Provides unprecedented
sensitivity by providing high ion
acceptance and transmission
with our proprietary technology
Gate valve
Enables higher uptime and increased
productivity by allowing capillary replacement
without having to vent the instrument
Q1 Ion optics
Reduces contamination and enables lower limits of detection
by increasing ion transmission efficiency to the Q1 mass filter
2
Ion Detector
Increases sensitivity and quantitation
across a wide mass range using a high
energy conversion dynode with low noise
characteristics
3
2.46
0.0197 18.5 97.5
×10 2
0.0394 18.3 104.2
0.0098 ng
Counts
2.48
0.0591 12.5 108.3
2.46
0.0985 9.3 102.4
×10 2
0.197 13.0 95.6
0.0197 ng
Counts
2.5 0.394 5.9 84.8
0.985 5.7 102.1
ANALYTICAL CONFIDENCE
×10 2
1.97 1.6 105.5
0.0394 ng
Counts
2.6 19.7 2.9 99.7
×10 2
0.0591 ng
Counts
Targeted Proteomics 2.6
Response
1,000
12,000
The Agilent 6495B Triple Quadrupole LC/MS10,000system mass range extends to m/z 3000, which 932.7is&beneficial
366.1 in 800
detecting large peptide fragments.
Here we demonstrate the utility of the 6495B8,000
for detecting fragment-ion signals arising from peptides, representing
600 each of the targeted
proteins. This approach is extremely sensitive,6,000
very reproducible and quantitatively precise. 400
4,000
2,000 Zoom 200
0 0
Quantification for G1F glycopeptide EEQYN[+1606.6]STYR 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Replicate injection Replicate injection
×10 2 ×10 4
Blank 2 Amount of total mAb %RSD
Counts
2.48
1.9 digest
EEQYN(+1606.586706)STYR
on-column (ng) (n = 10) % Accuracy
2.46 1.8 y = 943.671754*x – 5.093398
1.7 0.0197
R = 0.99814103
2 18.5 97.5
×10 2 1.6
0.0394 18.3 104.2
0.0098 ng 1.5
Counts
2.48
1.4 0.0591 12.5 108.3
2.46 1.3
1.2 0.0985 9.3 102.4
×10 2 1.1 ×10 2
Response
0.4 1.0
2.6 0.3 19.7 2.9 99.7
0.6
0.2 Zoom 0.2
×10 2 0.1 -0.2
0.0591 ng 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28
Counts
-0.1
2.6
-1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Concentration (ng of mAb digest on-column)
0.90 0.95 1.00 1.05 1.10
Acquisition time (min)
Response
1,000
12,000
932.7 & 366.1 800
10,000
8,000 600
6,000 400
4,000
2,000 Zoom 200
0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Replicate injection Replicate injection
×10 4
2
1.9 EEQYN(+1606.586706)STYR
1.8 y = 943.671754*x – 5.093398
4 1.7 R2 = 0.99814103
1.6
1.5
1.4
1.3
1.2
e
Food Testing – Pesticides
×10 6
Tribenuron-methyl
2.5 396.0 & 155.1
Peak area at 0.5 ms
2.0 = 0.80
Metobromuron Peak area at 5.0 ms
Counts
0
8.6 8.7 8.8 8.9 9.0 9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8
Acquisition time (min)
Overlaid MRM chromatograms of metobromuron and tribenuron-methyl (100 ppb) at dwell times of 5.0, 2.0, 1.0, and 0.5 ms using optimized inter-MRM delay times.
5
ANALYTICAL CONFIDENCE
×107
×105
A B
5.5 Diclofenac Venlafaxine
1.8
5.0 y = 546.946323*x – 34.491767 y = 36438.173667*x – 15563.567037
R2 = 0.99954397 1.6 R2 = 0.99762610
4.5
4.0 1.4
3.5 1.2 OH
Cl
Response
Response
3.0 1.0
2.5 0.8 N
NH
2.0 0.6
Cl OH
1.5
0.4
1.0 O
0.2 O
0.5
0 0
-0.5 -0.2
0 100 200 300 400 500 600 700 800 900 1,000 0 50 100 150 200 250 300 350 400 450 500 550
Concentration (ng/L) Concentration (ng/L)
Calibration plots for diclofenac (negative mode) and venlafaxine (positive mode) in water evaluated for quantitation accuracy and peak area RSD.
6
Environmental Water Analysis
×103
2.4 A
2.2 Atrazine
10 replicate injections Quant.: 216.1 & 174.1
2.0
0.5 ng/L Qual.: 216.1 & 146.0
1.8 RSD = 6.5 % (Quant)
1.6 IDL = 0.10 ng/L ×102
7 0.1 ng/L
1.4 6
Counts
5
1.2 4
1.0 3
2
0.8 1
0.6 0
3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.0
0.4
0.2
0
3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.0
Acquisition time (min)
1.3 B
1.2 Diltiazem
10 replicate injections Quant.: 415.2 & 178.1
1.1
0.5 ng/L Qual.: 415.2 & 150.0
1.0 RSD = 8.1 % (Quant)
×102
0.9 IDL = 0.12 ng/L 6
0.8 5 0.1 ng/L
4
Counts
0.7
3
0.6
2
0.5 1
0.4 0
0.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0
0.2
0.1
0
2.35 2.40 2.45 2.50 2.55 2.60 2.65 2.70 2.75 2.80 2.85 2.90 2.95 3.00
Acquisition time (min)
Overlaid MRM chromatograms for two example PPCPs evaluated in this study at 0.5 ng/L. Reproducible
responses (RSD% <10 %) were observed for both quantifier and qualifier ions of atrazine (A) and diltiazem (B)
at sub-ng/L concentrations.
