S S.A.E. Spline, 1.250 inch (31,75 mm) 73 Seven-pistons output + Three-pistons output
82 Eight-pistons output + Two-pistons output
Seals 91 Nine-pistons output + One-piston output
No Code All Buna-N (Nitrile)➀ 10X Ten ports, each with one-piston output
XE All EPR with High Pressure Shaft Seal➀ 5 Five pistons output + Five inactive pistons
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal ➀ For outlet port sizes, locations and pump cover dimensions,
contact the sales department.
➀ Not available with High Pressure “H” option. Contact the sales department for
recommended operating conditions.

18
PF4200 SERIES

Specifications➀
Output Flow Output Flow Maximum
at 1500 rpm➁ at 1800 rpm➁ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm➂ rpm➂
PF4203-10 1.8 6,9 2.2 8,3 8000 560 8000 560 1800 1800
PF4205-10 3.0 11,4 3.6 13,6 8000 560 8000 560 1800 1800
PF4208-10 4.3 16,4 5.2 19,7 8000 560 8000 560 1800 1800
PF4209-10 4.9 18,6 5.9 22,3 8000 560 8000 560 1800 1800
PF4210-10 5.6 21,1 6.7 25,4 8000 560 8000 560 1800 1800
PF4203H-10 1.5 5,9 1.9 7,2 15 000 1040 20 000 1380 1800 1800
PF4205H-10 2.6 10,0 3.2 12,1 15 000 1040 20 000 1380 1800 1800
PUMP DESCRIPTION PF4208H-10 4.0 15,4 4.9 18,5 12 000 830 17 000 1170 1800 1800
PF4209H-10 4.6 17,6 5.6 21,2 12 000 830 17 000 1170 1800 1800
These fixed displacement high-pressure PF4210H-10 5.4 20,4 6.5 24,6 10 000 700 15 000 1040 1800 1800
checkball pumps are capable of intermittent
➀ Specifications are based on the use of mineral oil operating within proper viscosity guidelines. Refer to
pressures to 20 000 psi (1380 bar). “Fluid Guidelines” below and on page 28.
➁ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
They are compatible with a wide range shown in the table.
of fluids including diesel calibration fluid, ➂ Contact the sales department for applications requiring operation above maximum speed.
Skydrol and other phosphate ester fluids,
various military fluids, and other low-
viscosity or low-lubricity fluids.
Minimum Inlet Pressure➀
Bi-directional shaft rotation provides
constant direction of output flow regardless Operating Speed
of the direction of drive shaft rotation. Pump
1200 rpm 1500 rpm 1800 rpm
Models psi bar psi bar psi bar
Mounting PF4203 0 0 0 0 0 0
S.A.E. D 4-bolt pattern with 0.25 inch PF4205 0 0 0 0 0 0
(6,4 mm) pilot engagement. PF4208 0 0 0 0 5 0,4
PF4209 0 0 5 0,4 10 0,7
Shaft Options PF4210 0 0 5 0,4 10 0,7
Standard keyed shaft, 1.250 inch ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt).
(31,75 mm) diameter;
Optional spline shaft, 1.248/1.247 inch
diameter standard S.A.E. 14 tooth,
12/24 D.P. 30° involute spline. High pressure shaft seals are standard on all The intermittent pressures listed are
Outlet Port Options PF4200 Series models. the maximum pressures a pump can
Weight (Mass) sustain for occasional, short periods of
Standard pressure models have S.A.E. ports. operation without appreciably reducing life
High pressure “H” option models require 140 lb (64 kg) expectancy.
the use of outlet port option “A” (Autoclave
Medium Pressure, Butech M/P or equivalent PUMP SELECTION Fluid Guidelines
fittings), or outlet port option “B” (British See page 28 for “Fluid Recommendations”.
Standard Pipe fittings). The table shows specifications for standard
pressure and high pressure “H” option Some pump models may require reduced
Inlet Conditions models. Refer to “Typical Model Code” on operating pressures when using low-
Pumps may require pressurized inlet page 21 to specify shaft, seal and outlet lubricity fluids.
conditions at higher speeds. Failure to meet port options. Because of the wide range of fluid
minimum inlet requirements will result in characteristics, contact the sales
slight flow reduction. Refer to the table. Maximum Pressure department for a review of any application
Checkball pumps are especially suited using non-petroleum based fluids.
Seal Options for applications susceptible to excessive
Options include Fluorocarbon (Viton® pressure spikes.
or Fluorel®) or EPR for use with some
phosphate ester fluids.

19
PF4200 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to the “Minimum Inlet Pressure” table on page 19.

20
PF4200 SERIES

INSTALLATION
All dimensions are shown in inches The drawing shows dimensions common As shown, the outlet port on these pumps
(millimeters in parentheses) and are to all PF4200 Series pumps. Note, however, is machined in a block integrally mounted
nominal. See page 19 for spline shaft data. that Model PF4203 has three pistons, rather to the pump barrel. Refer to “Outlet Port
Refer to Bulletin PSI.CB for general installation than five. Configurations” on page 29 and “Typical
and operating recommendations. Model Code” below to specify the port.

OUTLET PORT — NO. 8 S.A.E.; OR 9/16 MEDIUM PRESSURE


6.364 9.93 CONED AND THREADED, .8125-16 U.N.-2B THREADED
(161,65) (252,3) (AUTOCLAVE, BUTECH M/P OR EQUIVALENT);
3.182 OR G 1/2 (B.S.P.)
4.06 INLET PORT
(80,82) (103,1) NO. 24 S.A.E.
SQUARE KEY
.31 x 1.18 (7,9 x 30,0) .13
(3,4)
4.62
(117,3)
(
1.392 35,36
1.384 35,15 ) 5.18
(131,6)
∅ 6.000
3.13 5.998
(79,4) (152,40
152,35 )
(
∅ 1.250 31,75
1.248 31,70 )

∅ .812 (20,62)
.25 1.50
8.00 4 MOUNTING HOLES (38,1) .48 .50
(203,2) (6,4) .58 (12,1) (12,7)
(14,7) ∅ 8.00
BLEED PORTS (3) — NO. 6 S.A.E., 90° APART .75 (203,2)
(19,0)
2.25 11.31 BLEED PORT FOR
(57,2) (287,3) VERTICAL MOUNTING — NO. 4 S.A.E.

TYPICAL MODEL CODE


PF42 03 H – S XE A – 1 0

Pump Type Ports


Design
PF42 Fixed Displacement No Code Inlet No. 24 S.A.E.; Outlet No. 8 S.A.E.➀ Number
Checkball Pump Inlet No. 24 S.A.E.; Outlet 9/16 Medium
A Pressure Coned and Threaded,
.8125-16 U.N.-2B Threaded➁
Output Flow Modification
B Inlet No. 24 S.A.E.; Outlet G 1/2 (B.S.P.)➂ Number
(At 1800 rpm, at rated pressure)➀➁
➀ Not recommended for operation above 8000 psi (560 bar).
Standard: 2.2 gpm (8,3 L/min) Contact the fitting manufacturer for the pressure rating
03
“H” Option: 1.9 gpm (7,2 L/min) of the fitting.
Standard: 3.6 gpm (13,6 L/min) ➁ High pressure port uses Autoclave Medium Pressure,
05 Butech M/P or equivalent fitting.
“H” Option: 3.2 (12,1 L/min)
➂ Outlet port uses British Standard Pipe fitting. Not
Standard: 5.2 gpm (19,7 L/min) recommended for operation above 10 000 psi (700 bar).
08
“H” Option: 4.9 gpm (18,5 L/min)
Standard: 5.9 gpm (22,3 L/min)
09
“H” Option: 5.6 gpm (21,2 L/min) Seals
Standard: 6.7 gpm (25,4 L/min)
10 XE All EPR with High Pressure Shaft Seal➀
“H” Option: 6.5 gpm (24,6 L/min)
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
➀ Output flows based on typical perform-
ance at rated pressure. Refer to ➀ Contact the sales department for recommended operating conditions for any
performance curves for flows at lower application using non-petroleum based fluids.
pressures.
➁ Model PF4203 has three pistons; other
models have five pistons.
Drive Shaft
No Code Keyed, 1.250 inch (31,75 mm) diameter
Operating Pressure S S.A.E. Spline, 1.250 inch (31,75 mm)
No Code Standard Pressure
H High Pressure➀
➀ Requires “A” or “B” port option.

21
PF4300 SERIES

Specifications
Output Flow Output Flow Output Flow
at 1200 rpm➀ at 1500 rpm➀ at 1800 rpm➀ Maximum
Pressure Rated Maximum
Pump U.S. U.S. U.S. Speed Speed
Models gpm L/min gpm L/min gpm L/min psi bar rpm➁ rpm➁
PF4303-11 1.5 5,6 1.8 6,9 2.2 8,3 8000 560 1200 1800
PF4304-11 2.1 8,1 2.7 10,1 3.2 12,1 8000 560 1200 1800
PF4305-11 2.5 9,3 3.1 11,7 3.7 14,0 8000 560 1200 1800
PF4306-11 3.1 11,6 3.8 14,5 4.6 17,4 8000 560 1200 1800
PF4308-11 3.6 13,6 4.5 17,0 5.4 20,4 8000 560 1200 1800
PF4309-11 4.0 15,1 5.0 18,9 6.0 22,7 8000 560 1200 1800
PF4310-11 4.5 17,1 5.7 21,4 6.8 25,7 8000 560 1200 1800
PUMP DESCRIPTION PF4312-11 5.5 20,7 6.8 25,9 8.2 31,0 8000 560 1200 1800
PF4303H-11 1.3 4,8 1.6 6,2 2.0 7,5 15 000 1040 1200 1800
These fixed displacement checkball pumps PF4304H-11 2.0 7,6 2.5 9,5 3.1 11,7 12 000 830 1200 1800
are compatible with a variety of water-based PF4305H-11 2.3 8,9 2.9 11,0 3.6 13,6 10 000 700 1200 1800
fluids. Bi-directional shaft rotation provides PF4306H-11 2.9 11,1 3.7 13,9 4.4 16,6 10 000 700 1200 1800
constant direction of output flow regardless PF4308H-11 3.5 13,2 4.3 16,5 5.3 19,9 10 000 700 1200 1800
of the direction of drive shaft rotation. PF4309H-11 3.9 14,7 4.8 18,2 5.9 22,3 10 000 700 1200 1800
PF4310H-11 4.4 16,7 5.5 21,0 6.7 25,3 10 000 700 1200 1800
Single-Fluid Lubrication Design PF4312H-11 5.4 20,4 6.7 25,6 8.1 30,7 10 000 700 1200 1800
The checkball design uses the pumped ➀ Output flow based on typical performance using water glycol fluid at maximum pressure with pressurized
fluid for internal bearing lubrication. This inlet where required, as shown in the table below.
eliminates the potential for fluid cross- ➁ Contact the sales department for operation above the rated speed of 1200 rpm.

contamination, possible in other designs


with isolated lubrication. It also avoids the
cost of a separate lubrication circuit. Minimum Inlet Pressure ➀
These pumps are ideal for use in wellhead Operating Speed
safety control systems, other subsea Pump 1200 rpm 1500 rpm 1800 rpm
applications, industrial equipment including Models
psi bar psi bar psi bar
hydroform presses, and other applications
PF4303, PF4304,
requiring fire-resistant fluids. PF4305 and PF4306
0 0 0 0 0 0

Mounting PF4308 0 0 0 0 5 0,4


PF4309 0 0 5 0,4 10 0,7
S.A.E. D 4-bolt pattern with 0.25 inch PF4310 0 0 5 0,4 15 1,0
(6,4 mm) pilot engagement. PF4312 0 0 5 0,4 15 1,0
Shaft Options ➀ Values shown are based on fluid viscosity of 33 SUS (1,9 cSt).

Standard keyed shaft, 1.250 inch


(31,75 mm) diameter;
Optional spline shaft, 1.248/1.247 inch minimum inlet requirements will result in Maximum Pressure
diameter standard S.A.E. 14 tooth, slight flow reduction. Refer to the table. The maximum pressures listed are the
12/24 D.P. 30° involute spline. highest pressures a pump can sustain for
Standard Seals
occasional, short periods of operation without
Outlet Port Options Fluorocarbon (Viton® or Fluorel®) with high- appreciably reducing life expectancy.
Standard pressure models have S.A.E. ports. pressure shaft seal.
High pressure “H” option models require Special Fluid Operation
the use of outlet port option “A” (Autoclave
Weight (Mass)
Because of the wide range of water-based
Medium Pressure, Butech M/P or equivalent 116 lb (53 kg) fluid characteristics, contact the sales
fittings), or outlet port option “B” (British department for a review of any application
Standard Pipe fittings). PUMP SELECTION using non-petroleum based fluids.
Inlet Conditions The table shows specifications for standard
Pumps may require pressurized inlet pressure and high pressure “H” option models.
conditions at higher speeds. Failure to meet Refer to “Typical Model Code” on page 24 to
specify shaft and outlet port options.

22
PF4300 SERIES

Typical Performance Curves

Typical performance curves are based on 33 SUS (1,9 cSt) water glycol fluid with pressurized
inlet where required. Refer to the “Minimum Inlet Pressure” table on page 22.

23
PF4300 SERIES

INSTALLATION
All dimensions are shown in inches Note that Models PF4303 and PF4304 As shown, the outlet port on these pumps
(millimeters in parentheses) and are have three pistons; Models PF4305, is machined in a block integrally mounted
nominal. See page 22 for spline shaft data. PF4308, PF4309 and PF4310 have five to the pump barrel. Refer to “Outlet Port
Refer to Bulletin PSI.CB for general installation pistons; and Models PF4306 and PF4312 Configurations” on page 29 and “Typical
and operating recommendations. have six pistons. Model Code” below to specify the port.

