You are on page 1of 5
Be TAMINA GAS JOB NO. [DOC. NO. REV. PT E1 - PERTAGAS 9544 | _SSNP-01-INS-DTS.098 D 5, PT TRIPATRA PAGE 1 oF 5 THIATRA, ENGINEERS AND CONSTRUCTORS SOUTH SUMATRA NGL PROJECT DATASHEET Engineering, Procurement, Construction & Commissioning DATASHEET FOR FIRE ALARM PANEL NGL EXTRACTION PLANT AREA ye os. 16-Sep-2010| Approved for Design ‘Yoo | FAS B__ | 3-Aug-2010 Issued for Approval FAS | FRO ‘A__| 8-Mar-2010| _ Issued for Internal Review Fas_|_RBK BY DATE REV DATE DESCRIPTION prep | cHKD ‘CLIENT 27 PERTAMINA CAS PT E1 - PERTAGAS ‘JOB No. 9544 lboc. no. : REV ‘SSNP-01-INS-DTS-098 D A, PT TRIPATRA rnivatra ENGINEERS AND CONSTRUCTORS PAGE 2 OF 5 DATASHEET FOR FIRE ALARM PANEL SOUTH SUMATERA NGL PROJECT Engineering, Procurement, Construction & Commissioning REVISION D ‘TABULATION OF REVISED PAGE SHEET REVISION ED) o> rereramman cas JOB No. |Doc. No. Rev PT E1- PERTAGAS. 9544 | SSNP.01-INS-DTS.098 > PT TRIPATRA eee snaipaida ENGINEERS AND CONSTRUCTORS SOUTH SUMATERA NGL PROJECT DATASHEET FOR FIRE ALARM PANEL Engineering, Procurment, Consuction& Commisining REVISION SUMMARY Revision Date Description of Changes x E-MarTO fies or itera! Review @ ZAOg1O [issued for Approval o TE: Sep-10 [Approved Tor Design, Inooporate Company comments = Page 5: Update quanity of Smoke Detector, refer to datashael SSNP-OT-INS-DTS.097 Page 5: Change term Digital Quiput to Vollage Free! CE) orrrnnn cnn PT E1 - PERTAGAS. ‘JOB NO. |DO¢. NO. : REV 9544 ‘SSNP-01-INS-DTS-098 D od PT TRIPATRA ENGINEERS AND CONSTRUCTORS PAGE 4 OF 5 TREATRA ‘SOUTH SUMATERA NGL PROJECT GRTRGIRET EOE Gee AIG EEL Engineering, Procurement, Construction & Commissioning Tas Naribe [onraPi04 ‘Sone controt eutaing,Ofice Bulding & MaintonanceNVorahop Bulding GENERAL Layout Oring No [SSNP-OTINSALAY.I01 Tambent Terperaiurs [70-95 eg F.Inaoor =A Conioned 3a eo 100% RH [Power Sunny [20.vac. 60 He-1 phase Fon UPS z © [uy = [ater Unt Requred. ow charger [conor fcr conroter bases, Aaceasabe Display end Nam naiaton ntoral LED's ard buzzer not 24 VDC Leap input Sail Gorvuricaio to Devices, 4 bape awet system [72] Relay Opt (4 VOC Votage Fee) Sea 3 ouput ‘Communiaton Link, Ethemet TCPIP potoa. 168 4 ico [Pevodaty check ana wat eon 16 [Syston Faut [Sat inlose oncions to delet and earsmuniale ay conlion Hat ght brevet ee selection 15 [ousng maior Pained Wid Soe) 19 Finish Cour [Rea 20 [Hazardous Protection [General Purpose non-hazardous construction [3 [ngeesProtecten iP «2 min 22 [Cable Ent SO MOO, baton 25 oun [Surtace Mounted 24 25 Nana pale pass omens [22rd [ 25 29 orator Iva 30 [Model Number [va purchase [31 [serai Nonber 22 |Puehaes OrserNe 33 ter Number 2. Detector devices shal be esetabl trom pane. 4. Pane shal be UL or FM ites, “4 le Alem Panal abe located at Central Control Room (CCR) Vendor to rove name plat tg number permanent staced o equipment GF vemranma cas PT E1 - PERTAGAS. JOB NO. |DOC. N REV 9544 ‘SSNP-01-INS-DTS-098 D yj PT TRIPATRA suifcéza ENGINEERS AND CONSTRUCTORS PAGE 5 OF 5 DATASHEET FOR FIRE ALARM PANEL, SOUTH SUMATRA NGL PROJECT Engineering, Procurement, Construction & Commissioning FIRE ALARM PANEL INPUT/OUTPUT LIST tem Description ‘Signal Type / Qty. Remarks [INPUT SIGNAL [smoke Detector “ Sera oop, Adsresabie | Convo Guiding | Heat Detector ‘loop MEG Room Manual Cal Point Heat Detector IManval Call Point 2 Smoke Deteco a ‘Serial oop, Aderesabie ‘ffce Buidng | ree ‘1008 : a ~|- Serial op, Adesabio Maintenance? | 3] Smoke Detector \[ttea Heat Detector 2ea [Manual Gall Point 2ea Workshop Buiding | [SPARE LOOP |OUTPUT SIGNAL 7 [Gant FrerSnake Naat FOS: ~ Conirel Building & MGG Room = Offce Buling Wea) Maintenance / Workshop Bulking (2) 2 [Pre-Alarm Signal toFGS Votage Free, 24VDC. 30a | ConrelBudhg & MOC Roan) —— =) Office Busing oa) a [oemmon Alarm 0 FGS { [Running Indication FSS 5 [spare =Mintenance / Workshop Bung (68) | Votage Free, 24 VDC. tea | jotage Fe, 24 VDC. tea oo, 24 VDC. tea 6 |Communication Link

You might also like