You are on page 1of 1

PIER 510-519 SUMMARY AND GENERAL INFORMATION

ZONE 1 (P429~540) : 110 PIERS AND 890 BORED PILES


NO. OF PILES 54
TOTAL PILES 890 (ZONE 1 ONLY)
PERCENTAGE 6.07%
PIER NO. TOP OF PILE FOUNDING LEVEL PILE LENGTH NO. AND DIAMETER OF PILES SOIL CLASS PIER REINF. TYPE PIER TYPE TOTAL WT. OF REBAR REMARKS
P-510 -1.429 -35.992 34.50 4-1500 DIA SC4 TYPE 7 TYPE P1 53.464
P-511 -0.201 -40.701 40.50 4-1500 DIA SC4 TYPE 7 TYPE 1 62.532
P-512 -1.084 -41.584 40.50 4-1500 DIA SC4 TYPE 7 TYPE 1 62.532
P-513 -1.162 -37.162 36.00 4-1500 DIA SC4 TYPE 7 TYPE 1 55.872
P-514 -1.487 -38.987 37.50 4-1500 DIA SC4 TYPE 7 TYPE 1 58.164
P-515 -1.139 -41.639 40.50 4-1500 DIA SC4 TYPE 7 TYPE 1 62.532
P-516 -1.213 -35.713 34.50 6-1500 DIA SC3 TYPE 28 TYPE 1 93.906
P-517 -1.759 -36.259 34.50 6-1500 DIA SC3 TYPE 28 TYPE 1 93.906
P-518 -1.913 -57.413 55.50 9-1500 DIA SC10 TYPE 30 TYPE 1 187.641
P-519 -1.525 -55.525 54.00 9-1500 DIA SC10 TYPE 30 TYPE 1 186.498
10 PIERS 2318 L.M 54 PILES 917.05 Tons

2021.28.10 Engineering Division