6.364 9.93 OUTLET PORT — NO. 8 S.A.E.; OR 9/16 MEDIUM PRESSURE


(161,6) (252,2) CONED AND THREADED, .8125–16 U.N.–2B THREADED
3.182 (AUTOCLAVE MEDIUM PRESSURE, BUTECH M/P, OR EQUIVALENT);
4.06 INLET PORT
(80,82) OR G 1/2 (B.S.P.)
SQUARE KEY (103,1) NO. 24 S.A.E.
.31 X 1.18 (7,9 X 30,0) .13
(3,4) 5.18 CONED AND
4.62 (131,6) THREADED PORT
(117,3)
(
1.392 35,36
1.384 35,15 ) 5.09
(129,3)
S.A.E. OR
B.S.P. PORT
∅ 6.000
5.998

(152,40
152,35 )
3.13
∅ 1.250 31,75
1.248 31,70( )
(79,4)

∅ .812 (20,62)
8.00 .25 1.50 .50
4 MOUNTING HOLES (38,1)
(203,2) (6,4) .58 (12,7)
.75 (14,7) ∅ 7.50
BLEED PORTS (3) — NO. 6 S.A.E., 90° APART
(19,0) (190,5)
2.25 10.73 BLEED PORT FOR
(57,2) (272,5) VERTICAL MOUNTING — NO. 4 S.A.E.

TYPICAL MODEL CODE


PF43 03 H – S XV A – 1 1

Pump Type Ports


Design
Fixed Displacement No Code Inlet No. 24 S.A.E.; Outlet No. 8 S.A.E.➀ Number
PF43
Checkball Pump Inlet No. 24 S.A.E.; Outlet 9/16 Medium
A Pressure Coned and Threaded,
.8125-16 U.N.-2B Threaded➁
Modification
Output Flow B Inlet No. 24 S.A.E.; Outlet G 1/2 (B.S.P.)➂ Number
(At 1800 rpm, at ➀ Not recommended for operation above 8000 psi (560 bar).
maximum pressure)➀➁ Contact the fitting manufacturer for the pressure rating
of the fitting.
Standard: 2.2 gpm (8,3 L/min)
03 ➁ High pressure port uses Autoclave Medium Pressure,
“H” Option: 2.0 gpm (7,5 L/min) Butech M/P or equivalent fitting.
Standard: 3.2 gpm (12,1 L/min) ➂ Outlet port uses British Standard Pipe fitting. Not
04
“H” Option: 3.1 gpm (11,7 L/min) recommended for operation above 10 000 psi (700 bar).
Standard: 3.7 gpm (14,0 L/min)
05
“H” Option: 3.6 gpm (13,6 L/min)
Standard: 4.6 gpm (17,4 L/min) Seals
06
“H” Option: 4.4 gpm (16,6 L/min) XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
Standard: 5.4 gpm (20,4 L/min)
08
“H” Option: 5.3 gpm (19,9 L/min)
Standard: 6.0 gpm (22,7 L/min) Drive Shaft
09
“H” Option: 5.9 gpm (22,3 L/min) No Code Keyed, 1.250 inch (31,75 mm) diameter
Standard: 6.8 gpm (25,7 L/min) S S.A.E. Spline, 1.250 inch (31,75 mm)
10
“H” Option: 6.7 gpm (25,3 L/min)
Standard: 8.2 gpm (31,0 L/min)
12 Operating Pressure
“H” Option: 8.1 gpm (30,7 L/min)
➀ Output flows based on typical perform- No Code Standard Pressure
ance at maximum pressure. Refer to H High Pressure➀
performance curves for flows at lower
pressures. ➀ Requires “A” or “B” port option.
➁ Models PF4303 and PF4304 have
three pistons; Models PF4305, PF4308,
PF4309 and PF4310 have five pistons;
Models PF4306 and PF4312 have six
pistons.

24
PF6000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure➁ Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
Outlet Block with Coned and Threaded Port: ➂
PF6023-3167 10.5 40,0 12.7 48,0 15 000 1040 15 000 1040 1800 1800
Outlet Block with S.A.E., Coned and Threaded, or B.S.P. Port: ➂➃
PF6033-3169 18.3 69,3 22.0 83,2 10 000 700 10 000 700 1800 1800
PF6046-3174 26.0 98,7 31.3 118,4 8000 560 8000 560 1800 1800
Standard S.A.E. 4-Bolt Flange Outlet Port:
PF6054-2946 29.5 111,6 35.4 134,0 6000 420 6000 420 1800 2400
PUMP DESCRIPTION PF6070-3186 39.6 150,1 47.6 180,1 6000 420 6000 420 1800 2300
PF6080-2989 45.0 170,3 54.0 204,4 5500 380 5500 380 1800 2200
Fixed displacement checkball pumps, ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required,
with bi-directional shaft rotation, provide as shown in the table below.
constant direction of output flow regardless ➁ Contact the sales department for applications requiring higher intermittent operating pressures.
➂ High pressure Coned and Threaded outlet port uses Autoclave Medium Pressure, Butech M/P or
of the direction of drive shaft rotation. equivalent fitting. Refer to “Outlet Port Block Kits” on page 27.
➃ B.S.P. outlet port uses British Standard Pipe fitting. Refer to “Outlet Port Block Kits” on page 27.
Mounting
S.A.E. E 4-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement; Minimum Inlet Pressure ➀
Shaft Options Operating Speed
1200 rpm 1500 rpm 1800 rpm 2400 rpm
Standard keyed shaft, 1.750 inch Pump
(44,45 mm) diameter; Models psi bar psi bar psi bar psi bar
PF6023 0 0 5 0,4 10 0,7 – –
Optional spline shaft, 1.748/1.747 inch
PF6033 0 0 10 0,7 15 1,0 – –
diameter standard S.A.E. 13 tooth, 8/16
PF6046 0 0 5 0,4 10 0,7 – –
D.P. 30° involute spline. Contact the sales
PF6054 0 0 5 0,4 5 0,4 10 0,7
department for model number.
PF6070 0 0 5 0,4 10 0,7 10➁ 0,7➁
Outlet Port Options PF6080 5 0,4 5 0,4 10 0,7 15➁ 1,0➁

Higher pressure models (PF6023, PF6033 ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). All PF6000 Series pumps have a
high-pressure shaft seal.
and PF6046) require an outlet port block kit. ➁ Refer to maximum speeds indicated in the “Specifications” table.
Refer to page 27. Standard pressure models
(PF6054, PF6070 and PF6080) have outlet
ports with a pattern for standard 1 inch
S.A.E. 4-bolt flange. PUMP SELECTION Split-Flow® Provides Multiple Outlets
The “Specifications” table lists the most Split-Flow® models efficiently supply flows
Inlet Conditions for multiple function circuits.
Pumps may require pressurized inlet commonly used standard models with
conditions at higher speeds. Failure to meet keyed shafts. Contact the sales department PF6000 Series models are available with
minimum inlet requirements will result in for model numbers with spline shafts, individual piston outputs grouped together
slight flow reduction. Refer to the table. optional seals and other extraordinary in the barrel or cover. Various piston flow
operating requirements. splits are available in this ten-piston pump.
Seal Options Models PF6033 and PF6046 are also available
Maximum Pressure with isolator valves, to separate one or more
Standard seals are Fluorocarbon (Viton®
or Fluorel®) with high-pressure shaft seal. Checkball pumps are especially suited pistons from the main outlet. Up to ten
Contact the sales department for other seal for applications susceptible to excessive independent flows are possible from these
options. pressure spikes. ten-piston pumps. When using isolator
The intermittent pressures listed are the valves, high-pressure models are limited to
Weight (Mass) maximum pressures a pump can sustain for a maximum pressure of 6000 psi (420 bar).
PF6023, PF6033 and PF6046: occasional, short periods of operation without Contact the sales department for Split-Flow®
240 lb (109 kg); appreciably reducing life expectancy. options and availability.
PF6054, PF6070 and PF6080:
330 lb (150 kg).
25
PF6000 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to the “Minimum Inlet Pressure” table on page 25.

26
PF6000 SERIES

INSTALLATION The block is not included with the pump. A kit, Outlet Port Block Kits
which includes mounting bolts and o-rings,
All dimensions are shown in inches must be ordered separately. Refer to the Port Type Kit Number
(millimeters in parentheses) and are table and to “Outlet Port Configurations” on Model PF6023:
nominal. Refer to page 25 for optional page 29 to specify the port. Coned and Threaded➀ KP60239131
spline shaft data. Refer to Bulletin PSI.CB Models PF6033 and PF6046:
for general installation and operating Models PF6054, PF6070 and PF6080 No. 16 S.A.E.➁ KP60339132
recommendations. As shown, these models have an auxiliary Coned and Threaded➀ KP60339133
inlet port in the cover, which provides more G 3/4 (B.S.P.)➂ KP60339134
Models PF6023, PF6033 and PF6046 fluid to improve the filling of the piston ➀ High pressure outlet port uses Autoclave
The drawing shows dimensions common to pumping chambers. Use of this port will Medium Pressure, Butech M/P or equivalent
fitting.
these models. Note, however, that Model increase volumetric efficiency. ➁ Not recommended for operation above 8000 psi
PF6023 has eight pistons, rather than ten. (560 bar). Contact the fitting manufacturer for
The drawing shows dimensions common the pressure rating of the fitting.
As shown, the outlet port on these high- to these three models. Note, however, the ➂ Outlet port uses British Standard Pipe fitting.
Not recommended for operation above 10 000 psi
pressure models is machined in a block, different dimensions for the outlet port and (700 bar).
which mounts axially on the pump barrel. the overall length for model PF6080.

8.839 INLET PORT — PATTERN FOR STANDARD


(224,51) 2-1/2 INCH S.A.E. 4-BOLT FLANGE (CODE 61)
PORT TYPE MUST BE SPECIFIED (REQUIRED OUTLET
3.75 4.28 PORT BLOCK MUST BE ORDERED SEPARATELY)
(95,2) (108.7)
SQUARE KEY
.44 x 1.88 (11,2 x 47,8)

5.81
(
1.946 49,43
1.936 49,17 ) (147,6)
6.500
6.498

(165,10
165,05 )
1.750
1.748 (44,45
44,40 )

.13
4.42 .812 (20,62) (3,3) .94 10.88
(112,3) 4 MOUNTING HOLES (23,9) (276,4)
5.31 .25 4.41
(134,9) (6,4) (112,0) BLEED PORTS (3) — NO. 8 S.A.E. 90° APART
10.62 2.92 12.19
(269,7) (74,2) (309,7)
13.94
(354,1)

Models PF6023-3167, PF6033-3169 and PF6046-3174

11.94 MODEL
INLET PORT — PATTERN FOR STANDARD 2-1/2 INCH (303,3) PF6080
S.A.E. 4-BOLT FLANGE (CODE 61) 11.54 OUTLET PORT — PATTERN FOR STANDARD
(293,0) 1 INCH S.A.E. 4-BOLT FLANGE (CODE 62)
3.75 2.92
(74,2) 4.28 5.31
(95,2)
(108,7) (134,9)
SQUARE KEY
.44 x 1.88
(11,2 x 47,8) 5.81
(147,6)
6.500
6.498 7.50
( 165,10
165,05 ) (190,5)

1.946
1.936 (
1.750 44,45
1.748 44,40 )
( )
49,42
49,16
.13
4.419 (3,3) .25 BLEED PORTS (3) AUXILIARY INLET PORT
(112,24) ∅ .812 (20,62) (6,4) NO. 8 S.A.E. NO. 16 S.A.E.
8.839 4 MOUNTING HOLES .94 90º APART
(224,51) (23,9) 4.41
10.62 15.18 10.88
(112,0)
(269,7) (385,6) (276,4)
15.59 MODEL
(396,0) PF6080

Models PF6054-2946, PF6070-3186 and PF6080-2989

27
PF3000
FLUID
SERIES,
GUIDELINES
10 DESIGN

FLUID RECOMMENDATIONS Hydraulic Fluid Viscosity➀


Mineral Oil Operating
Minimum Maximum Start-up➁ Optimum
A high-grade premium petroleum-based Pump
fluid should be used to assure long Models SUS cSt SUS cSt SUS cSt SUS cSt
component and system life. The fluid Fixed Displacement Pumps:
should have a combination of anti-wear, PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70
demulsibility, rust protection, oxidation- PF1000-10 59 10 1911 413 3706 800 98 to 324 20 to 70
resistant and foam-resistant properties.
PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70
Special Fluids PF2000➁ 34 2,3 1911 413 1911 413 98 to 324 20 to 70
Various pump models are available for use PF3000-10 59 10 1911 413 3706 800 98 to 342 20 to 70
with water-based fluids, diesel calibration PF4000-30 34 2,3 1911 413 1911 413 98 to 324 20 to 70
fluids, phosphate ester fluids, machining PF4200-10 34 2,3 1911 413 1911 413 98 to 324 20 to 70
coolant, brake fluid, various military fluids PF4300-11 31 1,5 927 200 927 200 – –
and other special fluids.
PF6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
PF4300 Series pumps are compatible with Mechanical Variable Delivery Pumps:
a variety of water-based fluids. Refer to
PV4000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
page 22 for specifications for these models,
which are specifically rated for use with PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
low-lubricity fluids. Hydraulic Variable Delivery Pumps:

Some pump models may require reduced PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
operating pressures when using low- ➀ Fluid conditions outside the “Optimum” range may result in reduced output, requiring pressurized inlet
conditions. Contact the sales department.
lubricity fluids. ➁ Models with special mounting.
Because of the wide range of fluid
characteristics, contact the sales
department for a review of any application
using non-petroleum based fluids.
MINIMUM FILTRATION LEVELS INSTALLATION AND OPERATION
Viscosity Specifications Pump inlet: 150 µ nominal; Refer to separate Bulletin PSI.CB for
Using fluid with the correct viscosity range general installation and operating
is critical to achieving long component life. Pressure or return line: 25 µ nominal.
recommendations.
Fluid conditions outside the “Optimum” While finer filtration levels than these
are desirable and will result in longer That brochure includes information on
range shown in the table may result in mounting, shaft loading, sizing inlet pipe
reduced pump output, requiring pressurized component life, restricting flow to the
pump inlet should be avoided. Minimum and hose, air bleed procedures and initial
inlet conditions. For more information, start-up. Guidelines for maintenance, repair
contact the sales department. recommended inlet conditions must be
maintained. and trouble-shooting are also included.
If a system component fails resulting in fluid
contamination, it is important to drain and
clean the reservoir, all lines, filter screens
and all components. Refill with new fluid.

