Professional Documents
Culture Documents
The content of the product specification consulted relevant laws and industry benchmarks. If you are
came up with some problems, when using our products. Please consult sales people, or call our
The Company reserves the right to modify product, product type and specifications, and other files
Our company has patent right, copyright and other intellectual property on this product and its
software. Anyone can not direct or indirect copy, manufacture, machining and use the product and its
Our company has copyright of the instruction manual. It can not be amended, copied and use any part
without permission.
CHAPTER ONE: FOR SAFE USE ........................................ 1
1.1 FOR SAFE USE ................................................................................................ 1
1.1.1 Before starting............................................................................................................1
1.1.2 Application and purpose............................................................................................1
1.1.3 Working environment ................................................................................................1
1.2 INSTALLATION ................................................................................................ 1
1.2.1 Control box.................................................................................................................1
1.2.2 Accessories .................................................................................................................1
1.2.3 Cable...........................................................................................................................1
1.2.4 Grounding ..................................................................................................................2
1.2.5 Enclosed units and accessories..................................................................................2
1.2.6 Removal......................................................................................................................2
1.3 MAINTENANCE, INSPECTION AND REPAIRS ................................................. 2
1.4 OTHER SAFETY MEASURES ........................................................................... 2
1.5 WASTE TREATMENT ....................................................................................... 2
1.6 CAUTION DISPLAYS AND DANGER DISPLAYS ................................................ 2
Always observe the following matters to safely use the Mitsubishi industrial electronic sewing
machine FCZ740 Series.
1.1.1 Before starting
Before using this control unit, read all of the technical manuals carefully, and correctly use the
unit following the manual.
1.2 Installation
1. Follow this manual when carrying out maintenance or inspections related to this control unit.
2. This unit must be repaired, serviced and inspected only by a worker that has received special
training.
3. Always turn the power OFF before replacing the needle or bobbin, etc., on the head.
4. Use genuine replacement parts for repairs and maintenance.
1. Keep fingers away from all moving machine parts (especially around the sewing machine
needle, etc.)
2. Never drop the control unit, or place objects in the clearances.
3. Do not operate the sewing machine without the protective parts such as the cover, or
protection devices such as the safety breaker.
4. If any damage is observed in the control unit, if the unit does not operate correctly, or if the
operation is suspicious, always suspend operation. Only operate the machine after the
supervisor has adjusted, repaired or inspected the machine.
5. The user must not make improvements or changes without instruction from Mitsubishi.
1)In this manual, the dangers and danger levels that arise with incorrect handling are classified
using the following displays.
The caution display shows that
The warning display shows that incorrect handling can lead to
incorrect handling can lead to injuries or damages to your
death or serious injuries. house, household goods, and
Warning Caution
others.
2
This symbol indicates an
This symbol indicates that the
electrical hazard or caution
instructions must be followed.
(electric shock caution).
This symbol indicates that
This symbol indicates hot
ground wire connection is
Temperature requiring caution.
required.
3
Chapter two: Precautions for use
Warning
1. Do not place foot on the foot switch when 2. Always turn the power OFF when
turning the power ON. leaving the sewing machine.
3. Always turn the power switch OFF before 4. Always ground the grounding wire.
tilting the sewing machine head, replacing
the needle, or passing thread through the
needle.
7. After the replacement of motor, please be sure to reference data set as is shown in the
4
spindle motor installation Angle.
8. Use the machine away from strong noise 9. When connecting the external switch to
sources such as high frequency welders. an optional connector, etc. keep the signal
wire as short as possible. A long wire
could cause malfunctions.
10. The sewing machine will coast to a stop when the power is turned OFF or a power
failure occurs during sewing machine operation.
11. Always align the connector shape and direction, and securely insert the connector.
12. If the position detector's connector dislocates, or the sewing machine is completely
locked, the motor will be turned OFF automatically for a set time to prevent burning.
5
Chapter three: Function and parameter
6
Chapter four: Explanations of basic screen, icons
and operation
4.1 Basic screen
7
4.1.4 Halting
To stop during the stitching, press the HALT switch (installed on sewing machine head; refer to
following drawing). The sewing machine will stop at the needle UP position. (Standard default
setting)To cancel the halted state, press the HALT switch again. The following operations will be
possible when the halted state is canceled.
[1] Restart of stitching by pressing start switch. (Gray pedal)
[2] Movement to stitching start position with forward jog/reverse jog icons.
[3] Lifting of work holder by pressing work holder switch. (Black pedal)
[4] Change of stitching speed by setting stitching speed.
[5] Lifting/lowering of presser bar lifting.
