You are on page 1of 3
CALIBRATION CERTIFICATE ae es ead Sltlas Copco _ tentec Limited Part of the Atias Copco Group a Unit F1, innovation drive, Pendeford, Wolverhampton West Midlands, WV9 5GA, UK Calibration Date: 14/04/2021 ‘Approved Signatory soed: J e~ Lalo — lan ten Customer Description: Hydraulic Torque Wrench POWER TOOLS DISTRIBUTION N.V (PTD) : INDUSTRIELAAN 40 ena B.3730 HOESELT Sorial No: 18/22368-006 BELGIUM +32 (0)89 510.411 Equipment Used Torque Transducers: TSD 40011 SIN (6722) Calibrated by Atlas Copco BLM - Accredia 0 to 40,000 Ibf-ft Torque transducer Accreditation - LAT 059 From 10% to 100%: 0.1% From 0% to 10%: #2 divisions (10 LB-FT) Pressure Transducers: TSD 10KPT RHYD SIN (170393 Calibrated by CHAMOIS METROLOGY - TO 10000 Psi Pressure transducer From 10% to 100%: 0.1% UKAS Accreditation - 0822 From 0% to 10%: 42 divisions (2 Psi) isplay Unit: TSD 6500-2 SIN (20016 Calibrated by - Atlas Copco BLM - Accredia Max Capacity Torque - 40,000 Ibf ft Accreditation - LAT 059 ee 40,000 Pal Reaction Foot: RA-15/22368-006 Calibration Procedure Calibration done in accordance with procedure "TCP6 -REVB" based on standard ISO 6789: 2003 Traceabili ‘All measuring equipment used for calibration purposes is traceable to National or Internationally recognised standards Test Conditions ‘Temperature: 19.78 Humidity: 33.96 ‘The temperature did not fluctuate by more than +/- 1° Celsius during the measurement series “This cerifcate provides traceabilty of measurement to the SI system of units and/or to units of measurement realised atthe National Physical Laboratory or other recognised national metrology institutes. This certificate may not be repaduced other than in full except with the prior written aproval ofthe issuing laboratory. Interet wwn.tentec net ‘Telephone +44 (0)121 524 1990 Page 2 of 2 CALIBRATION CERTIFICATE Certificate No: S-5054 Calibration Date: 14/04/2021 Model: RT-25SQ DR Serial No: 15/22368-008 '2000 | 138 | |1999.4|138 |5090.0 [5200.0 [5200.0 [5205.0 5195.0 _|5178.0 I (6000 | 414 | |5999.6/414 |15870.0 |15925.0 | 15900.0 |15920.0 | 15905.0 |15904.0| [+/-] 3.00 % 10000) 689 | |10000,/690 |26735.0 |26630.0 |26785.0 |26660.0 '26700.0 |26702.0| [+/-] 3.00% 2000 | 138 |/1999.4/138 6901.1 [7050.3 |7050.3 [7057.0 [7043.5 _|7020.4 | [+/-] 3.00 % 6000 | 414 | '5999.6|414 21516.8 |21591.4 |21557.5 |21584.6 |21564.3 |21562.9| [+/-] 3.00 % |To000) 89 | |10000./690 |36247.8 |36105.4 |36315.6 |26146.1 |36200.3 |36203.1) [+] 3.00 % js 40,000 35,000 30,000 25000 $ 5 20.000 e 15,000 "2000 Intemet www.tentec net ‘3000 4000 ~=~=«S000 (8000 Pressure (PSI) 7000 8000900010000 ‘This calibration certileate is valid for 12 months from stock despatah date. Stock despatch date £0! f Place of issue, jo, Signature Telephone +44 (0)121 524 1980 Tentec Limited oe se ees Unit Ft Innovation Drive fltlas Pendeford, Wolverhampton Ww9 5GA eee United Kingdom Telephone +44 (0)121 524 1990 ATLAS COPCO POWER TOOLS DISTRIBUTION internet: www-tentec.net INDUSTRIELAAN 40 email; bolting@uk.atlascopco.com B-3730 HOESALT BELGIUM ‘Customer O/N 4510639359 Our Ref 210979 BE0443676020 Advice Note 14/04/2021 Page 1/1 certificate of conformity & pressure test certificate Qty Description Part Number 1 Square Drive 8494201025 RT-25 SIN. 16/22368-006 EC DECLARATION OF INCORPORATION Hydraulic Torque Wrench The equipment listed left are intended for assembly with, bolt tensioning hose, bolt tensioners, and bolt tensioning pumps supplied or approved for use by Tentec Ltd, to constitute machinery covered by Directive 2006/42/EC. They must not be placed into service until all tems have been declared in ‘conformity withthe provisions of the 2006/42/EC Directive. The following EHSR's sections covered by annex C of the directive have been complied with. Section 1,3 & 4. Assembly instructions are provided by Tentec in accordance with Annex VI. A technical document is compiled in accordance with Annex VII of the Directive. BLOCK NAME DAVID JONES BLOCK POSITION GENERAL MANAGER UKCA DECLARATION OF CONFORMITY Hydraulle Torque Wrench This document confirms that the products listed above conform to UKCA requirements. Tentec Ltd take full responsibilty for the compliance with UKCA requirements. BLOCK NAME DAVID JONES ae BLOCK POSITION GENERAL MANAGER << Fi a We herewith certify based on pressure testing and dimensional inspection that the tems supplied under the above purchaee order are in accordance with the requirements of the order in particular to 2) The fulfment of material requirements, 1b) The fuliment ofthe required accuracy to, gauge, tolerances, quality surface (©) The fulfiment of perfomance ‘Authorised Signature eN Tap. 437011

You might also like