28
OUTLET PORT CONFIGURATIONS

PORT DESCRIPTIONS Coned and Threaded Ports The recommended fitting has a recessed
seal cavity formed by a shoulder on the
Dynex pumps are available with outlet ports underside of the flanged wrench flat (Voss
suitable for use at various pressure ranges. TUBING GLAND NUT
“Peflex”, Form B Shoulder Seal; or Parker
Refer to the appropriate “Specification Type E, “EOlastic” Seal; or equivalent).
Table” or “Typical Model Code” to specify
the required port. B.S.P. ports are not recommended for
operation above 10 000 psi (700 bar).
Contact the fitting manufacturer to ensure SLEEVE Contact the fitting manufacturer, to ensure
the selected fittings are rated for the PUMP
WEEP the selected fittings are rated for the
maximum pump operating pressure. COVER
HOLE
maximum pump operating pressure.

S.A.E. Straight Thread Ports Typical Coned and Threaded


port connection S.A.E. 4-Bolt Flange Ports
High-pressure pumps are available with
COUPLING coned and threaded outlet ports, which use FLANGE
Autoclave Medium Pressure, Butech M/P, or BOLTS

equivalent fittings.
These fittings provide a metal-to-metal seal O-RING
O-RING
with an interference fit, not requiring an
PUMP o-ring. The gland nut holds the sleeve and
COVER
tubing against the cone surface. PUMP
COVER
A weep hole, visible on the outside of
Typical S.A.E. Straight Thread the pump cover, acts as an indicator of Typical S.A.E. 4-Bolt Flange
port connection port connection
any abnormal leakage caused by system
The Straight Thread connection (S.A.E. conditions (i.e., excessive pressure). It allows Flange connections are often used for
J1926/1) is sometimes referred to as an any fluid which does leak past the sealing higher flows requiring larger diameter
S.A.E. O-ring Boss, or ORB. The port consists surfaces to escape, preventing pressure tubing. The port consists of an unthreaded
of a machined spotface surface, a tapered build-up and possible damage. port with four bolt holes in a rectangular
seal cavity and a straight thread port. pattern on a machined face around the port
The fitting forms a seal by compressing the British Standard Pipe Ports (S.A.E. J518).
o-ring in the seal cavity with the underside A typical fitting consists of a flanged head
of the flanged wrench flat. Some adjustable with a welded tube and a captive flange
fittings, such as elbows and tees, use a COUPLING
with bolt holes. A seal is formed by an
locknut with a captive backup washer for o-ring in the groove on the underside
compression. SEAL RING
mounting surface of the flange head. As the
S.A.E. Straight Thread ports are not flange bolts are alternately tightened, the
recommended for operation above SHOULDER
o-ring is compressed between the flange
8000 psi (560 bar). Also, the maximum head and the machined face on the pump.
PUMP
pressure of pumps with No. 12 S.A.E. outlet COVER To make mounting easier in tight spaces a
ports may be limited by the pressure rating two-piece split-flange is often used.
of the available fitting. Contact the fitting
Typical port connection with
manufacturer for ratings. British Standard Pipe (Parallel)
fitting with shoulder

High-pressure pumps are available with flat


face ports with British Standard Pipe (B.S.P.)
parallel threads (BS 2779 or ISO 228), ideal
for use on some European applications.
The fitting forms a seal by compressing a
flat elastomer ring on a machined spotface
surface. There are several sealing methods
for these ports.

29
SPECIFICATIONS

Variable Delivery
Checkball Piston Pumps
Also refer to "Checkball Pump Installation and Operating
Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf)

CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: sales@dynexhydraulics.com

Power Units & Systems


Dynex/Rivett Inc.
54 Nickerson Road
Ashland, MA 01721 U.S.A.
Tel: 508-881-5110
FAX: 508-881-6849
E-mail: ashland@dynexhydraulics.com

European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: sales@dynexhydraulics.co.uk

Download Dynex Product Specifications!

BROCHURE NOTES:
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative or the sales department for the most current specifications before ordering.
Dynex reserves the right to discontinue products or change designs at any time without incurring any
obligation.

DYNEX High Pressure Hydraulics

Copyright © Dynex/Rivett Inc. Bulletin dynexpespvspecs-1204


MECHANICAL
PF3000 SERIES,
VARIABLE
10 DESIGN
PUMPS

EFFICIENT VARIABLE DELIVERY Pump Selection


Pump Type Maximum Flow Rated Intermittent
Checkball pump delivery is controlled by and Series at 1800 rpm Pressure Pressure
variable inlet ports in each piston pumping
chamber. In these mechanical variable
models, output is adjusted by the linear Mechanical Variable Pumps:
movement of a spring-biased volume 12.2 to 22.4 All Models All Models
control stem. PV4000 U.S. gpm 4000 psi 6000 psi
Series
Fluid not needed to meet system (46,2 to 84,8 L/min) (280 bar) (420 bar)
requirements returns to tank at low Mechanical Variable with Pressure Compensator:
pressure, typically 100 psi (7 bar). The
result is efficient pump control, providing 12.0 to 22.4 4000 or 6000 or
infinitely variable flow to the system. PV4000 U.S. gpm 8000 psi 8500 psi
Series
(45,4 to 84,8 L/min) (280 or 560 bar) (420 or 590 bar)
Pressure Compensated Models
Compensated pumps vary their output flow 31.1 to 61.4 All Models 6000 or
PV6000 U.S. gpm 6000 psi 8500 psi
to maintain a preset maximum pressure. Series
The integral compensator internally (117,7 to 232,4 L/min) (420 bar) (420 or 590 bar)
overrides the maximum volume control to
smoothly regulate delivery.

HOW OUTPUT IS CONTROLLED INLET


VARIABLE INLET PORT
POPPETS
WOBBLE PLATE OUTLET
Pump output is regulated by variable
inlet ports located between the inlet
and outlet check valves in each
piston pumping chamber. The angle
of the rotating wobble plate remains DRIVE STEM
constant during operation. SHAFT CONTROL
SUCTION

Isolated Fluid is Pressurized


The opening and closing of the
variable inlet ports, during each piston
stroke, determines the amount of
fluid isolated and pressurized in the DISCHARGE
chamber. Fluid not needed to meet
output requirements is diverted to
tank at low pressure.
In mechanical variable pumps, the
ECCENTRIC
variable inlet ports are opened and CAM SLEEVE HELIX CAM CAM SHAFT
closed by poppets, which move in
contact with an internal eccentric
cam shaft. This spring-loaded cam Linear movement of the volume or duration during which the
shaft rides inside a sleeve which stem control pushes the cam shaft variable inlet ports are open relative
rotates with the drive shaft. into the sleeve. As the stem moves, to each piston’s stroke.
a helix in the sleeve causes the cam Adjusting the volume stem control
Variable Ports Open and Close shaft to turn in the sleeve. affects the timing and the output of
As the drive shaft and cam rotate, all pistons in an identical manner.
the poppets move radially on the Stem Movement Changes Timing For example, as the stem is moved
cam. This causes the poppets to Turning the cam shaft changes in (on standard PV4000 Series
unseat and seat, once during each the position of maximum cam pumps), the duration is shortened
shaft revolution and piston stroke. eccentricity, changing the timing, and pump output increases.

2
PV4000 SERIES

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
PV4018-2928 10.1 38,2 12.2 46,2 4000 280 6000 420 2000 2400
PV4026-2929 14.7 55,6 17.6 66,6 4000 280 6000 420 2000 2400
PV4033-2117 18.7 70,8 22.4 84,8 4000 280 6000 420 1800 2100
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.

PUMP DESCRIPTION Minimum Inlet Pressures ➀


PV4000 Series checkball pumps supply Operating Speed
infinitely variable flow. Output is regulated 1200 rpm 1500 rpm 2100 rpm 2400 rpm
Pump
by mechanically controlled variable inlet Models psi bar psi bar psi bar psi bar
ports in each piston pumping chamber.
PV4018 and PV4026 0 0 5 0,4 5 0,4 10 0,7
Mechanical variable pumps are not bi- PV4033 0 0 5 0,4 5 0,4 – –
rotational; rotation must be specified, ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). Inlet pressures higher than 10 psig
viewed from the shaft end. (0,7 bar) require a high-pressure shaft seal.

Mounting
S.A.E. D 4-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.
PUMP SELECTION Fluid Guidelines
Shaft Options See page 15 for “Fluid Recommendations”.
Standard keyed shaft, 1.250 inch The “Specifications” table includes the
most commonly used standard models with Some pump models may require reduced
(31,75 mm) diameter; operating pressures when using low-
keyed shafts.
Optional spline shaft, 1.248/1.247 inch lubricity fluids.
diameter standard S.A.E. 14 tooth, Models listed are for clockwise rotation and
deliver zero flow with the volume stem Because of the wide range of fluid
12/24 D.P. 30° involute spline. characteristics, contact the sales
control in the “out”, fully-extended position.
Outlet Port Models are also available to deliver full flow department for a review of any application
Standard S.A.E. ports. See “Outlet Port with the stem extended. using non-petroleum based fluids.
Configurations” on page 16. Contact the sales department for models Split-Flow® Provides Multiple Outlets
with spline shafts, optional seals, counter-
Inlet Conditions clockwise rotation, different control PV4000 models with split-flow covers
Pumps may require pressurized inlet options and other extraordinary operating efficiently supply flows for multiple
conditions at higher speeds. Failure to meet requirements. function circuits. Piston outputs are grouped
together in the cover, with various piston
minimum inlet requirements will result in
slight flow reduction. Refer to the table. Maximum Pressure flow splits available in this ten-piston pump.
Checkball pumps are especially suited These pumps are also available with isolator
Seal Options for applications susceptible to excessive valves, to separate one or more pistons from
Standard seals are Buna-N (Nitrile). Options pressure spikes. the main outlet. Up to ten independent
include Fluorocarbon (Viton® or Fluorel®) The intermittent pressures listed are flows are possible from these ten-piston
or EPR for use with some phosphate ester the maximum pressures a pump can pumps.
fluids. sustain for occasional, short periods of Contact the sales department for Split-Flow®
Inlet pressures higher than 10 psig (0,7 bar) operation without appreciably reducing life options and availability.
require a high-pressure shaft seal. expectancy.
Weight (Mass)
125 lb (57 kg)

3
PV4000 SERIES

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to the “Minimum Inlet Pressure” table on page 3.

INSTALLATION
All dimensions are shown in inches Refer to Bulletin PSI.CB for
(millimeters in parentheses) and are general installation and operating
nominal. See page 3 for optional spline recommendations.
shaft data.

6.364 9.47
(161,65) (240,5)
3.182 4.06 INLET PORT OUTLET PORT VOLUME CONTROL STEM
(80,82) SQUARE KEY (103,1) NO. 24 S.A.E. NO. 12 S.A.E. .375-16 U.N.C.–2A THREADED
.31 x 1.18 1.00
(7,9 X 30,0) (25,4)

.63 4.62
(
1.392 35,36
1.384 35,15 ) (16,0) (117,3)

∅ 6.000
5.998

(152,40
152,35 )
∅ 1.250 (
31,75
1.248 31,70 )
∅ 3.25
(82,6)
∅ .812 (20,62)
4 MOUNTING .25
8.00 HOLES (6,4) BLEED PORTS (3) .94 (23,9) STROKE, .50
(203,2) .58 NO. 6 S.A.E., 90° APART FULL FLOW IN, (12,7)
(14,7) 1.75 ZERO FLOW OUT
.75 (44,4) BLEED PORT IN HOUSING
(19,0) FOR VERTICAL MOUNTING
2.25 10.72 1.66 MAXIMUM NO. 4 S.A.E.
(57,2) (272,3) (42,2)

4
PV4000 PRESSURE COMPENSATED

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
Pressure Compensated with Volume Stem Control:
PV4020-3046 9.8 37,1 12.0 45,4 8000➁ 560 8500➁ 590 1800 1800
PV4026-3126 14.7 55,6 17.6 66,6 4000 280 6000 420 1800 1800
PV4033-3127 18.7 70,8 22.4 84,8 4000 280 6000 420 1800 1800
Pressure Compensated with Electrohydraulic Control:
PV4020-3187 9.8 37,1 12.0 45,4 8000➁ 560 8500➁ 590 1800 1800
PV4026-3188 14.7 55,6 17.6 66,6 4000 280 6000 420 1800 1800
PUMP DESCRIPTION PV4033-3189 18.7 70,8 22.4 84,8 4000 280 6000 420 1800 1800
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
These high-pressure checkball pumps adjust shown in the table below.
their output flow to maintain a preset ➁ The pressure rating may be limited by the fitting used in the No. 12 S.A.E. outlet port. Contact the fitting
manufacturer for the pressure rating of the fitting.
maximum pressure.
The integral pressure compensator overrides
a maximum volume control to smoothly Minimum Inlet Pressures ➀
and quietly regulate delivery. Fast response Operating Speed
to load conditions assures full power in the
1200 rpm 1500 rpm 1800 rpm
system up to a pressure very close to the
compensator setting. Pump Models psi bar psi bar psi bar
All PV4000
These mechanically controlled pumps Pressure Compensated Models
0 0 5 0,4 5 0,4
are not bi-rotational; rotation must be
➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). Inlet pressures higher than 10 psig
specified, viewed from the shaft end. (0,7 bar) require a high-pressure shaft seal.