8
A
C
B
Serial
Function Substance
number
[Line at top of screen]
Normal: title on left side, time and date on right side.
A Title bar
When any icon is pressed: The explanation for that icon will appear.
(Refer to Standard screen2.)
Can perform
continuously
B、C Some icons will continue execution while the icon is held down.
function
buttons
When you release the key, it will perform the function of
General corresponding.( most of the key will entering the function screen of
D
buttons
it)
Serial
Instruction
number
Function instruction on left side of the title bar. Waiting for key release, it will change
A
into title.
User press the key, and the title will show the function instruction. Waiting for key
B
release, it will perform the function of corresponding.
9
C D E F
A
B
H J K
I
Serial
Function Substance
number
MENU key includes the function of screen title.
Button MENU function
A When you press the key, it will update the key function of
title
instruction on the screen.
B Reading data Reading patterns from the floppy disk and internal memory.
C Writing data Writing patterns to the floppy disk and internal memory.
Methods of creating
D Pattern input.
stitching data
E Modification mode Pattern modification.
Data conversion
F Pattern conversion.
mode
G Program mode setting parameter operation.
H Check mode Testing operation of all kinds peripheral and liquid crystal.
I Function mode All kinds of function operating.
K Quit return to previous screen.
B C
A
D
G
E
H F
I K 10 L M N
J
Serial
Function Substance
number
A Name The pattern name is displayed.
B Number The pattern No. is displayed.
The pattern is displayed
C Pattern
【Note】 Home position
The current stitching speed setting value is
D Speed
displayed.
Recent number is displayed. No better than 20.
Choose a number and press it, will change current data
E Number shortcut button
【Note】Under the combination sewing condition,it will
shows combination stitching number.
The information of sewing data stitches and simulate sewing
F JOG
operation.
Display various catalogue(refer to 【4.2.2 example of screen
G MENU
2】contents)
H Home Home position return will be executed.
Press and the presser foot will follow the arrow.
I Moving presser foot :Press the icon to make presser foot up.
:needle down
K Pattern preview Display currently shape of pattern and details information.
L NEXT Entering the main screen P2.
Serial
Instruction
number
The stitching data type for the current work holder position is
displayed.(
「SEW」 ,
「FEED」 ,
「2HP」 ,
「USTP」, 「DSTP」 ,
「TRIM」 ,
A
「FEDS」 ,「ASRT」, 「HEVI」 ,「ATUM」, 「BAT」 ,
「FUN1」~「FUN7」 ,
「REPF」 , 「END」 )
B The current number of stitches is displayed.
The total number of stitches (including the feed data, thread
A C
cutting code, end code, and code data) will be displayed.
B The total number of actual stitches (excluding the feed data,
D
thread cutting code, end code, and code data) will be displayed.
C
The operation is confirmed (Jogging in forward/reverse direction)
D 1. If the work holder is lowered after home position return and the
E forward jogging direction (upward arrow) is pressed, the XY table
E (work holder) will move according to the stitching data. When the
icon is released, the operation will stop at that position. When the
jog minus direction (downward arrow) is pressed, the XY table
(work holder) will move in the direction that the stitching data
11
returns. When the icon is released, the operation will stop at that
position.
2. Check pattern data is correct by jogging buttons, before press
start pedal.
A Serial
Instruction
number
B A The sewing machine stitching speed is increased.
The current stitching speed setting value is
B
displayed. (0~9)
C C The sewing machine stitching speed is decreased.
A B C
Serial
Instruction
number
A Look ahead number shortcut button.
Pattern shortcut key(the highlight number is current sewing pattern),when you
B
choose another number, it will change sewing pattern.
C Look behind number shortcut button.
For example:
As shown above, there are 3 pattern numbers in this shortcut button tabulation. And now it is
005.If you choose 006,it will be 006.Display as follow:
12
4.3.4 Show patterns.
A B C D E F
G
H
I
J L
K
Serial
Instruction
number
A Name
B Number
C The size of x direction pattern
D The size of y direction pattern
The total number of stitches (including the feed data, thread cutting code, end
E
code, and code data) will be displayed.
F Pattern data format
G The largest size of x negative direction
H The largest size of x positive direction
I The largest size of y negative direction
J The largest size of y positive direction
K Exits the current mode.
L Pattern is displayed.
13
A B C D
Serial
Function Substance
number
The up counter value is displayed.(Current value/setting
A Up counter value
value)
B Up Counter set up The Up Counter screen is displayed.
C Down Counter set up The Down Counter screen is displayed.
