You are on page 1of 3
CALIBRATION CERTIFICATE i Beas ERS od Sitlas Copco tentec Limited Part of the Atlas Copco Group pee Unit F1, innovation drive, Pendeford, Wolverhampton West Midlands, WV9 5GA, UK CertificateNo: T-5147 Calibration Date: 24/03/2021 Approved Signatory ieecion togieoer an Wien signed: —Te~ Luehert——_ an Watson Tool De jon Customer Description: Hydraulic Torque Wrench “POWER TOOLS DISTRIBUTION N.V (PTD) | INDUSTRIELAAN 40, RT-3SQ0R B-3730 HOESELT tes12416-062 BELGIUM 32 (0) 89510411 Equipment Used Torque Transducers: TSD 4011 SIN (6562 Calibrated by Attas Copco BLM - Accredia Accreditation - LAT 059 Pressure Transducers: TSD 10KPT RHYD SIN (196112) Calibrated by CHAMOIS METROLOGY - UKAS Accreditation - 0822 Display Unit: TSD 6500-2 S/N (20845) Calibrated by - Atlas Copco BLM - Accredia Accreditation - LAT 059 Reaction Foot: RA-193124/16.062 Calibration Procedure 0 to 4,000 Ibf ft Torque transducer From 10% to 100%: 0.1% From 0% to 10%: #2 divisions (10 LB-FT) (0 TO 10000 Psi Pressure transducer From 10% to 100%: 0.1% From 0% to 10%: 42 divisions (2 Psi) Max Capacity Torque - 40,000 Ibt ft Pressure - 10,000 Psi Calibration done in accordance with procedure "TCP6 -REVB" based on standard ISO 6789: 2003 ‘Traceability ‘All measuring equipment used for calibration purposes is traceable to National or Internationally recognised standards Test Conditions ‘Temperature: 20.09 Humidity: 40.60 ‘The temperature did not fluctuate by more than +/- 1° Celsius during the measurement series This cerlfcate provides traceabilty of measurement to the SI system of units andlor to units of measurement realised atthe National Physical Laboratory or other recognised national metrology institutes. Ths certificate may not be repoduced other than in ful, except with ‘he prior written aproval ofthe issuing laboratory. Intemet wor tentecnet Telephone +44 (0)121 624 1990 Page 2 of 2 CALIBRATION CERTIFICATE Cortificate No: 17-5147 Callbration Date: 24/03/2021 Model: RT-3SQDR Serial No: 193124/16-062 2000 | 138 |/1999.2/138 639.5 [655.5 657.0 |656.0 658.0 [653.2 _| [+/-] 3.00% [e000 | 414 | /5998.8)474 1969.0 |1976.5 1976.0 _|1978.5 _|1981.5 1976.3 | [+/-] 3.00% (10000) 689 | 9998.2/689 3286.0 3284.5 (3276.5 [3278.0 (3277.5 |32805 | [+] 300% 2000 | 138 ||1999.2/138 [867.0 [8887 [890.8 [889.4 (892.1 (885.6 _| [+/-] 3.00 % 6000 | 414 | /5998.8/414 [2669.6 [2679.8 |2679.1 |2682.5 (2686.6 [2679.5 | [+/-] 3.00 % 10000] 689 | 998.2689 /4455.2 (4453.2 4442.3 |44aa.4 [4443.7 [4447.8 | [+7] 3.00% cen: nd IbFft nooo 2000 3000 ~~ 4000 ~~«s0o~~—«6000 «7000 «000 | 00010000 Pressure (PSI) Iscton cathe ns “Thi Phos se: Powe Tos tution BE sercenensue (ol | 2.4 At seme: Ue ya si Intemet: www tentec.net Telephone +44 (0)121 524 1990 Tentec Limited Rees Unie Ft Innovation Drive Pendeford, Wolverhampton \W9 5GA eS Unites Kingdom Telephone +44 (0)121 524 1990 ATLAS COPCO POWER TOOLS DISTRIBUTION internet: www.tentec.net INDUSTRIELAAN 40 ‘email: bolting@uk.atlascopco.com B-3730 HOESALT BELGIUM Customer O/N. 4510613089 2 eouiserendo Our Ref 10814 Advice Note 23/03/2021 Page 1/1 certificate of conformity & pressure test certificate Qty Description Part Number 1 RT-08 Square Drive Wrench 18434201005 Test Pressure 700 BAR ‘Max Working Pressure 700 BAR SIN 193124/16-062 EC DECLARATION OF INCORPORATION Hydraulic Torque Wrench The equipment listed left are intended for assembly with, bol tensioning hose, bolt tensioners, and bolt tensioning pumps supplied or approved for use by Tentec Lid, to constitute machinery covered by Directive 2006/42/EC. They must not be placed into service until all tems have been declared in ‘conformity with the provisions of the 2006/42/EC Directive. The following EHSR's sections covered by annex C of the directive have been complied with. Section 1,3 & 4. Assembly instructions are provided by Tentec in accordance with Annex VI. A technical document is compiled in accordance with Annex VII of the Directive. BLOCK NAME DAVID JONES BLOCK POSITION GENERAL MANAGER UKCA DECLARATION OF CONFORMITY Hydraulic Torque Wrench This document confirms that the products listed above conform fo UKGA requirements. Tentec Ld take full responsiblity for the compliance with UKCA requirements. We herewith certty based on pressure testing and dimensional inspection thatthe items supplied under the above purchase order ara in accordance with the requirements ofthe order in particular to fa) The fulfilment of material requirements. 5} The fulfilment of the required accuracy to, gauge, tolerances, quality surface (o) The fullment of performance Authorised Signature oowiap ante TOP. 436317

You might also like