Information Technical Description (TED:BSS)

Base Station System BS-240/241

Modulation Output Power Output Power


(dBm) (Watt)

““ ““ 8PSK 45.3 33.9


GSM 1900 ECU PV2 GMSK 47.3 53.7
““ ““ 8PSK 45.3 33.9
GSM 1900 ECU PHPV2 GMSK 48.3 67.6
““ ““ 8PSK 45.3 33.9
GSM 1900 ECU PHPV3 GMSK 48.3 67.6
““ ““ 8PSK 45.3 33.9

Tab. 2.1 Power Amplifier Output Level

Carrier Unit (CU )


GSM 900: minimum guaranteed output power CU = 50 Watt tolerance value: 47.0 dBm
i - 47.6 dBm (50 W - 57.5 W); GSM 1800, GSM 1900: minimum guaranteed output power
CU = 34 Watt tolerance value: 45.3 dBm - 46.0 dBm (34 W - 39.5 W).
The mentioned data are guaranteed from Module Factory Test only. The typical output
power at CU output is for:
GSM 900: 47,3 dBm GSM 1800: 45.7 dBm
To verify the typical output power values in field measurements, the tolerance value of
the used measurement equipment, environmental conditions and GSM 05.05 specifica-
tions have to be considered.

Carrier Unit (GCU )


GSM 900: minimum guaranteed output power GCU = 50 Watt (GSMK); GSM 1800:
i minimum guaranteed output power GCU = 50 Watt (GSMK).
The GSM 1800 variant of the GCU V2 offers higher output power than the correspond-
ing CU (about 15 Watt): the increased output power of the GSM 1800 GCU V2,
has to be taken into consideration in the radio network planning.

EDGE Carrier Unit (ECU )


GSM 850, GSM 900: minimum guaranteed output power ECU = 63 Watt (GMSK) / 40
i Watt (8PSK); GSM 1800, GSM 1900: minimum guaranteed output power ECU = 50
Watt (GMSK) / 32 Watt (8PSK).
The mentioned data are guaranteed from Module Factory Test only.

2.3 Rack Configuration


The BS-240/241 family, with 8 transceivers per Rack, which is expandable up to 24
transceivers in 3 Racks and can be supplied in two versions:
– a BS-240 for indoor installation, and
– a BS-241 for outdoor installation (also equipped with integrated link equipment,
Battery Backup and a cooling system).