The down counter value is displayed.(Current
D Down counter value
value/setting value)
Refer to Standard The function of these kind button Refer to Standard
E
screen1 screen1.
F Bobbin winding mode Enter bobbin winding mode
G Back Back to Standard screen1
bobbin winding icon is pressed on the Standard screen2.)When the work holder switch is
turned ON and the start switch is turned ON, the sewing machine will start rotating at the set speed.
The XY table will not move at this time. The sewing machine will stop at the needle UP position when
the start switch is turned OFF.
【Note】The bobbin winding operation is determined by the program mode setting.(Refer to
【9.1.11 bobbin winding】)
A
B
D
E
F
Serial
Instruction
number
Bobbin winding setting speed display
A 【Note】determined by parameters「bobbin winding」->「bobbin winding speed
setting」
B Reality bobbin winding speed display.
14
Bobbin winding operation mode display
C 【Note】determined by parameters「bobbin winding」->「setting bobbin winding
Stop mode」
setting time display
D 【Note】determined by parameters「bobbin winding」->「setting bobbin winding
Stop mode at regular time」
E Setting Bobbin winding at regular time, display the rest of time.
F Exits the bobbin winding mode.
4.4.2 The Up Counter screen.
Press icons on the main screen P2, and entering up counter setting screen.
【Note】The methods of counting with the up counter (down counter) and clearing the counter are
determined by the program mode setting.【9.1.9 Counter】
F H
D G
E
Serial
Instruction
number
Changes the setting value or current value.
A
(highlight icons means input status)
B Changes the validity of the up counter.
C Returns to the previous screen.
D Clears the current value. (Press to clear the setting value.)
E Displays the setting value and current value.
F A set value or the selected value is cleared.
G Use to change the setting value and current value.
H Determines the settings.
【Note】The Down Counter screen is the same, except for the valid/invalid icon design.( ).
15
4.5 Reading data A B
H I J K
Serial
Function Substance
number
has been displayed written pattern list(display number and
name)
A Pattern listing
【Note】if the pattern stitches out of range or data damage, it
will indicate information that can not be choose the pattern.
B Page display Current page/total pages display
16
Operation declaration:
1. Enter the pattern reading screen.
Press on the standard screen1/2, and open the menu mode. Press
【Note】Data reading excluding the start position cannot be executed. Read pattern data after
home returning.
When the screen first opens, the mode to read from the internal memory is selected. (The mode
display at the upper left of the screen is )to change to reading from the USB memory.
【Note】if you executed above step without insert U disk, it will shows 「USB disk has extracted
already」prompt information
【Note】if you insert U disk in the current screen, it needs about 5 seconds to be connected,
17
the only way to enter U disk writing mode is connected successfully ,It won’t take anytime to
be connected when the next time to enter U disk mode, as long as you haven’t extracted U disk.
Please choose the sewing pattern number and then press ,it will return to the standard
screen directly when you have chosen successfully.
【Note】if you reading pattern from U disk,press icon and entering pattern writing screen,
system will change pattern format to NPT format automatically and saved,return to standard screen.
4. Other operating.
If there is a large amount of data, press to change the screen. Direct pattern number
④ At this time, desired pattern number [012] is displayed, then press .Standard
screen with the figure of pattern number [012] is displayed.
Press icon in reading pattern screen,and check the usage condition in the internal.
4.5.3 Erasing.
Press (Select) the number of the data to be erased, and press .A message confirming that
you erase the data appears.(if reading from U disk mode will shows「are you sure delete this pattern」
prompt information),follow this information and operation,but it can not erases currently sewing
pattern
K
H I J
Serial
Function Substance
number
A Name The input pattern name is displayed.
B Number The input pattern number is displayed
C Clear If press the icon, all character is deleted.
When the icon is pressed, one of the alphanumeric
D Backspace
characters from the left of cursor can be deleted.
E、F、H、
Refer to reading The function of these buttons refers to reading screen.
J、K
G Input keyboard These buttons are use for input characters.
You can switch the case input.(The blue background is the
I Switch the case
capital input.)
Operation declaration:
1、Enter the pattern writing screen.
Press on the standard screen2/1, and open the menu mode .Press .
【Note】Data writing excluding the start position cannot be executed. Write pattern data after
home returning.
display at the upper left of the screen is ). Change to writing to the USB memory can also be
20
pressed .
Press , and to change the name, press Highlight the icon, and then change
the setting.
When the icon is pressed, one of the alphanumeric characters from the left of cursor can
confirming that you overwrite the data appears. If you do not overwrite the data, press the icon.
