Professional Documents
Culture Documents
The Problem AC input: 120 V or 240 V (±15 %), selectable, 450 mm × 300 mm × 140 mm
Some solar pumps may not provide sufficient flow under all 47 to 63 Hz 17.7 in × 11.8 in × 5.5 in
conditions, especially in unusually cloudy weather or when AC input current: 6.2 A (120 V) or 3.1 A (240 V) weight: 16 kg / 35 lbs
sufficient storage cannot be provided. PV input voltage: Vmp: 130 V DC,
depending on pump controller max. voltages Warranty
The Solution PV max open circuit voltage: 200 V DC
The LORENTZ PowerPack PP600H AC allows the pump to be DC output: 120 V DC (no load), 700 W Warranted to be free from defects in material and work-
powered byan AC generator or mains supply. overload protection: internal fuse, 15 A man-ship for TWO YEARS from date of purchase.
enclosure: steel, gasket-sealed, indoor-use,
The solar array remains connected while the PowerPack acts hinged front cover with key-lock Standards
as a changeover switch between the two power sources. must be protected from direct mid-day sun
As soon as backup power is required the PowerPack can be IP22 Meets the requirements for CE
switched on to bypass the solar generator and supply the ambient temperature: max. 45°C
pump from the auxiliary power source. The changeover from
solar is done automatically after switching on the power
supply for the PowerPack.
solar-direct operation. C US
LISTED
The PowerPack is able to power the pump to its full capac-
ity.
BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice. Pictures may Sun. Water. Life.
130508
differ from actual products depending on local market requirements and regulations.
INSTRUCTIONS
Installation Operation
Warning This device is to be installed, solar pump controller or from the disconnect switch, and Connect the AC power source and turn on the Power Pack
connected and serviced by qualified diverted to the Power Pack. AFTER it has been connected to the pump controller. When
personnel only. Ensure all power sourc- the controller and the Power Pack are turned on, the Sys-
es are disconnected when making con- DC Power Out tem ON light should show on the controller, and the pump
nections to this unit. Follow all appropriate electri- Connect two wires from the DC POWER OUT + and – termi- should start. When the Power Pack is turned OFF (or its AC
cal codes. There are no user-serviceable parts nals to the POWER IN + and – terminals in the solar pump source disconnected), the solar array will remain connected.
inside. controller. When the pump is running on solar and the Power Pack is
switched ON or OFF, the sudden transition may “surprise”
Mounting Internal Fuse the pump controller and cause the pump to stop. This is not
Mount the PowerPack close to the pump controller, in a There is a 15 A fuse in the upper left. This fuse should blow a fault. It will restart automatically in about 2 minutes.
vertical position. Cover the unit from direct rainfall. You will only if there is an electrical fault in the PowerPack, or the
find four mounting brackets in a plastic bag inside the en- pump controller, or the wiring between them. It will NOT If the AC power source is from the utility line (not a genera-
closure (see figure 1 and 2). blow if the pump is short-circuited or overloaded. (In that tor), it is best to turn OFF the PowerPack or its AC supply
case, the pump controller will stop the pump.) when it is not needed. Otherwise, the PowerPack will draw
WARNING PowerPack must be protect- power all the time. Switching can be done automatically us-
ed from solar heat, especially direct Spare fuses are included in the parts bag. Additional fuses ing a timer switch on the AC line. Timer switches of many
mid-day sun. Mount it in the shade. If are available from electronic suppliers (5 × 20 mm, 15 A, kinds are available from suppliers of electrical, swimming
there is no shady location, make a time-delay). If the fuse continues to blow, the fault must be pool and irrigation equipment.
shade from sheet metal. Allow free air circulation found and repaired. Substitution of a higher-rated fuse or
around the cooling fins on the back of the enclo- bypassing the fuse will void the warranties of both the AC Once the PowerPack is turned OFF it will take up to 50 sec-
sure. For wall mounting, use spacers to stand it out, PowerPack AND the pump controller. onds for the POWER ON LED to be OFF. This indicates that
so the cooling fins do not touch the wall. there is still voltage stored in the capacitor.
Wire Sizes
All wires must be #14 AWG (2.5 mm2) or larger.
AC Power Source
Install a 15 A circuit breaker at the power source or distribu-
tion box.
AC Input
L N 1 2 3
Connect AC power to terminals L and N. (For a 240 V con-
nection, N does NOT indicate neutral.) 120 V DC
AC SOLAR
GROU ND
GROU ND
GROU ND
BERNT LORENTZ GmbH & Co. KG Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice. Pictures may Sun. Water. Life.
130508
differ from actual products depending on local market requirements and regulations.