Electrohydraulic Remote Control


Electrohydraulic flow control can
be achieved using a Dynex Remote Seal Options Maximum Pressure
Proportional Actuator (RPA). The bracket-
Standard seals are Buna-N (Nitrile). Options Checkball pumps are especially suited
mounted actuator strokes the pump volume
include Fluorocarbon (Viton® or Fluorel®) or for applications susceptible to excessive
control stem. See page 7.
EPR for use with some phosphate ester fluids. pressure spikes.
For complete RPA specifications, refer to
Bulletin EES.RPA. Weight (Mass) The intermittent pressures listed are
the maximum pressures a pump can
Manual Control Models: sustain for occasional, short periods of
Mounting 140 lb (64 kg)
S.A.E. D 4-bolt pattern with 0.25 inch operation without appreciably reducing life
Electrohydraulic Control Models: expectancy.
(6,4 mm) pilot engagement.
156 lb (71 kg)
Shaft Fluid Guidelines
Standard keyed shaft, 1.250 inch PUMP SELECTION See page 15 for “Fluid Recommendations”.
(31,75 mm) diameter; The “Specifications” table includes the Some pump models may require reduced
most commonly used standard models with operating pressures when using low-
Outlet Port Options lubricity fluids.
keyed shafts.
Standard S.A.E. ports. See “Outlet Port Because of the wide range of fluid
Configurations” on page 16. Models listed are for clockwise rotation.
These compensated pumps deliver full flow characteristics, contact the sales
department for a review of any application
Inlet Conditions with the volume stem control in the “out”,
using non-petroleum based fluids.
Pumps may require pressurized inlet fully-extended position.
conditions at higher speeds. Failure to meet Contact the sales department for models
minimum inlet requirements will result in with optional seals, counter-clockwise
slight flow reduction. Refer to the table. rotation, different control options and other
extraordinary operating requirements.

5
PV4000 PRESSURE COMPENSATED

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to “Minimum Inlet Pressure” table on page 5.

6
PV4000 PRESSURE COMPENSATED

INSTALLATION Pump Inlet/Drain Port The RPA requires a separate pilot supply:
Note the location of the dual purpose Minimum, 200 psi (15 bar); Maximum,
All dimensions are shown in inches 3000 psi (210 bar). For complete RPA
inlet/drain port. Acting as an inlet, this port
(millimeters in parentheses) and are nominal. specifications, refer to Bulletin EES.RPA.
increases volumetric efficiency by improving
Refer to Bulletin PSI.CB for general installation the filling of the piston chamber.
and operating recommendations. Assembly of RPA and Bracket
Acting as a drain, the port diverts unused For ease of shipping, electrohydraulic
Volume and Pressure Control fluid at low pressure from the chamber, models are shipped as two sub-assemblies.
Compensated models deliver full flow with providing improved circulation which The RPA/bracket sub-assembly must be
the volume control stem extended out of dissipates heat. mounted to the rear of the pump using the
the pump. Electrohydraulic Pump Control tie rods and nuts provided with the pump.
Pressure is set by turning the adjustment Recommended torque is 40 lb•ft (54 N•m).
PV4000 Series pumps use a bracket-mounted
clockwise for increased pressure. One- Dynex Remote Proportional Actuator (RPA) to
quarter turn equals 1000 psi (70 bar). The stroke the pump volume control stem.
Electrohydraulic Control Kits
adjustment range is 1000 psi (70 bar) to the Pump Kit Number➀
Electrohydraulic capability can be added to
maximum pressure rating. Maximum PV4000 Series Pumps:
torque required to adjust the compensator a standard pump using an Electrohydraulic
Control Kit. Refer to the table. Pressure Compensated KP4020-9047
is 20 lb•in (2,3 N•m). Non-compensated KP4026-9047
➀ Kit includes a bracket and hardware. The
Dynex Remote Proportional Actuator must be
ordered separately.

INLET PORT – NO. 24 S.A.E. 9.47 INLET/DRAIN PORT GAGE PORTS (4) COMPENSATOR ADJUSTMENT
(240,5) NO. 10 S.A.E. NO. 6 S.A.E. .625 (15,88) HEX,
SQUARE KEY 6.87 MAXIMUM 20 LB•IN (2,3 N•M)
.31 x 1.18 (174,5) OUTLET PORT– NO. 12 S.A.E. REQUIRED
∅ 3.13
(7,9 X 30,0) 4.06 4.35
36/38° (110,5)
(79,5) (103,1) VOLUME
(
1.250 31,75
∅ 1.248 31,70 ) CONTROL STEM
.250-20 U.N.C.–2A
THREADED 4.62
(
1.392 35,36
1.384 35,15 ) (117,3) 52°
6.000
∅ 5.998

(152,40
152,35 ) 4°
.44 .24 1.50
(11,2) (6,1) (38,1)
.13
(3,3) .25 .94 (23,9) STROKE, .50
3.182 2.44 FULL FLOW OUT,
(6,4) (62,0) (12,7)
(80,82) .58 ZERO FLOW IN, .42
(14,7) 50 LB (220 N) (10,7)
6.364 .75 ∅ 8.00
(161,65) ∅ .812 (20,62) (19,0) (203,2)
3.88 2.38 MAXIMUM
4 MOUNTING 1.00 (98,6)
8.00 (60,5)
HOLES (25,4) BLEED PORT IN HOUSING
(203,2) 2.25 10.72 BLEED PORTS (3) – NO. 6 S.A.E., 90° APART FOR VERTICAL MOUNTING
(57,2) (272,3)
NO. 4 S.A.E.

Manual Volume Control Pressure Compensated Models

BRACKET MOUNTING,
MANUAL OVERRIDE STEM CONTROL TORQUE TO 4 LB•FT (54 N•M)
FULL FLOW OUT
ZERO FLOW IN 2.44
.24 (62,0)
DRAIN PORT
.250 N.P.T.F. (6,1)
1.62
.24 (41,1)
(6,1) 3.06
(77,7)

1.18
2.36 (30,0)
(59,9)
.42 10.50
(10,6) (266,7)
1.25 PILOT SUPPLY
1.24 13.00
(31,8) PRESSURE PORT
(31,5) (330,2)
.250 N.P.T.F.
3.58 200 PSI (15 BAR) MINIMUM 16.22 10.72 2.25
(90,9) (412,0) (272,3) (57,2)

Electrohydraulic Volume Control Pressure Compensated Models

7
PV6000 PRESSURE COMPENSATED

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
Pressure Compensated with Volume Stem Control:
PV6046-3177 25.9 98,1 31.1 117,7 6000 420 8500 590 1800 1800
PV6054-3183 30.5 115,5 36.7 138,9 6000 420 8500 590 1800 1800
PV6070-3502 40.0 151,4 48.0 181,7 6000 420 8500 590 1800 1800
PV6089-3498 51.2 193,8 61.4 232,4 6000 420 6000➁ 420➁ 1800 1800
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.
➁ For applications requiring intermittent operation above 6000 psi (420 bar), contact the sales department.
PUMP DESCRIPTION
These high-pressure checkball pumps adjust
their output flow to maintain a preset
maximum pressure. Minimum Inlet Pressures ➀
The integral pressure compensator overrides Operating Speed
a maximum volume control to smoothly 1200 rpm 1500 rpm 1800 rpm
and quietly regulate delivery. Fast response
Pump Models psi bar psi bar psi bar
to load conditions assures full power in the
system up to a pressure very close to the PV6046 and PV6054 0 0 3 0,2 5 0,4
compensator setting. PV6070 3 0,2 8 0,6 10 0,7
PV6089 5 0,4 10 0,7 15 1,0
These mechanically controlled pumps
are not bi-rotational; rotation must be ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). All PV6000 Series pumps have a high-
pressure shaft seal.
specified, viewed from the shaft end.
Electrohydraulic Remote Control
Electrohydraulic flow control can
be achieved using a Dynex Remote Outlet Port PUMP SELECTION
Proportional Actuator (RPA). The bracket- As shown, the standard S.A.E. No. 16 outlet
mounted actuator strokes the pump volume The “Specifications” table includes the
port on these pumps is machined in a block most commonly used standard models with
control stem. integrally mounted to the pump barrel. See spline shafts.
Electrohydraulic control is not available “Outlet Port Configurations” on page 16.
for PV6000 Series as an integral unit. Models listed are for clockwise rotation.
Refer to page 10 for information on the Inlet Conditions These compensated pumps deliver full flow
Electrohydraulic kit. with the volume stem control in the “out”,
Pumps may require pressurized inlet
fully-extended position.
For complete RPA specifications, refer to conditions at higher speeds. Failure to meet
Bulletin EES.RPA. minimum inlet requirements will result in Contact the sales department for models
slight flow reduction. Refer to the table. with optional seals, counter-clockwise
Mounting rotation, handwheel control option
S.A.E. E 4-bolt pattern with 0.25 inch
Seal Options and other extraordinary operating
(6,4 mm) pilot engagement. Standard seals are Fluorocarbon (Viton® or requirements.
Fluorel®). All PV6000 Series pumps have a
Standard Spline Shaft high-pressure shaft seal. Options include Fluid Guidelines
1.748/1.747 inch diameter standard EPR seals for use with some phosphate ester See page 15 for “Fluid Recommendations”.
13 tooth, 8/16 D.P. 30° involute spline. fluids. Some pump models may require reduced
operating pressures when using low-
Weight (Mass) lubricity fluids.
Models PV6046, PV6054 and PV6070:
Because of the wide range of fluid
345 lb (156 kg)
characteristics, contact the sales
Model PV6089: department for a review of any application
360 lb (163 kg) using non-petroleum based fluids.

8
PV6000 PRESSURE COMPENSATED

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized inlet
where required. Refer to “Minimum Inlet Pressure” table on page 8.

9
PV6000 PRESSURE COMPENSATED

INSTALLATION 1000 psi (70 bar) to the maximum pressure Electrohydraulic Remote Control
rating. Maximum torque required to adjust Electrohydraulic flow control can
All dimensions are shown in inches the compensator is 30 lb•in (3,4 N•m). be achieved using a Dynex Remote
(millimeters in parentheses) and are nominal.
Pump Inlet/Drain Port Proportional Actuator (RPA) to stroke the
Refer to Bulletin PSI.CB for general volume control stem.
installation and operating recommendations. Note the location of the dual purpose
inlet/drain port. Acting as an inlet, this port Electrohydraulic capability can be added
Volume and Pressure Control increases volumetric efficiency by improving using Kit KP6046-9047, which includes a
Compensated models deliver full flow with the filling of the piston chamber. bracket and hardware. The RPA must be
the volume control stem extended out of ordered separately.
Acting as a drain, the port diverts unused
the pump. fluid at low pressure from the chamber, The RPA requires a separate pilot supply:
Pressure is increased by turning the providing improved circulation which Minimum, 200 psi (15 bar); Maximum,
adjustment clockwise. One-quarter turn dissipates heat. 3000 psi (210 bar). For complete RPA
equals 1000 psi (70 bar), with a range from specifications, refer to Bulletin EES.RPA.

12.35 MODEL PV6089 COMPENSATOR ADJUSTING SCREW,


INLET PORT (313,6)
PATTERN FOR STANDARD .25 (6,4) INTERNAL HEX,
2-1/2 INCH S.A.E. 4-BOLT FLANGE 11.69 INLET/DRAIN PORT (2) — NO. 12 S.A.E. .75 (19,1) EXTERNAL HEX NUT,
(296,8) MAXIMUM 30 LB•IN (3,4 N•M)
3.04 3.82 OUTLET PORT — PATTERN FOR REQUIRED
(77,2) (97,0) STANDARD 1 INCH S.A.E. 4-BOLT FLANGE,
∅ 3.75 2.62
4.28 HIGH PRESSURE SERIES (CODE 62)
(95,2) 6.500 (108,7) 36° (66,5)
∅ 6.498 TYPICAL
VOLUME CONTROL STEM,
(
165,10
165,05) .250-20 U.N.C.–2A THREADED
2.4
2.06 (60,3)
5.81 .94 5.33
(52,3)
(147,6) (23,9) (135,3)

.97 (24,6) STROKE,


(
∅ 1.748 44,40
1.747 44,37 ) FULL FLOW OUT,
ZERO FLOW IN,
220 LB (980 N)
.13
4.419 (3,3) .25 3.80 2.82 MAXIMUM
(112,24) (6,4) (99,1) (71,6) ∅11.0
∅ .812 (20,62)
8.839 .94 (279,4)
4 MOUNTING (23,8)
(224,51) HOLES 4.41 BLEED PORTS (3)
10.62 NO. 8 S.A.E., 90° APART
(269,7) (112,0)
13.28
(337,3)
13.97 MODEL PV6089
(354,8)

10
HYDRAULIC VARIABLE PUMPS

EFFICIENT VARIABLE DELIVERY


Checkball pump delivery is controlled by
variable inlet ports in each piston pumping
chamber. In these hydraulic variable models,
output is regulated by a variable low-pressure
control signal, supplied to a control port in
the pump cover.
Fluid not needed to meet system requirements
returns to tank at low pressure, typically 100
psi (7 bar). The result is efficient pump control,
providing infinitely variable flow to the system.
Pump Volume Controls
Pump volume controls for PV6000 Series
pumps, including a remote pressure
compensator, improve the control and
design flexibility of hydraulic circuits.
Typical Motor Circuit
A typical open loop circuit uses a combination from the “CP” port decreases, which is sensed directional valve controlling the motor. This
volume/direction control valve to regulate at the pump control port “CP”. This results in pilot supply hydraulically controls actuator
the control signal. As the valve lever is moved an increase in pump output. Simultaneously, direction, providing an over-center function
to either side of center, the output pressure flow from the “A” or “B” port travels to the at the motor.