The lowest position when the presser foot is lowered can be corrected by following setting .before
sewing operation, please adjust the lowest position of the presser foot.
【Note】if presser foot height is changed by mechanical adjustment, this setting can not be
Used. Please use this setting, after return the presser foot height to the factory shipment
condition.
21
1、Display standard screen
22
Chapter five: Operation setting instruction
Operation setting is mainly to use setting each parameter,each parameter instruction refer to
【9.1 Program mode list】chapter.
23
5.1.3 Example of setting.
24
1. Selection of mode
2. Selection of function
25
4. Checking function setting change
press icon.
(press ).
If you want to choose which has been
modified to initialize, you can press the key
which has parameter name in subscript.
icon.
26
Two kinds of parameters setting: select and input
select
input
Password can be set by each operation import in the parameter in case to protect operation.
27
Enter the Function Mode and press
the icon.
2、Password input
5.4 " System, setting file write" and "Setting file read"
It is possible to restore easily by storing setting changed program mode on the USB memory to
return later.
28
1、The methods of to enter parameter mode
use and backup
press .
2、User Parameters
icon is available ,
3、Save parameter
icon is available ,
29
4、Import Parameter
icon is available ,
5、Backup Parameter
icon is available ,
It can be restore or set factory default values from the current parameter. On the other hand, User
saved the parameter which has been already set for use the future.
30
1、Entering Restore Default Parameter.
,
Refer to【5.3 Encryption parameter】
when user input the password correctly.
Entering Factory Setting Mode.
Choose icon
Choose icon
31
4、Input factory parameters
Choose icon.
32
Chapter six: Explanation of detection mode
A B C E
Press on the standard screen ,
and open the menu mode.
H I
J F D
Instruction :
33
Instruction :
Instruction :
Instruction :
Instruction :
35
Instruction :
Instruction :
then press .
36
Instruction :
Instruction :
Instruction :
38
Chapter seven: Function mode
A C
D F
G I
J
H E
Serial
Function Substance
number
The sewing data is copied "from the internal memory to an
A Copy mode USB memory" or "from an USB memory to the internal
Memory"
Formats and optimizes the internal memory, Clears the
B Format mode
registration of the shortcut icon
C Combination mode Editing combination patterns
D Version confirmation Software version of system confirmation
Backlight 、touch key lock 、brilliance etc. display settings
E Screen Customize can be
provided
Setting parameter value and save to U disk for later backup
F Reset and Backup
operating.
G Factory mode Input the right password to enter factory setting.
H Exit Back to standard screen.
Press icon on the function mode entering copy pattern. The sewing data is copied
"from the memory to an USB memory" or "from an USB memory to the memory".
39
A B
H I
G
Serial
Instruction
number
A Pattern list
B Displayed current page/total page.
D To select all the data.
F Exit.
G The icons to change the page.
Reading and choose memory/USB memory
Operation declaration:
Copy pattern of internal memory to U disk when you entering on this screen,through shift
icon to copy mode.
2、File choice
Choose pattern file what you want to copy from pattern list(the number of 011、012 patterns will
40
After that, press to copy the data. Screen will display「Are you sure to copy this pattern」
prompt message,press icon execute copy operation. If pattern copy from memory to U disk,
pattern will create [HLS_pat] in U disk root directory automatically, and pattern file will copy to
[HLS_pat].
【Note】if memory and U disk has the same pattern number during the copy ,new data will be
covered .
Press icon and choose Format USB flash disk mode,after then press all the
File will be deleted in the USB flash disk,Please previously backup data if you need to.
2、Format internal memory instruction:
Press icon and choose Format memory pattern mode,after then press all the
patterns file will be deleted except for the current pattern in the internal memory. Please
previously backup data if you need to.
3、Format shortcut key:
41
7.3 Combination mode
Enter the combination function to press the key on the function mode screen. The
combination mode is mainly to use creating and editing combination pattern which we called sub-file
was made up of written pattern.
A
B
C
E
G H I J K
NO. Instruction
A Combination pattern name display
B Pagination display
C Reading combination pattern
D Writing combination pattern
E Step-pattern file display
F Exit.
G Page turning
H reading pattern add to combination pattern from memory
I Delete step-pattern file of combination
J Cancel combination pattern
K Confirm current operation
Operating instruction:
1、choose a sub-file
42
Choose pattern file what you want to
added ( choose 001 pattern in here ),
press .
press to confirm.
The other operation refer to【4.6 writing
data】on this screen.
press icon
Return to the Function screen ,
43
5、reading and writing combination pattern file
example.)
