You are on page 1of 4
CALIBRATION CERTIFICATE Issued Tentec Limited Part of the Atlas Copco Group Unit F1, innovation drive, Pendeford, Fecceerasrersec Atlas Copco Page 1 of2 Be ae Wolverhampton West Midlands, WV9 5GA, UK Cortificate No: T-5155 Calibration Date: 30/03/2021 ‘Approved Signatory Calibration Engineer: Ian Watson signee: To~ Luho — tan Watnon Tool Description Description: Hydraulle Torque Wrench Model: RT-3SQDR Serial No: 193124/16-065, Customer POWER TOOLS DISTRIBUTION N.V (PTD) INDUSTRIELAAN 40 B.3730 HOESELT BELGIUM +32 (0) 89 510 414 i Uses Torque Transducers: TSD 4011 SIN (6562) Calibrated by Atlas Copco BLM - Accredia ‘Accreditation - LAT 059 Pressure Transducers: TSD 10KPT RHYD SIN (136112) Calibrated by CHAMOIS METROLOGY - UKAS Accreditation - 0822 Display Unit: TSD 6500-2 SIN (20845) Calibrated by - Atlas Copco BLM - Accredia Accreditation - LAT 059 Reaction Foot: RA-193124/16-065 Calibration Procedure 0 to 4,000 Ibf'ft Torque transducer From 10% to 100%: 0.1% From 0% to 10%: #2 divisions (10 LB-FT) (0 TO 10000 Ps! Pressure transducer From 10% to 100%: 0.1% From 0% to 10%: 42 divisions (2 Psi) Max Capacity Torque - 40,000 thf ft Pressure - 10,000 Psi Calibration done in accordance with procedure "TCP -REVB",based on standard ISO 6789; 2003 Traceability ‘All measuring equipment used for calibration purposes is traceable to National or Internationally recognised standards ‘Test Conditions ‘Temperature: 21.07 40.22 ‘The temperature did not fluctuate by more than +/- 1° Celsius during the measurement series ‘This certficate provides traceabilty of measurement to the SI system of units andlor to nits of measurement realised atthe National Physical Laboratory or other recognised national metrology insitutes, Ths certificate may not be repoduced other than in ful, except with ‘the prior writen aproval of the issuing laboratory Intemet: www tentec.net “Telephone +44 (0)121 624 1990 Page 2 of 2 CALIBRATION CERTIFICATE Certificate No: 17-5155 Calibration Date: 30/03/2021 Model: RT-3SQDR Serial No: 193124/16-065 2000 | 138 ||1998.6/138 |638.0 [658.0 [660.0 /659.5 [657.5 _|654.6 _| [+/-] 3.00% | 6000 | 414 [600.8414 |1969.0 [1971.0 [1973.0 [1977.0 |1981.0 [1974.2 | [+/-] 3.00% 40000) 689 | |9999.2/689 |3267.5 |3269.0 [3275.5 (3280.5 [3267.0 |3275.9 | [+/-] 300% 2000 | 138 | |1998.6|138 |865.0 (892.1 (894.8 [894.2 [891.5 |887.5_| [+/-] 3.00 % 6000 | 414 | (6000.8)474 |2669.6 2672.3 |2675.0 |2680.5 [2685.9 [26767 | [+/-] 3.00% 10000 689 | /9999.2)689 [4430.1 (4432.2 4441.0 [4447.6 |4456.6 |4447.5 | [+/-] 3.00% 6,000 ONm ‘000 2000 3000 +~—«4000~=«=«s00 «600» 7000» 8000» 900010000 Pressure (PSI) This alatoncortat va tr 12 months “Thit rom stock dorpteh dato. mot Place of #1: Powor Too Ostibution NY SIO stock dssareh doe: 19 (04 [24 Pe same We VR Internet: wwwetentec.net Telephone +44 (0)121 524 1990 Tentec Limited Esc nasser une et Atlas Innovation Drive Pendeford, Wolverhampton Wv9 5GA [ieee aie) United Kingdom Telephone +44 (0)121 524 1990 ATLAS COPCO POWER TOOLS DISTRIBUTION internet: wrw.tentec.net INDUSTRIELAAN 40 email: bolting@uk.atlascopco.com 8.3730 HOESALT BELGIUM Customer ON 4510626404 Our Ref 210895 BE0443676020 Advice Note 30/03/2021 Page 1/1 certificate of conformity & pressure test certificate Qty Description Part Number 1 RT-03 Square Drive Wrench (2494201005 Test Pressure 700 BAR, Max Working Pressure 700 BAR SIN. 199124/16-065 EC DECLARATION OF INCORPORATION Hydraulic Torque Wrench The equipment listed left are intended for assembly with, bol tensioning hose, bolt tensioners, and bolt tensioning pumps supplied or approved for use by Tentec Ltd, to constitute machinery covered by Directive 2008/42/EC., They must not be placed into service untl all items have been declared in ‘conformity with the provisions of the 2008/42/EC Directive. The following EHSR's sections covered by annex C of the directive have been complied with. Section 1,3 & 4. Assembly instructions are provided by Tentec in accordance with Annex VI. A technical document is compiled in accordance (itn Arn ao he Dvecve, LOCK NAME DAVID JONES — BLOCK POSTION. GeNERAL NANAGER UKCA DECLARATION OF CONFORMITY Hydraulic Torque Wrench This document confirms that the products listed above conform to UKCA requirements. Tentec Uc take full responsibilty for the compliance with UKCA requirements. BLOCK NAME DAVID JONES BLOCK POSITION GENERAL MANAGER Freda We herewith certify based on pressure testing and dimensional inspection that the items supplied under the above purchase order are in accordance withthe requirements of the order in particular to ‘a) The fullment of material requirements. ') The fullment ofthe required accuracy to, gauge, tolerances, quality surface (©) The fullment of performance ‘Authorised Signature foun Lonorn ToP- 420898

You might also like