INLET
HOW OUTPUT IS CONTROLLED INLET CHECKBALL OUTLET 1
OUTLET
CHECKBALL
Pump output is regulated by variable
inlet port checkballs in parallel
with the outlet check valves of each CONTROL
PORT 1
piston pumping chamber. DRIVE
SHAFT
Pressure Signal Controls Output
These variable inlet checkballs are CONTROL
opened and closed by a variable PORT 2
control signal, 0 to 180 psi (0 to
12 bar), externally supplied to the
control port in the pump cover.
When full flow is not required,
the control signal unseats the
SPLIT-FLOW
variable inlet checkball at the start COVER
of the piston stroke. As the piston DESIGN
accelerates, the resulting flow VARIABLE INLET PORT
CHECKBALLS OUTLET 2
forces across the checkball increase
until the signal is overcome and the
checkball seats. combined in the barrel and Multiple Outlet Pumps
discharged from the pump outlet. Split-Flow® pumps supply two
Remaining Fluid is Pressurized Increasing the control signal, for independent flows to the circuit. The
The fluid remaining in the pumping example, increases the duration ten-piston pump provides five-piston
chamber then rises to system during which the variable inlet port output from each outlet port, regulated
pressure. The outlet checkball checkballs are unseated and by the variable pressure signal supplied
then unseats. Piston outputs are decreases pump output. to its corresponding control port.

11
PV6000 HYDRAULIC VARIABLE

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure➁ Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
Standard S.A.E. 4-Bolt Flange Outlet Port:
PV6054-3065 29.5 111,6 35.4 134,0 6000 420 6000 420 1800 2400
PV6070-3066 39.6 150,1 47.6 180,1 6000 420 6000 420 1800 2300
PV6080-2923 45.0 170,3 54.0 204,4 5500 380 5500 380 1800 2200
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
shown in the table below.
➁ Contact the sales department for applications requiring higher intermittent operating pressures.

PUMP DESCRIPTION
PV6000 Series checkball pumps supply Minimum Inlet Pressure ➀
infinitely variable flow. Output is regulated
by an external low-pressure control signal Operating Speed
supplied to a control port in the cover. Pump
1200 rpm 1500 rpm 1800 rpm 2400 rpm

These pumps, with bi-directional shaft Models psi bar psi bar psi bar psi bar
rotation, provide constant direction of PV6054 0 0 5 0,4 5 0,4 10 0,7
output flow regardless of the direction of PV6070 0 0 5 0,4 10 0,7 10➁ 0,7➁
drive shaft rotation. PV6080 5 0,4 5 0,4 10 0,7 15➁ 1,0➁
➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). All PV6000 Series pumps have a high-
Mounting pressure shaft seal.
➁ Refer to maximum speeds indicated in the “Specifications” table.
S.A.E. E 4-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.
Standard Spline Shaft
1.748/1.747 inch diameter standard S.A.E. PUMP SELECTION Split-Flow® Provides Multiple Outlets
13 tooth, 8/16 D.P. 30° involute spline. PV6000 Series models with split-flow
The “Specifications” table lists the most
commonly used standard models with covers efficiently supply flows for multiple
Outlet Port Options function circuits. Piston outputs are
Pattern for standard 1 inch S.A.E. 4-bolt standard spline shafts and high-pressure
shaft seals. grouped together in the cover, with this ten-
flange. Refer to “Outlet Port Configurations” piston pump providing five-piston output
on page 16. Contact the sales department for model from each of two independent ports. See
numbers with optional seals and other “Split-Flow® Output” on page 14.
Inlet Conditions extraordinary operating requirements.
Pumps may require pressurized inlet Tandem Pump Models
conditions at higher speeds. Failure to meet Regulating Pump Output PV6000 Series pumps with thru-shaft
minimum inlet requirements will result in Pump volume controls, including remote configuration simplify circuits by eliminat-
slight flow reduction. Refer to the table. pressure compensators, improve the ing separate dedicated pumps and drives,
flexibility of hydraulic circuits. Refer to and reducing piping and installation time.
Seal Options “Typical Open Loop Circuit” on page 11 and
contact the sales department for ordering A tandem mounted pump is ideal for
Standard seals are Buna-N (Nitrile). Options supplying auxiliary functions. Separate
include Fluorocarbon (Viton® or Fluorel®) information.
flows to multiple functions in a circuit
or EPR for use with some phosphate ester can be supplied by one unit, driven by a
fluids. Fluid Guidelines
See page 15 for “Fluid Recommendations”. common drive shaft.
Weight (Mass) Some pump models may require reduced
330 lb (150 kg) operating pressures when using low-
lubricity fluids.
Because of the wide range of fluid
characteristics, contact the sales department
for a review of any application using non-
petroleum based fluids.

12
PV6000 HYDRAULIC VARIABLE

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil
with pressurized inlet where required. Refer to the “Minimum Inlet Pressure” table on page 12.

INSTALLATION
All dimensions are shown in inches
(millimeters in parentheses) and are
nominal. Refer to Bulletin PSI.CB for general
installation and operating recommendations.

INLET PORT — PATTERN FOR STANDARD 11.94 MODEL


2-1/2 INCH S.A.E. 4-BOLT FLANGE (CODE 61) (303,3) PV6080 OUTLET PORT — PATTERN FOR STANDARD
11.54 1 INCH S.A.E. 4-BOLT FLANGE (CODE 62)
∅ 3.75 (293,0)
(95,2) 2.93 4.28 CONTROL PORT — NO. 6 S.A.E.
5.31
(74,5) (108,7) (134,9)

2.00
(50,8) 5.81
(147,6)
6.500
6.498 7.50
( 165,10
165,05 ) (190,5)
1.75
1.748
1.747 ( 44,40
44,37 )
(44,4)

.13
4.419 (3,3) .25
(112,24) (6,4) BLEED PORTS (3) INLET/DRAIN PORT
∅ .812 (20,62) .94 NO. 8 S.A.E., 90º APART NO. 16 S.A.E.
8.839 4 MOUNTING
(224,51) (23,9) 4.41
HOLES ∅ 10.88
(112,0) 15.18
10.62 (276,4)
(385,6)
(269,7)
15.59 MODEL
(396,0) PV6080

PV6000 Series Standard Full-Flow Configuration

13
PV6000 HYDRAULIC VARIABLE

Pump Inlet/Drain Port


THREE OUTPUT FLOWS TO ACTUATORS FOUR OUTPUT FLOWS TO ACTUATORS
Note the location of the dual purpose
inlet/drain port. Acting as an inlet, this port
increases volumetric efficiency by improving PRIME
MOVER
P1 P2 PRIME
MOVER
P1 P2 P3 P4

the filling of the piston chamber.


Acting as a drain, the port diverts unused M M
fluid at low pressure from the chamber, PV6
CP2
PV6
CP2
AUXILIARY
PF2
providing improved circulation which SPLIT-FLOW ®
PUMP
CP1 AUXILIARY
PUMP
SPLIT-FLOW ®
PUMP
CP1 SPLIT-FLOW®
PUMP

dissipates heat.
Split-Flow® Output
PV6 PUMP VOLUME PV6 PUMP VOLUME
As shown in the circuit, the Split-Flow® CONTROL SIGNALS
0 TO 180 PSI (0 TO 12 BAR)
CONTROL SIGNALS
0 TO 180 PSI (0 TO 12 BAR)

PV6000 Series pump can supply two variable


flows, or one fixed and one variable flow. This 10-piston Split-Flow® pump provides With a two-outlet Split-Flow ® PF2000
Each output (P1 and P2) is independently two 5-piston outputs, plus a third flow Series pump as an accessory pump, one
delivered from a tandem mounted auxiliary unit provides four separate flows driven by
controlled by its own external control pump. a single drive-shaft.
pressure signal (CP1 and CP2). See “How
Output is Controlled” on page 11.
Tandem Pump Mounting The tandem pump can determine the rotation The installation drawing shows a Split-Flow®
Any accessory pump with a standard S.A.E. of both pumps, because shaft rotation of the pump with two independent variable
B 2-bolt or 4-bolt pattern can be tandem PV6000 Series is bi-directional, providing delivery outlet ports (5 pistons output + 5
mounted on the PV6000 Series Thru-Shaft constant direction of output flow regardless pistons output).
pump. The internal coupling is a standard of drive shaft rotation. For complete model numbers and a review
S.A.E. B spline. Refer to the installation drawing and the of the application, contact the sales
circuit drawings above. department.

15.28 PATTERN FOR STANDARD


(388.1) S.A.E. B 4-BOLT MOUNTING
INLET PORT — PATTERN FOR 12.16 3.536
STANDARD 2-1/2 INCH (308,9) (89,81)
S.A.E. 4-BOLT FLANGE (CODE 61) 11.31 OUTLET PORTS (2) 1.768
(287,3) NO. 16 S.A.E. (44,91)
.500-13 U.N.C. – 2B THREADED
2.93 4.28 CONTROL PORTS (2)
INLET/DRAIN PORT 6 MOUNTING HOLES, .81 (20,6) DEEP 5°
(74,5) (108,7) NO. 6 S.A.E.
NO. 16 S.A.E.

2.00
(50,8) P2
4.004
4.002 ( 101.70
101.65 )

CP1 30 °
AUXILIARY PUMP 18°
7.50
TANDEM MOUNTED (190,5)
P1 (PV2000 SERIES SHOWN) 18° 15°
CP2
1.748
1.747 ( 44,40
44,37 )

.13
(3,3) INTERNAL S.A.E. B 2.875
.25 SPLINE MOUNTING (73,02)
(6,4) BLEED PORTS (3) 5.750
.94 NO. 8 S.A.E. (146,05)
(23,9) 90° APART
4.41 PATTERN FOR STANDARD
(112,0) S.A.E. B 2-BOLT MOUNTING
13.94 2.34
(354,1) (59,4)

PV6000 Series Split-Flow® Thru-Shaft Configuration

14
FLUID GUIDELINES

FLUID RECOMMENDATIONS Hydraulic Fluid Viscosity➀


Mineral Oil Operating
Minimum Maximum Start-up➁ Optimum
A high-grade premium petroleum-based Pump
fluid should be used to assure long Models SUS cSt SUS cSt SUS cSt SUS cSt
component and system life. The fluid Fixed Displacement Pumps:
should have a combination of anti-wear, PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70
demulsibility, rust protection, oxidation- PF1000-10 59 10 1911 413 3706 800 98 to 324 20 to 70
resistant and foam-resistant properties.
PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70
Special Fluids PF2000➁ 34 2,3 1911 413 1911 413 98 to 324 20 to 70
Various pump models are available for use PF3000-10 59 10 1911 413 3706 800 98 to 342 20 to 70
with water-based fluids, diesel calibration PF4000-30 34 2,3 1911 413 1911 413 98 to 324 20 to 70
fluids, phosphate ester fluids, machining PF4200-10 34 2,3 1911 413 1911 413 98 to 324 20 to 70
coolant, brake fluid, various military fluids PF4300-11 31 1,5 927 200 927 200 – –
and other special fluids.
PF6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
PF4300 Series pumps are compatible with Mechanical Variable Delivery Pumps:
a variety of water-based fluids. These
PV4000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
models, which are specifically rated for use
with low-lubricity fluids. PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
Hydraulic Variable Delivery Pumps:
Some pump models may require reduced
operating pressures when using low- PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
lubricity fluids. ➀ Fluid conditions outside the “Optimum” range may result in reduced output, requiring pressurized inlet
conditions. Contact the sales department.
Because of the wide range of fluid ➁ Models with special mounting.
characteristics, contact the sales
department for a review of any application
using non-petroleum based fluids.
Viscosity Specifications MINIMUM FILTRATION LEVELS INSTALLATION AND OPERATION
Using fluid with the correct viscosity range Pump inlet: 150 µ nominal; Refer to separate Bulletin PSI.CB for
is critical to achieving long component life. general installation and operating
Pressure or return line: 25 µ nominal.
Fluid conditions outside the “Optimum” recommendations.
range shown in the table may result in While finer filtration levels than these
are desirable and will result in longer That brochure includes information on
reduced pump output, requiring pressurized mounting, shaft loading, sizing inlet pipe
inlet conditions. For more information, component life, restricting flow to the
pump inlet should be avoided. Minimum and hose, air bleed procedures and initial
contact the sales department. start-up. Guidelines for maintenance, repair
recommended inlet conditions must be
maintained. and trouble-shooting are also included.
If a system component fails resulting in fluid
contamination, it is important to drain and
clean the reservoir, all lines, filter screens
and all components. Refill with new fluid.

15
OUTLET PORT CONFIGURATIONS

PORT DESCRIPTIONS Coned and Threaded Ports The recommended fitting has a recessed
seal cavity formed by a shoulder on the
Dynex pumps are available with outlet ports underside of the flanged wrench flat (Voss
suitable for use at various pressure ranges. TUBING GLAND NUT
“Peflex”, Form B Shoulder Seal; or Parker
Refer to the appropriate “Specification Type E, “EOlastic” Seal; or equivalent).
Table” or “Typical Model Code” to specify
the required port. B.S.P. ports are not recommended for
operation above 10 000 psi (700 bar).
Contact the fitting manufacturer to ensure SLEEVE Contact the fitting manufacturer, to ensure
the selected fittings are rated for the PUMP
WEEP the selected fittings are rated for the
maximum pump operating pressure. COVER
HOLE
maximum pump operating pressure.