A C
F D
H E
NO. FUNCTION INSTRUCTION
Restore default
A Reload factory default parameter of system
parameter
B Encryption Parameter Protect what you need to setting encryption parameter
C View Failure Log Warning recently system information will be displayed.
D System Update Online update software
Password
E management by Setting and Management password by stages for user
stages
Record machine running parameters of all kinds of
F View running Log
accumulation.
Password
G entering factory setting mode to modify password
modification
45
Press icon on the Factory
Setting Mode screen , entering Encryption
Parameters Setting.
Detail refer to 【 5.3 Explanation of
encryption parameter mode】.
press icon.
press to confirm.
47
Chapter eight: Timing sequence
8.1 Thread trim、Thread release Wiper of timing sequence
diagram control
Thread trim output timing sequence as shown under the figure is setting one of the value from
T1~T5 in [LTM] of Trim/Release on the program mode. also if you need adjust the angle and time
setting [TRS]、[TRE] function of Trim/Release mode on the program mode.
As the same thing, Thread release output timing sequence is also setting one of the value From
L1~L5 in [LLM] of Trim/Release on the program mode. and if you need to adjust the angle and time
setting [LRS]、[LRE] function of Trim/Release mode on the program mode.
Wiper output timing sequence is setting [W1]、[W2] function of [Wiper] mode on the program
mode.
Down position DN
ON
Up position UP ON
LTM
setting
TRS(度) TRE(ms)
T1
ON
TRS(度) TRE(度)
T2
Thread ON
Trim
TRS(度) TRE(ms)
T3
ON
TRS(ms) TRE(ms)
T4
ON
TRS(ms) TRE(ms)
T5
ON
LLM
setting
LRS(度) LRE(ms)
L1 ON
LRS(度) LRE(度)
L2 ON
Thread
Release LRS(度) LRE(ms)
L3
ON
LRS(ms) LRE(ms)
L4
ON
LRS(ms) LRE(ms)
L5 ON
W1(ms) W2(ms)
Wiper output ON
48
Chapter nine: Appendix
9.1 Program mode list
9.1.1. Wiper
Factory
Function Specification Unit
setting
WIP Valid/invalid of the wiper output is switched.
ON
Wiper ON/OFF 0:The wiper is invalidated. 1:The wiper is validated.
W1 The output start time of the wiper output (W) can be set.
Wiper output (W)Basis on trimming timing chart, often with no modification 2ms 30
start time Setting range: 0 ~ 998.
W2 The output time of the wiper output (W) can be set. Please
Wiper output (W)set referring to thread trimming timing chart. Setting range: 0 2ms 40
start time ~ 998.
9.1.2. Slow start
Factory
Function Specification Unit
setting
SL Valid/invalid of the slow start is set.
Slow start 0:The slow start is invalidated. 1:The slow start is OFF
ON/OFF validated.
SLN
Number of stitches of the first sewing speed (slow start) can
No. of slow start stitches 2
be set.
stitches
S1 The speed (slow start) of the first sewing can be set. Setting
100RPM 2
Slow start speed range: 2~30.
S2 The speed (slow start) of the first sewing can be set. Setting
101RPM 8
Slow start speed range: 2~30.
S3 The speed (slow start) of the first sewing can be set. Setting
102RPM 15
Slow start speed range: 2~30.
S4 The speed (slow start) of the first sewing can be set. Setting
103RPM 20
Slow start speed range: 2~30.
S5 The speed (slow start) of the first sewing can be set. Setting
104RPM 23
Slow start speed range: 2~30.
SLS Sets effective/ineffective for super-slow start.
Super slow start OFF
0:Ineffective 1:Effective
ON/OFF
SLP
Super slow start Sets Super slow start speed. 1RPM 25
speed
9.1.3. Clamp
Function Specification Unit Factory
setting
Setting pedal switch mode(one pedal/two pedals)
0:one pedal,turn on the switch with one step,clamp will be
down,and then start sewing.
PT
1:two pedals,two pedal operation,clamp control the pedal 1
Pedal input type
and start pedal.
2:three pedals,clamp move to positive and negative direction
start pedal.
49
3:extension:extension pedal
ACS Setting assist clamp or not.
Setting assist clamp 0:Ineffective 1:Effective 0
switch
Extended module Setting extra extended module or not.
0
switch setting 0:Ineffective 1:Effective
RPS Setting overturn device or not.
Whether there is 0:Ineffective 1:Effective 0
overturn device
The start operation when the clamp frame does not down
OST
position is set.
Which starts even if
0: Do not start if the clamp frame does not down position. 0
the clamp frame not
down
1: Starts even if the clamp frame does not down position.
