Cc libration Of Proportional Reducing Valve NOTE: This calibration procedure must be performed when either the proportional reducing valve and/or the controller has been replaced. This procedure is made at two power shift pressure points of 5 kgffem? [490 kPa (72 psi)] and 25 kgfiem? [2450 kPa (355 psi). Main Pamp Compartment (40) Power shift pressure tap, 1. Stop the engine and install a 4900 kPa (700 psi) pressure gauge to power shift pressure tap (40) 2. Make sure that the pump control backup switch is in the "AUT" position. 3. Start the "Calibration Mode". Refer to the section "Calibration Mode Start-up" NOTE: The engine must be running and have a hydraulic oil temperature of approximately 50°C (122°F) to perform this calibration procedure. 4, Run the engine with engine speed dial switeh at position "10" NOTE: Activation of this calibration mode overrides the AEC function. If the engine speed dial switch is not at position "10" character display (4) will show an "E" in the first column, The engine speed must be corrected within specifications to continue the calibration procedure. 63787F1 Electronic Monitor Panel (Calibration Of Proportional Reducing Valve) (4) Character display. (27) Travel speed LOW (tortoise) indicator, (28) Travel speed control switeh, (31) AEC switeh. (34) Washer switch, (36) Alarm cancel switch $. Depress travel speed control switch (28) until travel speed LOW (tortoise) indicator (27) comes ON. 6. Character display (4) now displays [1 0]. The "1" indicates that the first calibration point has been accessed and the "0" indicates that the middle step of the 19 individual calibration steps has been accessed. Each step will change the power shift pressure by approximately 50 kPa (7.5 psi). 7. To change the power shift pressure: a, To increase the power shift pressure, depress AEC switch (31) once. This will change character display (4) to [1 1]. Each time AEC switch (31) is depressed, character display (4) increases by one until character display (4) displays [1 9]. Also, the pressure reading at power shift pressure tap (40) increases by approximately 50 kPa (7.5 psi) for each increase. The following is an example of character display (4) readings in increasing order Ses aasen she = Middle Step b, To decrease the power shift pressure, depress washer switch (34) once to lower the value displayed in character display (4). Fach time washer switch (34) is depressed, character display (4) decreases by one in descending order until character display (4) displays [1-9]. Also, the pressure reading at power shift pressure tap (40) decreases by 50 kPa (7 psi) for each decrease, The following is an example of character display (4) readings in decreasing order: BREEDS RS = Middle Step SEASLELRESHRMEMNDAZS 8. To set "Calibration Point No. 1", perform the following steps. a, Depress washer switch (34) until the pressure reading at tap (40) is less than 490 kPa (72 psi). b. Depress AEC switch (31) until the pressure reading at tap (40) increases to approximately 490 kPa (72 psi). NOTE: Pressure adjustments must always be made as the pressure is being increased ¢, Depress alarm cancel switch (36) to store the data in the controller. 4, Once the data is stored in the controller, display (4) changes to [2 0], which indicates that the first calibration point has been accepted and the second calibration point can be performed. At this time, the character display flashing light mode will change to a continuous lighting mode. 9. To set "Calibration Point No. 2", perform the following steps: a, Depress washer switch (34) until the pressure reading at tap (40) is less than 2450 kPa (355 psi). b. Depress AEC switch (31) until the pressure reading at tap (40) increases to approximately 2450 kPa (355 psi), NOTE: Pressure adjustments must always be made as the pressure is being increased ¢. Depress alarm cancel switch (36) to store the data in the controller 4, Once the data is stored in the controller, display (4) will change to [1 0], which indicates that the second calibration point has been accepted and the controller has reset to the first calibration point 10. Stop "Calibration Mode" (unless another function selection is desired). See the section, "Calibration Mode Stop Procedure" Pre 4 woe va oI O1 Co O2 Or rave, 5 AA CEL Ow oO on C63788P1 Electronic Monitor Panel (Stopping Calibration Mode) (4) Character display. (37) Service switch. Use either of the following two methods 1, Place engine in low idle position and turn the engine start switch to the OFF position, 2. Depress service switch (37) for a minimum of two seconds until character display (4) changes from "Calibration Mode" to engine speed dial position.

You might also like