S.A.E. Straight Thread Ports Typical Coned and Threaded


port connection S.A.E. 4-Bolt Flange Ports
High-pressure pumps are available with
COUPLING coned and threaded outlet ports, which use FLANGE
Autoclave Medium Pressure, Butech M/P, or BOLTS

equivalent fittings.
These fittings provide a metal-to-metal seal O-RING
O-RING
with an interference fit, not requiring an
PUMP o-ring. The gland nut holds the sleeve and
COVER
tubing against the cone surface. PUMP
COVER
A weep hole, visible on the outside of
Typical S.A.E. Straight Thread the pump cover, acts as an indicator of Typical S.A.E. 4-Bolt Flange
port connection port connection
any abnormal leakage caused by system
The Straight Thread connection (S.A.E. conditions (i.e., excessive pressure). It allows Flange connections are often used for
J1926/1) is sometimes referred to as an any fluid which does leak past the sealing higher flows requiring larger diameter
S.A.E. O-ring Boss, or ORB. The port consists surfaces to escape, preventing pressure tubing. The port consists of an unthreaded
of a machined spotface surface, a tapered build-up and possible damage. port with four bolt holes in a rectangular
seal cavity and a straight thread port. pattern on a machined face around the port
The fitting forms a seal by compressing the British Standard Pipe Ports (S.A.E. J518).
o-ring in the seal cavity with the underside A typical fitting consists of a flanged head
of the flanged wrench flat. Some adjustable with a welded tube and a captive flange
fittings, such as elbows and tees, use a COUPLING
with bolt holes. A seal is formed by an
locknut with a captive backup washer for o-ring in the groove on the underside
compression. SEAL RING
mounting surface of the flange head. As the
S.A.E. Straight Thread ports are not flange bolts are alternately tightened, the
recommended for operation above SHOULDER o-ring is compressed between the flange
8000 psi (560 bar). Also, the maximum head and the machined face on the pump.
PUMP
pressure of pumps with No. 12 S.A.E. outlet COVER To make mounting easier in tight spaces a
ports may be limited by the pressure rating two-piece split-flange is often used.
of the available fitting. Contact the fitting
Typical port connection with
manufacturer for ratings. British Standard Pipe (Parallel)
fitting with shoulder

High-pressure pumps are available with flat


face ports with British Standard Pipe (B.S.P.)
parallel threads (BS 2779 or ISO 228), ideal
for use on some European applications.
The fitting forms a seal by compressing a
flat elastomer ring on a machined spotface
surface. There are several sealing methods
for these ports.

16
SPECIFICATIONS

Pump and Motor


Mounting
Bracket Kits
Also refer to "Pump Features, Selection and Operating
Recommendations" (dynexpumpoperating.pdf)

CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: sales@dynexhydraulics.com

Power Units & Systems


Dynex/Rivett Inc.
54 Nickerson Road
Ashland, MA 01721 U.S.A.
Tel: 508-881-5110
FAX: 508-881-6849
E-mail: ashland@dynexhydraulics.com

European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: sales@dynexhydraulics.co.uk

For more information


visit our web site:
www.dynexhydraulics.com

BROCHURE NOTES:
Maximum pressures indicated throughout are the maximum intermittent pressures a component can
sustain for occasional, short periods of operation without appreciably reducing the life expectancy.
Contact the Dynex sales department for a review of any application which requires operating above
the rated pressures, flows, speeds or higher than normal operating temperatures.
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative for the most current specifications before ordering. Dynex reserves the right
to discontinue products or change designs at any time without incurring any obligation.

DYNEX High Pressure Hydraulics

Copyright © Dynex/Rivett Inc. Bulletin dynexpesbracketspecs.pdf-0901


BRACKET KITS

Pump and Motor 3.256


3.252 ( 82,70
82,60 )
.38
(9,7)

Mounting Bracket Kits 2.13


(54,10)
4.25 .375-16 U.N.C. – 2B THREADED
(107,95) 7.00 MTG. HOLES (4)
(177,8)
TOP VIEW
Mounting brackets are available in (REDUCED SCALE) 3.75 .41 (10,4) MTG. HOLES (4)
kits, which include mounting bolts (95,25)

and lock washers. Bolts can also be 4.188 (106,38) B.C.


1.13 2.13
ordered separately. 2.50 2.50 (28,7) (54,1) .38
(63,5) (63,5) (9,7)
4.00
The table below also lists RPA 6.50 (101,6)
(165,1) KP1000-9060
mounting bracket kits for converting
PV4000 and PV6000 Series check-
ball pumps for electro-hydraulic
control.
2.474
2.470 ( 62,84
62,74 ) .75 (19,0) — 4 PADS

45
.500-13 U.N.C. – 2B THREADED
MTG. HOLES (4)
6.88
(174,8)
3.94 .53 (13,5) MTG. HOLES (4)
KIT SELECTION TABLE (100,1)
6.188 (157,18) B.C.
Pump/Motor Kit Number
Weight 2.81 2.81 2.63 3.00
Series (Mounting) (71,4) (71,4) (66,8) (76,2) .63
6.63 (16,0)
7.88
PF1000 KP1000-9060 6 lb (2,7 kg)
(200,2) (168,4)
KP2000-9060
(S.A.E. A 2-Bolt)
PF2006 KP2000-9060 16 lb (7,3 kg)
PF2008 (Modified)
PF2000 4.006
( 101,75
101,65 ) .75 (19,0) — 4 PADS
KP2012-9060 4.002
PV2024 (S.A.E. B 2-Bolt) 16 lb (7,3 kg)
MV2000 .500-13 U.N.C. – 2B THREADED
MTG. HOLES (4)
PF3000 KP3021-9060 16 lb (7,3 kg) 8.00
MF2000 (S.A.E. C 4-Bolt) (203,2)
4.50 .53 (13,5) MTG. HOLES (4)
PF4000 KP4000-9060 5.750 (146,05) B.C. (114,3)
29 lb (13,2 kg)
PV4000 (S.A.E. D 4-Bolt)
2.81 2.81 2.63 3.00
KP4020-9047➀ (71,4) (71,4) (66,8) (76,2) .63
6.63 (16,0)
7.88
PV4000 (RPA Bracket for 7 lb (3,2 kg) (200,2) (168,4)
Compensated Pump) KP2012-9060
KP4026-9047➀
(RPA Bracket for
PV4000 6 lb (2,7 kg)
Non-compensated
5.006
Pump) 5.002 ( 127,15
127,05 ) .75 (19,0) — 4 PADS

KP6046-9047➀
45 .500-13 U.N.C. – 2B THREADED
PV6000 (RPA Bracket for 8 lb (3,6 kg) MTG. HOLES (4)
Compensated Pump) 7.50
(190,5)
➀ For installation information, refer to Bulletin: 6.375 (161,92) B.C.
4.50 .53 (13,5) MTG. HOLES (4)
(114,3)
dynexpespvspecs.pdf. RPA must be ordered
separately.
2.81 2.81 2.63 3.00
(71,4) (71,4) (66,8) (76,2) .63
6.63 (16,0)
7.88
(200,2) (168,4)
KP3021-9060

6.006
6.002 ( 152,55
152,45 ) .81 (20,6) — 4 PADS

45 .750-10 U.N.C. – 2B THREADED


MTG. HOLES (4)
9.56
(242,8)
5.50 .81 (20,6) MTG. HOLES (4)
9.000 (228,60) B.C. (139,7)

3.50 3.50 1.00 8.00


(88,9) (88,9) (25,4) (203,2) .75
10.25 (19,0)
9.50
(241,3) (260,4)
KP4000-9060
2
SPECIFICATIONS

Split-Flow
Pumps

DYNEX
High Pressure Hydraulics
GENERAL INFORMATION

Hydraulic Products
Used With Confidence
Throughout the World

Dynex manufactures hydraulic components and systems which operate under


difficult conditions including high pressure, contamination, dirty environments,
fluids with low lubricity, extreme temperature variations and long duty cycles.
High flow piston pumps and control valves operate with extended life at
pressures from 6000 to 20 000 psi (420 to 1380 bar).
The company’s history dates to 1884. The two divisions, Dynex and Rivett, were
incorporated as Dynex/Rivett Inc. in 1977. Today, customers use high-performance
Dynex products for stronger, more efficient and reliable designs — for machines
that can be used with confidence around the world.
We are committed to responding to customers’ special requirements. Our flexible
product design and manufacturing can shorten new-product development time,
as well as support regular production needs.

BROCHURE NOTES:
Maximum pressures indicated throughout are the maximum intermittent pressures a component can
sustain for occasional, short periods of operation without appreciably reducing the life expectancy.
Contact the Dynex sales department for a review of any application which requires operating above
For more information the rated pressures, flows, speeds or higher than normal operating temperatures.
visit our web site: Specifications shown were in effect when published. Since errors or omissions are possible, contact
www.dynexhydraulics.com your sales representative for the most current specifications before ordering. Dynex reserves the
right to discontinue products or change designs at any time without incurring any obligation.

USA Headquarters Power Units & Systems European Sales


Dynex/Rivett Inc. Dynex/Rivett Inc. Dynex/Rivett Inc.
770 Capitol Drive 54 Nickerson Road Unit C5 Steel Close, Little End Road,
Pewaukee, WI 53072 Ashland, MA 01721 Eaton Socon, Huntingdon,
Tel: 262-691-2222 Tel: 508-881-5110 Cambs. PE19 8TT United Kingdom
FAX: 262-691-0312 FAX: 508-881-6849 Tel: +44 (0) 1480 213980
E-mail: E-mail: FAX: +44 (0) 1480 405662
sales@dynexhydraulics.com ashland@dynexhydraulics.com E-mail: sales@dynexhydraulics.co.uk

Copyright © Dynex/Rivett Inc. Printed in U.S.A. Bulletin dynexpessplitspecs-0901


SPLIT-FLOW CHECKBALL PUMPS

Split-Flow ® Pumps
Provide Flexibility to
Simplify Circuits

ISOLATED PUMPING CHAMBERS


The unique Split-Flow ® checkball
design isolates the pumping
chambers, allowing the output of
each piston to be used separately. 500 PSI 10,000 PSI

Individual outputs are grouped 8 GPM 2 GPM OUTLET A OUTLET B


together in the pump cover or barrel,
providing smooth, multiple flows to
meet system requirements. SPLIT-FLOW
CHECKBALL PUMP
SPLIT-FLOW
CHECKBALL PUMP

TYPICAL HI-LO CIRCUIT TYPICAL 2-FUNCTION CIRCUIT

A B A B A B A B

P T P T P T P T

All pistons can be isolated, supplying


up to ten independent flows, for
example, from a ten piston pump.

TYPICAL CIRCUITS SPLIT-FLOW


CHECKBALL
Multiple Function Systems PUMP

One pump can simultaneously


FOUR OUTLET 8 PISTON PUMP PROVIDES SYNCHRONIZED CYLINDER MOVEMENT
supply independent flows to multiple
functions in a circuit with separate
loads.
These pumps can reduce system
costs by supplying independent, The higher output flow, 8 U.S. gpm have flow variations in the secondary
fixed or variable flows to multiple (30 L/min), is then unloaded to tank. branches, especially when cascaded
functions in a system. A single pump The remaining 2 U.S. gpm (8 L/min) in series circuits.
can eliminate separate dedicated is supplied at high pressure up to the Hydrostatic Drive Circuits
pumps or mechanical gear boxes. relief valve setting of 10 000 psi
A typical open-loop circuit uses a ten
(700 bar).
The result is a simplified circuit, with piston PV6000 hydraulic variable
fewer components and less piping. Synchronous Movement pump with two outlets. Each five
Hi-Lo Circuit Split-Flow ® pumps can be used for piston pump output supplies
synchronous movement of cylinders independent variable flow to a motor.
Split-Flow ® pumps can efficiently
and motors without using flow Dynex DP Series valves in the circuit
supply flow in a circuit with changing
dividers. They provide unique control the low pressure signals
flow and pressure requirements.
advantages for lifting, jacking and which regulate the independent
These pumps are ideal for clamping, skidding operations, increasing the
pressing and high torque tool pump outputs. As a result, the speed
flexibility of systems for handling of each motor is controlled by its own
applications. Combined flow from both heavy loads.
pump outlets is supplied to the variable supply.
The pumps provide greater accuracy Refer to dynexpespvspecs.pdf for
actuator, until load pressure rises to
than flow dividers which operate over information on PV6000 hydraulic
the unloading valve setting, for
a narrow band width and are likely to variable pumps and volume controls.
example, 500 psi (35 bar).

3
SPLIT-FLOW PUMP SELECTION

Selecting Split-Flow ®
Pump Models INLET PORT INLET CHECKBALL

OUTLET CHECKBALL

ISOLATOR
OUTLET PORT
ISOLATOR VALVE MODELS
The checkball design, with its
isolated pumping chambers, allows ISOLATOR
the output of each piston to be used VALVE

separately.
MAIN OUTLET PORT
One or more individual pistons can be
isolated from the main outlet. Up to
ten separate outlet flows are possible,
for example, from a 10 piston pump.
Note that high pressure pump models
MODEL PF2006 WITH ISOLATOR VALVE
are limited to a maximum pressure of
6000 psi (420 bar) when using isolator
valves.
The table below lists pump series
available with isolators valves. INLET
INLET PORT CHECKBALL OUTLET PORT 1

SPLIT-FLOW-COVER MODELS
In split-flow-cover models, the
individual outputs are grouped
together in the pump cover or barrel
providing smooth, multiple outlet
flows. Select from various piston flow OUTLET
CHECKBALL
splits to match requirements.
For example, an eight piston PF3000
Series pump is available as a 4+4
split. The output of the four even
numbered pistons (2 through 8) is
combined separately from that of the
four odd numbered pistons (1 through OUTLET PORT 2

7). Individual portions of a circuit are


supplied by the output from each
PF1000 SERIES WITH SPLIT-FLOW-COVER
group of four pistons.
Other splits available for this pump
include a 5+3 split, a 6+2 split or a
7+1 split, as well as an eight-way
ISOLATOR VALVE MODELS
(8x1) split with separate outputs from
each of the eight pistons. Rated Flow Per Piston ➁ Isolator
On PV6000 Series hydraulic variable Number Valve
Pump
of 1200 rpm 1800 rpm Port Size
pumps, each output can be indepen- Series➀ Model
Pistons Number➃
dently controlled. Two control U.S. gpm L/min U.S. gpm L/min
pressure signals are directed to the
PF2006➂ 6 0.45 1,70 0.67 2,54 VC2006-1872 1/8 N.P.T.F.
rear pump cover to independently PF2008➂ 6 0.64 2,42 0.97 3,67 VC2008-1256 1/4 N.P.T.F.
control the variable deliver y
mechanism of each variable output. PF4011 10 0.50 1,89 0.75 2,84 VC4015-1845 S.A.E. No. 4
PF4015 10 0.70 2,65 1.05 3,97 VC4015-1845 S.A.E. No. 4
The table on page 5 lists the most PF4021 10 1.00 3,78 1.50 5,68 VC4015-1844 S.A.E. No. 4
common split-flow-cover models.
PF4018, PV4018 10 0.85 3,22 1.27 4,81 VC6046-1755 S.A.E. No. 6
PF4026, PV4026 10 1.21 4,58 1.81 6,85 VC6046-1755 S.A.E. No. 6
PF4033, PV4033 10 1.48 5,60 2.22 8,40 VC6046-1755 S.A.E. No. 6
PF6033 10 1.61 6,09 2.42 9,16 VC6033-1756 S.A.E. No. 6
PF6046 10 2.13 8,06 3.20 12,11 VC6046-3205 S.A.E. No. 8
➀ Contact your sales representative for complete model numbers and a review of your application.
➁ Output flow based on typical performance at rated pressure with pressurized inlet where required.
➂ These models are special mounting.
➃ Note that high pressure pump models are limited to a maximum pressure of 6000 psi (420 bar) when
using isolator valves.