CDO It needs to set assist clamp effectively when you setting clamp
Foot treadle control and assist clamp sequence of fall.
0
the clamp sequence of 0:main clamp 1:assist clamp
fall
AMS Whether the main clamp motion is up when you finished
Being extended status setting processed.
0
when you finished 0:Up 1:Keep
auto processed
AAS Whether the assist clamp motion is up when you finished
Being assist clamp setting processed during the enable assist clamp effectively.
0
when you finished 0:Up 1:Keep
auto processed
RPY Setting overturn presser foot limit the Y axis
Overturn presser foot 0~100:overturn presser foot limit the Y axis mm 0
limit the Y axis
1T
X
Start delay setting for 0~999:setting clamp 1 off delay(TB8) 0
10ms
1 pedal action
9.1.4. Area limit
Function Specification Factory
Unit
setting
ALC Change the sewing area limit effect.
1
Area limit ON/OFF 0:Ineffective 1:Effective
XL The numerical value of the X motor left side area limit
X axis left side] area limit can be setting in the software. Setting mm 100
setting range:0~1000mm.
XR The numerical value of the X motor right side area limit
X axis right side] area limit can be setting in the software. mm 100
setting Setting range: 0~1000 mm.
YU The numerical value of the Y motor rear side area limit
Y axis rear side] area limit can be setting in the software. mm 50
setting Setting range: 0~500 mm.
YD The numerical value of the Y motor front side area limit
Y axis front side] area limit can be setting in the software. mm 50
setting Setting range: 0~500 mm.
54
continues its operation. Furthermore, when the start signal SRT
is ON, machine is stopped.
T:When the operation signal SRT is turned [ON], the sewing
machine continues to run within the time which is set in (WT.)
function.
WT The bobbin winding operation time (timer) can be set. (effective
Bobbin winding s 30
when WSM =[T]) Setting range:1~500
operation time
WSN
Stitches of slowIt can be set slow speed of lifting needle in winding model,
needle 5
speed lifting needle setting range from 0 to 9 stitches
winding
9.1.12. Feed method
Function Specification Unit Factory
setting
WET L:For standard delivery clamp M:Heavy weight setting [M]
Clamp weight L
H:Heavy weight setting [H]
selection
WEL SET value is applied when CLAMP WEIGHT SELECTION
Setting value when (WET.)=[L]. It limits maximum sewing speed of each stitch % 100
clamp is selected length. Setting range: 0~100.
WEM SET value is applied when CLAMP WEIGHT SELECTION
Setting value when (WET.)= [M]. It limits maximum sewing speed of each stitch length. % 80
clamp is selected Setting range: 0~100.
WEH SET value is applied when CLAMP WEIGHT SELECTION
Setting value when (WET.)= [H]. It limits maximum sewing speed of each stitch length. % 50
clamp Setting range: 0~100.
THI L:Standard setting [L]----------(0-3mm)
Cloth thickness M:Thick material setting [M]---(3-6mm) L
selection H:Thick material setting [H]---(6-8mm)
TL
SET value is applied when material THICKNESS
Setting value when
SELECTION (THI.)= [L]. It limits maximum sewing speed of each % 100
cloth0 thickness is
stitch length. Setting range: 0~100.
selected
TM
SET value is applied when material THICKNESS SELECTION
Setting value when
(THI.)= [M]. It limits maximum sewing speed of each stitch length. % 61
cloth thickness is
The factory setting is for approx (3 to 6mm). Setting range: 0~100.
selected
TH
SET value is applied when material THICKNESS SELECTION
Setting value when
(THI.)= [H]. It limits maximum sewing speed of each stitch length. % 50
cloth Thickness is
The factory setting is for approx (6 to 8mm). Setting range: 0~100.
selected
FSL
Non stitch feedNon stitch feed speed for long distance can be set from [0 (slow)]
6
speed setting for to [9 (fast)].
long distance
FSS
Non stitch feedNon stitch feed speed for short distance can be set from [0 (slow)]
7
speed setting for to [9 (fast)].
short distance
9.1.13. Speed
Function Specification Unit Factory setting
HIGH The speed of HIGH speed
100RPM 23
High speed code can be set from 2 to 30.
LOW The speed of LOW speed
100RPM 2
Low speed code can be set from 2 to 30.
55
Speed for MD1 code
MD1
(medium speed 1) can be 100RPM 20
Middle speed 1 [MD1]
set from 2 to 30.
Speed for MD2 code
MD2
(medium speed 2) can be 100RPM 10
Middle speed 2 [MD2]
set from 2 to 30.