7
PERFORMANCE SPOTLIGHTS
x101
Area %RSD = 15.1 x101 Area %RSD = 12.4
6.6
6.7 n = 10 injections 6.4
n = 7 injections
6.6
6.5 %Accuracy = 116 6.2 %Accuracy = 85.1
6.4 6.0
6.3
6.2 5.8
6.1 5.6
6.0 5.4
5.9 5.2
5.8
5.7 5.0
5.6
LLOQ of Verapamil 4.8
LLOQ of Bentazon
3.62 3.66 3.7 3.74 3.78 3.82 3.86 3.9 3.94 3.98 4.02 4.06
40 attogram on-column 4.6 1 femtogram on-column
Counts vs. Acquisition Time (min) Blank 4.4 Blank
2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6
Counts vs. Acquisition Time (min)
8
Instrument Detection Limit (IDL)
Today’s “low-noise” mass spectrometry systems demand a statistical standard that measures the true sensitivity of the system; a specification
proportional to ion count. Agilent is leading the way with an innovative method to effectively determine system performance – Instrument
Detection Limit (IDL)
Estriol amount measured Replicates %RSD t(99%) Estriol IDL • IDL is a rigorous metric based on statistical
5 pg/mL (LLOQ) n = 7 injections 11.3 3.143 1.8 pg/mL analysis of precision (%RSD)
MDL = t x (%RSD/100) x Amount = 3.143 x (10.4/100) x 25 fg = 1.8 pg/mL • Measured at or close to the detection limit (LOD)
• Provides an accurate assessment of the system’s
x101
7 Inj1
x101
7 Inj3
x101
7 Inj5
x101
7 Inj7 true detection limit and LLOQ
44.17 41.16 50.07 52.23
6 6 6 6
• A uniform and practical means of evaluating
5 5 5 5
sensitivity performance
x101 x101 x101
7 Inj2 7 Inj4 7 Inj6 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4
Counts vs. Acquisition Time (min)
More Ions = Better Precision
53.76 45.90 54.05
6 6 6
5 5 5
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4
Counts vs. Acquisition Time (min) Counts vs. Acquisition Time (min) Counts vs. Acquisition Time (min)
MassHunter software
High Sensitivity MRM at the Fastest Analysis Times
The analysis of multiple compounds in targeted applications requires the ability to intelligently schedule multiple MRMs while maintaining high
sensitivity at short MRM dwell times. Dynamic MRM sets optimal dwell times to allow confident analysis of a large panel of compounds with
enough data points across the peak for precise and accurate quantitation.
x104
2.0 123 Pesticides, Carbosulfan,
1.9
1.8 1ng/mL 18 data points
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5
Counts vs. Acquisition Time (min)
9
COMPREHENSIVE SOLUTIONS
10
High quality MS application solutions MassHunter software
Simplify your startup and quickly set up a method for your Agilent MassHunter Workstation software simplifies sample
specific application management, MS method optimization, data processing, and data
reporting for quantitative analyses. An impressive suite of tools
facilitates sample analysis, particularly for routine quantitation.
Veterinary drug tMRM database
Curated database with over 650 compounds, with up to 10 MRM These tools include:
transitions, fragmentor voltages, and collision energies for each
• Optimizer software—delivers automated determination of MRM
compound. Instantly build methods for targeted screening and
transitions for quantitation and optimized collision energies for
confident quantitation for hundreds of analytes in a single run.
each analyte
Pesticides tMRM database for triple • Dynamic MRM (dMRM)—ensures the best possible quantitative
results for multi-analyte assays compatible with fast UHPLC
quadrupole LC/MS separation, by specifying cycle times and allowing the software to
Agilent's pesticide tMRM database for LC/TQ systems contains over determine the maximum dwell time for each MRM transition
750 compounds, with up to 10 MRM transitions, fragmentor voltages,
• Triggered MRM (tMRM) data-dependent acquisition—allows fast
and collision energies for each. Instantly build methods for targeted
analyte quantitation together with compound confirmation at the
screening and confident quantitation for hundreds of analytes in a
lowest assay levels
single run.
Agilent CrossLab
You can trust Agilent CrossLab service experts to deliver valuable insights and keep your instru-
ments running at top performance. Our industry-leading services—tailored to meet your needs—
include instrument transition, application consulting, repairs, preventive maintenance, compliance
verification, and education. Ask us how we can support your laboratory today.
11
Any analyte. Any method. One partner: Only Agilent covers all your mass spec needs
Whatever you need to analyze, we are here to help you implement the ideal method to achieve your goals. Agilent
has decades of experience designing and building chromatography and mass spectrometry systems. Our longstanding
partnerships and collaborations span every field of application. This is what enables Agilent to provide you with the
best solution for your analytical needs.
Learn more
www.agilent.com/chem/6495B