4
SPLIT-FLOW SELECTION

SPLIT-FLOW-COVER MODELS
Rated Flow per Outlet➁
Number At 1200 rpm At 1800 rpm
Pump Number of Pistons per Outlet
of
Series➀ (Port Size) Outlet 1 Outlet 2 Outlet 1 Outlet 2
Pistons
Outlet 1 Outlet 2 U.S. gpm L/min U.S. gpm L/min U.S. gpm L/min U.S. gpm L/min
PF1002 4 0.47 1,78 0.47 1,78 0.70 2,65 0.70 2,65
PF1003 4 2 Pistons 2 Pistons 0.70 2,65 0.70 2,65 1.05 3,97 1.05 3,97
+
PF1004 4 (S.A.E. No. 4) (S.A.E. No.4) 0.85 3,22 0.85 3,22 1.28 4,84 1.28 4,84
PF1006 4 1.20 4,54 1.20 4,54 1.80 6,81 1.80 6,81
PF1002 4 0.70 2,65 0.23 0,87 1.05 3,97 0.35 1,32
PF1003 4 3 Pistons 1 Piston 1.05 3,97 0.35 1,32 1.58 5,98 0.52 1,97
+
PF1004 4 (S.A.E. No. 8) (S.A.E. No.4) 1.28 4,84 0.43 1,63 1.92 7,27 0.64 2,42
PF1006 4 1.80 6,81 0.60 2,27 2.70 10,22 0.90 3,41
PF2007 6 1.37 5,19 1.37 5,19 2.05 7,76 2.05 7,76
PF2008 6 3 Pistons 3 Pistons 1.93 7,31 1.93 7,31 2.90 10,98 2.90 10,98
+
PF2009 6 (S.A.E. No. 8) (S.A.E. No.8) 1.93 7,31 1.93 7,31 2.90 10,98 2.90 10,98
PF2012 6 2.83 10,71 2.83 10,71 4.25 16,09 4.25 16,09
PF2007 6 1.82 6,89 0.91 3,44 2.73 10,33 1.37 5,19
PF2008 6 4 Pistons 2 Pistons 2.58 9,77 1.29 4,88 3.87 14,65 1.93 7,31
+
PF2009 6 (S.A.E. No. 6) (S.A.E. No.6) 2.58 9,77 1.29 4,88 3.87 14,65 1.93 7,31
PF2012 6 3.78 14,31 1.89 7,15 5.67 21,46 2.83 10,71
PF2007 6 2.28 8,63 0.46 1,74 3.42 12,94 0.68 2,57
PF2008 6 5 Pistons 1 Piston 3.22 12,19 0.64 2,42 4.83 18,28 0.97 3,67
+
PF2009 6 (S.A.E. No. 8) (S.A.E. No.4) 3.22 12,19 0.64 2,42 4.83 18,28 0.97 3,67
PF2012 6 4.72 17,87 0.94 3,56 7.08 26,80 1.42 5,37
PF3011 8 2.75 10,41 2.75 10,41 4.15 15,71 4.15 15,71
PF3015 8 4 Pistons 4 Pistons 3.27 12,38 3.27 12,38 4.90 18,55 4.90 18,55
+
PF3017 8 (S.A.E. No. 8) (S.A.E. No.8) 3.90 14,76 3.90 14,76 5.85 22,14 5.85 22,14
PF3021 8 4.90 18,55 4.90 18,55 7.35 27,82 7.35 27,82
PF3011 8 3.46 13,10 2.08 7,87 5.19 19,64 3.11 11,77
PF3015 8 5 Pistons 3 Pistons 4.08 15,44 2.45 9,27 6.12 23,16 3.68 13,93
+
PF3017 8 (S.A.E. No. 12) (S.A.E. No.8) 4.88 18,47 2.92 11,05 7.31 27,67 4.39 16,62
PF3021 8 6.12 23,16 3.68 13,93 9.19 34,78 5.51 20,86
PF3011 8 4.15 15,71 1.38 5,22 6.22 23,54 2.08 7,87
PF3015 8 6 Pistons 2 Pistons 4.90 18,55 1.63 6,17 7.35 27,82 2.45 9,27
+
PF3017 8 (S.A.E. No. 12) (S.A.E. No.6) 5.85 22,14 1.95 7,38 8.78 33,23 2.92 11,05
PF3021 8 7.35 27,82 2.45 9,27 11.02 41,71 3.68 13,93
PF3011 8 4.84 18,32 0.69 2,61 7.26 27,48 1.04 3,94
PF3015 8 7 Pistons 1 Piston 5.72 21,65 0.82 3,10 8.58 32,48 1.22 4,62
+
PF3017 8 (S.A.E. No. 12) (S.A.E. No.6) 6.82 25,81 .98 3,71 10.24 38,76 1.46 5,53
PF3021 8 8.58 32,45 1.22 4,64 12.86 48,68 1.84 6,96
PF4011 10 2.50 9,46 2.50 9,46 3.75 14,19 3.75 14,19
5 Pistons 5 Pistons
PF4015 10 + 3.50 13,25 3.50 13,25 5.25 19,87 5.25 19,87
(S.A.E. No. 8) (S.A.E. No.8)
PF4021 10 5.00 18,92 5.00 18,92 7.50 28,39 7.50 28,39
PF4011 10 7 Pistons 3 Pistons 3.50 13,25 1.50 5,68 5.25 19,87 2.25 8,52
+
PF4015 10 (S.A.E. No.8) (S.A.E. No.8) 4.90 18,55 2.10 7,95 7.35 27,82 3.15 11,92
PF4018, PV4018 10 4.23 16,01 4.23 16,01 6.35 24,03 6.35 24,03
5 Pistons 5 Pistons
PF4026, PV4026 10 + 6.03 22,82 6.03 22,82 9.05 34,25 9.05 34,25
(S.A.E. No. 12) (S.A.E. No.12)
PF4033, PV4033 10 7.40 28,01 7.40 28,01 11.10 42,01 11.10 42,01
PF6033 10 5 Pistons 5 Pistons 8.07 30,54 8.07 30,54 12.10 45,80 12.10 45,80
+
PF6046 10 (1 Inch Flange)➂ (S.A.E.No.12) 10.67 40,39 10.67 40,39 16.00 60,56 16.00 60,56
PF6054, PV6054 10 11.67 44,17 11.67 44,17 17.50 66,24 17.50 66,24
5 Pistons 5 Pistons
PF6070, PV6070 10 ➂ + ➂ 16.33 61,81 16.33 61,81 24.50 92,73 24.50 92,73
(1 Inch Flange) (1 Inch Flange)
PV6080 10 18.33 69,38 18.33 69,38 27.50 104,09 27.50 104,09
➀ PF1, PF2 and PF3 Series pumps are also available with all pistons isolated. For complete model numbers for all split-flow-cover models and a review of your
application, contact your Dynex sales representative.
➁ Output flow based on typical performance at rated pressure with pressurized inlet where required.
➂ Pattern for standard S.A.E. 4-bolt flange.

5
SPECIFICATIONS

PV2000 Series
Valveplate
Modulating Pumps
Also refer to "Pump Features, Selection and Operating
Recommendations" (dynexpumpoperating.pdf)

CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: sales@dynexhydraulics.com

Power Units & Systems


Dynex/Rivett Inc.
54 Nickerson Road
Ashland, MA 01721 U.S.A.
Tel: 508-881-5110
FAX: 508-881-6849
E-mail: ashland@dynexhydraulics.com

European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: sales@dynexhydraulics.co.uk

For more information


visit our web site:
www.dynexhydraulics.com

BROCHURE NOTES:
Maximum pressures indicated throughout are the maximum intermittent pressures a component can
sustain for occasional, short periods of operation without appreciably reducing the life expectancy.
Contact the Dynex sales department for a review of any application which requires operating above
the rated pressures, flows, speeds or higher than normal operating temperatures.
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative for the most current specifications before ordering. Dynex reserves the right
to discontinue products or change designs at any time without incurring any obligation.

DYNEX High Pressure Hydraulics

Copyright © Dynex/Rivett Inc. Bulletin dynexpespv2000specs.pdf-0203


VALVEPLATE PUMPS & MOTORS

Electro-Hydraulic Pumps and Motors


For Accurate, Remote Speed Control

Dynex valveplate pumps and motors MF2000 AND MV2000 MOTORS –


are used in demanding applications These motors produce high torque
requiring accurate control, and relative to their compact size. The
resistance to dust, dirt, vibration and largest weighs 38 lb (17,2 kg) and
difficult duty cycles. produces up to 62 hp at 3000 psi
PV2000 SERIES PUMPS – These (46 kW at 210 bar).
pumps provide a perfect combination Variable models provide two speeds.
of accurate electro-hydraulic control, A solenoid valve de-strokes the
long service life and high efficiency motor to its lower displacement,
operation. providing increased speed.
On electro-hydraulic modulating MF5000 SERIES MOTORS – Heavy-
models, output flow is proportional to duty motors produce steady power
a variable electrical input signal. with smooth speed variation.
Other models are available with They keep operating even when
pressure compensation, remote con- subjected to extreme pressure
trolled compensation, load sensing spikes, severe vibration and tough
and economical on/off control. duty cycles. They are ideal for
systems with constant starting and
stopping, and sudden direction
reversals.
For information on motors refer to
dynexpesmfmvspecs.pdf

ENERGY-SAVING CONTROLS
Pressure compensation and load sensing
CONTAMINATION match system requirements
TOLERANT BARREL
Special anti-galling coating
provides long service life

S.A.E. NO. 20 INLET PORT


Improves filling for good
performance with cold
fluids and high speeds

MECHANICAL POSITION FEEDBACK


Patented control precisely monitors
and controls cradle angle

ELECTRO-HYDRAULIC CONTROL
Modulating models deliver flow
proportional to variable input signal

PV2 Series Electro-hydraulic Modulating Pump

2
PV2000 SERIES PUMPS

Reliable Modulating
Pumps For Long,
Difficult Duty Cycles
PV2000 Series pumps, with their
durable construction yet simple
electro-hydraulic design, provide
long, reliable service life.
Modulating pumps, with accurate
output, feature a patented design
requiring no additional electronic feed-
back. The rugged design provides
dependable operation in adverse
conditions including extreme heat, dirty
environments and difficult duty cycles.

ACCURATE FLOW CONTROL PV2000 Series Pump


With Electro-hydraulic
Electro-hydraulic modulating models Modulating Control
deliver flow propor tional to an
electrical input signal.
Patented mechanical position
feedback continuously monitors and
adjusts pump output during operation.
A mechanical linkage between cradle
Remote Compensator Rated Pressure
position and the force motor provides
accurate control of pump output.The Offers the convenience of remotely Rated: 3000 psi (210 bar);
result is closed control-loop accuracy regulating maximum pressure from Maximum Intermittent: 4000 psi
without additional electronic feedback. the operator’s station. (280 bar). Note that adjustment of the
Load Sensing compensator is limited to 3500 psi
Machines can use position sensors (245 bar) maximum. For intermittent
or micro-processor input for auto- Automatically provides the output
required by the function at a pressure operation above 3500 psi (245 bar)
matic control; or functions can be contact the Dynex sales department.
controlled with manual input. 150 to 300 psi (10,4 to 20,7 bar)
Components can be located where higher than load pressure. Rated Speed
it’s most convenient, with hydraulics On/Off Control All Models: 2000 rpm
remotely controlled by the operator. Brings pump on-stroke and off-stroke Maximum Speed
in response to an electrical signal. Models PV2024, PV2029: 2800 rpm;
LONG SERVICE LIFE On/off models come with standard Model PV2032: 2600 rpm
These pumps operate reliably in pressure compensator. Maximum Required External Pilot Supply
harsh operating conditions. Piston output can be set using an integral (Electro-Hydraulic Models)
barrels treated with a special anti- stroke limiter control.
Pressure: 200 psi (13,8 bar);
galling coating provide superior Modulating Control Flow: 0.2 gpm (0,8 L/min)
contamination tolerance. Delivers flow proportional to a variable
Internal shafts with 1 inch (25,4 mm) electrical input signal. Modulating
diameters and extra large inlet ports, pumps come with standard pressure FORCE MOTOR ELECTRICAL DATA
for improved filling characteristics, compensator override.
Description Specifications➀
enable these pumps to keep running
under adverse conditions. PUMP SPECIFICATIONS Rated voltage ± 12 V (D.C.)
Full Stroke Voltage ± 9 V (D.C.)
Output at 1800 rpm, 3000 psi
PUMP CONTROL OPTIONS (210 bar) Rated Input Current 490 mA

PV2000 Series pumps are available Model PV2024: Resistance 24.5 Ohms
in three displacements, with a choice 17.7 U.S. gpm (67,0 L/min); Wattage 5.9 Watts
of controls: Model PV2029: Inductance at 1.0 kHz 60 mH
21.5 U.S. gpm (81,4 L/min);
Pressure Compensation Model PV2032: Recommended ± 3 V (D.C.) 60 Hz
Maintains a preset maximum pressure, Dither Signal ➁ Square Wave
24.5 U.S. gpm (92,7 L/min)
adjustable from 500 to 3500 psi (35 to ➀ Specifications at 70° F (21° C)
245 bar). These models include an See “Typical Performance Curves” ➁ A dither signal is recommended to improve
integral stroke limiter for convenient on page 8 for maximum output. response time and reduce hysteresis. A pulse
width modulation signal can also be used to
adjustment of maximum pump output. improve performance.