9.1.14. Thread trimming/Thread release
Function Specification Unit Factory
setting
TRM Ineffective:The thread trimming is invalidated.
Effective
Thread trimming ON/OFF Effective:The thread trimming is validated.
T1:Thread trimming is begun at TRS setting
(degree) from needle down position, and is ended
at TRE setting (time) from needle up position.
T2:Thread trimming is begun at TRS setting
(degree) from needle down position, and is ended
at TRE setting (degree).
LTM T3:Thread trimming is begun at TRS setting
Setting for thread trimming (degree) from needle down position, and is ended T1
output (T) timing. at TRE setting (time).
T4:Thread trimming is begun at TRS setting
(time) from needle down position, and is ended at
TRE setting (time) from needle down position.
T5 : Thread tension release is begun at TRS
setting (time) from needle up position, and is
ended at TRE setting (time).
TRS
The output start time of the thread trimming output ms
Thread trimming output start 90
(T) can be set. /deg.
time/angle
TRE
The output end time of the thread trimming output ms
Thread trimming output 15
(T) can be set. /deg.
time/angle
T
Thread trimming speed. RPM 200
Thread trimming speed
Effective: Thread trimming is executed (effective
ETC
when STN = DN)
Thread trimming ON/OFF at Ineffective
Ineffective: Thread trimming is not executed
needle up icon operation
(effective when STN = DN)
L1 : Thread tension release is begun at LRS
setting (degree) from needle down position, and is
ended at LRE setting (time) from needle up
position.
L2 : Thread tension release is begun at LRS
setting (degree) from needle down position, and is
ended at LRE setting (degree).
LLM L3 : Thread tension release is begun at LRS
Setting for thread tension setting (degree) from needle down position, and is L1
release output (L) timing ended at LRE setting (time).
L4 : Thread tension release is begun at LRS
setting (time) from needle down position, and is
ended at LRE setting (time) from needle down
position.
L5 : Thread tension release is begun at LRS
setting (time) from needle up position, and is
ended at LRE setting (time).
LRS Start time/angle of thread release output can be ms/deg. 196
56
Thread release output set.
start time/angle
LRE
End time/angle of thread release output can be
Thread release output ms/deg. 0
set.
time/angle
LP
Setting for tension release Outputs tension release signal when the presser
ms 60
outputs time length at presser foot goes up.
foot rise
LFP Open:Thread tension release output is done at
Sets ON/OFF of prohibition of
presser foot up.
thread tension release output at Open
Close:Thread tension release output is not done
presser foot up in non stitch
feed. at presser foot up.
9.1.15. Jog
Factory
Function Specification Unit
setting
--:The XY table moves according to the pattern data while the
JOG icon is ON, and stops when turned OFF.
AL:The JOG [+] icon is turned ON : The XY table moves,
automatically proceeds to the end point. The JOG [-] icon is
turned ON: The XY table moves, automatically returns to the
JGM start point. During movement, the operation will stop if either of
JOG icon function the JOG [+/-] icons is turned ON again. --
setting HA:The JOG [+] or [-] icon is turned ON until XY table reached
at high speed : The XY table will automatically move to the end
point or start point. If the icon is turned OFF before the high
speed is reached, the operation will stop immediately. During
movement, the operation will stop if either of the JOG [+/-]
icons is turned ON again.
Not allow:The JOG operation is possible only when the needle
UJC
is at UP stop position.
Valid setting of JOG Not
Allow : The JOG operation is possible regardless needle
icon excluding needle allow
UP position position. Be aware that the JOG operation becomes valid even
when the needle is in the fabric.
Ineffective:Between continuous JOG, table keeps moving even
JGS the needle up stop code (USTP) or the needle down stop code
Action of stop code (DSTP) is appeared.
Effective
between continuous Effective:Between continuous JOG moving, when the needle
JOG. up stop code (USTP) or the needle down stop code (DSTP) is
appeared, table is stopped.
JSL
JOG speed for long distance can be set from [0 (slow)] to [9
JOG speed setting for 7
(fast)].
long distance.
JPA Down:the presser is down when sewing data among JOG
Whether it is up when movement.
Up
the presser foot will be Up : the presser is up when sewing data among JOG
moved. movement.
57
S8 Sets the timing to start movement of the clamp during
Setting for feed start angle of sewing machine rotation. The setting indicates the angle deg. 260
clamp from the down position. Setting range:160~300.
E8 Sets the timing to end movement of the clamp during
Setting for feed end angle of sewing machine rotation. The setting indicates the angle deg. 80
clamp from the down position. Setting range:40~130.
