Page 1 of 2 CALIBRATION CERTIFICATE Eas Issued Sltlas Copco _ tentec Limited Part of the Atias Copco Group feeritaa rae Ss) Unit F1, innovation drive, Pendeford, Wolverhampton West Midlands, WVS 5GA, UK Certificate No: §-4843 Calibration Date: 30/11/2020 Approved Signatory Calibration Engineer: lan Watson igned: “To~ Lugo —— lan Watson Too! Description Description: Hydraulic Torque Wrench Model: RT-25 SQ DR Serial No: 15/16003.018 Customer POWER TOOLS DISTRIBUTION N.V (PTD) INDUSTRIELAAN 40 8.3730 HOESELT BELGIUM #32 (0) 88 510 414 Equipment Used Torque Transducers: TSD 40011 SIN (6722) Calibrated by Atlas Copco BLM - Accredia Accreditation - LAT 059 Pressure Transducers: TSD 10KPT RHYD S/N (170393) Calibrated by CHAMOIS METROLOGY - UKAS Accreditation - 0822 Display Unit: TSO 6500-2 SIN (20916) Calibrated by - Atlas Copco BLM - Accredia Accreditation - LAT 059 Reaction Foot: RA-15/16003-018 Calibration Procedure Calibration done in accordance with procedure "TCP6 -REVB", ‘Traceability 0 to 40,000 Ib ft Torque transducer From 10% to 100%: 0.1% From 0% to 10%: #2 divisions (10 LB-FT) (0 TO 10000 Psi Pressure transducer From 10% to 100%: 0.1% From 0% to 10%: #2 divisions (2 Ps) ‘Max Capacity Torque - 40,000 Ibf ft Pressure - 10,000 Psi jased on standard ISO 6789: 2003 ‘All measuring equipment used for calibration purposes is traceable to National or Internationally recognised standards ‘Test Conditions ‘Temperature: 18.02 Humidity: 48.61 ‘The temperature did not fluctuate by more than +/- 1° Celsius during the measurement series “This cartficate provides traceabiity of mes urement to the SI system of units andlor to units of measurement realised atthe National Physical Laboratory or other recognised national metrology institutes. Ths ceriiicate may not be repoduced other than infu, except with the prior writen eproval of the issuing laboratory. Intemet wwwtentec.net Telephone +44 (0)121 624 1980 Page 2 0f2 Certificate No: $-4843 Calibration Date: 30/11/2020 Model: RT-25SQ0R Serial No: 15/16003-018 CALIBRATION CERTIFICATE 2000 | 138 ||1999 |138 |5270.0 |5300.0 (5255.0 [5215.0 |5205.0 [5249.0 | [+/-] 3.00% 16000 | 414 | |5998.8/414 |16000.0 |15990.0 |15960.0 |15935.0 |15840.0 |15945.0| [+/-] 3.00 % 10000) 689 | {9999 (689 |26735.0 |26740.0 |26845.0 |26815.0 |26560.0 |26739.0| [+/-] 3.00 % 2000 | 138 | |1999 138 |7145.2 [7185.8 (7124.8 (7070.6 |7057.0_|7116.7 | [+/-] 3.00% 6000 | 414 | |5998.8/414 |21693.1 |21679.5 |21638.9 |21605.0 |21476.2 |21618.5| [+/-] 3.00% 10000) 689 /9999 |689 (36247. 8 |36254.6 36396.9 |36356.3 [36010.5 |36253.2| [+/-] 3.00% 40,000 = [as] ss.000 oe [26739] «y 25000 ae g < z 20,000 & 415,000 10,000 5,000 Internet: wwe tentec.net aun s000”~~s0o0~”~=~Sooo~”~«OOD*~S~*~«SOO~S*~*«OSS*SC«C S(O Pressure (PSI) ‘This calibration certitate is valid for 12 ‘months from stock despatch date Stock despatch date Place of issue. Signature_ Telephone +44 (0)121 524 1990 Tentec Limited ea unit Ft Atlas Innovation Drive Pendeford, Wolverhampton W9 5GA, aaa United Kingdom Telephone +44 (0)121 524 1990 ATLAS COPCO POWER TOOLS DISTRIBUTION internet: wwww.tentec.net INDUSTRIELAAN 40 ‘email: bolting@uk.atlascopco.com B-3730 HOESALT BELGIUM Customer O/N. 4510427082 ‘Our Ret 203101 BE0443676020 Advice Note 30/11/2020 Page 1/1 certificate of conformity & pressure test certificate Qty Description Part Number 1 Square Drive (9434201025 RT-25 SIN 16/16003-018 EC DECLARATION OF INCORPORATION Hydraulic Torque Wrench The equipment listed left are intended for assembly with, bolt tensioning hose, bolt tensioners, and bolt tensioning pumps supplied or approved for use by Tentec Ltd, to constitute machinery covered by Directive 2006/42/EC. They must not be placed into service until all items have been dectared in conformity with the provisions of the 2006/42/EC Directive. The following EHSR's sections covered by annex C of the directive have been complied with, Section 1,3 & 4. Assembly instructions are provided by Tentec in accordance with Annex VI. A technical document is compiled in accordance with Annex. VIl of the Directive, BLOCK NAME DAVID JONES BLOCK POSITION GENERAL MANAGER i valor 12 months sis calraon cei haat Tom stock deat awe gs: Power Toos ostib pace of sue: Power socdenaen&ne: A3/o U1 RoRA swat 3 1g Feat We herewith cerity based on pressure testing and dimensional inspection that the items supplied under the above purchase order are in accorcence with the requirements of the order in particular to a) The fulfilment of material requirements 5) The fulfiment of the required accuracy to, gauge, tolerances, quelity surface () The fulfilment of performance Authorised Signature Honey ch onN Tap. 428382

You might also like