3
PV2 SERIES PUMP OPERATION

electro-magnetic device with an


Electro-Hydraulic armature that moves in response to DEADBAND HYSTERESIS

Pump Operation the magnitude of the electrical 100


COUNTER-CLOCKWISE
ADJUSTMENT
START

signal. 75

FLOW (%)
The armature controls the movement
ACCURATE OUTPUT FLOW of a pilot spool which ports pilot flow to 50

Modulating models deliver flow pro- the pump control piston. An external 25

por tional to a variable electrical pilot supply of 0.2 gpm at 200 psi CLOCKWISE
ADJUSTMENT

signal supplied to a force motor in the (0,8 L/min at 13,8 bar) is required. 0
OFF-STROKE FULL-STROKE
pilot-stage. The force motor is an The pump cradle in these models is VOLTAGE VOLTAGE

biased to an off-stroke position. The


control piston moves to bring the pump Pump output can be illustrated by a “flow
on-stroke, in response to the electrical versus current” curve. Deadband, or the
signal supplied to the force motor. amount of signal required to initiate flow,
can be adjusted by rotating the force motor.
As the electrical signal is increased,
pump output is propor tionally
increased, up to full flow. Reducing the MECHANICAL POSITION FEEDBACK
signal decreases pump output. Cradle angle, and resulting pump
BIASED
OFF-STROKE
REGULATED
ON-STROKE
For any applied electrical signal, output, is accurately monitored and
there is a distinct position for the controlled by patented mechanical
Cradle movement in modulating pumps is cradle. Pressure to the control piston position feedback. See the drawings
controlled by a variable electrical signal is automatically regulated to maintain below for a description of how this
supplied to the pilot-stage force motor. the commanded cradle position. design operates.

FIGURE 1: The mechanical position feedback design consists


FORCE MOTOR ARMATURE
of a feedback rod (attached to the control piston) and a pilot
sleeve which rides on a feedback cam in the rod. A hole in the PILOT SPOOL
sleeve, in conjunction with the land on the spool, forms a PILOT SLEEVE
control orifice. When no flow is required this orifice is closed.
CONTROL ORIFICE CLOSED
FIGURE 2: In response to the electrical signal, the force motor
armature retracts. The pilot spool, held in contact with the
armature, moves inside the sleeve directing pilot flow to the
control piston through the now open orifice. Movement of the
piston changes the cradle angle and brings the pump on-stroke.
FIGURE 3: The feedback rod moves with the control piston.
When the cradle has reached its proper angle, movement of PILOT FLOW
the feedback cam causes the sleeve to shift in relation to the
spool. This closes the orifice and effectively nulls the pilot FEEDBACK ROD
stage. The control piston and the cradle remain in this position
as long as the electrical signal is unchanged.
Figure 1: Cradle biased off-stroke

SPOOL SHIFTS TO OPEN SLEEVE SHIFTS TO CLOSE


CONTROL ORIFICE CONTROL ORIFICE

CONTROL PISTON

FEEDBACK CAM

Figure 2: Pilot flow ported through control orifice Figure 3: Movement of sleeve nulls pilot stage

4
PV2000 SERIES PUMPS

Pump Type SELECTING PV2 SERIES PUMPS


Variable displacement valveplate The table below indicates which
design with a choice of controls to controls are available for each pump
regulate delivery. size.
Mounting STANDARD PUMPS – Control options
S.A.E. B 2-bolt pattern are shown for models with both
Shaft Data rotations (as viewed from shaft-end).
Standard, S.A.E. B-B 1.00 inch Model numbers listed are for pumps
keyed shaft, with standard S.A.E. B-B 1.00 inch
or S.A.E. B-B spline shaft: keyed shafts or standard S.A.E. B-B Tandem Thru-Shaft PV2000 Series Pumps
1.000/.978 inch diameter standard spline shafts. For pumps with optional
S.A.E. 15 tooth, 16/32 D.P. 30° S.A.E. B spline shaft contact your
involute spline; Dynex representative for specific
Optional S.A.E. B Spline Shaft: model numbers. pump, with a standard S.A.E. B 2-bolt
.875/.853 inch diameter standard pattern, can be mounted “piggy-back”.
S.A.E. 13 tooth, 16/32 D.P. 30° THRU-SHAFT PUMPS – Thru-shaft The internal coupling is a standard
involute spline. models can reduce circuit costs by S.A.E. B-B spline.
eliminating separate drives, saving
Weight (Mass) space and reducing installation time. Thru-shaft pumps are available with a
Compensated: 56 lb (25,4 kg); choice of control options. For
On/Off: 59 lb (26,8 kg); These models are available in a installation details and complete
Modulating: 64 lb (29,0 kg); tandem configuration or as a single model numbers, contact the Dynex
Thru-Shaft: 75 lb (34,0 kg) thru-shaft pump. Any accessor y sales department.

MODEL SELECTION
Clockwise Rotation Counter-Clockwise Rotation
Shaft Pump Control
17.7 U.S. gpm 21.5 U.S. gpm 24.5 U.S. gpm 17.7 U.S. gpm 21.5 U.S. gpm 24.5 U.S. gpm
(S.A.E. B-B) Description
(67,0 L/min) (81,4 L/min) (92,7 L/min) (67,0 L/min) (81,4 L/min) (92,7 L/min)
at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm at 1800 rpm

PV2024-3084 PV2029-3024 PV2032-3147 PV2024-3086 PV2029-3025 PV2032-3148 Keyed


Pressure Compensated ➀
PV2024-3085 PV2029-3026 PV2032-3149 PV2024-3087 PV2029-3027 PV2032-3150 Spline
PV2024-3088 PV2029-3028 PV2032-3151 PV2024-3089 PV2029-3029 PV2032-3152 Keyed Remote
PV2024-3067 PV2029-3030 PV2032-3153 PV2024-3090 PV2029-3031 PV2032-3154 Spline Pressure Compensated ➀
PV2024-2950 PV2029-3032 PV2032-3155 PV2024-3082 PV2029-3033 PV2032-3156 Keyed
Load Sensing➁
PV2024-2951 PV2029-3034 PV2032-3157 PV2024-3083 PV2029-3035 PV2032-3158 Spline
PV2024-3095 PV2029-3038 — PV2024-3097 PV2029-3039 — Keyed
On/Off Control➁
PV2024-3096 PV2029-3099 — PV2024-3098 PV2029-3100 — Spline
PV2024-3091 PV2029-3036 — PV2024-3092 PV2029-3037 — Keyed
Modulating Control➁
PV2024-3073 PV2029-3093 — PV2024-3074 PV2029-3094 — Spline
➀ Pressure compensator setting adjustable from 500 to 3000 psi (35 to 210 bar).
➁ Models listed here also have pressure compensator override.

DIRECTION OF ROTATION 8.83 OUTLET PORT INLET PORT


VIEWED FROM SHAFT END 1.63 (224,3) NO. 16 S.A.E. NO. 20 S.A.E.
(41,4) DRAIN PORT 1.625 1.625
5.750 SQUARE KEY
.25 x 1.00 (6,4 x 25,4) .59 NO. 8 S.A.E. (41,28) (41,28)
(146,05)
(15,0)
ALTERNATE
4.000 101,60
(
3.998 101,55 ) DRAIN PORT
NO. 6 S.A.E. 4.00
(101,6)
1.111
1.101 ( 28,22
27,97 )
8.00 3.12
(203,2) (79,2)
1.000
.998 ( 25,40
25,35 )
DIRECTION
OF ROTATION
.562 (14,27) VIEWED FROM
2.81 PORT END
2 MTG. HOLES
1.81 (71,4)
1.19 1.19 (46,0) 2.56
(30,2) (30,2) ALTERNATE (65,0) .25 (6,4)
DRAIN PORT .375 7.78 5.32 ADJUSTMENT
3.81 NO. 8 S.A.E. 4.06
(96,8) (9,52) (197,6) (135,1)
9.71 (103,1)
7.63 (246,6)
(193,8) 10.92
(323,4)

Pressure Compensated Model (With Stroke Limiter)

5
PV2000 SERIES PUMPS

Installation and
.25 (6,4) INT. HEX
Performance Data (ADJUSTMENT
FOR CRADLE STOP)

Refer to the installation drawing on


4.50
page 6 for dimensions common to (114,3)
REMOTE
all models. PRESSURE PORT
NO. 4 S.A.E.
Standard Seals
7.78 1.63 1.19
Buna-N (Nitrile) (197,6) (41,4) (30,2)
10.92 3.21
Fluid (277,4)
MAX.
(81,5)

High-grade premium petroleum-based


oil, with a combination of anti-wear, Remote Pressure Compensated Model (With Stroke Limiter)
demulsibility, rust protection, and
oxidation resistance and foam resis-
tance properties.
Minimum Filtration Levels
.25 (6,4) INT. HEX
Pump inlet, 25 µ nominal; (ADJUSTMENT
Pressure or return line, 25 µ nominal; FOR CRADLE
STOP)
Pilot supply (electro-hydraulic
models), 10 µ nominal. 5.38
(136,7)
While finer filtration levels than these
are desirable, restricting flow to the
pump inlet must be avoided.
7.78 1.63 2.00 2.81
Inlet Conditions (Minimum) (197,6)
10.92 MAX.
(41,4) (50,8) (71,4)

0 psig (0 bar) to 1800 rpm; (277,4) LOAD SENSING CONTROL PORT


NO. 4 S.A.E.
5 psig (0,35 bar) to 2800 rpm.
Load Sensing Model (With Stroke Limiter)
Mounting
Generally, mount pumps with shaft
horizontal and either drain port
3.88 2.72 .30
vertically up. Consult your sales (98,6) (69,1) (7,6)
MINIMUM
PILOT SUPPLY PORT
representative for other orientations. NO. 4 S.A.E.
2.93
(74,4) .25 (6,4)
Shaft Loading MALE SPADE
TERMINALS (2)
Consult your Dynex sales represen-
2.81
tative for applications which require (71,4)
sideloading.
Start-up 2.81
(71,4)
Fill pump through upper-most case
drain prior to start-up. It may be .25 (6,4)
PRESSURE
necessary to bleed air from pump 9.08
COMPENSATOR 4.06
ADJUSTMENT

outlet for initial priming. (230,6) (103,1)


10.84
(275,3)

FLUID SPECIFICATIONS➀ Modulating Model (With Pressure Compensator)


Fluid Grade
Specification
Summer➁ Winter➂
Viscosity at 5.05
150-300 SUS 75-200 SUS .25 (6,4) MALE SPADE TERMINALS (2) (128,3)
100° F . 2.26 PILOT SUPPLY PORT
(37,8° C) (38,3-64,9 cSt) (14,4-43,1 cSt) (57,4) NO. 4 S.A.E.

Viscosity at 43 SUS 43 SUS


210° F (5,2 cSt) (5,2 cSt) 3.19
(98,9° C) Minimum Minimum (81,0)

-40° F
Pour Point, 0° F
(-40° C)
Typical (-17,8° C)
or Less
Viscosity 95 95 .25 (6,4) INT. HEX
(ADJUSTMENT
Index Minimum Minimum FOR CRADLE STOP)

➀ If fluid conditions fall outside of the range 11.05 MAX.


PRESSURE COMPENSATOR
(280,7)
shown, consult the Dynex sales department.
➁ Warm Weather Grade, Above +40° F (4,4° C)
➂ Cold Weather Grade, Below +40° F (4,4° C) On/Off Model (With Pressure Compensator and Stroke Limiter)

6
PV2000 SERIES PUMPS

TYPICAL PERFORMANCE CURVES (AT 1800 RPM)

PV2024 PV2029 PV2032


KW HP
50

60

40
50
INPUT POWER

)
KE
KE
) RO
RO ST
30 40 ST LL
L (FU
(F UL ER
ER OW
OK
E) OW TP
30 TR TP PU
S U IN
20 (FU
LL INP
R
WE
PO
20 UT
INP

10
10
ATED)
PENSATED) INPUT POWER (COMPENS
INPUT POWER (COMPENSATE
D) INPUT POWER (COM
0 0

N •M LB •IN

250 2250

2000

200 1750
INPUT TORQUE

1500 KE
)
KE
) RO
150 RO ST
1250 E) ST LL
K L FU
T RO UL U E(
S (F RQ
LL UE TO
1000 (FU RQ
UE TO UT
100 O RQ
PU
T INP
750 U TT IN
INP

500
50
250

0 0

U.S.
L/MIN. GPM

100
DELIVERY AT 1800 RPM
90 24
DELIVERY AT 1800 RPM
80
20
DELIVERY AT 1800 RPM
70
DELIVERY

60 16

50
12
COMPENSATOR COMPENSATOR COMPENSATOR
40 SETTING
AT 2500 PSI
SETTING
AT 2500 PSI
SETTING
AT 2500 PSI
175 BAR 175 BAR 175 BAR
AT 1500 PSI AT 1500 PSI AT 1500 PSI
30 8 105 BAR 105 BAR 105 BAR

20
4
10

0 0

100
VOLUMETRIC VOLUMETRIC VOLUMETRIC EFFIC
EFFICIENCY EFFICIENCY IENCY
90
OVERALL EFFICIENCY
80 OVERALL EFFICIENCY OVERALL EFFICIENCY
EFFICIENCY – %

70

60

50

40

30

20

10

0
PSI 1000 2000 3000 4000 PSI 1000 2000 3000 4000 PSI 1000 2000 3000 4000

BAR 50 100 150 200 250 BAR 50 100 150 200 250 BAR 50 100 150 200 250
OUTPUT PRESSURE OUTPUT PRESSURE OUTPUT PRESSURE