58
Korean:Display Korean screen
9.1.19. Advanced parameter
Function Specification Unit Factory
setting
MS
The highest spin speed of main Can be set the maximum sewing speed 100RPM 23
axis motor
SED Delay send time after servo enable signal to
ms 100
Main axis motor enable to delay impulse order
SDD
Main axis motor disable to Impulse order to servo enable to release delay ms 100
delay
STT Always open:always open type Always
Halt switch type Always close:always close type close
61
CODE ERROR NAME INSPECTION
MES-P-215 Delete file operation failure.
MES-P-216 File has existed already.
MES-P-217 Over file range.
MES-P-218 Formatting has done.
MES-P-219 Formatting abnormal.
MES-P-220 Without pattern data in [P_Pat] list.
MES-P-221 Without pattern data in memory.
MES-P-222 Pattern data space has not enough.
MES-P-223 Pattern space of memory has fulled already.
MES-P-224 Pattern number don’t existed already.
MES-P-225 Pattern number has existed already.
MES-P-226 Forbidden delete current pattern.
MES-P-227 Forbidden delete the last one pattern.
MES-P-228 Pattern format of memory error.
MES-P-229 Pattern number error.
MES-P-230 Are you sure to delete this pattern.
MES-P-231 Forbidden delete all of pattern data in memory.
Make sure to recover which has been modified
MES-P-232
that you choose value.
Make sure to recover all of parameter has been
MES-P-233
modified.
MES-P-234 Recover parameter success.
MES-P-235 Recover parameter failure.
MES-P-236 Recover factory parameter success.
MES-P-237 Storage factory parameter success.
MES-P-238 Import factory parameter success.
MES-P-239 Export factory parameter success.
MES-P-240 Up counter has fulled already.
MES-P-241 Down counter has fulled already.
MES-P-242 Up counter has been forbidden modification.
MES-P-243 Down counter has been forbidden modification.
Make sure to add angular point or generate
MES-P-244
broken line.
MES-P-245 Make sure to generate arc data.
MES-P-246 Make sure to generate circle data.
MES-P-247 Make sure to generate polygon data.
MES-P-248 Need to return home position operation.
MES-P-249 Must be return to home position operation.
62
CODE ERROR NAME INSPECTION
MES-P-250 Shape points are not enough.
MES-P-251 Must be press down the presser foot.
MES-P-252 Presser foot over distance range.
MES-P-253 Make sure to calibrate touch screen.
MES-P-254 Over maximum needle span.
MES-P-255 Multiple stitching inspection type error.
Multiple stitching over inspection offset distance
MES-P-256
range.
MES-P-257 Multiple stitching over inspection times range.
MES-P-258 Broken line stitching inspection error.
MES-P-259 Broken line stitching over inspection width range
Broken line stitching over inspection needle gage
MES-P-260
range.
MES-P-261 Reverse stitching inspection error.
Reversal times is wrong at the beginning of
MES-P-262
reverse stitching.
Reversal stitches is wrong at the beginning of
MES-P-263
reverse stitching.
Reversal times is wrong at the end of reverse
MES-P-264
stitching.
Reversal stitches is wrong at the end of reverse
MES-P-265
stitching.
Reversal times is wrong with closed reverse
MES-P-266
stitching.
Reversal stitches is wrong with closed reverse
MES-P-267
stitching.
MES-P-268 Storage allocation.
MES-P-269 Shape of points repeatedly.
MES-P-270 Next sewing data error.
MES-P-271 Last sewing data error.
MES-P-272 Address out of range.
MES-P-273 Over length.
MES-P-274 Pattern error.
MES-P-275 Pattern without data.
MES-P-276 Too much stitches.
MES-P-277 Too much point.
MES-P-278 Has second home position already.
There was second home position whether
MES-P-279
deleted it and added new one.
MES-P-280 Pattern only has empty feed.
MES-P-281 Different data type.
MES-P-282 Circle and arc calculation error.
MES-P-283 Curve calculation error.
63
CODE ERROR NAME INSPECTION
MES-P-284 Only closed diagram can being multiple stitching.
MES-P-285 Not function code.
MES-P-286 Can not add thread code.
MES-P-287 The same function code.
MES-P-288 Second home position error.
MES-P-289 Thread trim position error.
MES-P-290 Needle down stop position error.
MES-P-291 Without deviation.
MES-P-292 Without multiple stitching.
MES-P-293 Settings over range.
MES-P-294 Choose wrong point.
MES-P-295 Wrong start/end point.
MES-P-296 Unable scaling.
MES-P-297 Error position,not stitch data.
64